HomeMy WebLinkAboutFIELD LABORATORY REPORTUNIVERSAL UES Project No.: 0310.1700251.0035 02, 2019 = Date Typed: January ENGINEERING SCIENCES Consultants In:echnical Engineering • Environmental Sciences II Geophysical Services •Materials Testing •Threshold Inspection FILE COPY Building Code Administration, Compliance Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Construction Materialslesting Services FIELD AND LABORATORY REPORT COVER PAGE SCANNED BY Client: Ryan Homes St LUCIe COUnty 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 2 5210 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL "I��,1,,•�; t B it — O 3iz- As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials testing and/or field /inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summar2ed below: Scope of Work Work Order No. I Date I Type of Report 164854-1 1 12/28/2018 In -Place Density Test Report w/Activfty Record We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned. ECEIbED JAN 2 2 2019 Permitting Department St. Lucie County, FL I VIZ Did ,. No. �s7ss STATE OF Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00000549 Richard E. Hoaglin, P.E. 2019.01.03 15:15:38 . -05'00' Richard E. Hoaglin, P.E. FLORIDA Professional Engineer No. 48796 This item has been electmnlcally signed and sealed by Richard E. Hoaglin, PA using a Digital Signature. Printed copies of this document are not considered signed and seated and the signature must be venffed on any electronic copies. ICC Errlail: cbugg@nvdnc.com; elibrlhi@nvrinc.com; Imhoff, Bryan IBIMHOFF@nvrinc.com]; jomcalli@nvrinc.com; rofingar@nvrinc.com; sign/sea] MAIL to ryan homes at 1777 Willows Square, Vero Beach, FL 32966 ! I y y UNIVERSAL UUES ES DOCS Noo: 0310.1.700251.0036 ENGINEERING SCIENCES UES Report No: 105198-1 DT010819 Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32965 - P: 321.638.0808 - F: 321.638.0978 In -Place Density Test Report Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 73 5357 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL Tn -t-r- i8lf - a 39'2- Area Tested: House pad # 73. Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 01/08/2019 Lab: ASTM D1557 Modified Proctor Technician: Russell Brause Regluirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and do not address the condition of the underlying soils below the tested depths. Testj No. Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) Field Moisture % % Compaction Comments (3) 1 NW corner. 0 to -1 ft 12.00 21143 112.4 5.5 98 A 2 j SW comer. 0 to -1 ft 12.00 21143 113.1 8.9 98 A 3 SE corner. 0 to -1 ft 12.00 21143 112.6 7.7 98 A 4 i NE comer. 0 to A ft 12.00 21143 112.2 5.7 98 A (1) � Ref. Datum: 0 = Top of Final Grade (2) Maximum Optimum Proctor Dry Moisture # Density Content 21143 115.0 12.0 i This test was performed without deviation from ASTM procedures. (3) Comments Key A. Compaction meets min. requirements B. Compaction does not meet min. requirements C_ Moisture does not meet requirements D. Recompaction required E. Recompacted, Retested, Meets Requirements This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering 9 Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 • - F; LIES Project No: 0310.1700251.0036 UES DOCS No: UES Report No: 105198-1 ARC 010819 On -Site Time (hrs): 0.60 Lab Time (hrs): 0.00 Travel Time (hrs). 1.00 Total Time (hrs): 1.60 321.638.0978 Activity Record Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 73 J�a�r- -r 1811- 039 2- 5357 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL Date of Activity: Tuesday, 08 January, 2019 Technician: Russell Brause Asl requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of earthwork testing for the House pad # 73. Wiile on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House pad # 73.. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95%,of the maximum dry density per ASTM D-1557. The Contractor was notified of the test results or a copy was left for their records.