Loading...
HomeMy WebLinkAboutGENERAC - LIQUID COOLED GASEOUS ENGINE.3� .�1 GENERAC° PROTECTOR® QS SERIES PILE COPY Standby Generators Liquid -Cooled Gaseous Engine INCLUDES: Standby Power Rating Two -Line LCD Multilingual Digital SCANNED Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz Evolution" Controller (English/Spanis BY Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz -8t Lude COUh lodel RG032 (Aluminum - Bisque) - 32 kW 60 Hz French/Portuguese) with external viewing Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz window for easy indication of generator Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz status and breaker position. • True PowerTM Electrical Technology ^� Isochronous Electronic Governor ST.LUCIECOUNTY PLAN REVIEW •� Sound Attenuated Enclosure • Closed Coolant Recovery System BLDG: •I Smart Battery Charger DATFLEE. • UV/Ozone Resistant Hoses DATE:1-19�-% jP •� ±1 % Voltage Regulation PLUMB: •I Natural Gas or LP Operation DATE.__ 015 Year Limited Warranty MECN: • UL 2200 Listed DATE: • Capability to be installed within 18" 1 (457) mm of a building* *Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of i GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. ETV QUID •AuvntivlFEnIGu.Fp Aaiustc Wtvtlpi puh Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 32 & 38 kW not for sale in CA / MA O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. i O TEST CRITERIA: O GENERAC TRANSFER SWITCHES. Long life and reliability are PROTOTYPE TESTED v NEMA M131-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERAC' SENWTOA IOM&iTC VIEW AMTERICAST GENERATOR CONCRET '(ON 1--GRADE APP4CA 9 A M, 6 R I'CAST, 1: T., IXPOSSlRE 1 TT 1-01 c D M67 Pit 41 W-M-0 8IMIWWH 195 a •=Z g, L. i6� Mint a 0 GENERAC® 22 • 27 • 32 • 38 a 48 W application & engineering data GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kW Type Synchronous Rotor Insulation Class H (22 & 27 kW) orF (32. 38 & 48 kW) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ± 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) or Group 24F (48 kW), 525CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All niodels fully prototyped tested ENCLOSURE FEATURES Aluminum weather Ensures protection against mother nature. protective enclosure Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade Quiet, critical grade muffler is mounted inside the unit muffler to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514, ISO3O46, ISO8528, SAE J1349 and DIN6271) Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turbocharged/Altercooled (32 & 38 kW) Litter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Generac Model VType Cylinders 8 Displacement (Liters) 5.4 Bore (in/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge Crankcase Capacity (qUl) 4/3.8 (22, 27, 32 & 38 kW) or 6/5.7 (48 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven 1980 - 22 & 27 kW Fan Speed (rpm) 1500 - 32 & 38 kW 1954 - 48 kW Fan Diameter (in/mm) 18.1/459.7 (22 & 27 kW) or 22/558.8 (32, 38 & 48 kW) Fan Mode Pusher (22 & 27 kW) or Puller (32, 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG LP Fuel Pressure 11 -14" Water Column NG Fuel Pressure 5 -14" Water Column GENERAC 22 • 27 • 32 • 38 • 48 kW operating data GENERATOR OUTPUT VOLTAGEAW - 60 Hz kW LPG Amo LPG kW Nat. Gas Amo Nat. Gas CB Size (Both) 120/240 V, 10,1.0 pf 22 92 22 92 100 R0022 1201208 V, 30, 0.8 pf 22 76 22 76 80 120/240 V, 30, 0.8 pf 22 66 22 66 80 120/240 V, 10, 1.0 pf 27 113 25 104 125 RG027 120/208 V, 30, 0.8 pf 27 94 25 87 100 120/240 V. 30, 0.8 pf 27 81 25 75 90 120/240 V, 10, 1.0 pf 32 133 32 133 150 120/208 V, 30, 0.8 pf 32 111 32 111 125 R6032 120/240 V, 30. 0.8 pf 32 96 32 96 100 277/480 V, 30, 0.8 pf 32 48 32 48 60 120/240 V, 10.1.0 pf 38 158 38 158 175 120/208 V, 30, 0.8 pf 38 132 38 132 150 RG038 120/240 V. 30, 0.8 pf 38 114 38 114 125 277/480 V, 30, 0.8 pf 38 57 38 57 60 120/240 V, 10, 1.0 pf 48 200 48 200 200 RG048 120/208 V, 30, 0.8 pf 48 167 48 167 175 120/240 V, 30, 0.8 pf 48 144 48 144 150 277/480 V, 30, 0.8 pf 1 48 72 1 48 1 72 1 80 I SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @ < .4 pf Natural Gas Propane 15% 30% (ft3/hr) (m3/hr) (pal/hr) Who (113/hr) 120/240 V, 10 55 135 RG022 120/208 V, 30 40 92 120/240 V, 30 35 80 RG027 120/240 V, 10 62 170 120/208 V, 30 70 120 120/240 V, 30 61 103 RG032 120/240 V, 10 75 180 120/208 V, 30 87 210 120/240 V, 30 75 182 277/480 V, 30 36 87 120/240 V, 10 75 180 RGO38 120/208 V, 30 87 210 120/240 V, 30 75 182 277/480 V. 30 36 87 RG048 120/240 V, 10 85 195 120/208 V, 30 90 218 120/240 V, 30 78 189 277/480 V, 30 36 87 I I Note: Fuel pipe must be sized for full load. For Btu, content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. Exercise cycle 42 1 1.2 0.44 1.7 16 RG022 25% of rated load 100 2.8 1.1 4.2 40 50% of rated load 190 5.4 2.1 7.8 75 75% of rated load 255 7.2 2.8 10.5 101 100% of rated load 316 9 1 3.4 13 1 125 RG027 Exercise cycle 42 1.2 0.44 1.7 16 25% of rated load 108 3.1 1.2 4.5 43 50% of rated load 197 5.6 2.1 8.1 78 75% of rated load 287 8.2 3.1 11.8 114 100% of rated load 359 10.2 3.9 14.o 143 RG032 Exercise cycle 79 2.2 0.8 3.2 30 25% of rated load 144 4.1 1.7 6.3 60 50% of rated load 226 6.4 2.7 10.3 97 75% of rated load 298 6.4 3.7 13.9 132 100% of rated load 375 10.6 4.6 17.5 166 Exercise cycle 83 2.3 0.9 3.2 31 RG038 25% of rated load 162 4.6 1.7 6.6 62 50% of rated load 255 7.2 2.9 10.8 1 103 75% of rated load 345 9.8 4 15 142 100% of rated load 437 12.4 5.2 19 185 Exercise cycle 95 2.7 1 3.9 38 25% of rated load 204 5.8 2.16 B.5 82 RG048 50% of rated load 392 11.1 4.14 15.7 1 151 75% of rated load 1 547 15.5 5.8 22.8 220 100% of rated load 1 756 1 21.5 1 7.96 31.3 302 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. GENERAL" 22 • 27 • 32 • 38 a 48 kW operating data ENGINE COOLING I 22 kW 27 kW 32 & 38 kW 48 kW Airiflow (inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2 System coolant capacity (gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 3/11.4 Heat rejection to coolant (BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 186,000/196.2 Maximum operation air temperature on radiator (`C/°F) 60/150 Maximum ambient temperature (°C/°F) 50/140 REQUIREMENTS Flow at rated power (cfm/cmm) 1 68/1.9 1 68/1.9 1 106/3 1 163/4.6 1 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 1 61 1 61 1 58 1 63 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load" 1 70 1 70 1 64 1 68 'Sound levels are taken from the front of the venerator. Sound levels taken from other sides of the venerator may he higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) 165/4.7 180/5.1 1 300/8.5 414/11.7 Exhaust temperature at muffler outlet ('C/°F) 482/900 538/1000 1 579/1075 552/1025 I ENGINE PARAMETERS Rated Synchronous rpm 1800 1 POKIER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration...................................................................•..................•....................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (22, 27 & 48 kW)..............................................•......................................1 % for every 100 m above 183 m or 3% for every 1000 It above 600 It Altitude Deration (32 & 38 kW).......................................................................................1 % for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES Two -Line Plain Text LCD Display ............. ....................................................................................................................... Simple user interface for ease of operation. Mode; Switch: Auto..............................................................................................................................•...............Automatic Start on Utility failure. 7 day exerciser Off...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual.......................•................................................................. Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds.................................................................................................................................................10 sec standard Engine Start Sequence..................................................................................................................... Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration) EngineWarm-up.....................................................................:...............................................................................................................................................5 sec EngineCool-Down.......................................•...............................•...............................................•.........................................•..•.............................................1 min Starter Lock-out................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartlBatteryCharger ........................................................................................................................................................................................................ Standard Automatic Voltage Regulation with Over and Under Voltage Protection...............................................................................:................................................ Standard AutomaticLow Oil Pressure Shutdown..•...................................................................................................•...............•........................................................Standard OverspeedShutdown.........................•............................•.......................................................................................................................................Standard, 72 Hz HighTemperature Shutdown............................................•..•...............................................................................................................................................Standard OvercrankProtection.......................................................................................•......................................................................•...........................................Standard SafetylFused................................................................................................•...............................................•.........................•........................................... Standard Failureto Transfer Protection.....................................................................................•.....................•.........................................•...................................•..•. Standard LowBattery Protection.....................................•............................................................•............................•...............•........................................................Standard 50 Event Run Log ........... ............. ........... ..................... ......... ................ .............................. .....................................•............ ................................•........... Standard FuturelSetCapable Exerciser .................................................... ...................................................................................................................................:.•....Standard IncorrectWiring Protection.................................................•...............................................................................................................................................Standard InternalFault Protection..................................................................................................................................................................................................... Standard CommonExternal Fault Capability..........................................................................................•.....•............•..................•.....................................................Standard GovernorFailure Protection....................................................................................•...........................................................................................................Standard 22.27.32.38.48kW GENERAL` available accessories e v. i{i k'.e`:�r, b ... � ,./... ... ,�....,�«.."..:,.: ,,,,,: .�'.,�,,,, . Ck/�: .p...�'.✓�...,,.......�'ri$'w':r'.va iLr#''..f'y '' Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with G606463-4 Mobile Link'"' any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. G006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid -cooled units compatible with Mobile Link". GO05630-1- 22, 27, 32 & 38 kW If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit Cold Weather Kit to maintain optimal battery temperature. Kit consists of battery warmer with GOO5632-1- 48 kW I thermostat built into the wrap. GO05616-0 - 22, 27, 32 & 38 kW Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for G007088-0 - 48 kW Weather Kit extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to G005703-0 - Bisque Paint Kit touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G005656-0 - 22 & 27 kW Scheduled The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware G005984-0 - 32 & 38 kW Maintenance Kit necessary to perform complete maintenance on Generac liquid -cooled G006205-0 -__48 kW generators. G006664-0 Local Wireless Completely wireless and battery powered, Generac's wireless remote monitor Monitor provides you with instant status information without ever leaving the house. G066665-0 Wireless Remote Recommended for use with the Wireless Remote on units up to 60 kW, Extension Harness required for use on units 70 kW or greater. Smart Management Modules are used in conjunction with the Automatic G006873-0 Smart Management Transfer Switch to increase its power management capabilities. It provides Module (50 Amps) additional power management flexibility not found in any other power management system. 0006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the Wi-Fi LP Fuel Level connected LP fuel tank. Monitoring the LP tank's fuel level is an important G007005-0 Monitor step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. RADIATOR/EXHAUST DISCHARGEAIR AIR INTAKE (BOTH SIDES) (BOTH SIDES) BATTERY 12 [''[ GRP 26 I I NEGATIVE GROUND .JVL PIN: 077483 REMOVECOVE FOR ACCESS TO { s, RADIATOR FILL CAP'f_; 427 [16.81 EXHAUST MUFFLER - ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR 1411 `.— 629.9 [24.8] [5.6] CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW 48 - [1.9] 1040 ►{ [40.91 FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW SERVICE ITEM 24L OILRLLCAP EITHER SIDE OIL DIP STICK RIGHTSIDE OIL FO.TER I RIGHTSIDE AIR CLEANER ELEMENT LEFT SIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHERSIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. SEE NOTE 3 0 CD c 00 00 rn -N it NOTES: c-) 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1885 (74.2") LONG, CD REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE v AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. -LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 518-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. :�-REAR ENCLOSURE 980 COVER PANEL [38.6] SEE NOTE 4 OVERALL HEIGHT 7 USTOMERACCESS 48 - ASSEMBLY,CONTROL [19] PANELACCESS, ACCESS, n.p jIL BATTERY CHARGER LOCATED WITHIN - SEE NOTE 4 776 [30.6]�1 45 OVERALL WIDTH 11.81 REAR VIEW TYP WEIGHT DATA ENGINE/KW ENCLOSURE WEIGHT GENV SHWEIGHT IPPING SKID SHIPP[NGWEIGHT KVA MATERIAL KGG [LBSI RBS] KG RBS] KG (LBSI 24L 221CW (60HZ) SINGLE PHASE ITAKVA(50HZ) AL 4105[905] 30[661 "019711 THREE PHASE 22KVA (50HZ) 2AL 27KW (60HZ) SINGLE PHASE 21.6KVA(50HZ) AL 426 W01 30[66] 456[10061 THREE PHASE 27KVA(501-Z) 631 [24.81 DOOR TYP 1490 158.71 TYP ►{ — 1580 [62.2] OVERALL LENGTH RIGHT SIDE VIEW DIMENSIONS: MM [INCH] VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR s• y m z CD m � 33 A) Q rF 45 [1.8] TOP VIEW LEFT SIDE VIEW 27 DIMENSIONS: MM [INCH] IOTE -STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. IRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. 5] STUB -UP COVER 735 [28.9] 96 [3.8] 723 [28.5] TYP MOUNTING SLOT CENTERS 776 [30.6] REAR VIEW N v f � y d m O 0 0� m N 33 n N �C � 0 170i�4U I�phase 1Sttpf Amp (L,PG} 92 1 t - The best liquid cooled engine packs more power into a smaller footprint - ideal when space is a premium. The neutral styling, color and small footprint fits unobtrusively into landscaping. QUIET-TESTT' All standby generators run a weekly test to ensure the system is running properly. Thanks to Quiet -Test, your Protector Series business standby generator runs its self -test at a lower, quieter RPM than standard operation, and can be programmed to run weekly, bi-weekly, or monthly. MOBILE LINK" REMOTE MONITORING Mobile Link is the cellular remote monitoring system from Generac that lets you check on your generator's status even when you are away. Optimal for Business owners.- Clean burning, continuous fuel choice of natural gas to LP. DURABLE STEEL ENCLOSURE Sturdy galvanneal steel enclosure with a durable powder -coat finish for superior weather protection. Aluminum Enclosure NOW Available: Aluminum enclosures provide enhanced durability and corrosion resistance in multiple areas including coastal and salt -ware environments. 104 113 125 133 150 158 188 200 250 i 9vi1/9083 phasn OSpJ Amp"(LPG)"- 76 87 94. 104 111 125 132 156 167 208 -�... 12072403 p66 75 180 t il{8o3 pifaee �1 tt (ff Amp (IPG a8 5� - 57 6a 72 90 h'1(r 92 104 104 125 133 150 156 188 200 250 # i7i 13 tr}i35s p : n#I ( a : }a t : 76 87 87104 ill 125 132 156 167 208 R7 dR fF €i T5 75 90 96 108 114 135 144 180T10 1} Y .............................. N/A ... .... _.................. _ ............................... N/A -- ..._ N/A ... ... -_.._................................................ N/A ............................................................................................................... 48 54 57 ... _..- 68 _... ........ -----............ 72 _.... ............ - - 90 i2 Rafod Synchron(Us RPM 6O;Hta'_ $+ 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 � '4s MCyilrtd rs �' 4 4 4 4 4 4 4 4 8 4 100%-of Rated Load- NO", ,.< 16 _..... ................................ 430 -.__....................... _.................. 359 _........_...........................--.............................._._._.........._...-- 492 :375 730 437 730 75(i 862 £ (t0 n 4f P3"ted Lead f�F p ne ftx/ 166 290 185 290 302 327 126_._............ 143 197 �i1n-rAeiUrsl23eet(OAj ... --172 58 61 58 61 63 65 61 59 61 59 M1tbYdrtil Ioad,t 7 meteixl8 fei(DA) 0 72 70 73 64 73 65 73 68 72 St4et Wetithl r Protective n les ars k ith Ai 1 m r minuet R g , fv U , Vef, (3 SQUd},r,,: Altikmnyln Nle�ther r'xatect#tve EnclosuprVo� m m m v.,- ` ' a 4 t q#coons#ens ft,xWxf� in inolt9s} be.2 x `SO.ii 82.2 x ;i6.(i 1i2.2 x 30,(i G2.2 x 30.G 76.8 x 35 76.8 x 35 46.'1 76.8 x 35 46.1 76.8 x 35 46.1 76.8 x 35 46.1 76.8 x 35 = x 38.6 —. x 38.6 x 38.6 ------- x 3i1.6 -----...._...._._.._.-.._ x 46.1 x ....... x _.._.._...._....-........_ x ..._........--------.-- x x 46.1 1 - ,WeightW/%JedI En&IosUre (LkjSs} ,; N/A 865 NIA 895 N/A 1255 N/A 1313 N/A 1283 W611' tNllAlUml(tumEnciosule'(Ltts _` 900 777 940 '1225 1202 1235 1260 1555 1230 _� •,.- .. �- 807 g ° ti+larCatlty (inctudfng 5 Year Limited' ----- " Extended warenties available through an authorized dealer. Nationwide Dealer Service Network i Generac's'commitment to service includes scheduled maintenance programs, warranty assistance and emergency service to ensure that Generac customers are never left powerless. The largest nationwide dealer network has factory trained technicians on staff and maintains large inventories of Generac parts, components and accessories. Find a dealer near you at generac.com. OL2985 Rev.A 03-2015 02015 Generac Power Systems, Inc. All rights reserved. Specifications are subject to change without notice. GENERACm Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 generac.com 1-888-GENERAC (1-888-436-3722)