HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATIONi
Planning & Development Services Department
COLINTY Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
� Project Name:
MENDEZ
Project Address: 10701 S OCEAN DR LOT 809 e+ Luder•0un$y
Permit #: 1811-0133
Occupancy Type:
Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions..
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): Enclosed Partially Enclosed X Open
j 3. Risk Category: _I X II III IV Exposure Category: B C X D
4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft
S. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: +so.si sa.1 Zone 5: +70'1/ 74'5 Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
18. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, tot ��Ca��`�VilMiAgowl edge and belief, the attached plans & specifications have been designed to
comply with tk��,��;ia IgSr�'ctal;rtions of the building codes currently adopted and enforced by St. Lucie
County. I a��cprttify°that �t°r�acC r I cents depicted on these plans provide adequate resistance to the design
forces speam D O i�°►'� j
m DANIEL PAUL RETHERFORD 72451
� B
Print Name Cert # & Co. Cert Auth.
nd,Se
al nature, Date',al�'`.Qj'�°�L 1402 HARTMAN ROAD, FT PIERCE, FL 34947
Company Name & Address
Revised 07/25/2014