HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM iR405-2017 FI
• FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING O S UUXN
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE MAJESTIC
`�
Builder Name:
SCANNED
; THE MAJESTIC 4
��
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, O
Permit Number:
BY
Owner: WYNNE DEV.
Jurisdiction:
St Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2) �Y
I
1. New construction or existing New (From Plans)
9. Wall Types (1512.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1128.00 ftz
i
b. Frame - Wood, Exterior
R=11.0 384.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= f{z
4. Number of Bedrooms 2
d. N/A
R= ftZ
10. Ceiling Types (1608.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1608.00 ftz
6. Conditioned floor area above grade (ft2) 1608
b. N/A
R= ftZ
Conditioned floor area below grade (ftz) 0
c.
R= ftz
11. Ducts
R ftz
7. Windows(141.9 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 275
a. U-Factor: Sgl, U=0.54 101.94 ftz
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.254 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1608.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1608.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.088 Total Proposed Modified Loads: 50.22
PASS
Total Baseline Loads: 50.28
I hereby certify that the plans and specifications covered by
Review of the plans and
'TKE STgT
this calculation are in compliance with the Florida Energy
specifications covered by this
$ �y� __
Code.
calculation indicates compliance
with the Florida Energy Code.
1-4
PREPARED Y'
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
O y�
* - .
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
✓,� ��
COD
with the Florida Energy Code.
WE
OWNER/A
BUILDING OFFICIAL:
DATE: �``\
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certifiedl factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/27/201811:24 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5
VFORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
i
PROJECT
Title: WYNNE THE MAJESTIC Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1608
Lot #
Owner Name: WYNNE DEV.
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name:
Rotate Angle: 225
Street:
THE MAJESTIC
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area Volume
1 Entire House
1608 12864
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO
238 1904 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M.BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
589 4712 No
0
1
Yes
Yes
Yes
8 KITCHEN
228 1824 Yes
0
1
Yes
Yes
Yes
9 BATH 2
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
82 656 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 38 ft 0
238 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft2
----
0 1
0
B Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft 0
180 ft2
----
0 1
0
6/27/201811:24 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 5
i
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0
I
589 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio KITCHEN 12 ft 0
228 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio BATH 2 5 ft
0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio HALL 1 ft
0
25 ft2
----
0
1
0
11Slab-On-Grade Edge Insulatio FOYER 9 ft
0
82 ft2
----
0
1
0
ROOF
v
j
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
1 #
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Hip Metal 1695 ft2
0 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
I
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1608 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) MASTER BEDRO 30
Blown
238 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented) MASTER BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) M. BATH
30
Blown
61 ft2
0.1
Wood
5
Under Attic (Vented) LAUDRY
30
Blown
36 ft2
0.1
Wood
6
i
Under Attic (Vented) BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7
Under Attic (Vented) DINING/GREAT
30
Blown
589 ft2
0.1
Wood
8
Under Attic (Vented) KITCHEN
30
Blown
228 ft2
0.1
Wood
9
Under Attic (Vented) BATH 2
30
Blown
50 ft2
0.1
Wood
10
Under Attic (Vented) HALL
30
Blown
25 ft2
0.1
Wood
11
Under Attic (Vented) FOYER
30
Blown
82 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
-
Height
Sheathing Framing
-
Solar
Below
1 NE=>W
Exterior Concrete Block - Ext IngdASTER BE
4.1 17
0 8
0
136.0 ft2
0
0
0.5
0
2 ' S W=>E
Exterior Concrete Block - Ext InIMASTER BE
4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
3 NIW=>S
Exterior Concrete Block - Ext InsMASTER BE
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4 NE=>W
Exterior Concrete Block - Ext InEMASTER BA
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
5 NE=>W
Exterior Concrete Block - Ext InsuM. BATH
4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
6 NE=>W
Exterior Concrete Block - Ext InQEDROOM 2
4.1 12
0 8
0
96.0 ft2
0
0
0.5
0
7 SW=>E
Exterior Concrete Block - Ext InEWNING/GRE
4.1 30
0 8
0
240.0 ft2
0
0
0.5
0
8 NW=>S
Exterior Concrete Block - Ext InEINING/GRE
4.1 20
0 8
0
160.0 ft2
0
0
0.5
0
6/27/2018 1:24 PM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of 5
'FORM R4b5-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent CavR_Uaity Width
Height
Sheathing Framing Solar Below
#
S Pace
Ornt Wall Type
9
S,W=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 12 0 8
0 96.0 ft2
0
0 0.5
0
_ 10
NE=>W Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8
0 40.0 ft2
0
0 0.5
0
_ 11
SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8
0 64.0 ft2
0
0 0.5
0
12
I
S,W=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8
0 8.0 ft2
0
0 0.5
0
13
N=>SW Exterior Frame - Wood MASTER BE 11 26 8
208.0 ft2
0.23 0.5
0
14
E=>NW Exterior Frame - Wood MASTER BE 11 11 8
88.0 ft2
0.23 0.5
0
_ 15
W=>SE Exterior Frame - Wood MASTER BE 11 11 8
I
88.0 ft2
0.23 0.5
0
DOORS
# Ornt Door Type Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER None
.28 3
3
6 8
21.7 ft2
i WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V/
#, Ornt ID Frame Panes NFRC U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
11 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 N
32.9 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 N
6.9 ft2 1 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 N
16.4 ft2 1 ft 0 in
1 ft 4 in
None
None
4, SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N
20.6 ft2 1 ft 0 in
1 ft 4 in
None
None
51 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N
25.1 ft2 1 ft 0 in
1 ft 4 in
None
None
6' NW=>S 8 Metal Low-E Single Yes 0.55 0.25 N
40.0 ft2 9 ft 0 in
1 ft 4 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 1040 ft2 1040 ft2 48 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH
50
1 Wholehouse Proposed ACH(50) .000356 1500.8 82.39 154.95 .2578
7
HEATING SYSTEM
# System Type Subtype Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split HSPF:8.5
34.8 kBtu/hr
1
sys#1
6/27/2018 1:24 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
-Pr)Rnn RIMPI IT All IMMARY CHFCKI IRT REPORT
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
I
Split
SEER: 15 34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt Conservation
1 Electric
None
Garage
0.97
40 gal
60.9 gal
120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
iNone None
I
ft2
DUCTS
-- - Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
�/
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT QN RLF
Heat Cool
1 Attic
6 275 ft2
Attic
85 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan Feb
]Mar
X] Mar
Apr
APr
Ma
May
X Jun X Jul
f j Jun 4 Jul
Au1XI
ri Au
Se [ ]Oct Nov
Sep [ ]Oct Nov
H
[ ]Dec
[X] Dec
Ventin Jan Feb
[X Mar
[xl A r [
Ma
[ Jun [ Jul
Aug
Se [X]] Oct Nov
[ ]] Dec
Thermostat
Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8 9 10 11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78 80 80 80
80
PM
80
80 78
78
78 78
78
78 78 78 78
78
Cooling (WEH) AM
78
78 78
78
78 78
78
78 78 78 78
78
PM
78
78 78
78
78 78
78
78 78 78 78
78
Heating (WD) AM
66
66 66
66
66 68
68
68 68 68 68
68
PM
68
68 68
68
68 68
68
68 68 68 66
66
I
Heating (WEH) AM
66
66 66
66
66 68
68
68 68 68 68
68
PM
68
68 68
68
68 68
68
68 68 68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Def6ult(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/s .ft.
ft2
ft
0.3
FOYER
Name: Test Rater Signature: - q\1 oAll � � ''k
Rating Compant: Test Rater Date: LQ- DDA7)
I
6/27/2018 �1.24 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE MAJESTIC Builder Name:
Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: WYNNE DEV. Jurisdiction:
W
Desi�n Location: FL, Fort Pierce
I
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit; or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing! and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
on
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
___-:__-between
Caulking or other adhesive sealants shall not be used to fill voids
fire sprinkler cover plates and walls or ceilings.-.-
a. in auuuwn, inspection or tog roans shall be in accordance with the provisions of IGG-400.
6/27/2018 i :24 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
J '
2017+EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
I
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms
5. II this a worst case? (yes/no)
6. Conditioned floor area (sq. ft.)
7. Windows, type and area
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
c) Area
8. Skylights
a) U-factor:(weighted average)
Ib) Solar Heat Gain Coefficient (SHGC)
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
�C) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
';1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
IB. Adjacent:
�. Wood frame (Insulation R-value)
2I. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
4. 2 13. Cooling system:
Capacity 34.8
a) Split system
SEER 15.0
5. Yes b) Single package
SEER
c) Ground/water source
SEER/COP
6. 1608 d) Room unit/PTAC
EER
e) Other
7a. 0.543
7b.
0.250
14. Heating system: Capacity
34.8
7c.
141.9
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
c) Electric resistance COP
8a.
NA
d) Gas furnace, natural gas AFUE
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9a.
0.0
9b.
15. Water heating system
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
10A1.
11.0
e) Dedicated heat pump with tank EF
10A2.
4.1
f) Heat recovery unit HeatRec%
g) Other
10B1.
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
1la.
30.0
b) Cross ventilation
No
11 b.
c) Whole house fan
No
11 c.
d) Multizone cooling credit
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
r
Buil er Signature: Date:
Address of New Home: THE MAJESTIC )\1 City/FL Zip: FT. PIERCE, FL
I
6/27/2018 1:24:24 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1