Loading...
HomeMy WebLinkAboutNOA - CONCRETE FLAT ROOF TILEMIAMI-DADE COUNTY 4lAM PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE(NOA) www.miamidade.eov/economy Entegra Roof Tile, LLC RECEIVED SCANNED 1289 NE 91 Ave NOV0 � 20i8 �� Okei chobee, FL. 34972 St LIIC)1r c®ul}� SCOPE: L Lucie County, Permitting This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This fNOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in 1Vlianiai-Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such iproduct or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. : Bermuda Concrete Flat Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. I TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the mate �'als, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for salesadvertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section f this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed byrl n expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be do in its 'entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shag be available for inspection at the job site at the request of the Building Official. LU This NvOA renews NOA No. 14-1120.06 and consists of pages Lthrough 6. The submitted documentation was reviewed by Gaspar J Rodriguez. I NOA No.16-0112.07 Mwrat•naoecounirr Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 1 of 6 r" 2. 2.1 2.2 The Inc. The Inc. The Inc. The Inc. The Inc. The Inc. ASSEMBLY APPROVAL :gory: Roofing Category: Roofing Tiles eriah Concrete SCOPE This approves a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description pra Flat Tile Length =16" TAS 112 Flat profile, interlocking, high pressure extruded Width =10" Type 3a concrete roof tile equipped with two nail holes. Class III For mechanical, mortar or adhesive set applications. Pieces 1= varies TAS 112, Accessory trim, concrete roof pieces for use at w = varies hips, rakes, ridges and valley terminations. varying thickness Manufactured for each file profile. MANUFACTURING LOCATION 1. Okeechobee, FL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) ter for Applied Engineering, 94-084 Static Uplift Testing May 1994 PA 101 (Mortar Set) ter for Applied Engineering, 94-060A Static Uplift Testing March, 1994 PA 101(Adhesive Set) ter for Applied Engineering, 25-7094-2 Static Uplift Testing PA 102 Oct. 1994 (4" Headlap, Nails, Direct Deck, New Construction) ter for Applied Engineering, 25-7094-8 Static Uplift Testing PA 102 Oct. 1994 (4" Headlap, Nails, Battens) ter for Applied Engineering, 25-7094-5 Static Uplift Testing PA 102 Oct. 1994 (4-'Headlap, Nails, Direct Deck, Recover/Reroof) ter for Applied Engineering, 25-7183-6 Static Uplift Testing PA 102 Feb. 1995 (2 Quik-Drive Screws, Direct Deck) NOA No.16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 2 of 6 2.2 EVIDENCE SUBNIITTED Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The enter for Applied Engineering, Inc. Technologies Technologies Technologies Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering, Inc. Service Industries, Inc. Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Wal6r Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineers American Test Lab of South Florida Test Identifier Test Name/Report Date 25-7183-5 Static Uplift Testing Feb. 1995 PA 102 (2 Quik Drive Screws, Battens) 25-7214-1 Static Uplift Testing March, 1995 PA 102 (1.Quik Drive Screw, Direct Deck) 25-7214-5 Static Uplift Testing March, 1995 PA 102 (1 Quik Drive Screw, Battens) 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II PA 108 (Nail -On) .Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 PA 108 (Nail -On) P0631-01 Wind Tunnel Testing July 1994 PA 108 (Mortar Set) P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs. smooth shank nails Project No. 307025 Wind Driven Rain . Oct. 1994 Test #MDC-77 PA 100 R1.894 Physical Properties Aug. 1994 R2.894 PA 112 R3.894 395-40011-1 Physical Properties Feb 2004 PA 112 520109-1 Static Uplift Testing Dec. 1998 5201114 PA 101 520191-1 Static Uplift Testing March 1999 PA 101 Calculations Aerodynamic Multiplier March 2004 Evaluation Calculations 25-7094 Feb 1996 Evaluation Calculations 25-7496 April 1996 Evaluation Calculations 25-7584 December 25-7804b-8 1996 25-7804-4 & 5 25-7848-6 Evaluation Calculations 25-7183 March 1995 Evaluation Calculations Restoring Moment, Mg March 2004 Calculations Two Patty Adhesive Set System April 1999 13343.1 TAS 112 05/06/08 RT1210.02-15 TAS 112 12/17/15 NOA No.16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 3 of 6 3. 4. LmTATIONS: Fire classification is not part of this acceptance. For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. INSTALLATION 4.1 Entegra `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight W (Ibf) Length -I (ft) 1 Width-w (ft) 1 Ente 'ra Flat Tile 9.7 1.33 .833 Table 2: Aerodynamic Multipliers - A. (W) Tile Profile a, (ft3) Batten Application (ft3) Direct Deck Application Ente ra Flat Tile 0.189 0.205 Table 3: Restoring Moments due to Gravity - Mg (ft-lbf) Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Entegra Flat Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.53 6.97 6.43 6.86 6.29 6.71 6.14 6.54 5.97 6.35 NOA No.16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 4 of 6 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems (Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min.19/32" plywood) Battens Entegra Tile Flat 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 50.3 65.5 48.3 1 Installation with a 4" file headiap and fasterners are located a min. of 2Y2" from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Ent ra Flat Tile Adhesive 31.33 2 S e manufactures component approval for installation requirements. 3 F 3M'' exible Products Company TileBond Average weight per patty 13.9 grams. 2-Component Foam Roof Tile Adhesive AH-160. Average weight pera 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Entegra Flat Tile I 310' 2-Component Foam Roof Tile Adhesive AH-160 118.94 3M'" 2-Component Foam Roof Tile Adhesive AH-160 40.45 4 Large paddy placement of 45 grams of 3M'" 2-Component Foam Roof Tile Adhesive AH-160 5 Medium paddy placement of 24 grams of W 2-Component Foam Roof Tile Adhesive AH-160 NOA No.16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 5 of 6 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". c� ENTEGRA FLAT TILE LABEL (LOCATED ON UNDERSIDE OF TILE) ING PERMIT REQUIREMENTS: As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be. used to obtain a building permit. PROFILE DRAWING ENTEGRA"FLAT" CONCRETE ROOF TILE 16• _I 10, \1 FIELD TILE — 16' , THICK BUTT TILE END OF THIS ACCEPTANCE NOA No.16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 6 of 6