Loading...
HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATION - 11-14-18RECEIVED €I Planning & Development Services Department Building & Code Regulations Division I -.....;:__,::._._..,.__.m...___._...v.u._.....:.a 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462- 5, Certification for Design Load Compliance Project Name: Mr & Mrs Jenness Project Address: 2705 Bent Pine Dr Fort Pierc, FL 34591 Permit #: 1V H) I I O Occupancy Type: R-3 NOV 14 2018- Lucie County, Permitting Construction Type: IV C® INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected i,nd certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 6th Edition Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially'Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph 132 ASD LRFD End Zone Width: 5 ft 5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openE igs): Zone 1: +16.3/-40.2 Zone 2: +16.3/-67.4 Zone 3: 416.3/-101.4 Zone 4: +40.21-43.6 Zone 5: +40.2/-53.6 Garage: +3''2/-39.8 7. Design Loads: Floor: NSA PSF Roof/Dead: 25 PSF Roof/Live: 35 Balcony: N/A. PSF Dock: NSA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA -_PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have be.en designed to comply with the applicable structural portions of the bui?ding codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces sp .k'9%a,_ Lillian Gonzalez Print Name Goarch Engineering, Inc 79442 Cert # & Coy Cert Auth. 4994 Luqui Ct West Palm Beach, FL 33415 Company Name & Address RECEIVED Planning & Development Services Department • Building & Code Regulations Division NOV 4 2018 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-15 3�. Lucie Count ....� _._�_.__._...._-.__._...._,_. y, Permitting Certification for Design Load Compliance Project Name: Mr & Mrs Jenness Project Address: 2705 Bent Pine Dr Fort Pierc, FL 34591 Permit #: 18 I Il - 1110 Occupancy Type: R-3 Construction Type: IV INSTRUCTIONS FOR USE: �C'a/ • This certification must be completed, signed, and sealed by the design professional of record. 19 • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 6th Edition Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III _ IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph 132 ASD __LRFD End Zone Width: 5 ft i 5. Mean Roof Height 15 ft Root Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all,plan openings): Zone 1: +16.3i-40.2 Zone 2: +16.3i-67.4 Zone 3: +16.3i-101.4 Zone 4: +40.2i-43.6 Zone 5: +40.2i-53.8 Garage: +35.2i-39.8 7. Design Loads: Floor: N/A PSF Roof/Dead: 25 PSF Roof/Live: 35 Balcony: NIA PSF Dock: NSA PSF Deck: N/A PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design 1 forces specifi;e¢{g,, Lillian Gonzalez Print Name Goarch Engineering, Inc 79442 Cert # & Co. Cert Auth. 4994 Luclui Ct West Palm Beach, FL 33415 Company Name & Address