HomeMy WebLinkAboutPROJECT SUMMARY7225 S
1 �
Project Summary
Entire House
One Stop Cooling and Heating
Coirt Winter Park. FL 32792 Plane: (4071629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopGooling.com License: CAC032444
Job: Lot 064 F1833 B RHG Den...
Date: 06/07/2017
By. XF/MC
For: Ryan Homes
L tSCMNED
BY .
Notes: 31.;.ude County
Desiqn Information
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db 42 OF
Inside db 68 OF
Design TD 26 OF
Heating Summary
Structure 17275 Btuh
Ducts 1765 Btuh
Central vent (0 cfm) 0 Btuh
(none)
umidification
Piping
Equipment load
Infiltration
Method
Construction quality
Fireplaces
0 Btuh
19039 BBtuh
i
Heating
Area (ft2)
1853
Volume (ft3)
16123
Air changes/hour
0.38
Equiv. AVF (cfm)
102
Summer Design Conditions
Outside db
90
OF
Inside db
72
OF
Design TD
18
OF
Daily range
M
Relative humidity
50
%
Moisture difference
68
gr/Ib
Sensible Cooling Equipment Load Sizing
Structure
16190
Btuh
Ducts
3491
Btuh
Central vent (O cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swin multiplier
0.95
Equipmen� sensible load
18697
Btuh
Simplified
Latent Cooling Equipment Load Sizing
Average
0
Structure
3279
Btuh
Ducts
897
Btuh
Central vent (0 cfm)
0
Btuh
Cooling
(none)
1853
Equipment latent load
4176
Btuh
16123
0.20
Equipment Total Load (Sen+Lat)
22873
Btuh
54
Req. total capacity at 0.75 SHR
2.1
ton
Heating Equipment Summary
Make Goodman Mfgg.
Trade GOODMAN; JANITROL; AMANA DISTI..
Model GSZ140301 K
AHRI ref 7995113
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Airflow factor
Static pressure
Space thermostat
Capacity balance point = 33 OF
Calculations
8.2 HSPF
27800 Btuh @ 470F
0
0
U cfm
0 cfm/Btuh
0.50 in H2O
Cooling Equipment Summary
Make Goodman Mfqq.
Trade GOODMAN; JANITROL;
AMANA DISTI...
Cond GSZ140301 K
Coil . ARUF31 B14A
_
AHRI ref 7995113
Efficiency 12.0 EER,14 SEER
Sensible cooling
21000 Btuh
Latent cooling
7000 Btuh
Total cooling
28000 Btuh
Actual air flow
933 cfm
Air flow factor
OA47 cfm/Btuh
Static pressure
0.50 in H2O
Load sensible heat ratio
0.82
Boldldalic values have been manually overridden
3d byACCAto meet all requirements of Manual J 8th Ed.
-*- =1012tsoft-
Right.Sdte®Universal 201818.0.31 RSW6877
ktop\TEMP PRINIV_ot 064 F1833 B RHG Den- N.rLp Calc = W8 Hotse faces: N
2018-Oct-02165456
Page 1
-�- Viin , tsoft Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove CoLn Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wmrouOreStopCoolirg.com License: CAC032444
Job: Lot 064 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
Entire House
NEED
2
3
4
5
Exposed wall
Room height
Room dimensions
Roam area
158.0 ft
8.7 ft d
1853.3 R2
30.5 ft
8.7 ft heaUcool
13.5 x 17.0 It
229.5 it'
Ty
Construction
number
U-value
(BtuhV-00
Or
HTM
(Biuh/ff?)
Area (T)
or perimeter (ft)
Load
(Btuh)
Area (ftF)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
��11�
?- +r
13A-floc -,
'4A5 tom.
13A-4ocs
0143
-0.540
0.143
n .
_ n
a
372
_. 1404,
3.72
2.62
- 13.31,
2.62
248
.16
265
232
0
196
861
229
730
V 806
218
514
O
0
0
_ a_.._0
.. :0
0
.,0
0
_ ___..0
0.
0
11
LIS4A5-2om
_
V�J,�
t - G
11 DO
13A-4acs � �• •
4A5 20m_. _.
13A-flocs
0.540
0.390
- -
0.143
... 0.540
0.143
a
a
-
s
- s ..
w
14.04
10.14
3.72
. 14.04,
.3.72
28.62
11.50
2.62
_ 13.31..
2.62
49
20
--
; 422
_-3
439
0
20
419
--3
337
688
204
1558
-- ` 3
1252
1403
231
1096
-40
881
0
0
148
_ .--.0
117
0
_ 0
148
- _.0
85
0
� 550
. _ _ ..__-0.
315
0
387
__., a
222
R II
�`-.-D_
C
4A5-2om
4A5.2omd
12 C Osw.
11D0 . _ .. _ .. _..
16B-30ad
0.540
0540
_. 0 091
0.390
0.032
w
w
-
--n-
14.04
1404
2 37
-- 10.14
0.83
28.62
32.78
1:33
,. 11.50
1.70
49
54
348
.._ _ . 1$
1853
0
0
330
_ . _ .18
1853
688
753
781
.-- _ 181,
1542
1403
1757
439
.. 206
3143
33
0
-0-8
_ 0
230
0
0
_ _ 0
230
459
.0
_ _ . -0
_ _0
191
936
0
- 0
0
389
F
- - -
0,00
. _ 1853
158
_ -_ 4847
-- 0
230
_,31
936
-
6
c)IAED
excursion
570
252
Envelope loss/gain
14357
12507
2451
2186
12
a) Infiltration
2918
1063
563
205
b), Room ventilation
0
0
0
0
13
Internal gains: Occupants 230
4
920
2
460
Appliances/other
1700
0
Subtobl(lines 6to13)
17275
16190
3014
2851
14
15
Less extemalload
Less transfer
Redistribution
Subtotal
Ductloads
10%
22%
0
0
0
17275
1765
0
0
0
16190
3491
10%
22%
0
0
0
3014
308
0
0
0
2851
615
Total room load
Ai required (dm)
19039
0
19681
933
3322
0
3466
164
-�- wrYgFitsoTt�
Right-SLAe®Uriversal201818.0.31 RSU16877
ktop\TEMP PRINT\Lot 064 F1833 B RHG Den- N.rup Calc= W8 House faces: N
2018-0ct-0216:54:56
Page 1
-- wrightsoft° Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOr eStopGoolirg.com License: CAC032444
Job: Lot 064 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
i
Room name
MBTH
MWIC -
2
E)Vosedwall
15.0 ft
0 ft
3
Room height
8.7 ft heaU000l
8.7 ft heat/cool
4
Room dimensions
1.0 x 107.5 ft
7.0 x 11.0 ft
5
Room area
107.5 ftz
77.0 ftz
7y
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh*--q
(Btuh/ft?)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
t,, G
3A flocs - , -
4A5-2om
13A-4ocs
0143
0.540
0.143
n '
n
a
3.72
. 14.04
3.72
2.82
, - 13.31...:
2.62
0
; 0
0
0
0
0
- - 0
_ .. 0
0
6
. _ - 0
0
0
- _ - .- 0
0
- Q
- .. _ 0
0
0.
0
- 0
0
11
4A5.2om
11 D0
0.540
0.390
a
e
14.04
10.14
28.62
11.50
0
0
0
0
0
0
0
0.
0
0
0
0
0
0
0
0
1�1�
LL-
13A4acs
4A5 tom.
13A-4ocs
0143
0.540
0.143
-s
s
w
3.72
14.04
3.72
2.62
- 13.31.
2.62
' 131
_ 3
0
127
....3
0
-- 474
. _43
0
334
4Q
0
0
0
0
0
..0
0
0
_ __ -0.
0
0
_. 0
0
L._.G
4A5.2cm
4A5-2omd
0 AD
0540
0 091
w
w
14.04
14.04
237
28.62
32.78
133
0
0
0'
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
'- D
C
11D0 _�_. _
16B-30ad_
0390
0032
n._
1014
083
11.50
1.70
,_0
108
,. 0
108
0
89
0
182
0
77
0
77
0,
64
0
131
F
22A cpm
1 180
30.68;
0.00
108
15
- 460
_ .
0
- 77
_0
0
- 0
6
c);AED excursion
-42
-8
Envelope loss/gain
1066
514
64
122
12
a)' Infiltration
to� Room ventilation
277
0
101
0
0
0
0
0
13
Internal gains: Oaupants@ 230
Applianoes/other
0
0
0
0
0
0
Subtotal (lines 6 to 13)
1343
615
64
122
L6-.e)demallead
0
0
0
0
Lesstransfer
Redistribution
0
0
0
0
0
0
0
0
14
Subtotal
1343
615
64
122
15
Ductloads 110%1
229/.
137
133
10%
22%
7
26
Total room load
1480
748
71
149
Alr required (dm)
0
35
0
7
Calculations approved by ACCA
-�- wrigtitsoft�°
Right-SuiteOUniversal 201818.0.31 RSU16877
ktop\TEMP PRIN11Lot064 F1833 B RHG Den- N.rup Calc= W8 House faces: N
2018-Oct-0216:5456
Page 2
i
-�- wrightsoRight-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sar?dscove Gout, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC032444
Job: Lot 664 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
i
Room name
DEN
FOY
2
3
Exposed mall
Room height
30.0 ft
8.7 ft heaU000l
5.5 ft
8.7 ft heat/cool
4
5
Room dimensions
Room area
13.5 x 13.0 ft
175.5 ft2
5.5 x 6.5 ft
52.3 ft2
ly
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (T)
Load
number
(Btuh/T!-°n
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
VN,
13A-4ocs
4A572om
13A-4ocs
0.143
_,.0.540
0.143
n
_. n-
e
3.72
,I 4.04
3.72
2.62
13.31;
2.62
30
_0
117
- 30
.. _ ._0
lot
113
0
376
- 80
._ --. , 0
265
0
.0
48
0
28
0
103
0
73
11
4A5-2om
11 DO
OL40
0.390
a
a
14.04
10.14
28.62
11.50
16
0
0
0
229
0
468
0
0
20
0
20
0
204
0
231
yJ
U-G
13A flocs -'
A4A52om _
13A-4ocs
0143
- 0540
0.143
s
s
w
3.72
_ 14:04
3.72
2.62
133s1
2.62
113
.-....._ -0.-
0
113
_ _.. 0.
0
421
_. -0
0
296
_ 0
0'
0
.. 0
0
0
-".0
0
- 0
- - 0.
0
0
0
0
Fj �; ..
4A5-2am
4A5-2omd_
12C Osw
0.540
0540
0 091
w
_w
14.04
14.04
2.37
28.62
32.78
1.33
0
0
, :, . 0
0
0
0
0
0
... _ 0
0,
0
_• o
0
0
. _ 0
0
0
0
0
0
0
0,
0
_ . 0
r-' D
G
11D0__ _.. _
16B-30ad
0390
0.032
...n.
1.0.14
0.83
11 50
1.70
.. _,0
176
. .. _ -_0
176
_. __ 0
146
._ . _,.0
268
_ . "---0
52
_-. 0
52
_ 0
43
-.0.
89
F ,
22A g7m-. • ' .
1.180
30.66-
0.00
176
- -_ ., 30
- _ .. 920
. .._. 0
--. - - - 52
6
169
. 0
6
c)IAED excursion
-11
-27
Envelope loss/gain
2205
1395
519
365
12
a) Infiltration
554
202
102
37
b) Room ventilation
0
0
0
0
13
Intemalgains: Occupants@ 230
0
0
0
0
Appliancestother
0
0
Subtotal (lines 6 to 13)
2760
1597
621
409
Lessexternal load
0
0
0
0
14
15
Lesstransfer
Redistribution
Subtotal
Dud loads 1101%
221/6
0
241
3000
306
0
156
1753
378
10%
221/.
0
-621
0
0
0
-402
0
0
Total room load
3307
2131
0
0
Air required (dm)
0
101
0
0
-F$d- wrigFttsoft-
Right -Suite® Universal 2018 18.0.31 RSU16877
ktop\TEMP PRINMot064 F1833 B RHG Den- N.rp Calc='W8 House faces: N
2018-Oct-0216:54• %
Page 3
+ wrightsoft Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 624 - 9307 Web: wwwOneStopCooling.00m License: CAC032444
Job: Lot 064 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
DIN
Krr .
2
3
Exposed wall
Room height
15.0 It
8.7 It heaUcool
0 It
8.7 It heaU000l
4
5
Room dimensions
Room area
11.5 x 13.0 It
149.5 V
1.0 x 324.0 ft
324.0 ft'
Ty
Construction
number
U-value
(Btuh4t2-On
Or
HTM
(BtuW)
Area (ftz)
or perimeter (ft)
Load
(Btuh)
Area (ftz)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
yJj -
13A-46cs • _ _
4A5-2om:
13A-4ons
4A5-2om
11 DO
13A-4ocs
19A-4ocs
- -
- 0.143
OW
0.143
0.540
0.390
0143
0 540
0.143
n
.n-.
a
a
a
`s .
.. s
w
-
3-.72
14.(4
3.72
14.04
10.14
--
3 72
14 04,
3.72
2.62
-_ 13.31
2.62
28.62
11.50
2 62
13 31,
2.62
" - 0
0
100
33
0
- , 30
0
0
- - 0
,.__o
67
0
0
30
0-
- 0
- - ---0
_. 0.
250
459
0
113
a
0
- - --0
_0
176
936
0_
80
_ _ _ . 0
0
_ _0.0
0
0
0
0
' 0
_. - . . 0
0
-0
0
0
0
0
_ 0
0
_ 0
-0,
0
0
0
0
._. - - .:0
0
0.
_ _0
0
0
0
0
... ... __0
0
-_,
U��J,I
�l
G
^
L
q
L--D,
C
4A5-2om
4A5-2omd _
12C Osw
11D0._-_.. . - :.
16B-30ad
0.540
0540
- -0091
0390
0.032
w
w
-
n_..
14.04
14.04
2.37
.10.14
0.83
28.62
3278
1 33
_.
__11.50
1.70
0
0
113
...... -0
150
_-..150
0
0
113
-._.-0
150
--15
0
0
-,- 268
- . _ _.,0
124
460
0
0
150
_ :- 0
254
- 0
0
0
81
.- - _.0.
324
_ -324
0
0
• 61
_ ..0
324
0
0
0
' 144
_- 0
270
..-.0
0
0
81
.__�A
550
0
6
c) AED excursion
76
-117
Envelope loss/gain
1675
1671
4141
514
12
a) Infiltration
277
101
0
0
b) Room ventilation
0
0
0
0
13
I96mal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
1200
Subtotal (lines 6 to 13)
1952
1772
414
1714
Less external load
Le'sstransfer
0
0
0
0
0
0
0
0
Redistribution
241
156
142
96
14
Subtotal
2192
1928
556
1809
15
Ductloads
10%
2291.
2241
416
10%
22%
'57
390
Total room load
2416
2344
1
613
2200
Air required (cfm)
0
111
0
104
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
r - - wr7gNtsoi tp 2018-Oct-0216:54:56
Right-Sdte®Universal 201818.0.31RSU16877 Page
Idop\TEMP PRINT\LotO64 F1833 B RHG Den- N.rup Calc= W8 House faces: N
-1"�- wrightsoft Right-M Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wmLOneStopCooling.com Licerse: CAC032444
Job: Lot 064 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
GRT
BTH1-
2
Fposed wall
17.0 ft
6.0 ft
3
Roam height
8.7 ft heaU000l
8.7 ft heaU000l
4
Room dimensions
17.0 x 14.0 ft
1.0 x 79.5 ft
5
Room area
238.0 flF
79.5 ft2
Ty
Construction
number
U-value
(BtuhAlt--q
Or
HTM
(Btuw)
Area (tiz)
or perimeter (ft)
Load
(Biuh)
Area (fp)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P5
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Vdh
73A flocs --
0.143
n
3.72
02
' - 0
0
O
-0
-
_ -0
- 6
- 0
4A5.2om_ _:. _
13A-4ocs
O540
0.143
-_n
e
14.04
3.72
13.31,
_ 2.62
_ ,- 0
0
. 0
0
...- --0
0
0
0
0
0
-_ 0
0
.- . 0.
0
- 0
0
4A5-2om
0-40
a
14.04
28.62
0
0
0
0
0
0
0
0
11
11DO
0.390
a
10.14
11.50
0
0
0
0
.0
0
0
0
W I
-
13A-flocs
0143
s
3J2
2.62
0
0
0
0
0
T
0
0
0
4A5-tom_ _ _ _ -_.._
13A-4ocs
_ _0 540
0.143
.. s ..
w
14.04
3.72
13.31
2.62
0
148
0
94
0
351
0
247
..., ---0
52
_--- ...0
52
____ _ .. __0
194
_. .. _ _ ..0.
137
_
4A5.2om
0.540
w
14.04
28.62
0
0
0
0
0
0
0
0
4A5-2omd
0.540
w
14.04
32.78
54
0
753
1757
0
0
0
0
R
12C-0sw
0 091
2.3
1.33
-0
0
70-
-0
0
- 0
C
11D0.--._.. _ .. _ _.
16B 30ad
0390
0.032
_.n_.
10.14
0.83
1150
1.70
:0
238
0
238
_ .. 0
198
: _ ...._A
404
_ .. - ...0
80
- - ..p
80
: _--0.
66
-. .... 0,
135
1 180
90.68
_ .._ 000
- 238
17
522
_ ... -0
80
., 6
184
.. 0
{
6
c)IAEDexcursion
503
-20
Envelope loss(gain
1823
2911
444
252
12
a) Infiltration
314
114
111
40
b)' Room ventilation
0
0
0
0
13
Internal
gains: Occupants Qa 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
12137
3025
555
292
Lessexternal load
0
0
0
0
Less transfer
Redistribution
0
3
0
6
0
9
0
17
14
Subtotal
2140
3031
564
309
15
Duct loads
10 %
22°/,
219
654
10%1
229/6
58
67
Total room load
2358
3684
622
375
Air required (cfm)
0
175
0
18
J 8th Ed.
-rw wrtigFrtsoft-
Right-Suite®Uryversal201818.0.31 RSU16877
ktop\TEMP PRINT\Lot064 F1833 B RHG Den- N.np Calc= MJ8 Hose faces: N
2018-Oct-0216:54:56
Page 5
- I- wrightsoft Right-M Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ww&CneStopCooling.com License: CAC032444
Job: Lot 064 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
BED2
AC
2
3
Exposed wall
Room height
26.0 ft
8.7 ft heaUcool
0 It
8.7 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 160.5 ft
160.5 ft2
5.5 x 3.5 ft
19.3 ft2
T,y
Construction
number
U-value
(BtuhRtz`n
Or
HTM
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/PS
Heat
Cool
6
11
-----DDD
1�4oas " _
4A5-2om
11D0
13A-4ocs
4A�2om- _ :.
13A-4ocs
0.140
0S40
-0_390
0.143
0 540
0.143
_'e
a
a
. ,s
_s -
w
13.72
14.04
10.14
3.72
14.04.
3.72
A33:1
28.62
11_50
2.62
_ .13.31;
2.62
.... - 1 a
0
0
0
._; A
122
-.`j 0''
0
- - --- 0
, . 0
105
... 388•
0
-- - .. 0
0
392
... 27a
0
0
0
276
. _._. 00
0
-------.__0
0
0
0
0
-0
. 0
0
o
0
0
- 0
0
.00'
0
- - 0
0
0
T�
. ,
C '
4A5-2om
4A5 2omd
,12C Osw
11D0:__. - ...
168-30ad
0.540
0.540
0 091
_0390
0.032
w
_ w
_n.
14.04
14.04
2.37
10.14
0.83
28.62
32.78
1:33
11LO
1.70
16
0
0-'
. :A
161
0
0
0
. -__0
161
229
,. 0__
0
_ 0
134
468
0
0
_ .. -
272
0
0
0
..- _
19
0
0
0
-: .0
19
0
0
0
- _ _0
16
0.
0
0
_- �.
33
i
-qom . - --
-1 180
-_ --
- -- 30,68_
_.._-..
. 0.00
_ ..... ......
_ - 61,
. _ _.._ _.__._
26
. _ .- --------
_ 798
_ _ 0
_ _.. 19
.. - - - . 0
0
0
6
c)iAED excursion
101
-2
i
En, velope loss/galn
1941
1390
16
31
12
. a) Infiltration
480
175
0
0
b)� Room ventilation
0
0
0
0
13
Internal gains: OocupantsOa 230
1
230
0
0
Appliances./other
0
0
Subtotal (lines 6 to 13)
2421
1795
16
31
Less odemal load
0
0
0
0
Lesstransfer
Redistribution
0
5
0
10
0
-16
0
-31
14
Subtotal
2426
1805
0
0
15
Dudloads
IN
22%1
248
389
10%
229%
0
0
I
Total room load
Air required (cfm)
2674
0
2194
104
0
0
0
0
-�- wr'Yghtsof't�
Right-Sdte®Uriversal201818.0.31 RSU16877
ktop\TEMP PRINi\Lot064 F1833 B RHG Den- N.rup Calc= W8 House faces: N
2018-Oct-0216:54:56
Page 6
-�- wrightsoft° Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Cart, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC032444
Job: Lot 064 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
BED3
LAUN
2
3
Exposed well
Room height
13.0 ft
8.7 it heaUcool
0 It
8.7 it heaU000l
4
5
Room dimensions
Room area
1.0 x 154.8 ft
154.8 ft2
1.0 x 48.0 it
48.0 ft2
iy
Construction
number
U-value
(Btuh4l�-09
Or
HTM
(Btuh/ftz)
Area (ft2)
or perimeter (it)
Load
(Btuh)
Area (it)
or perimeter (ft)
Load
(BWh)
Heat
Cool
Gross
NAS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
W
t r_
yJ1 --
13A 4ois
4A5.2om . -
13A-4ocs
4A5-2am
11 DO
13Aflocs ..: -
4A5 tom.
13A-4ors
_.
0540,-n_
9.143
0.540
0.390
--0143
0.143
n
a
a
a
s
s.13,31
w
3.72
__14.04
3.72
14.04
10.14
..3.Z2
3.72
2:62
13:31
2.62
28.62
11.50
2.62
113
i6.
0
0
_0 0
0
0
- 97
.-. 0.
0
0
0
_.. _ 0
0
0
- 360
._ 229
0
0
_- 0
0
0
253
218'-'_
0
0
0
0
0
0
0
0
0
0
. .. 0
0
0
_ 0
0
0
0
. _ _ 0
0
0
_ 0
0
0
0
0
0
0
0
0
0
0
� '0
-0
0
Fj
4A5-20m
4A5-2omd
12C 06w
0.540
0.540
0.091
w
w
14.04
14.04
2'.37
28.62
32.78
1.33
0
0
117
0
0
117
0
0
278
.0
0
- ib6
0
, 0
57
0
0
39
0
0
92
0
0
51
!-D
C
11D0-_-,
168-30ad
0.390
0.032
A
_10.14
0.83
_ 1150
1.70
.-,- .0
155
_.-._0
155
_:. ..,_.0
129
_0
262
18
48
18'
48
181
40
,-- 206
81
F j
22A.c{�rn-`
1.180
.-
30.68
0.00
, . _ ,155
13
_399-
-. 0--
-
..-48
... --
-0
-. 0
_
_
- 0
6
c),
AED excursion
-T7
-54
i
Envelope lossrgain
1395
812
313
285
12
a) Infiltration
240
87
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
1
230
0
0
Appliances/other
0
500
Subtotal (lines 6 to 13)
1635
1130
313
785
Less external load
0
0
0
0
14
15
Lesstransfer
Redistribution
Subtotal
Dud loads
10%
221/.
0
14
1649
168
0
27
1157
249
10 %
22%1
0
13
326
33
0
26
811
175
Total room load
1817
1406
359
985
Air required (drru)
01
67
0
47
to meet all requirements of Manual J 8th Ed.
wrYgF�tsotr't°
Right-SLiteO Uriversal 2018 18.0.31 RSU16877
ktop\TEMP PRINMot064 F1833 B RHG Den- N.np Cale= W8 House faces: N
2018-Oct-021654:56
Page 7
-�- wrightsoftRight-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sari stove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wmOneStopCooling.com License: CAC032444
Job: Lot 064 F1833 B RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
H1 -
2
Exposed wall
0 ft
3
Room height
8.7 It heaU000l
4
Room dimensions
9.5 x 4.0 ft
5
Room area
38.0 Its
Ty
Construction
number
U-value
(BtuhAt--n
Or
HTM
(Btuw)
Area (W)
or perimeter (ft)
Load
(Btuh)
Area
or perimeter
Load
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-4ois -
-6.143
- n
3.72
-2.62
.. 0
- Q-
4A5-2om
0.540
n
14.04
13:31.
_ :. 0
.0
0
01
_
13A-4ocs
0.143
a
3.72
2.62
0
0
0.
0
4A5-2om
0.540
a
14.04
28.62
0
0
0
0
11
11D0_
13A flocs
4A5 2om__ .. _.__
13A-4ocs
0.390
AT 43
_0,540
0.143
a
s
s_ .
w
10.14
3.72
_ 14.04.
3.72
_ 11.5LO_
2.62
13:3.1
2.62
0
0
0
0
0
0
- ._ _ ..0
0
0
0
_ - _ 0
0
0
0
___-.__. . _._0
0
y✓,
r
t
'__ G
4A5-2om
0.540
w
14.04
28.62
0
0
0
.0.
R
D
4A5.2omd
12C-0sw .
0.540
0.091
w
=
14.04
2.37
32.78
1.33
0
0
0
0
0
0
0
- 0
11 D0 _
_' 0 390
n
1014
11.50
0
- 0
_0
0
C l
168-30ad
0 032
0 83
in
38
38
32
64
F
i
22A �m ; - . _.
-
-_;1180
30.68
_ 0.00:
_..
-0
__
0
_
i
6
c) IAED excursion
-4
Envelope loss/gain
32
60
12
a)j infiltration
0
0
b)j Room ventilation
0
0
13
Internal gains: Occupants@ 230
0
0
i Appliances/other
0
Subtotal (lines 6 to 13)
32
60
Less external load
0
0
L.esstransfer
0
0
14
Redistribution
Subtotal
-32
0
60
0
15
D6ctloads
10%
22%
0
0
Total room load
0
0
Air required (cfm)
0
0
Calculations
-�- wrigNts4M7.
Right-Surite®Uriversal201818.0.31 RSU16877
ktop\TEMP PRINMot064 F1833 B RHG Den- N.rup Calc= W8 House faces:
2018-Oct-0216:54:56
Page 8
- rightsofto Duct System Summary
Entire House
One Stop Cooling and Heating
7225 Sarj stove Coot, Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: w mOneStopCoolirg.com License: CAC032444
For: Ryan Homes
FL
Job: Lot 064 F1833 B RHG Den...
Date: 06/07/2017
By. XF/MC
I
Heating
Cooling
External static pressure
0.50 in H2O
0.50 in H2O
Pressure losses
0.16 in H2O
0.16 in H2O
Available static pressure
0.34 in H2O
0.34 in H2O
supply'/ return available pressure
0.170 / 0.170 in H2O
.0.170 / 0.170 in H2O
Lowest friction rate
0.228 in/100ft
0.228 in/100ft
Actual !air flow
0 cfm
933 cfm
Total effective length (TEL)
149 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BED2
c 2194
0
104
0.292
6.0
Ox 0
VIFx
11.6
105.0
sti
BEDS
c 1406
0
67
. 0.305
6.0
Ox 0
MFx
11.3
100.0
sti
8TH1
C 375
0
18
0.266
4.0
Ox 0
VIFx
12.9
115.0
sti
DEN
c 2131
0
101
0.233
6.0
Ox 0
VIFx
35.7
110.0
st2
DIN i
c 2344
0
111
0.234
5.0
Ox 0
VIFx
35.1
110.0
st2
GRT
c 3684
0
175
0.228
8.0
Ox 0
VIFx
29.2
120.0
st2
Krr
C 2200
0
104
0.253
5.0
Ox 0
VI Fx
24.5
110.0
st2
LAUN
C 985
0
47
0.466
4.0
Ox 0
MFx
3.0
70.0
IMBED
C 3466
0
164
0.240
7.0
Ox 0
VIFx
31.4
110.0
st2
MBTH
C 748
0
35
0.230
4.0
Ox 0
MFx
32.9
115.0
st2
MWIc
c 149
0
7
0.239
4.0
Ox 0
VIFx
27.0
115.0
st2
Trunk
Htg
Gig
Design
Veloc
Diam
H x W
Duct
Name
Type
(Cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
PeakAVF
0
698
0.228
653
14.0
0 x 0
VinlFlx
sti
PeakAVF
0
188
0.266
705
7.0
0 x 0
VinlFlx
Boldrdalic values have been manually overridden
i
-*- wrightsoft®
2018-Oct-021654:57
.,e.�..w� Right -Suite® Universal 2018 18.0.31 RSU1 6877 Page
/ p ...ktop\TEMP PRIN7\Lot 064 F1833 B RHG Den- N.np Calc= W8 House faces: N
Grille
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FIR
(fpm)
(in)
(in)
Opening (in)
Mat
Trunk
rb1
Ox 0
0
933
0
0
0
0
Ox 0
VIFx
-�- wrightsoft® 2018-Oct-0216:54:57
Right-SUte®Uriversa1201918.0.31 RSU16877 Paget
ktop\TEMP PRINTIot064 F1833 B RHG Den- N.np Calc= NU8 House faces: N
i
I
-- wrightsoft® Static Pressure and Friction Rate
Entire House
One Stop Cooling and Heating
7225 Sardscove Coul, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: mmOneStopCooling.com License: CAC032444
For: Ryan Homes
FL
Job: Lot 064 F1833 B RHG Den...
Date: 06/07/2017
By. XF/MC
External static pressure
0.50
0.50
Pressurelosses
Coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
AvaiLle
0.34
0.34.
static pressure
Total•
Supply
Return
(ft)
(ft)
Measured length of run -out
9
0
Measured length of trunk
20
0
Equivalent length of fittings
120
0
Total length
149
0
Total effective length
149
FrictionRate
Heating
Cooling
(in/100ft)
(in/100ft)
Supply Ducts
0.228 > 0.18
0.228 > 0.18
Return Ducts
0.228 > 0.18
0.228 > 0.18
4X=35,11 A=20,11 G=5,11 G=5,11 G=5,1 A--35,11 G=5,11 G=5,11 G=5: Total EL=120
Total EL=0
-�- wrightsoft, 2018-Oct-0216:54:57
Right-SLnte®Universal201818.0.31 RSU16877 Page 1
ktop\TEMP PRINT\Lot 064 F1833 B RHG Den- N.n p Calc= M.18 Horse faces: N
r
AC PADS BY GC MIN SIZE
aa'X40'
SS' SEPARATION
15' OFF WALL
V PVC REFRIG LINE CHASI S
BY GC
EF1 = 50 CFM Fan
EF2 = 80 CFM Fan
EF3 =110 CFM Fan
EFL1 = 50 CFM Fan
EFL2 = 80 CFM Fan
EFL3 =110 CFM Fan
VTR = Vent to Roof
VTW = Vent to Wall
DV = Dryer Vent
RV = Range Vent
— — = Lineset Chase
- - = Condensate
OT = Thermostat 18/8
SRB = Small Reduction Box
LRB = Large Reduction Box
FBB =Field Built Box