Loading...
HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATIONPlanning & Development Services DelArtment Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: LEBEL I Project Address: 10701 S OCEAN DR LOT 924 Permit #: Occupanpy Type: Construction Type: SCANNED St LUCIB County INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. �• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 . Structure Designed as (check one): Enclosed Partially Enclosed X Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1� ft . Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +60.61-64.1 Zone 5: +70.1/-74"5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: I 0. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design f rces specified: DANIEL PAUL RETHERFORD 72451 �Print Name Cert # & Co. Cert Auth. law ��V°g 1402 HARTMAN ROAD, FT PIERCE, FL 34947 n„e ,.-, •� � o-- .� � Company Name &Address ' . � •. be evise7/Z512014 �+i e- * j'r w 'Ot" V Project Name: LEBEL Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance SCANNED 'Project Address: 10701 S OCEAN DR LOT 924 �� Luc CpU i (Permit #: 1811-0131 Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) !1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed X Open 3. Risk Category: _I X II III IV Exposure Category: B C X D ,4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft 5. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft I6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +so.si sa.1 Zone 5: +70'1/74'S Garage: I 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I, certify'that, to the best of my knowledge and belief, the attached plans & specifications have been designed to I omply with the., applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also�'certif ®����I��&A!,, gments depicted on these plans provide adequate resistance to the design forces specified: ,% ` �;�0 P o®®® ®e® �®®�ANIEL PAUL RETHERFORD 72451 �r1nt Name Cert # & Co. Cert Auth. ;nature, Date;; arid_Seal.. 1402 HARTMAN ROAD, FT PIERCE, FL 34947 -Company Name & Address wised 07/25/2014