HomeMy WebLinkAboutNOA - PLANTATION ROOF TILERECEIVED
NOV 2.7 2018
Permitting Depart ��1 ��
St. Lucie C66if1 / �, ®C�Q®MIAMI-DADE COUNTY
DADE MIAMI-V G Q'�P DUCT CONTROL SECTION
e Qj Q ti� 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCE r. Miami, Florida 33175-2474
BOARD iAND CODE ADMINISTRATION DIVISION GpJ � 0�`�� T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE(NOA) www.miamidade.eoy/economy
Boral iRoofing, LLCS!"�
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618 `t®Q`���®�` LE
SCOPE: �i�
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Bu' ,de
including the High Velocity Hurricane Zone of the Florida Building Code. gM "ED
BY
DESCRIPTION: Plantation Roof Tile
St Lucie County
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
i
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this I4OA shall be cause for termination and removal of NOA.
I
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
i
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #15-0721.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino
MIAMI•DADE COUNTY
�Fsl...• 4,31
i
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 1 of 7
JG ASSEMBLY APPROVAL
Roofing
;gory: Roofing Tiles
Concrete
1. SCOPE
This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined
by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS
127 usig the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based
system.
2. PRODUCT DESCRIPTION
Manufactured by Dimensions Test Product
Applicant Specifications Description
Plantation Tile Length: 16'h" TAS 112 Flat concrete roof tile for direct deck or
Width: 13" battened nail -on, mortar or adhesive set
applications.
Trim Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for
W = varies use at hips, rakes, ridges and valley
Varying thickness terminations. Manufactured for each tile
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee. FL
2.2 PRODUCTS MANUFACTURED BY OTHERS
Product Name Product Description
ICP Adh+ves Polyset® AH-160 Two component polyurethane
foam adhesive.
TILE BONDTM Roof Tile Adhesive Single component polyurethane
foam roof tile adhesive.
DAP Foam Touch N Seal Two component polyurethane
StormBorido 2 Roof Tile Adhesive foam adhesive.
Manufacturer
(With Current NOA)
ICP Adhesives and Sealants, Inc.
The Dow Chemical Company
Dap Foam, Inc.
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 2 of 7
2.3 SUBMITTED EVIDENCE:
Test Agency Test Identifier
kmerican Test Lab of South RT0624.05-14
Florida
Redland
The Cen
Redland
Redland
Redland
Redland
The Cen
Engine:
Walker l
Walker ]
for Applied
Inc.
for Applied
,, Inc.
sneering, Inc.
ineerinl?, Inc.
Walker Enaineerins, Inc.
Walker E}gineering, Inc.
FarabaugI Engineering and
Testing I4c.
Farabaugh Engineering and
Testing Inc.
Farabaugh Engineering and
Testing Inc.
PRI Construction Material
7161-03
Appendix III
94-060B
94-084
7161-03
Appendix II
Letter Dated Aug. 1, 1994
P0631-01
P0402
Project No. 307025
Test #MDC-76
Calculations
Calculations
Calculations
Calculations
T295-11
T306-11
T279-11
DAPF-004-02-08
DAPF-004-02-09
DAPF-004-02-10
Test Name/Report
TAS 112
Static Uplift Testing
PA 102 & PA 102(A)
Static Uplift Testing
PA 101 (Adhesive Set)
(Mortar Set)
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Tunnel Testing
PA 108 (Mortar Set)
Withdrawal Resistance Testing of
screw vs. smooth shank nails
Wind Driven Rain
PA 100
Aerodynamic Multiplier
25-7183
25-7094
25-7496
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
Two Patty Adhesive Set System
TAS-108
TAS-108
TAS-108
TAS 101
Static Uplift Resistance
Adhesive Set
Date
07/03/14
Dec. 1991
March, 1994
May 1994
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
Oct. 1994
March 1999
April 1999
March 1995
February 1996
April 1996
December 1996
April 1999
10/05/11
10/04/11
09/23/11
07/26/18
07/26/18
07/26/18
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
NOA No.: 18-0829.02
C
-DADE COUNTY , ..01, Expiration Date: 12/08/20
Approval Date: 10/11/18
j Page 3 of 7
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3i5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3 �7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
I Code and Rule 61 G20-3 of the Florida Administrative Code.
4. (INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
! Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
Length-1 (ft)
Width-w (ft)
Plantation Tile
11.6
1.375
1.08
! Table 2: Aerodynamic Multipliers - ,% (ft3)
Tile
Profile
X (ft3)
Batten Application
X (ft3)
Direct Deck Application
Plantation Tile
0.267
0.289
Table 3: Restoring Moments due to Gravity - M (ft.-Ibf)
Tile
Greater than
Profile)
21)• 12"
3": 12"
411• 12"
5": 12"
6": 12"
7": 12"
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Deck
Deck
Deck
Deck
Deck
Deck
Plantation
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Tile
z::
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Nail -On Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(Min 16/32"
(Min. 19/32"
plywood)
plywood)
Plantation
Tile
2-10d Ring Shank
30.9
38.1
17.2
Nails
1-10d Smooth or
7.3
9.8
4.9
Screw Shank Nail
2-10d Smooth or
14.0
18.8
7.4
Screw Shank Nails
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or
24.3
24.3
24.2
Screw Shank Nail
Field Clip)
1-10d Smooth or
19.0
19.0
22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or
35.5
35.5
34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or
31.9
31.9
32.2
j
Screw Shank Nails
Eave Clip)
2-10d Ring Shank
50.3
65.5
48.3
Nails'
1 Installation
with a 4" the
headlap and fasteners are located a minimum of 2%"from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Plantation Tile
1
Adhesive
2 See monufactures component approval for installation requirements.
3 The Dow Chemical Co. TILE BONDTM Roof Tile Adhesive weight per patty 13.9 grams. 31.3
4 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty 8 grams. 31.3
5 DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 5 of 7
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
For Single Patty Adhesive Set S stems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Plantati6n
Tile
Adhesives
6
See manufactures component approval for installation requirements.
7
ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset@ AH-160 Two -Component weight per patty 45 grams.
118.9
8
ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160 Two -Component weight per patty 24 grams
40.4
9
DAP Foam Touch N Seal Storm Bonde 2 Roof Tile Adhesive weight per paddy 45 grams.
73
10
DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 24 grams
48
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mortar Set Systems
Tile Profile Tile Application
Attachment
Resistance
See specific mortar manufacturer's Notice of Acceptance.
i
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
OR
7�7E-NTEIRRRI,',�7
BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE
6. BUILDING PERMIT REQumEmEws:
6.1 Application for building permit shall be accompanied by copies of the following:
1 6.1.1 This Notice of Acceptance.
�6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
MIAMI•DADE COUNTY
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 6 of 7
PROFILE DRAWING
BORAL PLANTATION FLAT CONCRETE TILE
END OF THIS ACCEPTANCE
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 7 of 7