Loading...
HomeMy WebLinkAboutMISC LETTER 2Correction for comments dated 12-6-18 'SQNN,p PLEASE FURNISH ON THE PLANS THE LOCATION OF THE EXISTING GARAGE, IN COMPLIANCE WITHCounty SECTION R302 OF THE FBC-R 2017 6TH EDITION. Existing detached garage to be demoed. Its outside the foot print of the proposed new storage building/garage. Its shown on the site plan. PLEASE SHOW ON THE SITE PLAN THE STORM WATER RUN OFF. SEE SECTION 107 OF THE 2017 FLORIDA (BUILDING CODE 6TH EDITION, AND SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. Revised site plan shows arrows to indicate direction of storm water run of as well as proposed dirt and,grass berm at north ans south property line. I PLEASE SHOW SLOPED FLOOR IN GARAGE IN ACCORDANCE WITH 309.1 OF THE 2017 FLORIDA RESIDENTIAL CODE Please see clouded area on sheet 1.1 -noted as rev. 1 PLEASE SHOW THE FLOOR AND LANDINGS AT THE EXTERIOR DOORS R311.3.1 OF THE FBC-R 2017 6TH EDITION Please see clouded area on sheet 1.1 noted as rev. 1 I - PLEASE SHOW THE REQUIRED ATTIC ACCESS R807.1 FBC-R 2017 6T" Pleas see clouded area on sheet 2.1 noted rev. 1 I i PLEASE SHOW DETAIL FOR THE DORMER EXTERIOR WALL SEE SECTION 107 OF THE FLORIDA BUILDING CODE ❑❑BUILDING, 6TH EDITION (2017) Please see section 1/3.2 clouded Typ. dormer section. Noted rev.1. The face of the dormer walls are masonry as detail provided shows. The side of the dormer walls that return back to roof section are built into the truss girders. Please see truss drawings and engineering provided. PLEASE SHOW TYPICAL WINDOW JAMB FOR THE FRAME WALL FLORIDA BUILDING CODE ❑❑BUILDING, 6TH EDITION (2017) i All window openings are going to be installed into proposed masonry walls and typ. detail is provided on sheet 4.2 detail 7 Please see typ. revision on sheet 2.1, 3.1, 3.2 showing the new propped dormer on the north elevation adjacent from the proposed south facing dormer. FILE COPY