HomeMy WebLinkAboutEVALUATION REPORT - METAL ROOFINGI 37� i EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION r. • FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.3-R3 ROOFING METAL ROOFING CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4200 SCANNED BY St Lucie County THESE PLANS AND ALI- PROPOSED WORK ARE SUBJECT TO ANY CORRECrt10NS REQUIRED BY FIELD INSPECTORS THAT P Y� MAY BE NECE.,SSA,R? 1N Oti qE- TO Prepared B COl��dPLY ��liTia A;-� fP 1-�A CEDES. Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) o®+c�ats�e�soso Installation Details (1 Page) `��%`° S0CKAt/ti ,i,-� cS�2uC,-Tu �— ST. LUCIE COUNTY BUILDING DIV ON REVIEWED FOR CO PLIANCE REVI 1•C DATE I PLANS AN PERMIT MUST BE KEPT JOB SITE OR NO INSPECTION(S) WILL MADE Report No. C2182-3 Date�..17 o P . �' G E N SF•. 9,L� oro N No 62240 ,. � o : arc -0: :441ti oP .. STATE OF •4jj ice, S O Aj�`Ga,'+° Manufacturer: Product Name: Panel Description: Materials: as FL 14645.3-R3 C2182-3 9.9.17 Page 2 of 3 Metal Sales Manufacturing Corporation 5V-Crimp 24" wide coverage with (5) 1/2" high ribs Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 1/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: i Design Uplift Pressure: (Factor of Safety = 2) Fastener Pattern: Type: I At panel ends I At intermediate I Test Standards: !Code Compliance: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. 41.6 psf @ fastener spacing of 36" o.c. 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @ fastener spacing of 8" o.c. #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". @ 6" o.c. across panel width @ 12" o.c. across panel width Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. lProduct Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity FL 14645.3-R3 C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/1/09 I NEW UNDERLAYMENT FASTENER AT PANEL FLAT 5V-CRIMP =5 SEE DETAIL 2 SEE DETAIL 1 (REQUIRED ONLY FOR REQUIRED FOR PANEL 3 -,,,,,,-SEE � (PANEL OVERLAP) NEW CONSTRUCTION) ENDS ONLY. /J Lz EXISTING UNDERLAYMENT / PL ANEL FASTENER PER ALLOWABLE (OPTIONAL) MINIMUM ATTACHMENT: PRESSURE TABLE ON THIS SHEET. 8d x 2.5' LONG RING SHANK NAIL OR #8 x 2° LONG WOOD SCREWS SPACED ® 6' O.C. IN THE FIELD & MIN. 2X_ WOOD RAFTER/JOIST/ 4' O.C. AT PLYWOOD EDGES g TRUSS AT MAX. 24' O.C. a TYPICAL PANEL INSTALLATION X—SECTION g Z �o "P8 /— #9-16 OR #10-14 WOODSCREWS ALLOWABLE UPLIFT PRESSURE G'�p WITH SFI F SFAI ING WASHFR AT IRONLYENT FOR MAXIMUM SPACING OF 36' O.C. FASTENER PRESSURE ?TRUCTION) SPACING (PSF) 5V-CRIMP CLES MIN 26 GA. 36 41.6 16 74.8 8 196.75 Jm » . �B W T EXISTING U (OPTIONAL) I NEW UNDERLAYMENT (REOUI(ED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) `PLYWOOD D ETAI L 1 19/32' THICK (MIN.) #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP F MIN 26 GA. EXISTING UNDERLAYMENT J V PLYWOOD (OPTIONAL) 19/32' THICK (MIN.) I DETAIL 2 w a o a ME GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE u =$ FLORIDA BUILDING CODE (FDIC). 2. ROOF PANELS SHALL BE MIN. 26 GA It = 0.0169"). EFFECTIVE COVERING 1 YN z WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS"N - �d SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS - o g PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE. THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.