WIND RESISTANCE (NON-HVHZ ONLY) ..B w _
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9
Underlayment System No.1 — WeatherMaster® Tile only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherlVlaster® Tile shall be fully adhered to the optiona� ¢plywood
�`.
Maximum Design -52.5 psf � r EIIWPEC
Pressure:
CODE COMPLIANCE
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation. BOCC
2) Roof slope limitations shall be in accordance with FBC requirements.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Products described within this report may be used as described in other current FBC product approval
documents.
5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other
current FBC product approval documents.
6) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
1 The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
�® E IV. Rd
No 74021
b o .' v...�.., ...,.12:44: 2
®
STATE OF .• QJ
It
.40
R ! O�*Zachary R. Priest, P.E.
®®� F 'r 0 Aq as Florida@ Organ iation No.I on ANE96 1021
I
FICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distribut .
products under this evaluation.
i
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products and
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products a
under this evaluation. .crr
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of
product.
END OF REPORT
Im F0 P
TL14001.4A FL17322-R4 page 4 : aw y
evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CR 4
nical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is val' _
evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that ar
ifically addressed herein. - i
ATLAS ROOFING CORPORATION
Roofing Underlayments
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
sh®Il,b .., I din eco. f ce with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
Exposure of the underlayments shall be limited to a maximum 30 days except as follows:
a) #15. Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for than 24 hours may
adversely affect product performance
b) ' WeatherMaster® Ice and Water 100, WeatherMaster® Ice and Water 200, and WeatherMaster® Ice
and Water 216 — maximum 30 days
o c) WeafherMaster® Pro -Grade Ice and Water and WeatherMaster® Flexible Ice and Water — maximum
30 days
d) WeatherMaster® Tile — maximum 90 days
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as
indicated in other current FBC product approval documents):
a) WeatherMaster® Pro -Grade Ice and Water or WeatherMaster® Tile — ICP Adhesives Polyset AH-160
b) Slate/Tile Underlayment or #90 Mineral Surface Roll Roofing — Convenience Products Touch n' Seal
Storm Bond Roof Tile Adhesive, Dow TileBond, or ICP Adhesives Polyset AH-160
Alinwahla Rnnf r.nvarinns-
Metal Roof "
Comp®site-or
- ' ° wood . ,
Asphalt _
Panels and
Photovoltaic
Shingles and .
Slate -
Clay and, .M
Underlayment
Shin les
Shingles
Shire Is$..•
Shakes'
Shingles
Concrete Tile '
#15 Specification Felt
Y
Y
Y
Y2
Y
N
#30 Organic Saturated Felt
Y
Y
Y
Y
Y
N
#30 Specification Felt
Y
Y
Y
Y
Y
Y
943 Base Sheet
Y
Y
Y
N
Y
Y
#90 Mineral Surface Roll Roofing
Y'
N
N
N
N
Y
Gorilla Guard® EVERFELT 30
Y
Y
Y
YZ
Y
N
Slate/Tile Underlayment
Y'
N
N
N
N
Y
WeatherMaster@ Ice and water
Y
Y
Y
N
Y
N
100
weatherMaster@ Ice and water
Y
Y
Y
N
Y
N
200
weatherMasterO Ice and water
Y
Y
Y
N
Y
N
216
weatherMaster® Flexible Ice and
Y
Y
Y
N
Y
N
Water
weatherMaster@ Pro -Grade Ice
Y
Y
Y
N
Y
N
and water
VWeatherMasterG Tile
Y
Y
Y
N
Y
Y
Notes: 1) Open valley applications per 1507.2.9.2
,s.
2) Wood shingles only
ATL14001.4A FL17322-R4
3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CRE
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is %
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are
specifically addressed herein.
A,>,
ATLAS ROOFING CORPORATION
CREEK Roofing Underlayments
'TEC3-fNICA.L. SERVICES, L,L.0
I
PRODUCT DESCRIPTION
#15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#30 Organic Saturated Felt
ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the
non-HVHZ only.
030 Specification Felt
ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
943 Ease Sheet
ASTM D 2626 asphalt saturated and coated, non -perforated, organic felt
underlayment for use in the HVHZ and non-HVHZ.
i
##90 Mineral Surface Roll
ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the
Roofing
HVHZ and non-HVHZ.
Gorilla Guard® EVERFELT 30
Asphalt -saturated organic felt underlayment reinforced with glass fiber that meets
the performance requirements of ASTM D 226, Type I for use in the HVHZ and
non-HVHZ.
Slate/Tile Underlayrnent
ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the
HVHZ and non-HVHZ.
WeatherMaster@ Ice and
Water 100
ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster@ Ice and
Water 200
ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split -release film, which is removed during
installation.
WeatherMaster@ Ice and
ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
Water 216
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split -release film, which is removed during
installation.
WeatherMaster@ Flexible Ice
ASTM D 1970 SBS modified, self -adhering underlayment with plastic film surface
and Water
for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a
split -release film, which is removed during installation.
!WeatherMaster@ Pro -Grade
ASTM D 1970 SBS modified, self -adhering underlayment with a fiberglass mat
!Ice and Water
reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster@ Tile
TAS 103 SBS modified, self -adhering underlayment with a fiberglass mat
reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
REVIEWED FOR
CODE COMPLPANCE
ST. LUCIE COUNTY
B®CC
ATL14001.4A FL17322-R4 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TF-CH-HH"+AAC@"9.1La I-R'X icEs, LLC
EVALUATION REPORT
Manufacturer: ATLAS ROOFING CORPORATION
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770)612-6267
www. atlasroofin d.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, 6TH EDITION (2017)
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1
Properties:
Physical properties
REFERENCES
Issued September 30, 2017
Enti
Report No.
Standard
Year
PRI Construction
Materials Technologies (TST6049)
ATL-033-02-01
ASTM D 226
2009
PRI Construction
Materials Technologies (TST6049)
ATL-068-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
ATL-068-02-01
ASTM D 4798
2011(2016)
PRI Construction
Materials Technologies (TST6049)
ATL-068-02-01
TAS 110
2000
PRI Construction
Materials Technologies (TST6049)
ATL-069-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
ATL-090-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST6049)
ATL-149-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
ATL-164-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
BWR-533-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST6049)
BWR-543-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
MSA-004-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
MSA-007-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST6049)
MSA-026-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
WRMI-011-02-01
ASTM 1970
2015a
PRI Construction
Materials Technologies (TST6049)
MSA-007-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST6049)
MSA-030-02-01
ASTM D 1970
2015a
UL LLC (TST1740)
02-NI<40952
ASTM D 1970
2015a
UL LLC (TST1740)
02-NK40952
ASTM D 226
2009
UL LLC (TST1740)
02-NK40952
ASTM D 2626
2004(2012)E1
UL LLC (TST1740)
02-NK40952
ASTM D 4869
2016
UL LLC (TST1740)
02-NK40952
ASTM D 6380
2003 (2013)
ATL14001AA
FL17322-R4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CRE
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v;
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are
specifically addressed herein.
Palm 0tv. FL a4990
Install] Depils: Table A Allowable Loads
METHOD 1
METHOD 2 METHOD 3
METHOD 4
DESIGN PRESSURE'
-86 PSF
PSF
�, -101 PSF
7228 PSF
ROW SPACINGii
16°' ®c
16" O.C.
R99 D.C.6B9
ox.
FASTENER SPACING (ALONG banal width) f
12" ox
12" a.c.
12° ox.
12" ox.
FASTENER SIZE
#9
#10
#10
#10
ReferOnce Data: ARCHITECTURAL TESTING, INC. TST I®#: 1527
UL 560r06 & 1897-041 Test Report 693.01-450-18 05102/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQVI�ALENCY UL .9819.7-04 is equivalent to hest standard UL 18971? *Deskgn pressure margin of safety 2.1
-
Locke Bowden, P.E. does not have, not will acquire a financial in or distributing products
ILI
under this evaluation. o `✓ � A R , . a
Locke Bowden, P.E. is not owned, operated, or controlled by any coaipar(Vpmbbdia4tureF, or dastributing products sander this
report. 0
p uw
; � 4 iiVIEWED FOR
���tl;,�� b �' �5, , „CODE COMPLIANCE
AM,� � + ST. LUCIE COUNTY
1MN Aft
PBOCC
FL17022.1 5V Crimp (26GA Steel), 24" Fide Roof Panel m Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t" ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
�1 GZI or greater Plywood, or
- Wood plank
247
arS
N'111
Nominal 12"
O.C.
Panel Profile
Nominal 12"
O.C.
Fasten
E9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Wdth
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
- Deck-15/32" or greater
Plyviood, or
-VUbod plank