HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATIONPlanning & Development Services DelArtment
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: LEBEL
I Project Address: 10701 S OCEAN DR LOT 924
Permit #:
Occupanpy Type: Construction Type:
SCANNED
St LUCIB County
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
�• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10
. Structure Designed as (check one): Enclosed Partially Enclosed X Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1� ft
. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: +60.61-64.1 Zone 5: +70.1/-74"5 Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
I
0. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
f rces specified:
DANIEL PAUL RETHERFORD 72451
�Print Name Cert # & Co. Cert Auth.
law ��V°g
1402 HARTMAN ROAD, FT PIERCE, FL 34947
n„e
,.-, •� �
o--
.� � Company Name &Address
' . � •. be
evise7/Z512014
�+i e- * j'r w
'Ot" V
Project Name: LEBEL
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance SCANNED
'Project Address:
10701 S OCEAN DR LOT 924 �� Luc CpU
i
(Permit #: 1811-0131 Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
!1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): Enclosed Partially Enclosed X Open
3. Risk Category: _I X II III IV Exposure Category: B C X D
,4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft
5. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft
I6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: +so.si sa.1 Zone 5: +70'1/74'S Garage:
I
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I, certify'that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
I
omply with the., applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also�'certif ®����I��&A!,, gments depicted on these plans provide adequate resistance to the design
forces specified: ,% ` �;�0 P o®®®
®e® �®®�ANIEL PAUL RETHERFORD 72451
�r1nt Name Cert # & Co. Cert Auth.
;nature, Date;; arid_Seal.. 1402 HARTMAN ROAD, FT PIERCE, FL 34947
-Company Name & Address
wised 07/25/2014