HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFING.1 iIIf Product Approval
P3 USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL20484-R1
Revision
2017
Approved
UNION CORRUGATING COMPANY
701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 483-0479 Ext256
jstieby@unioncorrugating.com
SCANNED
BY
St Lucie County
John Stieby
jstieby@unioncorrugating.com o( 3/
ST. WifflE COUNTY RUTLDT. G DIVISION
REVIEWED FOR CO
REVIEWED BY -
IDATE,� . KEPT ON ]GAB
PLANS AND PEki' • W'1LL BE MADE
SITE OR NO INSPE CN(�)
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
n Evaluation Report - Hardcopy Received
Bala Sockalingam
PE-62240
Keystone Certifications, Inc.
09/07/2027
Yoosef Lavi, P.E.
r Validation Checklist - Hardcopy Received
FL20484 RI COI CertificateIndependence.odf
Referenced Standard and Year (of Standard) Standard
FM 4470
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2012
2003
2012
2006
Product Approval Method Method 1 Option D
Date Submitted
08/23/2017
Date Validated
08/28/2017
Date Pending FBC Approval
09/01/2017
Date Approved
12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
20484.1
5V
Min 26 ga., 24" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReportC2175 l.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-169
Evaluation Reports
Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c. &
FL20484 R1 AE Eva] uationReportC2175 S.pdf
169.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.2
Advantage-Lok II
Min 26 ga., 16" wide concealed fastened panel over 7/16" thick
OSB & 15/32" & thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReoortC2175 2.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116
Evaluation Reports
Other: Maximum uplift load of 116.0 psf @ seam fastener
FL20484 R1 AE Eva IuationReoortC2175 2.odf
spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA
Created by Independent Third Party: Yes
rated plywood with retainer strap.
20484.3
Aluminum Advantage-Lok II
Max 16.375" wide, nom 0.032" thick (min.) aluminum
concealed fastener roof panel over min 15/32" thick plywood
deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReportC2175 3.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c.
FL20484 R1 AE Eva IuationReportC2175 3.odf
and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32"
Created by Independent Third Party: Yes
plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener
spacing of 4.63" o.c. with structural sealant in 15/32" plywood.
20484.4
Aluminum SL150
Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock
standing seam metal panel over min 15/32" thick plywood
deck or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReportC2175 4.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86
Evaluation Reports
Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and
FL20484 R1 AE Eva luationReoortC2175 4.0
78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16"
Created by Independent Third Party: Yes
OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with
structural sealant in 15/32" plywood.
20484.5
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReoortC2175 5.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Design Pressure: +N/A/-124
Created by Independent Third Party: Yes
Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. &
FL20484 R1 AE EvaluationReoortC2175 5.0f
124.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.6
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluatlonReoortC2175 6.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-88.5 Evaluation Reports
Other: Uplift load of 56 psf for Fastening System 1. Uplift load FL20484 R1 AE Evaluation Repo rtC2175 6.odf
of 88.5 psf for Fastening System 2. Created by Independent Third Party: Yes
20484.7
ML150
Max 16.5" wide, min 24 ga. steel standing seam panel over
15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReportC2175 7.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Maximum uplift load of 124 psf @ clip spacing of 6"
FL20484 R1 AE EvaluationReportC2175 7.pdf
o.c, with 180 seam, self -adhering membrane and fixed.clip.
Created by Independent Third Party: Yes
20484.8
PER or R Panel
Min 26 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RS II EvaluationRenortC2175 8.1)df
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c.
FL20484 R1 AE EvaluationReportC2175 8.Ddf
and 1.61.5 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.9
SL175
Max 18" wide, min 24 ga., snap -lock standing seam metal
panel over 15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReportC2175 9.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c, and
FL20484 R1 AE EvaluationReoortC2175 9.pdf
78.6 psf @ clip spacing of 8" o.c with felt. Uplift load of 93.5
Created by Independent Third Party: Yes
psf @ clip spacing of 12" o.c. with self -adhering membrane.
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
FOR ECIfEd:
Credit
Safe