HomeMy WebLinkAboutROOF ATTACHMENTS.024 ALUM ROCF .024 ALUM ROOF
2' RIDGED POLYSTYRENE INSULATION 2' RIDGED POLYSTYRENE INSULATION
EXISTING MOBILE HOME ROOF EXTRUDED ALUM. ATTACK RAIL, EXISTING PATIO ROOF
--wl#8X14/4S.M.S.TO.Q—
BUIYLRUBBERSEAL
024 ALUM FLASHING
BUTYL RUBBER SEAL
UDEDALUMI.
CH RAIL
vd ##BRXi 11144 S.MS. 3' D.C.
2X3 P.T. W/#BX3' WS. @ 9' D.C. r 0pq ALUM ROOF 2X3 P.T. w1#8X3' W.S. Q S. O.C.
INTO EXISTING EACH FRAME INSULATION /
' 2X3 P.T. BLOCKS CUT TO FIT INTO
PANS wi (2) #B S.M.S. PER PAN
EXTRUDED ALUM. ATTACH RAIL .024 RIDGE ALUM ROOF CONIT. KuurFACTORY
R FILE
CODV
w1 #8X7114 S.M.S. 3' O.C. FASCIA EDGE DETAIL OR RIDGE WI FACTORY SEAMS ®46' O.C.�BIlTYLRUBDERSEAL__ _GIRTEfZEDG_EDETAILCOACr1ANDPAT10
�024 ALUM FLASHING INTO PAN CONNECTION DETAILS
AND CAULK OR CONTINU'c : / `\ _ FOAM INSULATION
FLASHINGTOGUTTER I ®L, _ ________________
2 #B SMS w1 YEOPR NE i / INSULATION ' -, ® 1 .024 ALUM ROOF
WASHERS TO TOP OF EACH P N 1
1`� T EXISTING
MOBILEHCMEROOF SINGLE WIDE (NTS)
1
I PATIO PAN ROOF
- --EY.STING COACH- '/
FRAME ,/ -- — lCOLYSTYRENEFOAM
EXISTING ALUM INSERT E:•CH PAN
EXISTING PATIO ROOF COL R BEAM .
EXISTING WALL CHO;lNEL .024 ALUM R
ALTERNATE COACH & PATIO ROOF ATTACHMENT #1 ALTERNATE PATIO PAN ROOF AT IACHMENT DETAIL "A". YtiDGEDPOLYSTYRENEINSULATION
CONNECTION DETAIL (NTS) (NO 4th WALL) N.T.S. —' EXSTING MOBILE HOME ROOF
EXTRUDED ALUM. ATTACH RAIL . r
.024ALUM ROOF w/1114S.M.S.3'O.C,
#SX
.024 ALUM ROOF 309 FELT ON TOP OF BUTYL RUBBER SEAL
'I PANS / 1
Y RIDGED POLYSTYRENE JNSULATION .024 ALUM FLASHING INTO PAN
EXISTING MOBILE HOME ROOF EXTRUDED ALUM. ATTACH RAIL AND CAULK OR CONTINUE
FLASHING TO GUTTER 2X3 P.T. WI.AX3' W.S. @ 6' 0
w/#8X1114S.M.S.3'O.C.
-' 1 _ '= T INTO EXISTING COACH FRAM
BUMRUBBERSEAL i � ��i�T 2-#8S!ASwINEOPRi:iJc
_ WASHERS TO TOP OF EACH PAIJ
1 i i
.024ALUM ROOF.FLASHING
EXTRUDED ALUM. ATTO,CH RAIL
w/#8X11/4 S.M.S. 3' O.C.
2X3 P.T. W/ #8X3' W.S. @ 6O.C.
INTO EXISTING ROOF FRAME
BUTYL RUBBER SEAL
024 ALUM ROOF
30# FELT ON TOP OF
PANS
2X3 P.T. BLOCKS CUT TO FIT INTO
PANS w/(2) #8 S.M.S. PER PAN
emu' �i'fi
EXISTING PANS wl `
EXISTING COACH
INSULATION INSERTS
FRAME
EXISTING ALUM.
_ COL BBEAM
i
ALTERNATE COACH & PATIO ROOF ATTACHMENT #2
CONNECTION DETAIL (NTS) (w/4th WALL)
.024 ALUM I
T RIDGED POLYSTYRENE INSULATION'
a*TRUDEDALUM,ATTACH RAIL
w/#8X1114 S.M.S. 3' O.C.
,,-BUIYLRUBBER SEAL
2X3 P.T. W/#NC!' W.S. I
INTO EXISTINGCOACH
FRAME ��� `EXISTING PATIO ROOF
MAX 8' SPAN 14'•
TAPERED INSULATION AS REQUIREDL
EXISTING WALL CHANNEL
EXISTING PANS w/ —�
INSULATION INSERTS
2X3 P.T. BLOCKS CUT TO FIT II
PANS w% (2) #8 S.M.S. PER PAN
m
EXISTING
OVERHANG u
•EXISTINGAIUM. POLYSTYRENE FOAM
COL 8 BEAR INSERT EACH PAN
ALTERNATE PATIO PAN ROOD ATTACHMENT DETAIL"B"
N.T.S.
BUTYL RUBBER SEAL
EXTRUDED ALUM. ATTACH R'4L
///
2' RIDGED POLYSTYRENE INSULATION -EXTRUDED
S.M.S. T O.C.
U4ERLAPPING 2X3 P.T. w/ 9BX3'
.024 ALUM ROOF - W.S. @ 3. O.C.
FOAM FILLER '
EXISTING CENTER CAP STING COACH FRAMING
DOUBLE WIIJE RiDF DETAI:.
N.T.S.
BUTYL RUBBER SI
Y RIDGED POLYSTYRENE INSULATION
OVERLAPPING
.024 ALUM ROOF
EXISTING COACH
FRAME
-- — iS'PTCAD OOF SECTN.T.S.
#84W STAINLESS STEEL NIX HEAD
FROM A17ACHMENT RAIL TO EXISTING
MODILZE HOME FRAME @ S O.C. MIN.
INTO c7C.'STING FRAMING
EXTRUDED ALUM.
ATTACHRAIL 1/a5d'KIDEBUT&RUBBER CONT.
wl#8X1INSM.S.3'D.C. •024ROLL ALUMINUM
INSULATION
/--BUTYLRUBBERSEAL RCOf-�
`024 ALUM GUTTER '
W/ STRAPS @"O.C.
P_`I ITTCD C11/'+I- I1CTA11
.024 ALUM R
2' RIDGED POLYSTYREn= INSULATION
EXISTING MODILE PG'aE ROOF-7
/i- EXTRUDED ALUM. ATTACH RAIL
w/#64%S.M.S. T O.C.
P.T. IWI) BLOCKwI
#w-,,Y.S. @ SPANNING
TO STRAIGHTEN WOOD ONLY
2X3 P.T.:Nl
INTO EXISTL TG CQACH FRAME
ZU'TING COACH
FRAME
ALTERNATE COACH & PATIO ROOF ATTACHMENT #3 EXISTING CENTER CAP-/ _mSTINGCOACHFRAMING
CONNECTION DETAIL (NTS) (NO DROP BETWEEN ROOFS) DOUBLE WIDE RIDGE DETAIL
USING ALTERNATE #1 ATTACHMENT (NTS)
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C
ST. LUGIt Luulm
REVIEWED FOR (
REVIEWED BY_
DATE____N
PLANS AND PERI
SITE OR NO INS
EXTRUDED ALUM. ATTACI I RAIL
wl #3X11/4 S.M.S. T O.C.
ATTACH CONT. 2 AV P.T. TO EXSTING
MCBILE HOME FRAMING WI #BTO' WOOD
SCREWS @ SPACING TO STRAIGHTEN
WOOD ONLY, IN LIEU OF FULL FRAMING
ATTACHMENTPER DELJLS
PATIO ROOF
7
r X
NOTE: THISALTER14ATE
MAY BE USED M OMIT IN.
PROGRESS INSPECTIONS
OF FRANIM
Y BE—NNECTION
!ZISC"K
AIRNATECON
O
Z
O
U
L EXTRUDED ALUMINUM ATTACHMENT
RAIL w/ 98XI-1/4 STAINLESS STEEL
SCREWS @ 5' O.C. INTO
EXSTING MOBILE HOME
PRE -PUNCHED HOLES.
FRAMING d ROOFING
ALTERNATE ATTACHMENT RAIL FASTENING #1
N.T.S.
IG V DIVISION '
024 GALVALUME CLEAT
48- O.C. (TYP)
D� VViLL DC 1.4r% - el�Wul
.024•ALUM t`uA, _ c
®4'nhtSTYRENE-BUTADIENE
.FACTORY SEAM DESIGN FOR RUBBER SEALANT
ALUMINUM ROOF COVERINGS: BETWEEN SHEET & CLEAT
OVER SOLID ROOFS ONNIPRODLICT APPROVAL #FL5739- R�
024 ALUM FASCIA
N.T.S.
�ATADJACENT PATIO ROOF
NOTES:
PROY:DE .024 FLASHING
INTO PATIO ROOF RdIN 81
1) THIS DESIGN CONFORMS TO THE 201 ORRIDAA BUiLDING CODE FOR A
'BU�IL'DI� FOR WIA�DING OF 185'MP'H-,,rEXPOSURE•CAS
wl#B SYS @ IT O.C.
w9DETERMINED'l3Y ASCE STANDARD 7.
2 i hiS DESIGN CONFOrZ4rS70 FL'ORLDA STATUTE 15C-2.0081 FOR
EXISTING EXTRUDED WALL CHANNEL
MOBILE/MANUFACTURED HOME REPAIR AND REMODELING.
3.) ALUMINUM ROOFING iS DESIGNED FOR USE OVER A SOLID ROOF ONLY. IT
SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM.
4.) THE ROOF COVERING SHALL NOT OVI=RHANC THE EXISTING ROOF.
5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING
ROOF. THE -STRUCTURE OF THE EXISTING ROOF SHOULD BE ABLE TO
SUPPORT THE CONSTRUCTION LOADING -FOR THE NEW ROOF SYSTEM.
ra C'IA ELsGE DETAIL ° ) MAXIMUM WIDTH OF A DOUBLE WD E MOBILE EMOBILE HOME NOT TEXCEED 1 HOME NOT EXCEED 22'-0
N.T.S. B ) INSULATiCN TO BE POLYSTYRENE FORM APROX DENSITY 1# PER S.F.
9.) MAXIMUM HEIGHT OF MOBILE HOME NOT TO EXCEED 1&-0'.
10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .024 ALUM.
11.) THE R-VALUE OF THE 2' EPS INSULATION IS R=S.7. '
' SHEET No.: S1 of 2
OWNER: r'rF-CLT '� (_� ����� '' NOT VALID UNLESS DATED
8 SEALED WITH EMBOSSED
ADDRESS: k3 ®'��A W A NGINEER L r -
STATE: r_-16— 21P: .3�—
L(o �l uOl l Z
LOT# BLOCK# RANGE: AM
SHOU S BUSE, P.E..
PROFESSIONAL ENGINEER 20311 0
STATE OF FLORIDA
W
Q
y�co
q
�H
:g
co
w
qo
H
`o
�
b
cm4�
rOb
W�
�0
r °�►
'
� Ce' �i
-
V�
.94O
va,
O a b
yyO�tA
O
w
4
0
Y
s
U
EXTRUDED ALUM. ATTACH RAIL
w/ #BX1 1/4 S.M.S. 3' O.C.
12'x12'x.024 ALUM CAP
RUBBER SEAL
2'x4' PT CONT. w/ #8x3' WOOD SCREWS @ 6'
O.C. TO RIDGE BEAM & 148x3" WOOD
SCREW TO EACH TRUSS
.024 ALUM ROOF-
Y RIDGED POLYSTYRENE
INSULATION
3' MIN THICK BONDED PANEL
NOTE:
MAX 17 SPAN BONDED PANEL
EXISTINGALUM.
COL & BEAM
OR FRAMING
BONDED
- N.T.S. .
r,
EXTRUDED ALUM. ATTACH RAIL
wl #BX11/4 S.M.S. 3' O.C.
BUTYLRUBBERSEAL "
25L1' PT wl #145' TEX SCREWS @ r O.C. THRU
BONDED PANEL INTO EXISTING BEAM'
.024 ALUM FLASHING
�EXTRUDED ALUM. ATTACH RAIL
wl #BX1114 S.M.S. 3' O.C.
BUTYL RUBBER SEAL
--.024 ALUM FLASHING
T MAX. O.H.
EXISTING .
OVERHANG
ROOF EDGE DETAI
2' RIDGED POLYSTYRENE DQRUDED ALUM. ATTACH RAIL
INSULATION wl#BX11/4 S.M.S. T O.C.
BUTYLRUBBERSEAL ¢
.024 ALUM FLASHING.
r
— MAX 26' WIDTH
\ \ .024 ALUM
ri -,
r
RIDGED POLYSTYRENE INSULATION
—2-x4- WOOD TRUSS @
24'0.C. w/ 1/2' SHEATHING
EXTRUDED ALUM. ATTACH RAIL
w/#BX1 1/4 S.M.S. 3' O.C.
BUTYL RUBBER SEAL
SEE GUTTER &
FASCIA EDGE
DETAILS,-S-1
j
2x4 P.T. wl #BX3'WOOD SCREWS
@ 6- O.C. TO FASCIA w/ 1-#BW- r
MAX 18' O.H.--I
TO EACH TRUSS TAIL @ 24.O.C.
CONTINUOUS
2' FASCIA TYP.
t'AKK MUUtL Ut I AIL A
N.T.S.
NOTE:
NOTES ARE TYPICAL FOR BOTH SIDES OF ROOF
EXTRUDED ALUM. ATTACH RAIL 3 w/#BX1 1/4 S.M.S. ' O.C.
12'x12'x 024 ALUM CAP
LAP OF ROOF ROLL TO BE ON
DOWNWARD SIDE
3' MIN THICK BONDED PANEL—' 2V PT wl #8:3' SMS @ 4' INTO
NOTE: ` EXTRUDED METAL & BONDED PANEL
MAX 17 SPAN BONDED PANEL
1, MAX O.H.
032 EXTRUDED FASCIA
EXISTING ALUM. EXISTING OR GUTTER
COL. & BEAM j OVERHANG
OR FRAMING \\\\\
BONDED PANEL ROOF EDGE DETAIL #1
N.T.S.
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C
MAX 14' WIDTH
PARK MODEL DETAIL B
N.T.S.
w o
m 03
U � 07 �
� M �
ca N
y c�
� m w
0.
4�
O
Z
LLI
O
p.
U
YL RUBBER SEAL
2'x4' PT CONT. w/ 2-#BX3' WOOD SCREWS TO. EACH TRUSS
�Wc
.024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION
2-x4' WOOD TRUSS @
iv,24'O.C. w/ 1/2' SHEATHING EXTRUDED ALUM. ATTACH RAIL V w
cq
w/ #BX1 1/4 S.M.S. 3O.C. C)
BUTYL RUBBER SEALcb
lo
//j///foe, SEE GUTTER j/ & FASCIA EDGETel c
DETAILS, S-1
co 0
2x4 P.T. w/ #8x3'WOOD SCREWS 0 4
MAX 1B" O.H.—� @ 12- O.C. TO FASCIAw/ 1-18x3'CNZ
TO EACH TRUSS TAIL @ 24.O.C.
CONTINUOUS
2' FASCIA TYP.
b
NOTE: E, C *
FIRESTONE ISO 95+ GL INSULATION BOARD MAY cl) to
03
BE USED IN LIEU OF THE POLYSTYRENE
INSULATION BOARD IN THE SAME 2' THICKNESS. [Ns,
.w
C
co
SHEET No.: S2 Of 2
rq
OWNER: NOT VALID UNLESS DATED
'7
a'
A SEALED WITH EMBOSSED
ADDRESS: ENGINEFrRS EAL
CITY: STATE: 21P: 4ts.
Z
in
se
LOT# BLOCK# RANGE: AMES BUSHOUSE, P.E.
p
V
ROFESSIONALENGINEER20311.
STATE OF FLORIDA