HomeMy WebLinkAboutPRODUCT APPROVAL - SINGLE HUNG WINDOW011FAM7411W OF
c-s i ne
ss&Prefessional Regulation
BCIS Home I Log In User Registration Hot Topic Submit Surcharge Slats & Facts Publications FBC Staff BCIS Site Map f Links Search
Florida
uo
Product Approval
r USER: Public User
Product Approval Menu > Product or Application Search > Application Lis[ > Application Detail
II FL # FL10970-R7
SC
Application Type Affirmation
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
"Ne 000,
o Y
JELD-WEN
3737 Lakeport Blvd
Klamath Falls, OR 97601
(800) 535-3936
fbcl@jeld-wen.com
Jason Kantola
fbcl@jeld-wen.com
JELD-WEN Corporate Customer Service
3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800) 535-3936
customerserviceagents@jeld-wen.com
Windows
Single Hung
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 202
Year
1994
12 I affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity O Yes O No O N/A
Product Approval Method ptio
COD\/
lr �
Date Submitted 07/10/2017
Date Validated 07/10/2017
Date Pending FBC Approval
Date Approved 07/15/2017
Summary of Products
FL #
Model, Number or Name
Description
10970.1
Builders Atlantic Aluminum
Side Load Single Hung (4100) 52.125" x 72" Insulated Glass
(1/8 in - 1/8 out Annealed) or Single Glaze (3/16 in
Annealed)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL10970 R7 C CAC NI011624-RI.12df
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
•Impact Resistant: No
01/31/2026
Design Pressure: +50/-50
Installation Instructions
Other:,. ,
FL10970 R7 II DP-
50 52.125x72 Installation Instructions.odf
Verified By: Hermes F. Norero, P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL10970 R7 AE PER3032.Ddf
Created by Independent Third Party: Yes
Back Next
I
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone:'850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a=mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
Credit Card
Safe
411* MAX.
14 3 B' FROM
O.C. AX. CORNERS
12
5/B"
MAX.
N
W
S
z
3
— WINDOW WIDTH (52W MAX.)"
TYPICAL ELEVATION WITH FASTENERS
.•
v .•
�orsasrevr
1 1/4'
G .
MIN.
EMBEDMENT
1/4 MAX
SHIM
SPACE
1 1 IM
DOW CORNING
Lr 1199 SILICONE
GLAZING DETAIL
TYPICAL VERTICAL
FRAME SECTION
NOTEi Caulk between
unit and opening.
yu DOW CORNING
1199 SILICONE
•� .S
I
I
GLAZING DETAIL
n MAX
SHIM
SPACE
General Notes:
• The product shown herein. is designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
' d tad d t f th t t d d"
MASONRY
(NCTL 210-3656-1A)
1 1/4' MIN. EMBEDMENT—�—{ 3 HIM MAX
f SPACE.
EDGE Q 2 /
msT e yr • p .a
c
d
TYPICAL HORIZONTAL
FRAME SECTION
NOTE. Caulk between unit and opening.
Max Frame
DP
IMPACT
52 x 72°
+50/-50
NO
Installation Notes:
1. Seal flange / window to substrate.
2. Use 3/s' Tapcon fasteners through frame with sufficient length to
penetrate a minimum of 1 1/4' into the concrete (Min. t'c = 3000 psi)
In ustry s n ar requlremen s or e s a e con Itions. or masonry (Conforms to ASTM
• All glazing shall conform to ASTM E1300. 3. Host structure (wood buck, stud framing and opening) to be designed
• Minimum nominal glazing: 3/s' monolithic or 1 /8" insulated. and anchored to properly transfer all loads to the structure. The host
• Installation methods may be interchanged within the same opening. structure is the responsibility of the architect or engineer of record for
• An impact protective system is required where wind bome debris the project of installation.
Digitally signed by Hermes F. Norero, P.E.
protection is required by local building code. ` t ��� 4. Fasteners are not required through the sill. Reason: I am approving this document
• Maximum sizes are buck / net sizes and do not include f'rys;�s� g s��*., Date: 2013.10.2413:08:16 04'00'
This schedule addresses only the fasteners required to anchor the product to `�� ••••• •• �j PROIECrENGINEER: DATE: 3737 Lakeport Boulevard
achieve the rated design pressure and impact performance (where applicable) up �Q` .•• F - 02/24/2010 JELDrWN
to the size limitations noted. It is not intended as a guide to the installation Z ; • �.� .�0tTetzlaff
WN BY: SCALE: Klamath Falls, OR 97601
process and does not address the sealing consideration that may arise in different: ? 7 CRECKED NTS (541) 882 - 3451
BY: TITLE:
wall conditions. For the complete installation procedure, see the instructionE ' r -_
packaged with the window or go to wwwgeld-wen.com/resourcesriinstallaton. 'v T T APPROVED BY: Builder's Aluminum (4100) Single Hung
�O% P : <v� ` Masonry Installation (52.125" x 72.00")
This drawing and its contents are confidential and are not to be reproduced or X� ,tea TIPRo7ECrNo.:
copied in whole or in part or used or disclosed to others except as authorized by �e 1L01 B�NG3e ��
JELD-WEN, Inc. ��,��QQ� IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG. No.: REV: SHEET
FAPPJ# AN
AlM4narrnnrrunt#a957R MY44099 Venice Window Division BA4100_NCTL210.3656 A of 1 of 5
414" MAX.
FROM
CORNERS_
�_— WINDOW WIDTH (52J6" MAX.)"
TYPICAL ELEVATION WITH FASTENERS
HE
POM
• The product shown herein is designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300.
• Minimum nominal glazing: 3/6' monolithic or 1/8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind bome debris
protection is required by local building code.
• Maximum sizes are buck / net sizes and do not include fir���b� g ;-_
m¢ =U v4•
--
`1/4' MAX
SHIM
tISWACIE
DGV CORNING
L4'1199
SILICONE
GLAZING DETAIL
TYPICAL VERTICAL
FRAME SECTION
NOTEi Caulk between
unit and opening.
yam.
—
DOV CORNING
1199 SILICONE
/
I
mt GL e
GLAZING DETAIL
S MAX
Y SHIM
SPACE
WOOD FRAME
(NCTL 210-3656-1A)
1/4• MAX
IfSHIM
SPACE
1 1/2' MIN.
TYPICAL H❑RIZ❑NTAL
FRAME SECTION
NOTE, Caulk between unit and openinc
Max
Fram
e
DP
IMPACT
Installation Notes:
1. Seal flange /window to substrate.
2. Use #10 PFH or greater fasteners through frame with sufficient length
to penetrate a minimum of 1 1/2" into the wood framing (Min. S.G. _
0.55).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for
the project of installation.
4. Fasteners are not required in the sill.
This schedule addresses only the fasteners required to anchor the product to `�� • � • • • •. � �� PROJECT ENGn
achieve the rated design pressure and impact performance (where applicable) up �� .•' ,p to the size limitations noted. It is not intended as a guide to the installation Z ; • �� Tela
process and does not address the sealing consideration that may arise in different: 7 �:
wall conditions. For the complete installation procedure, see the instnlctionE 'fi' -_
packaged with the window or go to www.ield-wen.comlresources/installation. APPROVED BY:
DATE:
3737 Lakeport Boulevard
02/24/2010
�: Klamath Falls, OR 97601
NTS gL])
(541) 882 - 3451
TITLE:
Builder's Aluminum (4100) Single Hung
This drawing and its contents are confidential and are not to be reproduced or 1,10�` Fr�A�'••���PROJECT No.: Wood Frame Installation (52.125" x 72.00")
copied in whole -or in part or used or disclosed to others except as authorized by 1LD1
IDENTIFIER No. .PLANT NAME AND LocnTION: CAD DWG. No.: REV: SHEET
JELD-WEN, Inc.
MY44099 Venice Window Division BA4100_NCTL210.3656- A 01 2 of 5
44" MAX.
FROM
14.3/8" CORNERS
O.C. MAX.
t3"
O.C.
MAX.
N
n
c�
W
_
I_WINDOW WIDTH (52V MAX.)-�
TYPICAL ELEVATI❑N WITH FASTENERS
s
� 4
L SHINMAX
SPACE
I ►� "nc
DOV CORNING
v4% 11" SILICONE
GLAZING DETAIL
TYPICAL VERTICAL
FRAME SECTI❑N
NOTES Caulk between
unit and opening.
MV DGV CORNING
1199 SILICONE
/i—
/ a Umc
I
•
GLAZING DETAIL
i 1/4' MAX
SHIN
SPACE
2
nasr LV
5
General Notes:
• The product shown herein is designed, tested and manufactured -to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300.
• Minimum nominal glazing: 3/s' monolithic. or 1/8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind borne debris
protection is required by local building code. • Maximum sizes are buck / net sizes and do not include s�' f�r�s;�b�lggV.*i�
NAIL FIN
(NCTL 210-3656-1A)
1/4' MAX
SHIM
SPACE
TYPICAL H❑RIZ❑NTAL
FRAME SECTION
NOTE, Caulk between unit and opening
FraMe
BMax
DP
IMPACT
52 � x 72�
+50/-50
N❑
Installation Notes:
1. Seal nail fin to substrate.
2. Use #8 PH or greater fasteners through nail fin with sufficient length to
penetrate a minimum of 1Y2' into the wood framing (Min. S.G. = 0.55).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for the
project of installation.
4. We recommend using Tegratite'" installation
(http://www.jeld-wen.corn/newinstallationtechnologv/) for weatherproofing.
5. Window includes a slip on aluminum 6063-T5 nail fin (typ. wall thickness
.050"). Nail Fin extends approximately 1.258" away from frame.
This schedule addresses only the fasteners required to anchor the product to
achieve the rated design pressure and impact performance (where applicable) up
`�� •••,• •. ��
� �Q' .•• F
.�
PRo]ECrENGINEER:
--
DATE:
02/24/2010
3737 Lakeport Boulevard
P
JELJII�N
Tetzlaff
to the size- limitations noted. It is not intended as a guide to the installation
O
SCALE:NTS
Klamath Falls, OR 97601
(541) 882 - 3451
process and does not address the sealing consideration that may arise in different;
7 _
By.
TITLE:
wall conditions. For the complete installation procedure, see the instrllcfionE
packaged with the window or go to www.field-wen.comlresourcesfinstallation. �
-n T Y �
Builder's Aluminum (4100) Single Hung
AWRovEo sv:
Nail Fin Installation (52.125" x 72.00")
• This drawing and its contents are confidential and are not to be reproduced or
� X1,�ROAigq
1L01F5sIe
RT/PRO]ECiNo.:
ccpied in whole or in part or used or disclosed to others except as authorized by
10��y
IDENTIFIER No.
PLANT NAME AND LOCATION:
CAD DWG. No.:
REV:
SHEET
JELD-WEN, InC.
—��"" R,�, a 571
MY44099
Venice Window Division
BA4100_NCTL210-3656-
A 02
3 of 511
7
4J" MAX.
_ 14 3/8' FROMCORNERS
- O.C. MAX. - -- — —
r
MAX.
3
•
N
S
�O
3
�— WINDOW WIDTH (52V MAX.)"
TYPICAL ELEVATION WITH FASTENERS
General Notes:
read
+ STEEL
MIK STUD
Threw
�_1/4• MAX
SHIM
SPACE
/ r
1 v3M
DO W CORNING
yr D.G. SILICCNE
GLAZING DETAIL TYPICAL VERTICAL
FRAME SECTI❑N
NOTE, Caulk between
unit and opening.
W vM DOW CORNING
1199 SILICONE
ae=.m[
1
• GLAZING DETAIL
1/4' MAX
SMIM
SPACE
s0— I
• The product shown herein is'designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300. -
• Minimum nominal glazing: 3/s' monolithic or 1/8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind borne debris
protection is required by local building code.
• Maximum sizes are buck / net sizes and do not include fihs ego",
This schedule addresses only the fasteners required to anchor the product to �� •• ••
achieve the rated design pressure and impact performance (where applicable) up �� �Q' F
••
to the size limitations noted. It is not intended as a guide to the installation
process and does not address the sealing consideration that may arise in different; 7
wall conditions. For the complete installation procedure, see the insttuctionE �k .
packaged with the window or go to www.leld-wen.com/resourcesfiinstallafion. 0 T T
This drawing and its contents are confidential and are not to be reproduced or
copied in whole or in part or used or disclosed to others except as authorized by 'ir
JELD-WEN, Inc. FBPE
STEEL STUD NAIL FIN
(NCTL 210-3656-1A)
3 Thread MIN.
Through Stud
1e ga. MIN. —1/4' SHINo V 13
STEEL STUD SPACE MAX .r
Permitting De
St. Lucie C
TYPICAL HORIZ❑NTAL
FRAME SECTION
NOTEi Caulk between unit and opening.
Max Frame
DP
IMPACT
52 x 72�
+50/-50
N❑
1. Seal nail tin to substrate.
2. Use #10 sheet metal screw.or greater fasteners through the frame with
sufficient length to penetrate a minimum of three (3) threads beyond
metal substrate (Min. 18 Ga., Fy = 33 ksi).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for the
project of installation.
4. Fasteners are not required though the sill.
5. Window includes a slip on aluminum 6063-T5 nail fin (typ. wall thickness
.050"). Nail Fin extends approximately 1.258" away from frame.
DATE:
;1� BY.
1PPROVED BY: .
IDENTIFIER No.
5,q MY44099
3737 Lakeport Boulevard
02/25/2010 TELD-WN Klamath Falls, OR 97601
crei c.
Builder's Aluminum (4100) Single Hung
Steel Stud with Nail Fin Installation (52.125" x 72.00")
CAD DWG. No.: REV: SHEET
BAa100-NCTL210.365s- A 01 5 of