HomeMy WebLinkAboutNOA - CONCRETE FLAT ROOF TILEMIAMI-DADE COUNTY
4lAM PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE(NOA) www.miamidade.eov/economy
Entegra Roof Tile, LLC RECEIVED SCANNED
1289 NE 91 Ave NOV0 � 20i8 ��
Okei chobee, FL. 34972 St LIIC)1r c®ul}�
SCOPE:
L
Lucie County, Permitting
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This fNOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in
1Vlianiai-Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such iproduct or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
: Bermuda Concrete Flat Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
I
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
mate �'als, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
salesadvertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section f
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed byrl n
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be do
in its 'entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shag
be available for inspection at the job site at the request of the Building Official. LU
This NvOA renews NOA No. 14-1120.06 and consists of pages Lthrough 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
I
NOA No.16-0112.07
Mwrat•naoecounirr Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 1 of 6
r"
2.
2.1
2.2
The
Inc.
The
Inc.
The
Inc.
The
Inc.
The
Inc.
The
Inc.
ASSEMBLY APPROVAL
:gory: Roofing
Category: Roofing Tiles
eriah Concrete
SCOPE
This approves a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as
determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared
as a moment based system.
PRODUCT DESCRIPTION
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
pra Flat Tile
Length =16"
TAS 112
Flat profile, interlocking, high pressure extruded
Width =10"
Type 3a
concrete roof tile equipped with two nail holes.
Class III
For mechanical, mortar or adhesive set
applications.
Pieces
1= varies
TAS 112,
Accessory trim, concrete roof pieces for use at
w = varies
hips, rakes, ridges and valley terminations.
varying thickness
Manufactured for each file profile.
MANUFACTURING LOCATION
1. Okeechobee, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
PA 102 & PA 102(A)
ter for Applied Engineering,
94-084
Static Uplift Testing
May 1994
PA 101 (Mortar Set)
ter for Applied Engineering,
94-060A
Static Uplift Testing
March, 1994
PA 101(Adhesive Set)
ter for Applied Engineering,
25-7094-2
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Direct Deck, New
Construction)
ter for Applied Engineering,
25-7094-8
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Battens)
ter for Applied Engineering,
25-7094-5
Static Uplift Testing PA 102
Oct. 1994
(4-'Headlap, Nails, Direct Deck,
Recover/Reroof)
ter for Applied Engineering,
25-7183-6
Static Uplift Testing PA 102
Feb. 1995
(2 Quik-Drive Screws, Direct Deck)
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 2 of 6
2.2 EVIDENCE SUBNIITTED
Test Agency
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The enter for Applied Engineering,
Inc.
Technologies
Technologies
Technologies
Technologies
The Center for Applied Engineering,
Inc.
Atlanta Testing & Engineering, Inc.
Service Industries, Inc.
Corporation Testing Service
Celotex Corporation Testing Service
Walker Engineering, Inc.
Wal6r Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Nutting Engineers
American Test Lab of South Florida
Test Identifier
Test Name/Report
Date
25-7183-5
Static Uplift Testing
Feb. 1995
PA 102
(2 Quik Drive Screws, Battens)
25-7214-1
Static Uplift Testing
March, 1995
PA 102
(1.Quik Drive Screw, Direct Deck)
25-7214-5
Static Uplift Testing
March, 1995
PA 102
(1 Quik Drive Screw, Battens)
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix II
PA 108 (Nail -On)
.Letter Dated Aug. 1,
Wind Tunnel Testing
Aug. 1994
1994
PA 108 (Nail -On)
P0631-01
Wind Tunnel Testing
July 1994
PA 108 (Mortar Set)
P0402
Withdrawal Resistance Testing of screw
Sept. 1993
vs. smooth shank nails
Project No. 307025
Wind Driven Rain
. Oct. 1994
Test #MDC-77
PA 100
R1.894
Physical Properties
Aug. 1994
R2.894
PA 112
R3.894
395-40011-1
Physical Properties
Feb 2004
PA 112
520109-1
Static Uplift Testing
Dec. 1998
5201114
PA 101
520191-1
Static Uplift Testing
March 1999
PA 101
Calculations
Aerodynamic Multiplier
March 2004
Evaluation Calculations
25-7094
Feb 1996
Evaluation Calculations
25-7496
April 1996
Evaluation Calculations
25-7584
December
25-7804b-8
1996
25-7804-4 & 5
25-7848-6
Evaluation Calculations
25-7183
March 1995
Evaluation Calculations
Restoring Moment, Mg
March 2004
Calculations
Two Patty Adhesive Set System
April 1999
13343.1
TAS 112
05/06/08
RT1210.02-15
TAS 112
12/17/15
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 3 of 6
3.
4.
LmTATIONS:
Fire classification is not part of this acceptance.
For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control
Section for review.
Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
INSTALLATION
4.1 Entegra `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight W (Ibf)
Length -I (ft)
1
Width-w (ft)
1
Ente 'ra
Flat Tile
9.7
1.33
.833
Table 2: Aerodynamic Multipliers - A. (W)
Tile
Profile
a, (ft3)
Batten Application
(ft3)
Direct Deck Application
Ente
ra Flat Tile
0.189
0.205
Table 3: Restoring Moments due to Gravity - Mg (ft-lbf)
Tile
Profile
3":12"
4":12"
5":12"
6":12"
Greater than
7":12"
Entegra
Flat Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.53
6.97
6.43
6.86
6.29
6.71
6.14
6.54
5.97
6.35
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 4 of 6
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail -On Systems
(Tile
Profile
Fastener Type
Direct Deck
(min 15132" plywood)
Direct Deck
(min.19/32" plywood)
Battens
Entegra
Tile
Flat
2-10d Ring Shank Nails
30.9
38.1
17.2
1-10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
2-10d Smooth or Screw
Shank Nails
14.0
18.8
7.4
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or Screw
Shank Nail Field Clip)
24.3
24.3
24.2
1-10d Smooth or Screw
Shank Nail Eave Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
2-10d Ring Shank Nails' 50.3 65.5 48.3
1 Installation
with a 4" file headiap and fasterners are located a min. of 2Y2" from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Ent
ra Flat Tile
Adhesive
31.33
2 S
e manufactures component approval for installation requirements.
3 F
3M''
exible Products Company TileBond Average weight per patty 13.9 grams.
2-Component Foam Roof Tile Adhesive AH-160. Average weight pera 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Entegra Flat
Tile I
310' 2-Component Foam Roof Tile Adhesive AH-160
118.94
3M'" 2-Component Foam Roof Tile Adhesive AH-160
40.45
4 Large paddy
placement of 45 grams of 3M'" 2-Component Foam Roof Tile Adhesive AH-160
5 Medium paddy placement of 24 grams of W 2-Component Foam Roof Tile Adhesive AH-160
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 5 of 6
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
c�
ENTEGRA FLAT TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
ING PERMIT REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be. used to obtain a building permit.
PROFILE DRAWING
ENTEGRA"FLAT" CONCRETE ROOF TILE
16• _I
10,
\1
FIELD TILE
— 16' ,
THICK BUTT TILE
END OF THIS ACCEPTANCE
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 6 of 6