HomeMy WebLinkAboutENERGY EFFICIENCY CODEi
I.
FORM R405-2017. ,
FLO�IDA 'E'NERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Street:
.WYNNE THE GRAND CARLTO ^-� Builder Name: WYNNE BUILDING COPR.
�p S�� S� N..�� Z� S D\� Permit Office: ST. LUCIE COUNTY
8Q/t,�,%
��77//�V
City, State;
Zip: FT. PIERCE , FL ,
Permit Number:�y
Owner:
i, WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Z e ,
®IJf]tv
Design Location:
FL, Fort Pierce
i
County:: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
b. Frame Wood, Adjacent
R=4.1 1250.00 ft2
1 •
-
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1446.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
R
11. Duc s
R ft2
7. Windowsi(.141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 101.25 ft2
SHGC SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGCI. SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Typles -sqft.) Insulation Area
a. Electric
Cap: 40 gallons
(1445.5
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
r
Glass/Floor Area:: 0.098 Total Proposed Modified Loads: 48.03
PASS
Total Baseline Loads: 48.08
I hereby certify that the plans and specifications covered by
Review of the plans and
iCfgE S7,
this calculation are in compliance with the Florida Energy
specifications covered by this�O
Code.
calculation indicates compliance
��'.,,'; ='.-'�VO
with the Florida Energy Code.
PREPARE B
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
r�
o-�
* Q
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
WE
OWNER/A'
BUILDING OFFICIAL:
DATE: mR `
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope lelakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/4/2018 11:29 AM
FI L��
EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software NOV �/ Uhl Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE GRAND CARL
Bedrooms: 2,
Address Type:
Street Address
Building TIype: User:.
Conditioned Area: 1446
Lot #
Owner NIme: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units: 1 . •
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LOCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY
Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number';
Name Area Volume
1
I
i Entire House 1446 11568
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
I
BEDROOM 301
2408 No
0
1
1 Yes
Yes
Yes
2
WIC 63
504 No
0
1 No
Yes
Yes
3
M.BATH 56
448 No
0
1 Yes
Yes
Yes
4
KITCHEN 192
1536 Yes
0
1 No
Yes
Yes
5
BATH 45
360 No
0
1 Yes
Yes
Yes
6
BEDROOM 2 204
1632 No
0
1
1 Yes
Yes
Yes
7
i ENTRY 55
440 No
0
1 Yes
Yes
Yes
8
LAUNDRY 42
336 No
0
1 Yes
Yes
Yes
9
GREAT/DINING 488
3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
----
0 1
0
Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
____
0 1
0
JSIab-On-Grade Edge Insulatio
BATH 5 ft 0
45 ft2
----
0 1
0
61Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7ISlab-On.-Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
____
0 1
0
I
4/4/2018 11429 AM
I
I
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
F6RM R405=2017 .
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Solar SA Emitt
Emitt
Deck
Pitch
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
0
18.4
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
ATTIC
V
I# Type: Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
11 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
�4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
i
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
1 NE >SW Exterior Concrete Block- Ext Ins0EDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SWI >NE Exterior Concrete Block - Ext InsiHEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsiBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW >NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
_ 5 NE LSW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE I>SW Exterior Concrete Block - Ext Ind3EDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=i>NW Exterior Concrete Block - Ext IndIEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S >N Exterior Concrete Block - Ext InREDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=i >NE Exterior Concrete Block - Ext In9EDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW F>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsLllAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
_ 13 NEI SW Exterior Concrete Block - Ext InsaREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINT
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
4/4/2018 1.1 29 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
I
FORM R405-2017
DOORS
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
41 NE=>SW13 Metal
51 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
1 # Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 '•315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholeliouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
HEATING SYSTEM
# System'Type
Subtype
Efficiency Capacity
Block
Ducts
�1 Electric Heat Pump/ Split
HSPF:8.5 34:8 kBtu/hr
1
sys#1
COOLING SYSTEM
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
.I
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType Location
EF Cap Use SetPnt
Conservation
i
Electric
None Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
ft2
4/4/2018 1,129 AM
EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 4 of 5
176PM R4(h5-9D17
DUCTS
-- Supply ----
�/
--- Return ---
Air
CFM 25
CFM25
HVAC #
# Location
R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
325 ftz
Attic
85 ftZ
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coo' In Jan
Heating f X Jan
Feb
HFeb
Mar
� Mar
f
A r
Apr i
Ma
May
[X] Jun X Jul
]Jun 4 Jul
X Au
f Auf
X Se
SeP
f
Oct
Oct
Nov
Nov
[ ] Dec
[X] Dec
Ventin [ Jan
Feb
X Mar
[X]
A r
May
E ] Jun [ Jul
[ Aug
[ Se
[X
Oct
X Nov
[ ] Dec
ThermostatlSchedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
1
PM
68
68
68
68
68 68
68
68
68
68
66
66
4/4/2018 11�.29 AM
EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 5
i
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
. TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Proiect Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design. Location: FL, Fort Pierce
I '
COEIIIP®NENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,. skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors) I,
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetration's
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
•
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
I
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting .
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing hand wiring. 'i
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wir*ng,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boot$'
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I I
Caulking or other adhesive sealants shall not be used to fill voids
between fire spronkler cover plates and walls or cgilings-
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/4/2018 11:29 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Y
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms'
5. Is this a worst case?
6. Conditioned floor area (ftZ)
7. Windows- Description
a. U-Factor: Sgl, U=0.54
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
SHGC:' SHGC=0.25
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area We Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0
192.00 ft
1
c. N/A
R=
ftZ
2
d. N/A
R=
ftZ
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ft2
1446
b. N/A
R=
ftZ
c. N/A
R=
ftZ
Area
11. Ducts
R ftZ
101.25 ftZ
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
40.00 ftZ
12. Cooling systems
kBtu/hr
Efficiency
ftZ
a. Central Unit
34.8 SEER:15.00
ftZ
3.832 ft.
0.250
Insulation
Area
R=0.0
1445.50 ftZ
R=
ftZ
R=
ftZ
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that�this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this homes before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of'New Home:U5C,,-p S ���� 5 � , City/FL Zip:S;�� 7;�>•,, ze
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
Olt ST,q�Fot�
ws'� o
*Note: 1 This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/4/2018 11:29 AM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1