Loading...
HomeMy WebLinkAboutPRODUACT APPROVAL - MODIFIED BITUMENBG5 MOme Log in User Registration ? Hot Topicsi Submit Surcharge I Stats & Facts i Publications FBC Staff 505 Site Map Links Search Fit lida xaxr ' Product Approval 4-1 USER; Public User RECEIVE® d , Product Anoroval Mcnu > Product or Aooliation Search > Aoofiration List > Application Detail NOV 13 2018 + FL # FL1654-R22 ST. Lucie County, PAYP1il£iit1q Application Type Revision Code Version 2017 Application Status Approved Comments /�// � Archived ST. LU IE COUNTYQ�LDING DIVISION REVIEWELyj MAN, Product Manufacturer POLYGLASS USA REVIEWEBY Address/Phone/Email 150 Lyon Drive DATE Fernley, NV 89408 PLANS AND PT BE KEPT ON JOB (570) 384-1230 Ext �fTE OR NO IN(S) WILL BE MADE jakins@ polyg lass.com Authorized Signature James Akins jakins@polyglass.com NOV 14 2018 Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive E Deerfield Beach, FL 33442 Copy (912)429-8610 MAlpert@polyglass.com Quality Assurance Representative Ariel Lender SCANNED, Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 St Lucie County (954)233-1230 9 ALend er@ polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE 4' Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL1654 R22 CO1 2017 01 COI Nieminen.odf Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM 06164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 UL 1897 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/14/2017 Date Validated 09/15/2017 Date Pending FBC Approval 09/22/2017 Date Approved 12/12/2017 Summary of Products r x 2012 FL # Modelr Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions ^� Approved for use in HVHZ: No FL1654 R22 11 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654- R22.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular assembly over concrete deck. Refer to the ER Appendix for other systems and FL1654 R22 AE 2017 09 FiNAL ER POLYGL.ASS MODBIT FL1654- deck types. 2.) Refer to ER, Section 5 for other Limits R22.odf of Use. Created by Independent Third Party: Yes Hark Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone; 850.487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida. Privacy Statement ;: Accessibility Statement:: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this'entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. +Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card ,Safe , aq Table Deck _. Application Type Description Pa e 8 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 16-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 30-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached insulation, Bonded Roof Cover 12-13 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15 IF-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-18 1F-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates); Bonded Roof Cover 19-21 1G Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 21 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22-24 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover _ C Mech. Attached Insulation, Bonded Roof Cover 25-28 2C Steel or Structural concrete New, ,Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 32-40 38 Structural concrete New or Reroof (Tear -Off) F Non -insulated, Bonded Roof Cover 40 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 48 LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48 5C CWF New, Reroof (Tear -Off) or Recover B _ Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 49 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached insulation, Bonded Roof Cover 49 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 50-52 6B Gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 53 6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 54-58 76 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 58 The following notes apply to the systems outlined herein- 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-RZZ Certificate of Authorization #9503 6`N EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polygiass Modified Bitumen Roof Systems; (570) 3WI230 Appendix 1, Page 1 of 58 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. -.,. i k p \ ygapyi?-:yyiR rr' D 04 „4 : e P `P«' ., .„.� M+a d `c 'kK�` Y 3: F ?2'` W:' .L�o +' _ 5''W-_ ' k.a@ae..,u x- 1: } x''xt tip. 3`l m• w,"�4 .M':;`f ` > qai Y p`XeS:4�: -:,.. Syt.''xN,"wj +�.i. •w'.� m2:3 a'4.'Y •C'.#' ' •: ..✓..`:'i''�'7..:. i -: •v }R.: }�,;^° 'yIy {R �Va' X °..P"'.ro'�if'*"ao J .?°'..ye l„ ,�v�hm:.-] 2.`^ _. .sue A ✓C� ia4'A'' >a "A-'i �# •�rl %A.. e ...�".� <<A i 3a a, .. .... ^��M� �.- •k=t. S.-xk a �A. a«N� A� XrwRr�t� �ete 3,..sfi...�.A; „�l sd- .. "R a�G- :..- e..bFi �.ew N�in.S#' Reference Layer Material _ Application BP -AA Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type 11 (Base and Ply sheets, Asphalt- Hot Asphalt at 20-40 Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Applied) PP ) Note; As halha lied sheets or insulation shall not be applied topoly-film su aced membranes. P PR PP surfaced Ibs/square Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 Type 11, Polyglass HT Base 650 SBS-CA1 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type 11, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield PG350 at 1.5-2.0 gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II SBS-CA2 Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type 11, Elastoflex S6 G, Elastoflex S6 GFR, Elastoshield TS-G, Elastoshield ' Polyplus 35 at 1.5-2.0 Cap Ply TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) gal/square One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex Base Ply or Ply S6 Type II, Polyglass HT Base 650 SBS-AA Hot Asphalt at 20-40 Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, (SBS, Asphalt -Applied) Cap Ply Elastoshield TS-G FR, Polyfresko G 505 (sand -backed), Polyfresko G SBS FR (sand -backed) Ibs/square Note: Asphalt -applied sheets or Insulation shall not be applied to poly film surfaced membranes. Oneor more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex 56, Elastoflex 56 Type II, Polyglass HT Base Base Ply or Ply 0 SBS-TA (SBS, Torch -Applied) Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Torch -Applied Ca Pl p y Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Cap Ply Elastoflex SA P, Elastoflex SA P FR, Polyreflect SBS-SA (SBS, Self -Adhering) Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, Self -Adhering Note; Elastobase (poly/sand) or Elastobose (poly/poly). APP-CA3 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond (APP, Torch -Applied) Torch -Applied Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR Cap Ply Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool APP-SA Unless otherwise noted, permissible membrane substrates forAYP=SA are limited to the SBS-SA Base Ply options herein, Self -Adhering (APP, Self -Adhering) Note: Elastobase (poly/sand) or Elastobase (polyjpoly). 16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with mating usage. Y PG200 Non Fibered Roof Coating; )v- PG300 Fibered Roof Coating; Y PG600 Non-Fibered Aluminum Roof Coating; Y PG650 Fibered Aluminum Roof Coating; Y PG700 High Quality Elastomeric Roof Coating or KM Acry125; Y PG7000S (Quick set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only); F PG800 Asphalt Emulsion Roof Coating; Y Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; Y Polyplus 65 Premium Fibered Aluminum Roof Coating; Y Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; ➢ Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or SBS only); Y Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. Exterior Research and Design, LLC, d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-R22 Certificate of Authorization f19503 6n' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20! 09/12/2017 Prepared by; Robert Nierninen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 3 of 58 17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements, 18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs, those in Table 3A applies: . e-_ _ .� Vapor Barrier Option # insulation Adhesive MDP (psf)f Primer Type Attach V13-1. PG100 Elastoflex SA V Plus Self -Adhering _ 'nta-Stik or.CR-20, 12-inch o.c. -60,0 _VB-2. PG100 Poiygiass APP Base Torch -applied ':nta-Stik or CR-20, 12-inch o.c. -75.0 VB-3, PG100 Elastoflex SA P Seif-Adhering insta-Stik,12-inch o.c. -75.0 VB-4, PG100 Elastoflex SA P Self -Adhering Millennium One Step Foamabie Adhesive,12-inch o.c. -157.5 VB-S. PG100 Elastoflex SA P Self -Adhering CR-20, 12-inch o.c. -270.0 VB-6. PG100 Elastoflex SA V Base, Elastoflex SA V FR Base, Self -Adhering Millennium One Step Foamabie Adhesive, Millennium PG-1 Pump Grade 290.0 Elastoflex SA V Plus, Elastoflex SA V Plus FR Adhesive, OlyBond 500 or CR-20,12-inch o.c. 19. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report P9290,02.08-1120 for FL1654-R22 Certificate of Authorization #9503 6" EDITION (2017)'FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polygiass Modified Bitumen Roof Systems, (570) 394-1230 Appendix 1, Page 4 of 58 L", VrTRINITYIERD to z;4z 2T�.<,...0­0 �a�A0*11111 _.,. x2" .w...*. 00- MINi�h. tt_K{/�{s�y - n1A.-mwna�.e J .s.TL ,M <. 3,s.'bSS;*.E� System Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Attach Type Fasten Attach Base Ply Cap Ply (Psf) Min IS/32•—_ -. One or more 1 kelim.----- OMG #12 Standard Roofgrip or OMG #14 6-inch o.c, at 4-inch lap and 6-inch (Optional) BP -AA, r-SBS=M;SBS=- - Aayers,:any -, _ i^ -� - . Elastobas``e, EiasCotiase'P--_ --Heavy-Duty with OMG3" Round Mefai—_ --o.c_-in-five_(5),_equaily spaced, SBS-AA,.SBS-TA,,- _ . 120.0- `_� =Inch plywood combination Attached _--_ Plates or OMG Flat Bottom Metal Plates staggered center rows- APP-TA" - TA or APP-TA Min. 15/32- One or more Prelim. OMG #12 Standard Roofgrip or OMG #14 6-inch o.c, at 4-inch lap and 6-inch W-67 inch plywood layers, any Attached Polyglass APP Base Heavy Duty with OMG 3" Round Metal o.c, in five (5), equally spaced, (Optional) APP TA APP-TA -120.0 combination Plates or QMG Flat Bottom Metal Plates staggered center rows , a >. :z * - „ 5.-._�<, 9er ram. xt •sY ,$" x. A., ++�` ,.v:., , a z ,< .t. '1O s.�-' a , i3 w.na i a4,: a-:w. �'w,'.,'' �,at: q..� ,'�< w'e�"..^` a+,>Y%%.'.,' k4k .� ; . '° , 5��, �,". �k.A' =3. 3 < m k,3, *k ,� •�a'e�w �; ,C�,i c„+,,, ,�%a,,,%. •.,.s>3¢,1 ;`p '• Lt L'",+ �, Min.19/32- One or more Prelim. Elastobase, Elastobase P (poly- Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. in 4-inch lap and 12- SBS-SA, APP- W-68 inch plywood layers, any Attached film top) Dekfast #14 or Trufast 3' Metal Insulation inch o.c. in two, equally spaced, SBS-SA SA, SBS-TA or -52.5` combination Plate with Trufast HD staggered center rows APP-TA Min.19/32- One or more Prelim. Elastobase, Elastobase P (poly- Dekfast Hex (aka, Dekfast PLI'-H-2-7/8) with 12-inch o.c. in 4-inch lap and 12- W-69 inch plywood layers, any Attached film top) Dekfast #14 or Trufast3" Metal Insulation inch o.c. in two, equally spaced,' Polyflex SA Base APP-TA -52.5" combination Plate with Trufast HD staggered center rows Min. 19J32- One or more Prelim. Elastobase, Elastobase P (poly- OMG Fiat Bottom Plates (square) with 12-inch c.c. in 4-inch lap and 12- SBS-SA, APP- W-70 inch plywood layers, any Attached film top) Roofgrip #12 inch o,c, in two, equally spaced, SBS-SA SA, SBS-TA or -60.0` combination staggered center rows APP-TA Min. 19/32- One or more Prelim. Elastobase, Elastobase P (poly- OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12- W-71 inch plywood layers, any Attached film top) Roofgrip #12 inch o.c, in two, equally spaced, Polyflex SA Base APP-TA -60.01 combination I I I I staggered center rows Exterior Research and Design, I.I.C. d/b/a Trinity ) ERD Evaluation Report P9290.02.08-R20 for FL1654-R22 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polygiass Modified Bitumen Roof Systems, (570) 384-1230 Appendix 1, Page 15 of 58