Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGEPort St. Lucie FBPE CA # 4930 521 NW Enterprise Drive Port St. Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Soil Nuclear Gauge Client: Project: Report Date: 3/14/2016 IBIS Building Corp. 16-0545.00 Lp Test Method: ASTM D 6938 1315 West 53rd Street, Suite #3_ FerraTex West Palm Beach, FL 33407 4750 Magnum Drive Fort Pierce, FL 34981 �C.'), "Y� Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 1 3/8/16 P-1 N/A 11.0 116.0 10.9 113.2 98 95/105 Pass 2 3/8/16 P-1 N/A 11.0 116.0 10.7 112.2#112 2 97 95/105 Pass 3 3/8/16 P-1 N/A 11.0 116.0 9.9 113.412 98 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 1 Below Slab Grade: Ramp Slab, North End (PERMIT NO: 1512-0189) 0-1 Troxler T3430 34784 Thomas, Kenneth 2 Below Slab Grade: Ramp Slab, South End (PERMIT NO: 1512-0189) 0-1 Troxler T3430 34784 Thomas, Kenneth 3 Below Slab Grade: Ramp Slab, Center Area (PERMIT NO: 1512-0189) 0-1 Troxler T3430 34784 Thomas, Kenneth Remarks Comments Related Tests Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test # Related Test # Test Type ®S%j%I9111811"i 3/14/211V 6 �® Donald W1Vloler, P.E. rv' o LU ® ProfessiQ ngineer #%6.(9(75 TA e o State`of Florida ®°° Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1