HomeMy WebLinkAboutSOIL COMPACTION REPORT7- �'� F1- E TRIANGLE TESTING LAB, INC. CoA#3101 4750 ROYAL PALM BEACH BOULEVARD WEST PALM BEACH, FLORIDA 33411 (561)790,3049 e-mail: triangle2992(a gmail.com Date: January 24, 2019 To: Saint Lucie County Building Department Re: Soil Compaction Report -Density of In -Place Compacted Soil S&D CONTRACTING - DETACHED ADDITION 7003 S INDIAN RIVER DRIVE FORT PIERCE, FL CQPY.. ecervso JANZg?019 PQ t L , pa �UCo LI,7tj, ent SCANNED BY St Lucie County Test Date Test # Test Location Elevation In -Place Readings MMPD Values % Density Moisture Density. Moisture 0,1/23/19 1 Southeast Area 1'-2' 104.3 4.4 109.5 5.6 95.3 01/23/19 2 Center Area 0-1' 104.7 4.8 109.5 5.6 95.6 I O'1/23/19 3 Northwest Area 1'-2' 104.2 4.9 109.5 5.6 95.2 IKemarKs: All elevations are measured from top of pad grade. (Mod Proctor Test #1) Verification Statement statement shall serve as verification that the soil beneath the proposed structure has beers tested in accordance Section R401.4 of the 2017 Florida Building Code, Residential edition. The tests were conducted from the ing grade. Density tests were taken at a minimum of three (3) locations throughout the total depth of till. The depth of fill was apptoximately 2_0 feet. The foundation setbacks were based on information furnished by the client, at the time of testing. Based on the location and depths. tested, we verify that the fill has been compacted to a minimum of 95% of the maximum dry density as determined by ASTM D-1557 and that the minimum soil bearing value beneath the proposed foundation area is 2.500 pounds per sauare foot. .«eE submitted, chard Boyette, FL PE #42485 ce President nuary 24, 2019 I File # 20819