Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFlorida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge FLA/COM 2004 v3.00 --.Form 40OB-2004 Method B: Envelope Trade -Off Compliance for Commercial Buildings Effective December 8, 2006 PROJECT SUMMARY Short Desc: TENANT IMPROVE. Owner: PETE HALL Addressl: MIDWAY INDUSTIRIAL PARK Address2: Description: D A P TENANT IMPI L o-r i City: FT. PIERCE State: FLORIDA Zip: 0 Type: Office Class: Renovation to existing Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Cond Area: 375 SF Coud & UnCond Area: 375 SF No of Storeys: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 1.5 If different, write in: 10/2007 EnergyGauge FLA/COM 2004 v3.00 EnergyGauge FLAXOM 2004 v3.00 INPUT DATA REPORT Proiect Information Project Name: TENANT IMPROVE. Orientation: North Project Title: D A P TENANT IMPROVE. BUILIDING LOT 1 Building Type: Office Address: MIDWAY INDUSTIRIAL PARK Building Classification: Renovation to existing building No.of Storeys: 1 State: FLORIDA Zip: 0 GrossArea: 375 SF Owner: PETE HALL Zones No Acronym Description Type Area Multiplier Total Area [sfJ [stl 1 OFFICE D A P TENANT CONDITIONED 375.0 1 375.0 ❑ IMPROVE. BUILIND LOT 1 7/10/2007 " ■ EnergyGauge FLA/COM 2004 v3.00 A , • � .x 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] [ft] plier [sf] [cf] In Zone: OFFICE 1 OFFICE D A P TENANT Office - Open Plan 15.00 25.00 8.00 1 375.0 3000.0 ❑ IMPROVE. BUILIND LOT-1 - - Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: OFFICE In Space: OFFICE 1 Recessed Fluorescent - General Lighting 5 64 320 Manual On/Off 4 ❑ No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.F/Btu] [Btu/sf.F] In Zone: OFFICE ❑ 1 NWALLS Construct 1032 15.00 8.00 1 120.0 North 0.0697 2.375 47.62 14.3 2 SWALL Construct 1032 15.00 8.00 1 120.0 North 0.0697 2.375 47.62 14.3 ❑ 3 EWALL Construct 1032 25.00 8.00 1 200.0 North 0.0697 2.375 47.62 14.3 ❑ 4 WWALL Construct 1031 25.00 8.00 1 200.0 North 0.1693 21.084 107.96 5.9 0 Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area - - - - -- - - --- -[Btu/hr-sf-F] - [ft]— ----[ft] plies [S fj 7/10/2007 EnergyGauge FLA/COM 2004 v3.00 In Zone: In Wall: El - Doors No Description Type Shaded? Width H (Effec) Multi [ft] [ft] plier Area [sf] Cond. Dens. Heat Cap. [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] R-Value [h.sf.FBtu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area [ft] [ft] plier [sf] Tilt [deg] Cond. , Heat Cap Dens. [Btu/hr. SE F] [Btu/sf. F] [lb/cf] R-Value [h.sf.FBtu] In Zone: OFFICE 1 ROOF Construct 1030 25.00 15.00 1 375.0 0.00 0.0419 6.16 29.57 23.9 ❑ Skylights No Description Type U SHGC Vis.Trans [Btu/hr sf F] W [ft] H (Effec) Multiplier Area [ft] [sf] Total Area [Sf] In Zone: In Roof. Floors No Description Type Width H (Effec) Multi Area IN [ft] plier [sf] Cond. Heat Cap. Dens. R-Value [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] jrn—Z&Ce--.— -OFFICE 7/10/2007 EnergyGauge FLA/COM 2004 v3.00 1 FLOOR 4 in. heavyweight 25.00 15.00 1 375.0 3.0030 9.32 140.00 0.33 ❑ concrete Systems AC-1 BARRRY'S DELICATESSEN Constant Volume Packaged System No. Of Units ,1 Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Heating System (Electric Furnace) 3 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 18000.00 6000.00 600.00 13.00 13.00 1.00 0.80 ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV Lj Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sVft/No] [W] 7/10/2007 EnergyGauge FLA/COM 2004 v3.00 4 No Type Piping Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] Materials Used Nomonal pipe Insulation Is Runout? Diameter Thickness [in] [in] J Mat No Acronym Description Only R-Value Used RValue [h.sf.FBtu] Thickness [ft] Conductivity [Btu/h.ft.F] Density [lb/cf] SpecificHeat [Btu/lb.F] 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 60 Mat160 Ceiling air space Yes 1.0000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 21 Matl21 4 in. Insulation Yes 13.3300 ❑ 9 Matl9 Air space resistance Yes 0.9100 ❑ 40 Mat140 4 in. Heavyweight concrete No 0.3330 0.3330 1.0000 140.00 0.2000 ❑ 7 Mat17 Finish No 0.1738 0.0417 0.2400 78.00 0.2600 ❑ 2 Mat12 1 in. Stucco No 0.2082 0.0833 0.4000 16.00 0.2000 ❑ 18 Mad18 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 ❑ 45 Mat145 8 in. Heavyweight concrete No 0.6670 0.6670 1.0000 140.00 0.2000 ❑ 10 Mat110 I in. Insulation No 3.3200 0.0830 0.0250 200 0.2000 ❑ 7/10/2007 EnergyGauge FLA/COM 2004 v3.00 s 5 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/21N Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1016 4 in. heavyweight concrete No No 3.00 9.32 140.00 0.3 ❑ Layer Material Material Thickness Framing No. IN Factor 1 40 4 in. Heavyweight concrete 0.3330 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1030 Construct 1030 No No 0.04 6.16 29.57 23.9 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 7 Finish 0.0417 0.000 ❑ 2 4 Steel siding 0.0050 0.000 ❑ 3 60 Ceiling air space 0.000 ❑ 4 18 2 in. Wood 0.1670 0.000 ❑ 5 23 6 in. Insulation 0.5000 0.000 ❑ 6 57 3/4 in. Plaster or gypsum 0.0625 0.000 ❑ 7 7 Finish 0.0417 0.000 ❑ 7/10/2007 EnergyGauge FLA/COM 2004 v3.00 6 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1031 Construct 1031 No No 0.17 '21.08 107.96 5.9 ❑ Layer Material Material Thickness Framing No. IN Factor 1 7 Finish 0.0417 0.000 ❑ 2 2 1 in. Stucco 0.0833 0.000 ❑ 3 45 8 in. Heavyweight concrete 0.6670 0.000 ❑ 4 9 Air space resistance 0.000 ❑ 5 10 1 in. Insulation 0.0830 0.000 ❑ 6 187 GYP ORPLAS BOARD,1/21N 0.0417 0.000 ❑ 7 7 Finish 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1032 Construct 1032 No No 0.07 2.37 47.62 14.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 7 Finish 0.0417 0.000 ❑ 2 2 1 in. Stucco 0.0833 0.000 ❑ 3 21 4 in. Insulation 0.3330 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 5 7 Finish 0.0417 0.000 ❑ 7/10/2007 EnergyGauge FLA/COM 2004 v3.00 7 Compliance Summary Component Design Criteria Result ENVELOPE 26.2 33.6 PASSES LIGHTING POWER 320.0 412.5 PASSES LIGHTING CONTROLS PASSES EXTERNAL LIGHTING None Entered HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS None Entered PIPING SYSTEMS None Entered Met all required compliance from Check List? Yes/No/NA RTANT NOTE: An input report of this design building must be submitted with this Compliance Report. 7h0/2007 i EnergyGauge FLA/COM 2004 v3.00 ON i _CERTIFICATIONS I hereby certify that the plans and' 'specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By:' Building Official: Date: juL _ Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code L Owner Agent: 0.4—e Date: -7 — i l o % If Required by Florida law, I hereby certify (*) that the, system design is in compliance with the FLorida Energy Efficiency Code Architect: PAUL WELCH INC. Reg No: 29945 Electrical Designer: PAUL WELCH INC. Reg No: 29945 Lighting Designer: PAUL WELCH INC. Reg No: 29945 Mechanical Designer: PAUL WELCH INC. Reg No: 29945 Plumbing Designer: PAUL WELCH INC. Reg No: 29945 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. Project: TENANT IMPROVE. Title: D A P TENANT IMPROVE. BUILIDING LOT 1 Type: Office (WEA File: DAYTONABEACH.TMY) Envelope Compliance Design Load Criteria Zone Heating Cooling Heating Cooling Building 16.20 10.00 20.50 13.10 Total Loads: Design =26.2 Criteria =33.6 PASSES /10/2007 EnergyGauge FLA/COM 2004 v3.00 External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (VV) (Sgft or ft) None roject: TENANT IMPROVE. itle: D A P TENANT IMPROVE. BUILIDING LOT 1 Spe: Office EA File: DAYTONABEACH.TMY) Lighting Power Compliance Space Ashrae Description Area Height No. of Design Effective Allowance ID (sq.ft) (ft) Spaces (W) (W) (W) I OFFICE 16 Office - Open Plan 375 8.0 1 320 320 413 �esign 320 (W) PASSES Effective: 320 (W) Allowance: 412.5 M )project: TENANT IMPROVE. Title: D A P TENANT IMPROVE. BUILIDING LOT 1 *ype: Office (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance OFFICE 16 Office - Open Plan 375 1 4 1 PASSES PASSES 7/j10/2007 I EnergyGauge FLA/COM 2004 v3.00 Project: TENANT IMPROVE. Title: D A P TENANT IMPROVE. BUILIDING LOT 1 Type: Office (W.EA File: DAYTONABEACH.TMY) ' AC-1 System Report Compliance Constant Volume Packaged No. of Units System 1 Component , Category Capacity Design Eff Eff Criteria Design IPLV Comp- IPLV Criteria liance Cooling System Ieating System ir Handling System -Supply Air Cooled < 65000 Btu/h 13.00 13.00 Cooling Capacity Electric Furnace 1.00 1.00 Air Handler (Supply) - 0.80 0.90 Constant Volume 13.00 PASSES PASSES PASSES , I PASSES Plant Compliance i Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Water Beater Compliance description Type Category Design Min Eff Eff Design Max Comp Loss Loss liance i None 7/10/2007 EnergyGauge FLA/COM 2004 v3.00 i Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] I I i I None et: TENANT IMPROVE. D A P TENANT IMPROVE. BUILIDING LOT 1 Office File: DAYTONABEACH.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R 19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? 7/� 0/2007 I EnergyGauge FLA/COM 2004 v3.00 6 PAUL WELCH INC. MECHANICAL * ELECTRICAL * CIVIL ENGINEERING 19B4 S.W. BILTMORE ST. SUITE#1 14 PORT SAINT LucIE, FL 349B4 PHONE (772) 7B5 - 9BBB FAX (772) 7B5-9933 I JUL V L 10 2007 SHEET OF DATE: MANUAL "N" HVAC WORK SHEET ROOM: D�CdG AREA: 6 �m JOB: ZONE: 1 e` N WALL .......................... S F X 3. 6 0 = ............... "0 WALL ........... SF X 7.36 = � �;. WALL ..................... ..... S F X yj WALL .................... SF x 6.56 = GLASS ........................ SF X 44 = • 0 SF X 49 — GLASS ........................ SF X 91 = i� GLASS ........................ SF X 91 I ( SF X 2.2 = ROOF...I,........................... ..... i 37,,0 W X 3.41 — X 500 = PEOPLE................................. INFILL ( 62- B9) .................... � �'L CFM X 34 = SUB TOTAL = 5 % DUCT LOSSES = TOTAL = O �01T I 1'�ao 44 S CFM