HomeMy WebLinkAboutNOA - STEEL PANELUNTY SCANNED PRODUCT I CONTROL SEC IT ON DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BY 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION �� p ���e �LoOun Miami, Florida 33175-2474 @— T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w«'w.miamidaae.eov/economy Extreme Metal Fabricators, LLC CONCEALED FASTENERS OR ATTACHMENTS 216I Poma Drive ARE THE RESPONSIBILITY OF THE Palm City, FL 34990 CONTRACTOR OR RECORD SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: DMC 100 NS — 24GA Steel Panel over Plywood Deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in it's entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages I through 6. THESE PLANS AND ALL PROPOSED WORK The submitted documentation was reviewed by Gaspar J Rodriguez. ARE SUBJECT TO ANY CORRECTIONS -'6(Zl,t � 1 g 11— b� MIAMI•DADECOUNTY 6Te0 ' • M � • M ST. LUCIE COUNTY BUILDING DIVJk REVIEWED FOR COMPLIANCE REVIEWED DATE IT 4 PLANS ANMIT MUST BE KEPT SITE OR NO INSPECTIONS) WILL E REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO k 0MPLY WITf 1 ALL APPLICABLE CODES. NOA No.: 15-0309.09 [ON xpiration Date: 09/17/20 Approval Date: 09/17/15 Page I of 6 IJOB MADE ROOFING SYSTEM APPROVAL: Category: Roofing Sub;Catmorv: Metal, Panels (Non -Structural) Material: Steel Deck Type: Wood Maximum Desien Pressure -135 PSF TRADE NAMES. OF PRODUCTS MANUFACTURED OR LABELED, By APPLICANT: Test Product Product Dimensions Specifications . Description DMC 1.00 NS — 24GA Length: various TAS 11.0 Corrosion resistant, galvanized steel or galvalume Steel Panel Height: 1" standing seam metal panel with integral perforated Width: 16" fastening strip. Thickness: 24GA Min Yield Strength: 50 KSI Trim Pieces Length: varies N/A Corrosion resistant, galvanized steel or galvalume Width: varies standing seam metal panel with integral perforated Thickness: 24GA fastening strip. Min Yield Strength: 50 KSI Bostik.70-05A N/A TAS 110 Heavy duty construction adhesive. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI iConstructions Materials AKZC-003-02-01 ASTM B 117 05/13/08 Technologies, LLC AKZC-003-02-02 ASTM B 117 05/13/08 AKZC-003-02-63 ASTM G 26 05/13/08 AKZC-003-02-04 ASTM G 26 05/13/08 DMC-016-02-01 TAS 100 10/24/13 DMC-014-02-01 TAS 125 10/23/13 MIAMI•DADE COUNTY NOA No.: 15-0309.09 Expiration Date: 09/17/20 Approval Date: 09/17/15 Page 2 of 6 APPROVED ASSEMBLIES: System A: DMC 100 NS 24GA Steel Panel 16" wide Deck Type: Wood, Non -insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6" OC. In reroofing, where the deck is less than19/32" thick (Minimum ''/32") the above attachment method must be in addition to existing attachment. Underlayment: Minimum tmderl.ayment shall be an ASTM D 226 Type II installed with a minimiun 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 ''/4" annular ring -shank nails, spaced 6" OC at all laps and two staggered rows 12" OC in the field of the roll or any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in DMC Association of Regional Manufacturers Installation. Manual. Metal Panels and Install the "DMC 100 NS 24GA Steel Panel" including flashing penetrations, valleys, end Accessories: laps and accessories in compliance "DMC Association of Regional Manufacturers" current, published installation instructions and in compliance with the minilntun requirements detailed in Roofing Application Standard RAS 133. Field Conditions: Panels shall be secured along the male rib with corrosion resistant #10-13 x 1" PHW fasteners of sufficient length to penetrate through the sheathing a minimum of 3/16", and located at the maximum spacing listed in Table A below. See Detail B herein. The adjacent panel shall overlap and be secured to each other when the female rib of the panel is snapped over the male rib of panel. TABLE A MAximum DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Option 1 Perimeter and Corner' Option 2 Maximum Design Pressures -97.5 PSF -120 PSF -135 PSF Maximum Screw Spacing (1) fastener at 10 ''/z" OC (1) fastener at 5 '/" OC (2) fasteners at 5 '/4" OC Bostik Seam Sealant None None (2)3/ 16" beads 1. EXtrapolation shall not be allowed I NOA No.: 15-0309.09 CMIAMI-D�ADECOU=N Expiration Date: 09/17/20 Approval Date: 09/17/15 Page 3 of 6 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below: All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. IIAMI•DADE COUNTY 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 6. Panels may be jobsite roll formed with machine model #0290414; 3381213; 4260215; 5960197; 10811107, from DMC Association of Regional Manufacturers. NOA No.: 15-0309.09 CM1AM1MDADEC0=UN Expiration Date: 09/17/20 Approval Date: 09/17/15 Page 4 of 6 PROFILE DRAWINGS DETAIL A 0 DMC MONS - 24GA STEEL PANEL NOA No.: 15-0309.09 MIAMMADECOUNTY Expiration Date: 09/17/20 Approval Date: 09/17/15 Page 5 of 6 DETAIL B DMC , 1 DONS PANEL #10713x1"PHW (FIELD, PERIMETER, & CORNER CONDITION SEAM DETAIL WITHOUT BOSTIK SEAM. SEALANT II . DMC 100NS PANEL BOSTICK 70-05A (2 - 3116" BEADS) #10-13x1"PHN, (PERIMETER, & CORNER CONDITION SEAM DETAIL WITH BOSTIK SEAM SEALANT) END OF THIS ACCEPTANCE NOA No.: 15-0309.09 Q- M[AMMIDMEuNr�r Expiration Date: 09/17/20 Approval Date: 09/17/15 Page 6 of 6