HomeMy WebLinkAboutPRODUACT APPROVAL - MODIFIED BITUMENBG5 MOme Log in User Registration ? Hot Topicsi Submit Surcharge I Stats & Facts i Publications FBC Staff 505 Site Map Links Search
Fit lida
xaxr
'
Product Approval
4-1
USER; Public User
RECEIVE®
d
,
Product Anoroval Mcnu > Product or Aooliation
Search > Aoofiration List > Application Detail
NOV 13 2018
+
FL #
FL1654-R22
ST. Lucie County, PAYP1il£iit1q
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments /�// �
Archived ST. LU IE COUNTYQ�LDING DIVISION
REVIEWELyj
MAN,
Product Manufacturer POLYGLASS USA REVIEWEBY
Address/Phone/Email 150 Lyon Drive DATE
Fernley, NV 89408 PLANS AND PT BE KEPT ON JOB
(570) 384-1230 Ext �fTE OR NO IN(S) WILL BE MADE
jakins@ polyg lass.com
Authorized Signature James Akins
jakins@polyglass.com NOV 14 2018
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive E
Deerfield Beach, FL 33442 Copy
(912)429-8610
MAlpert@polyglass.com
Quality Assurance Representative Ariel Lender SCANNED,
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442 St Lucie County
(954)233-1230 9
ALend er@ polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W. Knezevich, PE
4' Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1654 R22 CO1 2017 01 COI Nieminen.odf
Standard
Year
ASTM D6162
2008
ASTM D6163
2008
ASTM 06164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/14/2017
Date Validated 09/15/2017
Date Pending FBC Approval 09/22/2017
Date Approved 12/12/2017
Summary of Products
r x
2012
FL # Modelr Number or Name
Description
1654.1 Polyglass SBS and APP Modified
SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use
Installation Instructions ^�
Approved for use in HVHZ: No
FL1654 R22 11 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
R22.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular assembly over concrete
deck. Refer to the ER Appendix for other systems and
FL1654 R22 AE 2017 09 FiNAL ER POLYGL.ASS MODBIT FL1654-
deck types. 2.) Refer to ER, Section 5 for other Limits
R22.odf
of Use.
Created by Independent Third Party: Yes
Hark Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone; 850.487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida. Privacy Statement ;: Accessibility Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this'entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. +Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Credit Card
,Safe
, aq
Table
Deck _.
Application
Type
Description
Pa e 8
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
16-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
30-11
1C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
11
1D
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
IF-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
1F-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates); Bonded Roof Cover
19-21
1G
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
21
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover _
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, ,Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
38
Structural concrete
New or Reroof (Tear -Off)
F
Non -insulated, Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
48
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
48
5C
CWF
New, Reroof (Tear -Off) or Recover
B
_
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached insulation, Bonded Roof Cover
49
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
49
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
50-52
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
52
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
6D
Gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
54-58
76
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
58
The following notes apply to the systems outlined herein-
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-RZZ
Certificate of Authorization #9503 6`N EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polygiass Modified Bitumen Roof Systems; (570) 3WI230 Appendix 1, Page 1 of 58
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
-.,.
i k p \ ygapyi?-:yyiR rr' D 04 „4 : e P `P«' ., .„.� M+a d `c 'kK�` Y 3: F ?2'` W:' .L�o +' _ 5''W-_ ' k.a@ae..,u x- 1:
} x''xt tip. 3`l m• w,"�4 .M':;`f ` > qai Y p`XeS:4�: -:,.. Syt.''xN,"wj +�.i. •w'.� m2:3 a'4.'Y •C'.#' ' •: ..✓..`:'i''�'7..:.
i -: •v }R.: }�,;^° 'yIy {R
�Va' X
°..P"'.ro'�if'*"ao J .?°'..ye
l„
,�v�hm:.-] 2.`^ _. .sue A ✓C� ia4'A'' >a "A-'i �# •�rl %A.. e
...�".� <<A i 3a a, .. .... ^��M� �.- •k=t. S.-xk a �A. a«N� A� XrwRr�t� �ete 3,..sfi...�.A;
„�l sd- .. "R a�G- :..-
e..bFi �.ew N�in.S#'
Reference
Layer
Material _
Application
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type 11
(Base and Ply sheets, Asphalt-
Hot Asphalt at 20-40
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Applied)
PP )
Note;
As halha lied sheets or insulation shall not be applied topoly-film su aced membranes.
P PR PP surfaced
Ibs/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 Type 11, Polyglass HT Base 650
SBS-CA1
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type 11, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield
PG350 at 1.5-2.0
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II
SBS-CA2
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type 11, Elastoflex S6 G, Elastoflex S6 GFR, Elastoshield TS-G, Elastoshield '
Polyplus 35 at 1.5-2.0
Cap Ply
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
gal/square
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex
Base Ply or Ply
S6 Type II, Polyglass HT Base 650
SBS-AA
Hot Asphalt at 20-40
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
(SBS, Asphalt -Applied)
Cap Ply
Elastoshield TS-G FR, Polyfresko G 505 (sand -backed), Polyfresko G SBS FR (sand -backed)
Ibs/square
Note:
Asphalt -applied sheets or Insulation shall not be applied to poly film surfaced membranes.
Oneor more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex 56, Elastoflex 56 Type II, Polyglass HT Base
Base Ply or Ply
0
SBS-TA
(SBS, Torch -Applied)
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
Torch -Applied
Ca Pl
p y
Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
SBS-SA
(SBS, Self -Adhering)
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Note;
Elastobase (poly/sand) or Elastobose (poly/poly).
APP-CA3
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
(APP, Torch -Applied)
Torch -Applied
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP-SA
Unless otherwise noted, permissible membrane substrates forAYP=SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
(APP, Self -Adhering)
Note:
Elastobase (poly/sand) or Elastobase (polyjpoly).
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with mating usage.
Y PG200 Non Fibered Roof Coating;
)v- PG300 Fibered Roof Coating;
Y PG600 Non-Fibered Aluminum Roof Coating;
Y PG650 Fibered Aluminum Roof Coating;
Y PG700 High Quality Elastomeric Roof Coating or KM Acry125;
Y PG7000S (Quick set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only);
F PG800 Asphalt Emulsion Roof Coating;
Y Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
Y Polyplus 65 Premium Fibered Aluminum Roof Coating;
Y Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
➢ Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or SBS only);
Y Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, LLC, d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization f19503 6n' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20! 09/12/2017
Prepared by; Robert Nierninen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 3 of 58
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements,
18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs, those in Table 3A
applies: .
e-_
_ .�
Vapor Barrier
Option #
insulation Adhesive
MDP (psf)f
Primer
Type
Attach
V13-1.
PG100
Elastoflex SA V Plus
Self -Adhering _
'nta-Stik or.CR-20, 12-inch o.c.
-60,0
_VB-2.
PG100
Poiygiass APP Base
Torch -applied
':nta-Stik or CR-20, 12-inch o.c.
-75.0
VB-3,
PG100
Elastoflex SA P
Seif-Adhering
insta-Stik,12-inch o.c.
-75.0
VB-4,
PG100
Elastoflex SA P
Self -Adhering
Millennium One Step Foamabie Adhesive,12-inch o.c.
-157.5
VB-S.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-6.
PG100
Elastoflex SA V Base, Elastoflex SA V FR Base,
Self -Adhering
Millennium One Step Foamabie Adhesive, Millennium PG-1 Pump Grade
290.0
Elastoflex SA V Plus, Elastoflex SA V Plus FR
Adhesive, OlyBond 500 or CR-20,12-inch o.c.
19. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report P9290,02.08-1120 for FL1654-R22
Certificate of Authorization #9503 6" EDITION (2017)'FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polygiass Modified Bitumen Roof Systems, (570) 394-1230 Appendix 1, Page 4 of 58
L",
VrTRINITYIERD
to
z;4z
2T�.<,...00
�a�A0*11111
_.,. x2"
.w...*.
00- MINi�h.
tt_K{/�{s�y
- n1A.-mwna�.e J .s.TL
,M <.
3,s.'bSS;*.E�
System
Insulation Layer(s)
Base Sheet
Roof Cover (Note 15)
MDP
No.
Deck (Note 1)
Type
Attach
Type
Fasten
Attach
Base Ply
Cap Ply
(Psf)
Min IS/32•—_
-.
One or more 1
kelim.-----
OMG #12 Standard Roofgrip or OMG #14
6-inch o.c, at 4-inch lap and 6-inch
(Optional) BP -AA,
r-SBS=M;SBS=-
-
Aayers,:any -, _ i^
-�
-
. Elastobas``e, EiasCotiase'P--_
--Heavy-Duty with OMG3" Round Mefai—_
--o.c_-in-five_(5),_equaily spaced,
SBS-AA,.SBS-TA,,- _
.
120.0-
`_�
=Inch plywood
combination
Attached
_--_
Plates or OMG Flat Bottom Metal Plates
staggered center rows-
APP-TA" -
TA or APP-TA
Min. 15/32-
One or more
Prelim.
OMG #12 Standard Roofgrip or OMG #14
6-inch o.c, at 4-inch lap and 6-inch
W-67
inch plywood
layers, any
Attached
Polyglass APP Base
Heavy Duty with OMG 3" Round Metal
o.c, in five (5), equally spaced,
(Optional) APP TA
APP-TA
-120.0
combination
Plates or QMG Flat Bottom Metal Plates
staggered center rows
, a
>. :z
* -
„
5.-._�<, 9er ram. xt •sY
,$" x. A., ++�`
,.v:., , a z ,< .t. '1O s.�-' a , i3 w.na
i a4,:
a-:w. �'w,'.,'' �,at: q..� ,'�< w'e�"..^`
a+,>Y%%.'.,' k4k .�
; . '° , 5��, �,".
�k.A' =3. 3 < m
k,3, *k
,� •�a'e�w �;
,C�,i c„+,,,
,�%a,,,%. •.,.s>3¢,1 ;`p
'• Lt
L'",+
�,
Min.19/32-
One or more
Prelim.
Elastobase, Elastobase P (poly-
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
12-inch o.c. in 4-inch lap and 12-
SBS-SA, APP-
W-68
inch plywood
layers, any
Attached
film top)
Dekfast #14 or Trufast 3' Metal Insulation
inch o.c. in two, equally spaced,
SBS-SA
SA, SBS-TA or
-52.5`
combination
Plate with Trufast HD
staggered center rows
APP-TA
Min.19/32-
One or more
Prelim.
Elastobase, Elastobase P (poly-
Dekfast Hex (aka, Dekfast PLI'-H-2-7/8) with
12-inch o.c. in 4-inch lap and 12-
W-69
inch plywood
layers, any
Attached
film top)
Dekfast #14 or Trufast3" Metal Insulation
inch o.c. in two, equally spaced,'
Polyflex SA Base
APP-TA
-52.5"
combination
Plate with Trufast HD
staggered center rows
Min. 19J32-
One or more
Prelim.
Elastobase, Elastobase P (poly-
OMG Fiat Bottom Plates (square) with
12-inch c.c. in 4-inch lap and 12-
SBS-SA, APP-
W-70
inch plywood
layers, any
Attached
film top)
Roofgrip #12
inch o,c, in two, equally spaced,
SBS-SA
SA, SBS-TA or
-60.0`
combination
staggered center rows
APP-TA
Min. 19/32-
One or more
Prelim.
Elastobase, Elastobase P (poly-
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-
W-71
inch plywood
layers, any
Attached
film top)
Roofgrip #12
inch o.c, in two, equally spaced,
Polyflex SA Base
APP-TA
-60.01
combination
I
I
I
I staggered center rows
Exterior Research and Design, I.I.C. d/b/a Trinity ) ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polygiass Modified Bitumen Roof Systems, (570) 384-1230 Appendix 1, Page 15 of 58