Loading...
HomeMy WebLinkAboutNOA - PLANTATION ROOF TILERECEIVED NOV 2.7 2018 Permitting Depart ��1 �� St. Lucie C66if1 / �, ®C�Q®MIAMI-DADE COUNTY DADE MIAMI-V G Q'�P DUCT CONTROL SECTION e Qj Q ti� 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCE r. Miami, Florida 33175-2474 BOARD iAND CODE ADMINISTRATION DIVISION GpJ � 0�`�� T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE(NOA) www.miamidade.eoy/economy Boral iRoofing, LLCS!"� 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 `t®Q`���®�` LE SCOPE: �i� This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Bu' ,de including the High Velocity Hurricane Zone of the Florida Building Code. gM "ED BY DESCRIPTION: Plantation Roof Tile St Lucie County LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. i RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this I4OA shall be cause for termination and removal of NOA. I ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. i INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0721.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino MIAMI•DADE COUNTY �Fsl...• 4,31 i NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 1 of 7 JG ASSEMBLY APPROVAL Roofing ;gory: Roofing Tiles Concrete 1. SCOPE This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 usig the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Plantation Tile Length: 16'h" TAS 112 Flat concrete roof tile for direct deck or Width: 13" battened nail -on, mortar or adhesive set applications. Trim Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for W = varies use at hips, rakes, ridges and valley Varying thickness terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 1. Okeechobee. FL 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description ICP Adh+ves Polyset® AH-160 Two component polyurethane foam adhesive. TILE BONDTM Roof Tile Adhesive Single component polyurethane foam roof tile adhesive. DAP Foam Touch N Seal Two component polyurethane StormBorido 2 Roof Tile Adhesive foam adhesive. Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam, Inc. NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier kmerican Test Lab of South RT0624.05-14 Florida Redland The Cen Redland Redland Redland Redland The Cen Engine: Walker l Walker ] for Applied Inc. for Applied ,, Inc. sneering, Inc. ineerinl?, Inc. Walker Enaineerins, Inc. Walker E}gineering, Inc. FarabaugI Engineering and Testing I4c. Farabaugh Engineering and Testing Inc. Farabaugh Engineering and Testing Inc. PRI Construction Material 7161-03 Appendix III 94-060B 94-084 7161-03 Appendix II Letter Dated Aug. 1, 1994 P0631-01 P0402 Project No. 307025 Test #MDC-76 Calculations Calculations Calculations Calculations T295-11 T306-11 T279-11 DAPF-004-02-08 DAPF-004-02-09 DAPF-004-02-10 Test Name/Report TAS 112 Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Adhesive Set) (Mortar Set) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Aerodynamic Multiplier 25-7183 25-7094 25-7496 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 Two Patty Adhesive Set System TAS-108 TAS-108 TAS-108 TAS 101 Static Uplift Resistance Adhesive Set Date 07/03/14 Dec. 1991 March, 1994 May 1994 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 March 1999 April 1999 March 1995 February 1996 April 1996 December 1996 April 1999 10/05/11 10/04/11 09/23/11 07/26/18 07/26/18 07/26/18 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. NOA No.: 18-0829.02 C -DADE COUNTY , ..01, Expiration Date: 12/08/20 Approval Date: 10/11/18 j Page 3 of 7 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3i5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3 �7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building I Code and Rule 61 G20-3 of the Florida Administrative Code. 4. (INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application ! Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length-1 (ft) Width-w (ft) Plantation Tile 11.6 1.375 1.08 ! Table 2: Aerodynamic Multipliers - ,% (ft3) Tile Profile X (ft3) Batten Application X (ft3) Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M (ft.-Ibf) Tile Greater than Profile) 21)• 12" 3": 12" 411• 12" 5": 12" 6": 12" 7": 12" Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile z:: NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (Min 16/32" (Min. 19/32" plywood) plywood) Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 4.9 Screw Shank Nail 2-10d Smooth or 14.0 18.8 7.4 Screw Shank Nails 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or 24.3 24.3 24.2 Screw Shank Nail Field Clip) 1-10d Smooth or 19.0 19.0 22.1 Screw Shank Nail Eave Clip) 2-10d Smooth or 35.5 35.5 34.8 Screw Shank Nails Field Clip) 2-10d Smooth or 31.9 31.9 32.2 j Screw Shank Nails Eave Clip) 2-10d Ring Shank 50.3 65.5 48.3 Nails' 1 Installation with a 4" the headlap and fasteners are located a minimum of 2%"from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile 1 Adhesive 2 See monufactures component approval for installation requirements. 3 The Dow Chemical Co. TILE BONDTM Roof Tile Adhesive weight per patty 13.9 grams. 31.3 4 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty 8 grams. 31.3 5 DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45 NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 5 of 7 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) For Single Patty Adhesive Set S stems Tile Profile Tile Application Minimum Attachment Resistance Plantati6n Tile Adhesives 6 See manufactures component approval for installation requirements. 7 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset@ AH-160 Two -Component weight per patty 45 grams. 118.9 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160 Two -Component weight per patty 24 grams 40.4 9 DAP Foam Touch N Seal Storm Bonde 2 Roof Tile Adhesive weight per paddy 45 grams. 73 10 DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 24 grams 48 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance See specific mortar manufacturer's Notice of Acceptance. i 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". OR 7�7E-NTEIRRRI,',�7 BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE 6. BUILDING PERMIT REQumEmEws: 6.1 Application for building permit shall be accompanied by copies of the following: 1 6.1.1 This Notice of Acceptance. �6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 6 of 7 PROFILE DRAWING BORAL PLANTATION FLAT CONCRETE TILE END OF THIS ACCEPTANCE NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 7 of 7