. Job: - - wrightsoft° Project Summary Date: Enure House By: QUICK CALCS, INC. 317 ST. LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM. For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: '" \ _O \�- a \" l-. CL Q Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 . Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Cool' Area (ft2) 1446 Volume (ft3) 12511 1446 12511 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25H BC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 OF. 1160- cfm 0.049 cfm/Btuh 0.50 in H2O Input = 7 M, Output = 23009 Btuh, 100 AFUE SCANNED BY St Lucie County Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (O cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm. Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wrightsoft` 2017-Apr-11 09:29:38 Right -Suite® Universal 201717.0.14 RSU08101 age 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N FILE P201Y - - wrightsoftRight-M) Worksheet Job: Entire House Date` By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House BEDROOM 2 EVosed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 1445.5 ftz 1.0 x 297.0 ft 297.0 ft2 Ty! Construction U-value Or HTM Area (ft') Load Area (ft.) Load number (Btuh/ftk-OF) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VN 13AAocs 0.143. n 4.00 : 2.55 503 465 . 1862 1184 .: 72 72 288' ° 183 I ! G. ,4A5 2om: " " 13A-4ocs 0.770 0.143 n:. a 21.56 4.00 - 19.31 2.55 38 128 0, 83 815 333 730 212 0 0 0 0 0 0 0 0 11 1Ac1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 W V)/ 13AAocs 13AAocs 0.143 0.143 'se s 4.00 4.00 2.55 2.55 34 360 34 353 136 1414 86 899 0 216 0 216 0 865 0 550 �--G IA-c1om 13A�7ocs 1270 0143 s w 35.56 4:00 34.77 2.55 7 310 7 237 247 949 241 603 0 104 0 .72 0 288 0 183 1A,o1om - - 1.270 w 35.56 55.21. 32 2 . 1140 1776 . 32 2, 1140 - 1770 P '4A5r2cm . 12C-0sw 0.770 0.091 w 21.56. 2.55 19.31 1.28 41 192 4.1 192 880 489 :. 788 246 0 0 0 0 : 0 0 ':. 0 0 C ,{ i16A30md 0.032. - '090 2.32. 1446 .1446 r 1295 . 3354 .. 297. ;• '297 266 689 F 22A tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 i 0 6 c),AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration b) Room ventilation 2887 0 791 0 848 0 232 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less mdemal load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Dilctloads 32% 49% 0 0 17848 5654 0 0 17520 8536 32% 49% 0 0 5053 1601 0 0 4925 2400 Total room load Air required (cfm) 23503 1160 26056 1160 6653 328 7325 326 Calculations approved byACCA to meet all r6guirements of Manual J 8th Ed. L wrightsoft, 2017-Apr-11 09:29:38 �� Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N I - - wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 2 3 4 5 Rim name F�giosed wall Room height Room dimensions Room area WIC O ft 8.0 ft heat/cool 6.0 x 9.0 ft 54.0 ft2 KrrCHEN O ft 8.0 ft heat/cool 1.0 x 172.0 ft 1720 ft2 Ty I Construction number U-value ' (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area or perimeter (ft) (Btuh) ors perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 11 I 13A4ocs - #A5 tam .0.770 13AAocs 1Aclom 11DO 13A-4ocs 13A-4ocs 1Aclom 13A4ocs 1A-clom 4A5.2om 12C-0sw .16A=30md� ,, 22A tpl --'0 143 0.143 1.270 0.390 0.143 0.143 1.270 O.-M 1.270 .0.770 0.091 0.032 0.989 n.. •n .. a a a : se s s : w - w w : - - 4:60 21.56 4.00 35.56 10.92 4.00 4.00 35.56 4.00 '35.56 21.56 2.55 . 0.90 27.69 2.55 19.31 2.65 87.29 11.31 2.55 2.55 34.77 2.55 155.21 19:31 1.28 . 2.32 0.00 0 0 0 0 0 . 0 0 0 0 0 0. 0 .' 54 54 . 0 ' ' :.0 .0 0 0 0 0 0 0 0 0 0. .. 54 0 , 0. . 0 0 0 0 0. 0 0 0 0 0 0 - 48:: 0 0 .0 0 0 0 0 0 0 0 0 0 0 125 0 p 0 0 0 0 0 0 0 0 0 0 64 . 172 172 0 : '0 0 0 0 0. 0 0 0 0 0.. 64 172 0 0 [0 0 0 0 A 0 0 0 0 0 163 ` .:. 154; 0 0 6 0 0 0 0 0 0 0 0 0 82 : 199 0 1 V: W L-=C P C f , F r 6 c)�ED excursion -9 -170 Flivelope i loss/gain 48 117 317 311 12 a) b) Infiltration Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 p 0 p p 2000 Subtotal (lines 6 to 13) 48 117 317 2311 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 32% 49% 0 0 0 48 15 0 0 0 117 57 32% 49% 0 0 0 317 10 0 0 0 0 2311 1126 I Total room load Ai%required (cfm) I 64 178 421 341 ' 8th Ed. -IV- wrightsoft Right -Suite® Universal 2017 17.0A4 RSU08101 ...uick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 2 - wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM 1 2 Room name E)�osed wall BATH 5.0 ft BEDROOM 2 34.2 ft 3 4 5 Room height Room dimensions Room area 8.0 ft heat/cool 9.0 x 5.0 ft 45.0 ft2 8.0 ft heat/cool 1.0 x 203.5 ft 203.5 ft2 TV Construction number LI-value (BtulV t2--°F) Or HTM (Btuhlft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�1 A :- 13A46g6 13A-4ocs 0.143 .0.770 0.143 -' n n a ..4.00- - 21 ZI5 4.00 _2.55 19:31 2.55 40 0 0 40 .. 0 0 160 0 0 102 0 0 128 0 80 - 128 0." 56 513 .0 225 326 . 0 143 11 1A-c1om 11DO 13A4ocs 13A-4ocs 1Aclom 13A-4ocs 1Ac1om. •: 4A5-2om . 12C-0sw- ':16A-30md '-. 1.270 0.390 0:143 0.143 1.270 .0143 1.270 0:770 0.091 0.032. a a se s s w. - w w - 35.56 10.92 4.00 4.00 35.56 4.00 35:56 '21.56 2.55 0.90 87.29 11.31 2.55 2.55 34.77 2.55 - 55.21 ` -1931 1.28 2.32 0 0 0 0 0 0 0 . 0: 0 45 0 0 0 0 0 0 0 0 0 . 45 0 0 0 0 0 0 0 0 0 40 0 0 0 0 0 0 0 0 0 104 24 0 34 32 0 0 0 0 0 204 2 0 34 32 0 0. •0 0: 0 204 848 0 136 128 0 '0 0 -0 0 182 2082 0 86 81 0 0 0 0 0 = : 472 W V1J P C ' F 22A tpl 0.989 27.69 0.00 45 5 138 0 204 34 946 0 t 6 c)'AED wcursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a), Infiltration b), Room ventilation 87 0 24 0 593 0 162 0 13 i Internal gains: Occupants @ 230 Appliances/other 0 0 0 1 230 0 Subtotal (lines 6 to 13) 425 214 3571 3498 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 32% 49% 0 0 0 425 135 0 0 0 214 104 32% 49% 0 0 0 3571 1131 0 0 0 3498 1704 Total room load Air required (cfm) 560 28 3181 141 4702 232 5203 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .4C� § P I � wrightsoft- 2017-Apr-11 09:29:38 RightSuite® Universal 2017 17.0.14 RSU08101 Page 3 ..uick CalcslDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wl ightsoft° Right-M Worksheet Date: j Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 E" ed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ftz 526.0 ftz Tyi Construction U-value Or HTM Area (ftz) Load Area (ft.) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool L- 13A�ocs . '4A5 0.143 n` 4:06 2 55 0 0 0 - . 0 . 255 . 217 '869 ' 552 G tom .F 0.770 . rr.: 21:56 . ' 19.31 0 0 •' . 0 .0 38 . ."0 . `'-815 ., . ' .730 13A-400s 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W .13AAocs 0.143 se 4.00 2:55 0 0 0 0 0 0 0 0 y/ 13AAocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-4ocv 0.143 w 4.00 2.55 0 0 0 0 206 165 661 420 1Ac1om, 1,270 w 35.56 - 55.21 0 - 0 0 0 0 0 :0 0 4A5-t6m ' 0:770 w 21.56 19.31 0 0 0 0 41 41 880 .. 788 P 12C-0sw 0.091. - 2.55 1.28 56 56 143 72 0 0 0 0 C :16A-30md; . 0i032 - ' i.0.90 '. 2.3.2 ` ' 42 42 . 38 : 97 .,. , .526, '526. ' .. =471, ; -1220 F I I 22AAPl 0.989 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)IAED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a)f Infiltration 104 28 997 273 b)I Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal pines 6 to 13) 643 298 5994 5112 L�s a demai load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 496/6 204 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Ait required (cfm) 421 20 1 3901 338 of Manual J 8th Ffl- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSUD8101 .uick Calcsk0ocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 4 i - I +{ - wrightsoft°Right-M Worksheet Entire House QUICK CALLS, INC. 317 ST. L!JCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.46M796 Email: QUICKCALCS@10L.COM Job: Date: By: 1 2 3 4 5 Room name Rio wall Room height Room dimensions Room area FOYER 7.0 ft 8.0 ft heat/cool 1.0 x 50.0 ft 60.0 ft2 M. BATH 8.0 ft 8.0 ft heat/cool 7.0 x 8:0 ft 56.0 ft2 Ty Construction number U-value (Btuh/ft2--°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat , Cool 6 11 W VI! L { ';13A-4ocs .: .4A52om:; 13A-0ocs IA-clom 11DO 13AAocs 13A4ocs 1Aclom 13A-4ocs 1A-clom ._ 4A52om... 12C-0sw .16A-30md 22/ktpl 0143 .0.770. 0.143 1.270 0.390 0.143 0.143 1.270 0.143 1.270 .0.770 0.091 0:032 0.989 -n > n a a a se s s w ` w •. w - - - 4.00. 21;56 4.00 35.56 10.92 4.00 4.00 35.56 4.00 35.66 21.56 2.55 0:90: 27.69 2 55 . .19:31' 2.55 87.29 11.31 2.55 2.55 34.77 2.55 :. 65.21 19.31 1.28 - 2,32 0.00 : 'B -: 0 48 0 21 0 0 0 0 0 0 72 50 50 .' 8 ': .0 27 0 21 0 0 0 0 0 0 72 50 7 32 0 108 0 229 0 0 0 0 0 6 183 45 194 ,- 20 0 69 0 238 0 0 0 0 0 0 92 _. 116 0 0 . 0 0 0 0 0 64 7 01 0` 0- 0 56 56 . 0 0: 0 0 0 0 57 7 0 0 0: 0 ` 56 8 0..- 0 0 0 0 228 247 0 Of 0 0 . 50 222 0 0 l 0 0 0 0 145 241 0 0 .. 0 0 .' '. ;130 0 c' Vy P •C. ' F 6 c)*D excursion -39 Envelope loss/gain 792 496 747 478 12 a)l Infiltration b)� Room ventilation 121 0 33 0 138 0 38 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 913 529 885 516 14 15 Less demal load Less transfer Redistribution Subtotal Duct loads 32% 490/a 0 0 0 289 0 0 0 258 32% 49% 0 0 0 885 280 0 0 0 516 251 Total room load Aid required (cfm) 1202 59 787 351 1166 58 768 34 Calculations approved byACCA to meet all requir -P- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N J 8th Ed. 2017-Apr-11 09:29:38 Page 5 - +- wrightsoft- Duct System Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Heating. Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply] / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual lair flow 1160 cfm 1160 cfm Total effective length (TEL) 176 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox 0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT%DINING h 3946 195 169 0.300 7.0 0x0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox0 VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043, 1091 0.285 1020 14.0 0 x 0 VinlFlx �I-- wrightsoft° Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Name , Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N