Loading...
HomeMy WebLinkAboutREVISION - UNDERLAYMENTSCREEK 0ATLAS ROOFING CORPORATION `' �p Roofing Underiayments TECHNICAL°SEFiVIC ES, LLC SCANNED WIND RESISTANCE (NON-HVHZ ONLY) ..B w _ The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9 Underlayment System No.1 — WeatherMaster® Tile only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherlVlaster® Tile shall be fully adhered to the optiona� ¢plywood �`. Maximum Design -52.5 psf � r EIIWPEC Pressure: CODE COMPLIANCE LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. BOCC 2) Roof slope limitations shall be in accordance with FBC requirements. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Products described within this report may be used as described in other current FBC product approval documents. 5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents. 6) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT 1 The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. �® E IV. Rd No 74021 b o .' v...�.., ...,.12:44: 2 ® STATE OF .• QJ It .40 R ! O�*Zachary R. Priest, P.E. ®®� F 'r 0 Aq as Florida@ Organ iation No.I on ANE96 1021 I FICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distribut . products under this evaluation. i CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products and this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products a under this evaluation. .crr Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of product. END OF REPORT Im F0 P TL14001.4A FL17322-R4 page 4 : aw y evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CR 4 nical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is val' _ evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that ar ifically addressed herein. - i ATLAS ROOFING CORPORATION Roofing Underlayments APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck sh®Il,b .., I din eco. f ce with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15. Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for than 24 hours may adversely affect product performance b) ' WeatherMaster® Ice and Water 100, WeatherMaster® Ice and Water 200, and WeatherMaster® Ice and Water 216 — maximum 30 days o c) WeafherMaster® Pro -Grade Ice and Water and WeatherMaster® Flexible Ice and Water — maximum 30 days d) WeatherMaster® Tile — maximum 90 days Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMaster® Pro -Grade Ice and Water or WeatherMaster® Tile — ICP Adhesives Polyset AH-160 b) Slate/Tile Underlayment or #90 Mineral Surface Roll Roofing — Convenience Products Touch n' Seal Storm Bond Roof Tile Adhesive, Dow TileBond, or ICP Adhesives Polyset AH-160 Alinwahla Rnnf r.nvarinns- Metal Roof " Comp®site-or - ' ° wood . , Asphalt _ Panels and Photovoltaic Shingles and . Slate - Clay and, .M Underlayment Shin les Shingles Shire Is$..• Shakes' Shingles Concrete Tile ' #15 Specification Felt Y Y Y Y2 Y N #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y 943 Base Sheet Y Y Y N Y Y #90 Mineral Surface Roll Roofing Y' N N N N Y Gorilla Guard® EVERFELT 30 Y Y Y YZ Y N Slate/Tile Underlayment Y' N N N N Y WeatherMaster@ Ice and water Y Y Y N Y N 100 weatherMaster@ Ice and water Y Y Y N Y N 200 weatherMasterO Ice and water Y Y Y N Y N 216 weatherMaster® Flexible Ice and Y Y Y N Y N Water weatherMaster@ Pro -Grade Ice Y Y Y N Y N and water VWeatherMasterG Tile Y Y Y N Y Y Notes: 1) Open valley applications per 1507.2.9.2 ,s. 2) Wood shingles only ATL14001.4A FL17322-R4 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CRE Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is % This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are specifically addressed herein. A,>, ATLAS ROOFING CORPORATION CREEK Roofing Underlayments 'TEC3-fNICA.L. SERVICES, L,L.0 I PRODUCT DESCRIPTION #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the non-HVHZ only. 030 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. 943 Ease Sheet ASTM D 2626 asphalt saturated and coated, non -perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. i ##90 Mineral Surface Roll ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the Roofing HVHZ and non-HVHZ. Gorilla Guard® EVERFELT 30 Asphalt -saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ and non-HVHZ. Slate/Tile Underlayrnent ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMaster@ Ice and Water 100 ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster@ Ice and Water 200 ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@ Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@ Flexible Ice ASTM D 1970 SBS modified, self -adhering underlayment with plastic film surface and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. !WeatherMaster@ Pro -Grade ASTM D 1970 SBS modified, self -adhering underlayment with a fiberglass mat !Ice and Water reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster@ Tile TAS 103 SBS modified, self -adhering underlayment with a fiberglass mat reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. REVIEWED FOR CODE COMPLPANCE ST. LUCIE COUNTY B®CC ATL14001.4A FL17322-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TF-CH-HH"+AAC@"9.1La I-R'X icEs, LLC EVALUATION REPORT Manufacturer: ATLAS ROOFING CORPORATION 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770)612-6267 www. atlasroofin d.com Quality Assurance: UL LLC (QUA9625) SCOPE Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, 6TH EDITION (2017) Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Issued September 30, 2017 Enti Report No. Standard Year PRI Construction Materials Technologies (TST6049) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) ATL-068-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-068-02-01 ASTM D 4798 2011(2016) PRI Construction Materials Technologies (TST6049) ATL-068-02-01 TAS 110 2000 PRI Construction Materials Technologies (TST6049) ATL-069-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-090-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) ATL-149-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-164-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) WRMI-011-02-01 ASTM 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-030-02-01 ASTM D 1970 2015a UL LLC (TST1740) 02-NI<40952 ASTM D 1970 2015a UL LLC (TST1740) 02-NK40952 ASTM D 226 2009 UL LLC (TST1740) 02-NK40952 ASTM D 2626 2004(2012)E1 UL LLC (TST1740) 02-NK40952 ASTM D 4869 2016 UL LLC (TST1740) 02-NK40952 ASTM D 6380 2003 (2013) ATL14001AA FL17322-R4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CRE Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v; This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are specifically addressed herein. Palm 0tv. FL a4990 Install] Depils: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE' -86 PSF PSF �, -101 PSF 7228 PSF ROW SPACINGii 16°' ®c 16" O.C. R99 D.C.6B9 ox. FASTENER SPACING (ALONG banal width) f 12" ox 12" a.c. 12° ox. 12" ox. FASTENER SIZE #9 #10 #10 #10 ReferOnce Data: ARCHITECTURAL TESTING, INC. TST I®#: 1527 UL 560r06 & 1897-041 Test Report 693.01-450-18 05102/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQVI�ALENCY UL .9819.7-04 is equivalent to hest standard UL 18971? *Deskgn pressure margin of safety 2.1 - Locke Bowden, P.E. does not have, not will acquire a financial in or distributing products ILI under this evaluation. o `✓ � A R , . a Locke Bowden, P.E. is not owned, operated, or controlled by any coaipar(Vpmbbdia4tureF, or dastributing products sander this report. 0 p uw ; � 4 iiVIEWED FOR ���tl;,�� b �' �5, , „CODE COMPLIANCE AM,� � + ST. LUCIE COUNTY 1MN Aft PBOCC FL17022.1 5V Crimp (26GA Steel), 24" Fide Roof Panel m Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t" ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. �1 GZI or greater Plywood, or - Wood plank 247 arS N'111 Nominal 12" O.C. Panel Profile Nominal 12" O.C. Fasten E9 x 1-1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Panel Refer to Table "A" for Spacing Along Panel Overlap Length - Deck-15/32" or greater Plyviood, or -VUbod plank