Loading...
HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATIONi Planning & Development Services Department COLINTY Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance � Project Name: MENDEZ Project Address: 10701 S OCEAN DR LOT 809 e+ Luder•0un$y Permit #: 1811-0133 Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions.. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed X Open j 3. Risk Category: _I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft S. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +so.si sa.1 Zone 5: +70'1/ 74'5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 18. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, tot ��Ca��`�VilMiAgowl edge and belief, the attached plans & specifications have been designed to comply with tk��,��;ia IgSr�'ctal;rtions of the building codes currently adopted and enforced by St. Lucie County. I a��cprttify°that �t°r�acC r I cents depicted on these plans provide adequate resistance to the design forces speam D O i�°►'� j m DANIEL PAUL RETHERFORD 72451 � B Print Name Cert # & Co. Cert Auth. nd,Se al nature, Date',al�'`.Qj'�°�L 1402 HARTMAN ROAD, FT PIERCE, FL 34947 Company Name & Address Revised 07/25/2014