Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2W7 FLORIDA, ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE \ n- Builder Name: WYNNE Street: WYNNE DEV. �-'�`� Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, ^ Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New consItruction,or existing New (From Plans) 9. Wall Types (1688.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ftz b. Frame - Wood, Adjacent R=11.0 240.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? Yes 10. Ceiling Types (1720.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ftz 6. Conditioned floor area above grade (ftz) 1720 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 1 c. N/A 11. Ducts R= ftz R ftz 7. Windows(i 55.4 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Sgl, U=0.54 115.42 ftz SHGCa SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC:! SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftz SHGC:1 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 34.8 HSPF:8.50 SHGC:I Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1720.0 sgft.) Insulation Area EF: 0.970 a. Slab -On, Grade Edge Insulation R=0.0 1720.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: ` 0.090 Total Proposed Modified Loads: 56.15 PASS Total Baseline Loads: 56.24 I I hereby certify that the plans and specifications covered by Review of the plans and '' tE Srg?, this calculation are in compliance with the Florida Energy specifications covered by this�O Code. calculation indicates compliance with the Florida Energy Code. nr„'O•, . s�' ••, u O PREPARED By' DATE: Before construction is completed this building will be inspected for; compliance with Section 553.908 - ;d * n I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WF I OWNER/AG NT: OWNER/AU N I)n BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE C`OPY 4/3/2018 11: i 6 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE ROYALE Bedrooms: 3 Address Type: Street Address Building Type: Use% Conditioned Area: 1720 Lot # Owner Name, Total Stories: 1 Block/Subdivision: # of Units:, 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST..LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: , CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V/ Design..Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH _MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.'BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS #1 Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 --_- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ____ 0 1 0 I 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft2 _--- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft2 ---_ 0 1 0 4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R40,5-2017 FLOORS j# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Glade Edge Insulatio LAUNDRY E ft 0 42 ft2 ---- 0 1 0 19 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0 i 528 ft2 ---- 0 1 0 1 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ---- 0 1 0 ROOF / V I Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 I Gable or Shed Metal 1813 ft2 286 ft2 Light 0.6 No 0.9 No 0 18.4 i ` ATTIC / V I # type Ventilation Vent Ratio (1 in) Area RBS IRCC i 1 I Full -attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft2 0.1 Wood { Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING • 30 Blown 528 ft2 0.1 Wood I 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ft In Et In Aren _AhSoro 1 N=iSE Exterior Concrete Block - Ext InsiHEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block - Ext InsiHEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0 3 i W= iNE Exterior Concrete Block - Ext InsidEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 4 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 _ 5 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 6 N=>ISE Exterior Concrete Block - Ext InEffDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 7 NE >S Exterior Concrete Block - Ext InREDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 _ 8 E=>SW Exterior Concrete Block - Ext InGEDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 _ 9 SE=I W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 10 S=> W Exterior Concrete Block - Ext Ind3ffDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 11 NE='I S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0 12 E=>SW Exterior Concrete Block - Ext Insul ENTRY . 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 i 4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R40I5-2011 WALLS Adjacent Space Cavity Width le Et In Et Height In Area Sheathing Framing Solar R-X/ahle Eracf"on Ah Below 13 S j>NW Exterior Concrete Block - Ext InsL11AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 14 N=>SE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 28 0 8 0 224.0 ft2 0 0 0.5 0 15 W 7 >NE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 16 N =>SE Exterior Concrete Block - Ext IndMDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 _ 17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8 240.0 ft2 0.23 0.5 0 i DOORS # •Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V ':ID Overhang # Ornt -' Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Single Yes 0.54 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 4 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 'E=>SW 8 Metal Low-E Single Yes 0.54 0.25 N 23.2 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 14 Metal Low-E Single Yes 0.54 0.25 N 36.8 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>NE 15 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft2 10 ft 0 in 1 ft 4 in None None 6 N=>SE 16 Metal Low-E Single Yes 0.54 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None GARAGE #, Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1� 300 ft2 300 ft2 30 ft 8 ft 11 i INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 HEATING SYSTEM #I System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts i 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 4/3/2018 11:36 AM . EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R4015-2017•' HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None i SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF lone None ft2 DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin ]Jan Feb Heatng X] Jan Feb Mar XMar A r Ma X Jun X Jul Jun f l Jul Aug rl Au Se IXISep Oct Oct Nov Nov HNov Dec Dec Venting [ ]Jan Feb X Mar Apr May Jun [ Jul Aug Sep Oct Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD)i AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 .78 78 78 78 78 78 78 78 78 I Heating (V11D) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 • I ' I 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: WYNNE THE ROYALE Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce i I COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. t Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and an gaps in the air barrier shall be sealed. Y 9 p shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavties cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building I shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing a6d wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on I installation readily conforms to available space shall extend behind piping and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sp.r.in k ler cover plates and walls or.ceilonas, a. M auwuun,!wsNeuwn U1 iUg waus snan de in accordance with The provisions Oi IGG-4UU. 4/3/2018 11:36 AM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) - DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ftZ 3. Number 0 units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 3 d. N/A R= ftZ 5. Is this a worst case? 10. Ceiling Types Yes Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ftZ 6. Conditioned floor area (ftZ) 1720 b. N/A R= ftz 7. Windows- Description Area c. _ Z a. U-Factor: Sgl, U=0.54 1 115.42 ftZ 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ftZ 6 325 SHGC:. SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ftZ SHGC:, SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftZ a. Central Unit 34.8 SEER:15.00 SHGC:I d. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: a. Electric Heat Pump 3.316 ft. 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft Z a. Electric EF: 0.97 b. N/A R= ftZ c. N/A � R= b. Conservation features ftZ None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �$E ST Construction through the above energy saving features which will be installed (or exceeded) o� = A4 in this home before -final inspection. Otherwise a new EPL Display Card will be completed based on installed Code compliant features. 16. I Builder Signature: Date: v - Address of New Hbme: '�2 \-\\_f, %:) "bQ \ � � City/FL Zip: ���p,� CQ 1 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EE•M) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsup�port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters.' For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1