HomeMy WebLinkAboutPERMIT WORKSHEETInstaller kNJ,l ?s �, �x� i� ' -i rvoi i fD tse i
l�ddra s of.homa cam
6eTtzg Iiisil6C1
A+Zaji4'tac utel- -Z'�Aengih x wlcifh 100 % C-0 --
NOM— -If home Is a s1nale wide fill oot one half of the hfocldng plan
Y}hord a is a irTple or quad wide sketch In raamrrder of home
.I understand Lateral km Systems cannot be used on any home (ne�
wfters the sldewall ties wmeed 5 ft 4 ki:
Instailet;s hKals
Typical pier spacing-
`-� tutu.:
T
udmal andloUcadaiiraSysemst
rinestoso o
PER -MIT WOf3?��HEET SC 1NY � - [ page l of 2
New Home - used HSt LUC ()unit'
ome ,
[come installed to the Manufacteasr's In-'Watlon Manual
HDme Is installed in accordance vAth Rule 15C _
Single wide ® tnd Zone iI i��WWzbnqlft []
Double wide �nsta"on Decati 3L0��
WoEiQaad F-1 Serkt
PIEn SPAONG TABLE FOR USED HOMES
LE2:rI Footer �cxis
be mg size (256)
38YJ2 X18t!2` 2WxOr
(342) (400)
22'x2Z- 24•X24•
(4Ur (676)`
-WX26-
(676)
I
8 s
WOO Vs
s
�!� _ _ i♦ `� rTi7JXURA
IN
ii/i:77ii1�`k`T'���
ME
iL<ifL•3�;:fIL•���
■ i ! ■ ■ ��iF7L�
•.
■!ii#■i!!S!!!!!!!liia!! -
�i!!0!lileillElitilsil,i!
■■■�!■ilii■i!!!!i•i■i!
■iii•iItlQiil:�ili■itslti .. .•. , - . •
�iliiiiiii!•iiiilii)titi .,
■iitiii�/iilii!■iill, . , - _ ,
■iisliiii!!!!■!!S!!!i
■litllli!•ii!•i!1•■liiiiifir. , -. • .,
X X X
POCKET PENE>i AOMEJ TFS I IND NI)=MD
f. Test the perimeter of the horhs at 6 loca lom
2 Take the reading at the depth of the rooter
9` U;img 500lb, kmarnag take the lowest -
reading and round down to that incrernerrt.
X X X
OBE TEST
The results of the torque probe test Is Inch pounds or check -
hem If you are declaring 5 anchors %Mod testing - A test .
showing 275 inclr pounds or less M require 5 foot anc hom
Noes; A state approved lateral arm cyfstem Is being used and 4 fL
anchors are allowed ad -the sidewatl locations: I u idersiand 5 ft
andmrs are required at all ceaierltne tie pouts where the torque test
reading Is 275 or less and where the mobile home manufacturer may
requires anchom with -0OeOi ... Wrr,g capeciiy.
. - --_.•_ ;itis#aller's friitiats
ALL TESTS MUST BE P$iFOR ED BY A Llt;l ISED IJYSTAi_i..ER
tnstalter Name
_ DateTas[ed`� fir\ : - .
Connect 0Ie0ticW conductors between multi -wide units, bat not to the main power
awce. This Irr �Ituies the bonding wire between mutt -wide ta3its Pg
crated-a1I sewer drains to tn edsting sewer tap -or septic tank. PA
onnect all potable water supply pipf ng to an existing water meter, water tap, or other
,dependent water supply systems, Pg_
PERMIT WORKSHEET
site Prcparatmon
page 2 of 2"_
Debrls and organic material l rv4oved
Waterdrafnage: Natural �/ Slnrafs Pad plhw -
Fasteutrn mu38 wFtie traits .
Floor. Type fastener. Larluih spacing: �_
Walls: Type Fastener: Lengft
Boot: Type Fastener. Length � y %. -- —
For -used homes a So gauge, aw" vvrdey w m' --
will be centered over the peak of thel=wf and fastened With gals.
roofing naffs at Z on center on both sides of the centedfne.
- 6nsket (.,rn4 L -
I understand a properly installed gasket is a raquirernent of all newand used
homes and that condensation, mold, meldsw and budded marriage walls are
a result of a poorfv installed or no gasket being installed I understand a strip
of tape will not serve as a gasket.
• 'fiisfallet'sInfitTais,..
Typegasket YOaM installed:
P9. Between Floors Yes ✓
Between Wafts Yes
Bottom of ridgebeam Yes _
-ibo bottomboard wr71 be repairedamyortaped,-
skfing on units is installed to matutfactureft meciffoatforss Yes —
Fireplace cdurnnsy fnstalled so as not to allow k1truslon of raft, water. Yes .
.,..,,w„�
SkWng to b0•bnstalled. Yes No
Dtysrvsnf installed outside of sldrfing. Yes
Rantle downtfow vent Instailed-outside of slfl
Drain fines supported at 4 foot intervals. Y
Electrical crossovers protected Yes
other: -
tns3ailer Sl
s aft information given with this permit
Is accurate and true based o:r the
IA