HomeMy WebLinkAboutFDEP LETTERFLORIDA DEPARTMENT Of G'oveno
Environmental Protection Carlos Lopez-Cantera
Lt. Governor
Southeast District Noah Yalenstein
3301 Gun Club Road, MSC7210-1
West Palm Beach, FL 33406 Secretary
561-681-6600
Joe Mendez
P.O. Box 17464 SCANNED
Fort Lauderdale, FL 33318 BY
St Lucie County
Re: File No.: 43-0368903-001,002,003,004-EE
File Name: Mendez
Dear Mr. Mendez,
On September 21, 2018, we received your application for an exemption to perform the following
activities; (1) install 88 sq. ft. marginal dock; (2) install a new boat lift; (3) replace a 35 In. ft.
seawall within 18 inches waterward (wetface to wetface) of the existing seawall; and (4) install
ibatter and king pilings. The project is located within a manmade canal off the Indian River, Class
II Waters, adjacent to 10701 S. Ocean Drive, Lot 809, Jensen Beach (Section 11, Township 37
South, Range 41 East), in St. Lucie County (Latitude N 25' 16' 14.085", Longitude W 80' 12'
27.8597").
,This determination does not convey or create any property right, or any interest in real
property. This determination does not authorize any trespass, entrance upon, or activities on
;property which is not owned or controlled by you, or convey any rights or privileges other than
those specified in this determination and applicable rules and statutes.
You shall hold and save the Department harmless from any and all damages, claims, or liabilities
which may arise by reason of the activities described in this determination or any use of the
structure/activities.
Your request has been reviewed to determine whether it qualifies for (1) regulatory exemption, (2)
proprietary authorization (related to state-owned submerged lands), and (3) federal approval that
may be necessary for work in wetlands or waters of the United States.
Your project qualifies for all three. This letter does not relieve you from the responsibility of
obtaining other federal, state, or local authorizations that may be required for the activity. Please
refer to the specific section(s) dealing with that portion of the review below for advice on how to
proceed.
1. Regulatory Review — VERIFIED
Based on the information submitted, the Department has verified that the activity as proposed is
exempt, under Chapter 62-330.051 (5)(b), (12)(b,d), Florida Administrative Code, from the need
to obtain a regulatory permit under part IV of Chapter 373 of the Florida Statutes.
I �F 1, L F_2271�' C -0 PY
File No.: 43-0368903-001,002,003,004-EE
File Name: Mendez
Page 2 of 5
This exemption verification is based on the information you provided the Department and the
statutes and rules in effect when the information was submitted. This verification will expire after
one year, and will not be valid at any other time if site conditions materially change, the project
design is modified, or the statutes or rules governing the exempt activity are amended. However,
the activity may still be conducted without further notification to or verification from the
Department after the one-year expiration of this verification, provided: 1) the project design does
not change; 2) site conditions do not materially change; and 3) there are no changes to the statutes
or rules governing the exempt activity. In the event you need to re -verify the exempt status for the
activity after the one-year expiration of this verification, a new application and verification fee will
be required. Any substantial modifications to the project design should be submitted to the
Department for review, as changes may result in a permit being required. Conditions of compliance
with the regulatory exemption are contained in Attachment A.
2. Proprietary Review — NOT REQUIRED
,The activity does not appear to be located on sovereign submerged lands, and does not require
further authorization under Chapter 253 of the Florida Statutes, or chapters 18-20 or 18-21 of the
'Florida Administrative Code.
3. Federal Review — SPGP APPROVED
'Your proposed activity as outlined on your application and attached drawings qualifies for Federal
authorization pursuant to the State Programmatic General Permit V, and a separate permit or
authorization will not be required from the Corps. Please note that the Federal authorization expires
on July 26, 2021. You, as permittee, are required to adhere to all General Conditions and Special
,conditions that may apply to your project." A copy of the SPGP V with all terms and conditions
and the General Conditions may be found at:
http•//www saj usace army mil/Portals/44/docs/regulatory/sourcebook/permitting/general permits
/SPGP/SPGPV-Permit%20Instrument-Complete.pdf?ver=2016-07-27-071925-250.
Authority for review - an agreement with the USACOE entitled "Coordination Agreement
Between the U. S. Army Corps of Engineers (Jacksonville District) and the Florida Department of
Environmental Protection, or Duly Authorized Designee, State Programmatic General Permit",
Section 10 of the Rivers and Harbor Act of 1899, and Section 404 of the Clean Water Act.
Additional Information
Please retain this letter. The activities may be inspected by authorized state personnel in the future
to insure compliance with appropriate statutes and administrative codes. If the activities are not
in compliance, you may be subject to penalties under Chapter 373, F.S., and Chapter 18-14, F.A.C.
NOTICE OF RIGHTS
This action is final and effective on the date filed with the Clerk of the Department unless a petition
for an administrative hearing is timely filed under Sections 120.569 and 120.57, F.S., before the
deadline for filing a petition. On the filing of a timely and sufficient petition, this action will not
be final and effective until further order of the Department. Because the administrative hearing
process is designed to formulate final agency action, the filing of a petition means that the
Department's final action may be different from the position taken by it in this notice.
I
Pile No.: 43-0368903-001,002,003,004-EE
File Name: Mendez
Page 3 of 5
Petition for Administrative Hearing
A person whose substantial interests are affected by the Department's action may petition for an
administrative proceeding (hearing) under Sections 120.569 and 120.57, F.S. Pursuant to Rule 28-
106.201, F.A.C., a petition for an administrative hearing must contain the following information:
(a) The name and address of each agency affected and each agency's file or
identification number, if known;
(b) The name, address, any email address, any facsimile number, and telephone number
of the petitioner; the name, address, and telephone number of the petitioner's
representative, if any, which shall be the address for service purposes during the course of
the proceeding; and an explanation of how the petitioner's substantial interests are or will
be affected by the agency determination;
(c) A statement of when and how the petitioner received notice of the agency decision;
(d) A statement of all disputed issues of material fact. If there are none, the petition
must so indicate;
(e) A concise statement of the ultimate facts alleged, including the specific facts that
the petitioner contends warrant reversal or modification of the agency's proposed action;
(f) A statement of the specific rules or statutes that the petitioner contends require
reversal or modification of the agency's proposed action, including an explanation of how
the alleged facts relate to the specific rules or statutes; and
(g) A statement of the relief sought by the petitioner, stating precisely the action that
the petitioner wishes the agency to take with respect to the agency's proposed action.
'The petition must be filed (received by the Clerk) in the Office of General Counsel of the
Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000.
(Also, a copy of the petition shall be mailed to the applicant at the address indicated above at the
time of filing.
Time Period for Filing a Petition
In accordance with Rule 62-110.106(3), F.A.C., petitions for an administrative hearing by the
applicant must be filed within 21 days of receipt of this written notice. Petitions filed by any
persons other than the applicant, and other than those entitled to written notice under Section
1 120.60(3), F.S. must be filed within 21 days of publication of the notice or within 21 days of receipt
of the written notice, whichever occurs first. Under Section 120.60(3), F.S., however, any person
who has asked the Department for notice of agency action may file a petition within 21 days of
receipt of such notice, regardless of the date of publication. The failure to file a petition within the
appropriate time period shall constitute a waiver of that person's right to request an administrative
determination (hearing) under Sections 120.569 and 120.57, F.S., or to intervene in this proceeding
and participate as a party to it. Any subsequent intervention (in a proceeding initiated by another
party) will be only at the discretion of the presiding officer upon the filing of a motion in
compliance with Rule 28-106.205, F.A.C.
Extension of Time
I Under Rule 62-110.106(4), F.A.C., a person whose substantial interests are affected by the
Department's action may also request an extension of time to file a petition for an administrative
hearing. The Department may, for good cause shown, grant the request for an extension of time.
l
File No.: 43-0368903-001,002,003,004-EE
File Name: Mendez
Page 4 of 5
Requests for extension of time must be filed with the Office of General Counsel of the Department
at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, before the
applicable deadline for filing a petition for an administrative hearing. A timely request for
extension of time shall toll the running of the time period for filing a petition until the request is
acted upon.
Mediation
Mediation is not available in this proceeding.
FLAWAC Review
The applicant, or any parry within the meaning of Section 373.114(1)(a) or 373.4275, F.S., may
also seek appellate review of this order before the Land and Water Adjudicatory Commission
under Section 373.114(1) or 373.4275, F.S. Requests for review before the Land and Water
Adjudicatory Commission must be filed with the Secretary of the Commission and served on the
bepartnent within 20 days from the date when the order is filed with the Clerk of the Department.
Judicial Review
Any party to this action has the right to seek judicial review pursuant to Section 120.68, F.S., by
;filing a Notice of Appeal pursuant to Rules 9.110 and 9.190, Florida Rules of Appellate Procedure,
with the Clerk of the Department in the Office of General Counsel, 3900 Commonwealth
Boulevard, M.S. 35, Tallahassee, Florida 32399-3000; and by filing a copy of the Notice of Appeal
accompanied by the applicable filing fees with the appropriate District Court of Appeal. The
Notice of Appeal must be filed within 30 days from the date this action is filed with the Clerk of
the Department.
!Thank you for applying to the Submerged Lands and Environmental Resource Permit Program. If
you have any questions regarding this matter, please contact Emily Powell at the letterhead address
for at (561) 681-6633 or by email at Emily.Powell(d,)floridadep.gov.
Executed in Orlando, Florida.
STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION
elz Je 4 Vey/w-
Christopher Weller
Environmental Manager
Southeast District
File No.: 43-0368903-001,002,003,004-EE
File Name: Mendez
Page 5 of 5
CERTIFICATE OF SERVICE
The undersigned duly designated deputy clerk hereby certifies that this permit and all copies
were sent on the filing date below to the following listed persons:
FDEP — Christopher Weller, Emily Powell
Linda Petz, linenvironAgmail.com
FILING AND ACKNOWLEDGMENT
FILED, on this date, pursuant to Section 120.52, F. S., with the designated Department Clerk,
receipt of which is hereby acknowledged.
October 16, 2018
C erk Date
Enclosures:
Attachment A- Specific Exemption Rule
General Conditions for use of the Federal SPGP V
Project Drawings, 3 pages
Attachment A
62-330.051 Exempt Activities.
The activities meeting the limitations and restrictions below are exempt from permitting. However,
if located in, on, or over state-
owned submerged lands, they are subject to a separate authorization under Chapters 253 and 258,
F.S., and Chapters 18-18, 18-20, and 18-21, F.A.C., as applicable.
(5) Dock, Pier, Boat Ramp and Other Boating -related Work —
(b) Installation of private docks, piers, and recreational docking facilities, and installation of
local governmental piers and recreational docking facilities, in accordance with Section
403.813(1)(b), F.S. This includes associated structures such as boat shelters, boat lifts, and roofs,
1provided:
1. The cumulative square footage of all structures located over wetlands and other surface
waters does not exceed the limitations in Section 403.813(1)(b), F.S.;
2. No structure is enclosed on more than three sides with walls and doors;
3. Structures are not used for residential habitation or commercial purposes, or storage of
materials other than those associated with water dependent recreational use; and
4. Any dock and associated structure shall be the sole dock as measured along the shoreline
for a minimum distance of 65 feet, unless the parcel of land or individual lot as platted is less than
,65 feet in length along the shoreline, in which case there may be one exempt dock allowed per
parcel or lot.
(12) Construction, Replacement, Restoration, Enhancement, and Repair of Seawall,
Riprap, and Other Shoreline Stabilization
(b) The restoration of a seawall or riprap under section 403.813(1)(e), F.S., where:
1 1. The seawall or riprap has been damaged or destroyed within the last year by a discrete event,
such as a storm, flood, accident, or fire or where the seawall or riprap restoration or repair involves
only minimal backfilling to level the land directly associated with the restoration or repair and
does not involve land reclamation as the primary project purpose. See section 3.2.4 of Volume I
for factors used to determine qualification under this provision;
2. Restoration shall be no more than 18 inches waterward of its previous location, as measured
from the waterward face of the existing seawall to the face of the restored seawall, or from the
waterward slope of the existing riprap to the waterward slope of the restored riprap; and
3. Applicable permits under chapter 161, F.S., are obtained.
(d) Installation of batter piles, king piles, or a seawall cap, used exclusively to stabilize and
repair seawalls, provided they do not impede navigation.
J �-
,General Conditions for Federal Authorization for SPGP V
1. The time limit for completing the work authorized ends on July 26, 2021.
2. You must maintain the activity authorized by this permit in good condition and in
conformance with the terms and conditions of this permit. You are not relieved of this requirement if
you abandon the permitted activity, although you may make a good faith transfer to a third party in
compliance with General Condition 4 below. Should you wish to cease to maintain the authorized
activity or should you desire to abandon it without a good faith transfer, you must obtain a
modification of this permit from this office, which may require restoration of the area.
3. If you discover any previously unknown historic or archeological remains while
accomplishing the activity authorized by this permit, you must immediately notify this office of what
you have found. We will initiate the Federal and State coordination required to determine if the
remains warrant a recovery effort or if the site is eligible for listing in the National Register of
Historic Places.
4. If you sell the property associated with this permit, you must obtain the signature of the new
owner on the enclosed form and forward a copy of the permit to this office to validate the transfer of
this authorization.
5. If a conditioned water quality certification has been issued for your project, you must comply
with the conditions specified in the certification as special conditions to this permit.
16. You must allow representatives from this office to inspect the authorized activity at any time
deemed necessary to ensure that it is being or has been accomplished in accordance with the terms
and conditions of your permit.
1 Further Information:
Limits of this authorization.
a. This permit does not obviate the need to obtain other Federal, State, or local authorizations
required by law.
b. This permit does not grant any property rights or exclusive privileges.
c. This permit does not authorize any injury to the property or rights of others.
d. This permit does not authorize interference with any existing or proposed Federal projects.
2. Limits of Federal Liability. In issuing this permit, the Federal Government does not assume
any liability for the following:
a. Damages to the permitted project or uses thereof as a result of other permitted or
unpermitted activities or from natural causes.
b. Damages to the permitted project or uses thereof as a result of current or future activities
undertaken by or on behalf of the United States in the public interest.
c. Damages to persons, property, or to other permitted or unpermitted activities or structures
caused by the activity authorized by this permit.
d. Design or Construction deficiencies associated with the permitted work.
e. Damage claims associated with any future modification, suspension, or revocation of this
permit.
3. Reliance on Applicant's Data: The determination of this office that issuance of this permit is
not contrary to the public interest was made in reliance on the information you provided.
4. Reevaluation of Permit Decision: This office may reevaluate its decision on this permit at any
time the circumstances warrant. Circumstances that could require a reevaluation include, but
are not limited to, the following:
a. You fail to comply with the terms and conditions of this permit.
b. The information provided by you in support of your permit application proves to have
been false, incomplete, or inaccurate (see 3 above).
c. Significant new information surfaces which this office did not consider in reaching the
original public interest decision.
15. Such a reevaluation may result in a determination that it is appropriate to use the suspension,
modification, and revocation procedures contained in 33 CFR 325.7 or enforcement
procedures such as those contained in 33 CFR 326.4 and 326.5. The referenced enforcement
procedures provide for the issuance of an administrative order requiring you comply with the
terms and conditions of your permit and for the initiation of legal action where appropriate.
You will be required to pay for any corrective measures ordered by this office, and if you fail
to comply with such directive, this office may in certain situations (such as those specified in
33 CER 209.170) accomplish the corrective measures by contract or otherwise and bill you
for the cost.
16. When the structures or work authorized by this permit are still in existence at the time the
property is transferred, the terms and conditions of this permit will continue to be binding on
the new owner(s) of the property. To validate the transfer of this permit and the associated
liabilities associated with compliance with its terms and conditions, have the transferee sign
and date the enclosed form.
7. The Permittee understands and agrees that, if future operations by the United States require
the removal, relocation, or other alteration, of the structures or work herein authorized, or if,
in the opinion of the Secretary of the Army or his authorized representative, said structure or
work shall cause unreasonable obstruction to the free navigation of the navigable waters, the
Permittee will be required, upon due notice from the U.S. Army Corps of Engineers, to
remove, relocate, or alter the structural work or obstructions caused thereby, without expense
to the United States. No claim shall be made against the United States on account of any such
removal, relocation or alteration.
Department of the Army Permit Transfer for SPGP V
PERMITEE:
I
PERMIT NUMBER:. DATE:
�ADDRESS/LOCATION OF PROJECT:
(Subdivision) (Lot) (Block)
When the structures or work authorized by this permit are still in existence at the time
property is transferred, the terms and conditions of this permit will continue to be bindinj
Inew owner(s) of the property. Although the construction period for works authorized by
Department of the A y permits is finite the Permit itself, with its limitations, does not E
To validate the transfer of this permit and the associated responsibilities associated wil
compliance with its terms and conditions, have the transferee sign and date below and m:
U.S. Army Corps of Engineers, Enforcement Branch, Post Office Box 4970, Jacksonville
32232-0019.
I
i
(Transferee Signature) (Date)
(Name Printed)
(Street address)
(Mailing address)
I
(City, State, Zip Code)
the
on the
IxUre.
th
ail to the
FL
STANDARD MANATEE CONDITIONS FOR IN -WATER WORK
2011
'The permittee shall comply with the following conditions intended to protect manatees from direct
project effects:_
a. All personnel associated with the project shall be instructed about the presence of
manatees and manatee speed zones, a,nd the need to avoid collisions with and injury to
manatees. The permittee shall advise all construction .personnel that there are civil and
criminal penalties for harming, harassing, or killing manatees which are protected under
the Marine Mammal Protection Act, the Endangered Species Act, and the Florida Manatee
Sanctuary Act.
b. All vessels associated with the construction project shall operate at "Idle Speed/No Wake"
at all times while in the immediate area and while in water where the draft of the vessel
provides less than a four -foot clearance from the bottom. All vessels will follow routes of
deep water whenever possible.
c. Siltation or turbidity barriers shall be made of material in which manatees cannot become
entangled, shall be properly secured, and shall be regularly monitored to avoid manatee
entanglement or entrapment. Barriers must not impede manatee movement.
d. All on -site project personnel are responsible for observing water -related activities for the
presence of manatee(s). All in -water operations, including vessels, must be shutdown if a
manatee(s) comes within 50 feet of the operation. Activities will not resume until the
manatee(s) has moved beyond the 50-foot radius of the project operation, or until 30
minutes elapses if the manatee(s) has not reappeared within 50 feet of the operation.
Animals must not be herded away or harassed into leaving.
e. Any collision with or injury to a manatee shall be reported immediately to the FWC Hotline
at 1-888-404-3922. Collision and/or injury should also be reported to the U.S. Fish and
Wildlife Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-
562-3909) for south Florida, and to FWC at ImperiledSgecies(&-myFWC.com
f. Temporary signs concerning manatees shall be posted prior to and during all in -water
project activities. All signs are to be removed by the permittee upon completion of the
project. Temporary signs that have already been approved for this use by the Florida Fish
and Wildlife Conservation Commission (FWC) must be used (see MyFWC.com/manatee).
One sign which reads Caution: Boaters must be posted. A second sign measuring at least
81/2" by 11" explaining the requirements for "Idle Speed/No Wake" and the shut down of
in -water operations must be posted in a location prominently visible to all personnel
engaged in water -related activities. Questions concerning these signs can be sent to the
email address listed above.
CAUTION: MANATEE HABITAT
All project vessels
IDLE SPEED/NO WAKE
When a manatee is within 50 feet of work
all in -water activities .must
SHUT DOWN
Report any collision with or injury to a manatee:
Wildlife Alert:
1-888-404-FWCC (3922.)
cell * FWC or #FWC
* 4
�O�Tesoa��
UNITED STATES DEPARTMENT OF COMMERCE
National Oceanic and Atmospheric Administration
NATIONAL MARINE FISHERIES SERVICE
Southeast Regional Office
263 13th Avenue South
St. Petersburg, FL 33701
iSEA TURTLE AND SMALLTOOTH SAWFISH CONSTRUCTION CONDITIONS
The permittee shall comply with the following protected species construction conditions:
a. The permittee shall instruct all personnel associated with the project of the potential presence of
these species and the need to avoid collisions with sea turtles and smalltooth sawfish. All
construction personnel are responsible for observing water -related activities for the presence of
these species.
b. The permittee shall advise all construction personnel that there are civil and criminal penalties for
harming, harassing, or killing sea turtles or smalltooth sawfish, which are protected under the
Endangered Species Act of 1973.
c. Siltation barriers shall be made of material in which a sea turtle or smalltooth sawfish cannot
become entangled, be properly secured, and be regularly monitored to avoid protected species
entrapment. Barriers may not block sea turtle or smalltooth sawfish entry to or exit from designated
critical habitat without prior agreement from the National Marine Fisheries Service's Protected
Resources Division, St. Petersburg, Florida.
d. All vessels associated with the construction project shall operate at "no wake/idle" speeds at all
times while in the construction area and while in water depths where the draft of the vessel provides
less than a four -foot clearance from the bottom. All vessels will preferentially follow deep -water
routes (e.g., marked channels) whenever possible.
e. If a sea turtle or smalltooth sawfish is seen within 100 yards of the active daily
construction/dredging operation or vessel movement, all appropriate precautions shall be
implemented to ensure its protection. These precautions shall include cessation of operation of any
moving equipment closer than 50 feet of a sea turtle or smalltooth sawfish. Operation of any
mechanical construction equipment shall cease immediately if a sea turtle or smalltooth sawfish is
seen within a 50-ft radius of the equipment. Activities may not resume until the protected species
has departed the project area of its own volition.
f. Any collision with and/or injury to a sea turtle or smalltooth sawfish shall be reported immediately
to the National Marine Fisheries Service's Protected Resources Division (727-824-5312) and the
local authorized sea turtle stranding/rescue organization.
g. Any special construction conditions, required of your specific project, outside these general
conditions, if applicable, will be addressed in the primary consultation.
h. Any collision(s) with and/or injuries to any whale, or sturgeon occurring during the construction of
a project, shall be reported immediately to NMFS's Protected Resources Division (PRD) at (727-
824-5312).
t
I �
i. Reports to NWS's Protected Resources Division (PRD) may be made by email to
takergport.mnfsser(@—noaa.gov.
j. Sea turtle and marine stranding/rescue organizations' contact information is available by region at
hM://www.nmfs.noaa.goy/pr/health/networks.htm.
k. Smalltooth sawfish encounters shall be reported to
http•//www flmnh ufl edu/fish/sharks/sawfish/sawfishencounters.html.
1. All work must occur during daylight hours.
— - -- --
- - - -
-
—NOTES:-- I- - - - --
1. King (vertical) pilings: min. 4, max. 5
3'
Kin Pilin s
2. Batter (angled) pilings: min. 3, max. 5
max. '± OC
3. Concrete 5000 psi
Waterbody:
4. Number of king 8dor batter pilings to
Artificial canal off -of
, . 7., pr
°pew
be field located/determined.
the Indian River
Proposed
5. Dock not to attach to seawall.
Width: varies 100'±
Dock
�� �� a
6. New seawall to be within 18" face
9.5'
�•'
face of existing.
Proposed Dock Area
>1 3''�'
over MHW:
`r�=
88± sq.ft.
Prop sed
r
Boa Lift
'r ±
Mendez Residence
10701 S. Ocean Dr., Lot 809
`.s
Jensen Beach, FL 34957
Batter Pilings
max. 10'± OC
(Angled 4:1± @
panel midpoint)
18" of
ing
IIIIIIIIIIIIIIIIIIIII
0' 10, 20'
4;he Scale
Proposed Mendez Residence Proposed Wilco Construction, Inc. Date: 7/17/18
Plan View Seawall, Dock, & Boat Lift (772)460-6928;FAX(772)460-6929
TYPICAL DOCK AND ACCESSWAY CROSS SECTION
(N.T.S.)
The work specified herein
has been designed and all
work shall be in
accordance
with the 2017 Florida
Building Code (6th Edn.).
All codes reference herein
are per the latest adopted
edition.
STRINGERS:
2"x8" 0.4 or 0.6 ACQ space
at max. 24" with min.1/2" S
lag bolts on each piling (lap
spliced)
Blocks:
To be added as needed:
2"x6"xl2" 0.4 ACQ strap
blocks @mid stringers
(fastened w/min. 3 ea.
min. 3" SS screws/nails)
6' min.
penetration
•
Width: As Exists
Decking:
2"x6" Tropical Decking
0.4 ACQ #1 Decking fastened
w/min. 3" stainless steel screws
Nails Typical
Joist: —�
As exists or if replE
to be,
2"x8" 0.4 ACQ on
each side of piling.
Bolted w/ 5/8"
SS cut rods.
AMT
M.L.W.
CANAL BOTTOM
Pilings:
min. 8" 0, 2.5 CCA
PT wood,
max. 10' OC
L-j
P
Cross View
Mendez Residence-
Wilco Construction,
�
P
9! 1
Structural
Inc.Dock
NOTE:
1. concrete to have a min. Compressive Strength of
5000 psi @ 28 days.
2. Install new concrete seawall directly in front
of existing seawall, within 18" face to face.
3. Pilings final hammer driven to a min. of 5 tons each
4. Pilings to be 12"x12" prestressed concrete up to 20' length.
5. Plat width is 35'#
6. King Wor Batter pilings may be field located, as needed.
7. Elevation of new seawall cap to be field located.
r-Liftina Hooks
#5 Bar
He
and
The work specified herein
tt as een esigned and all
work shall be in accordant
with the 2017 Florida
Building Code (6th Ed.).
All codes reference herein
are per the latest adopted
edition.
#3 Ties
a2' O.C-
New Concrete Panel
(8" thick x 10' wide x 12' long)_
King Pile 12"x12"
prestressed
(Vertical at panel seams)
Backfill Between
Existing Sit
A', New Pa
Min.3'+/- Fmb.dment
for P nela S
Mendez Residence
10701 S. Ocean Dr., Lot 809
Jensen Beach, FL 34957
King pile @
panel seam
(vertical)
Enlarged New Seawall for the Mendez
Cross Property (Lot 809)
Section
--b PCs
#/57Ba/4^fig^+/-
i�
Expanded ^ '
King Pile
min.3" ncrete
coverage verrebar
8t,+P#5
Lar
rebar ties
@2' OC
yr .
/
, "IP
dowel with std.
hook epoxy-
12"x12" King
�.:,
set min. embedme
Cont. Pil
6" 2 pc. per pile
Pile (angled 4:1+/-
1.0 50%min.
4 '( penetration
for pilings
<1B (face
to face) 12"x12" Concrete Pilings
35'+/- New
Concrete Cap/Wall
i ies
2' OC
after pile
@ panel midpoint
(angled 4:1+/-)
^--`-xtile Filter
along backside
yard side) of wall
pile @
panel seam
(vertical)
Expanded
Batter Pile
,rate
-age pcs`
3bar� 74t�i/ c--
14,,=3reb.rties2' OC
12"x12" Batter
Conc. Pile
Wilco Construction, Inc.
(772)460-6928; Fax (772)460-6929
�del with std.
hook eowpox
y-
: set min. embedme
6" 2 pc. per pile
Date: 7/17/18
Scale:
Dim