Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEi I. FORM R405-2017. , FLO�IDA 'E'NERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Street: .WYNNE THE GRAND CARLTO ^-� Builder Name: WYNNE BUILDING COPR. �p S�� S� N..�� Z� S D\� Permit Office: ST. LUCIE COUNTY 8Q/t,�,% ��77//�V City, State; Zip: FT. PIERCE , FL , Permit Number:�y Owner: i, WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Z e , ®IJf]tv Design Location: FL, Fort Pierce i County:: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior b. Frame Wood, Adjacent R=4.1 1250.00 ft2 1 • - R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 R 11. Duc s R ft2 7. Windowsi(.141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Sgl, U=0.54 101.25 ft2 SHGC SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGCI. SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Typles -sqft.) Insulation Area a. Electric Cap: 40 gallons (1445.5 EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat r Glass/Floor Area:: 0.098 Total Proposed Modified Loads: 48.03 PASS Total Baseline Loads: 48.08 I hereby certify that the plans and specifications covered by Review of the plans and iCfgE S7, this calculation are in compliance with the Florida Energy specifications covered by this�O Code. calculation indicates compliance ��'.,,'; ='.-'�VO with the Florida Energy Code. PREPARE B DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 r� o-� * Q I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. WE OWNER/A' BUILDING OFFICIAL: DATE: mR ` DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope lelakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/4/2018 11:29 AM FI L�� EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software NOV �/ Uhl Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2, Address Type: Street Address Building TIype: User:. Conditioned Area: 1446 Lot # Owner NIme: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 . • Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LOCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number'; Name Area Volume 1 I i Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 I BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 i ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ____ 0 1 0 JSIab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 61Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ---- 0 1 0 7ISlab-On.-Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ____ 0 1 0 I 4/4/2018 11429 AM I I EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 F6RM R405=2017 . FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 0 18.4 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No ATTIC V I# Type: Ventilation Vent Ratio (1 in) Area RBS IRCC 11 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood �4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING i 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE >SW Exterior Concrete Block- Ext Ins0EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SWI >NE Exterior Concrete Block - Ext InsiHEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsiBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW >NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 _ 5 NE LSW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE I>SW Exterior Concrete Block - Ext Ind3EDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=i>NW Exterior Concrete Block - Ext IndIEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S >N Exterior Concrete Block - Ext InREDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=i >NE Exterior Concrete Block - Ext In9EDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW F>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsLllAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 13 NEI SW Exterior Concrete Block - Ext InsaREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/4/2018 1.1 29 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 I FORM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 41 NE=>SW13 Metal 51 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE 1 # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 '•315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholeliouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM # System'Type Subtype Efficiency Capacity Block Ducts �1 Electric Heat Pump/ Split HSPF:8.5 34:8 kBtu/hr 1 sys#1 COOLING SYSTEM System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ .I Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation i Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/4/2018 1,129 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 176PM R4(h5-9D17 DUCTS -- Supply ---- �/ --- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ftz Attic 85 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coo' In Jan Heating f X Jan Feb HFeb Mar � Mar f A r Apr i Ma May [X] Jun X Jul ]Jun 4 Jul X Au f Auf X Se SeP f Oct Oct Nov Nov [ ] Dec [X] Dec Ventin [ Jan Feb X Mar [X] A r May E ] Jun [ Jul [ Aug [ Se [X Oct X Nov [ ] Dec ThermostatlSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 1 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/4/2018 11�.29 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 i 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA . TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Proiect Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design. Location: FL, Fort Pierce I ' COEIIIP®NENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,. skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) I, of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetration's Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. • Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity I spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting . Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing hand wiring. 'i Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wir*ng, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boot$' HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I I Caulking or other adhesive sealants shall not be used to fill voids between fire spronkler cover plates and walls or cgilings- a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/4/2018 11:29 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Y FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms' 5. Is this a worst case? 6. Conditioned floor area (ftZ) 7. Windows- Description a. U-Factor: Sgl, U=0.54 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 SHGC:' SHGC=0.25 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area We Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A , FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft 1 c. N/A R= ftZ 2 d. N/A R= ftZ 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 1446 b. N/A R= ftZ c. N/A R= ftZ Area 11. Ducts R ftZ 101.25 ftZ a. Sup: Attic, Ret: Attic, AH: Attic 6 325 40.00 ftZ 12. Cooling systems kBtu/hr Efficiency ftZ a. Central Unit 34.8 SEER:15.00 ftZ 3.832 ft. 0.250 Insulation Area R=0.0 1445.50 ftZ R= ftZ R= ftZ 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that�this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this homes before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of'New Home:U5C,,-p S ���� 5 � , City/FL Zip:S;�� 7;�>•,, ze kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 Pstat Olt ST,q�Fot� ws'� o *Note: 1 This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/4/2018 11:29 AM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1