HomeMy WebLinkAboutFIELD LABORATORY REPORTUNIVERSAL
UES Project No.:
0310.1700251.0035
02, 2019
=
Date Typed:
January
ENGINEERING SCIENCES
Consultants In:echnical Engineering • Environmental Sciences
II Geophysical Services •Materials Testing •Threshold Inspection
FILE
COPY
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Construction Materialslesting Services
FIELD AND LABORATORY REPORT COVER PAGE
SCANNED
BY
Client: Ryan Homes
St LUCIe COUnty
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 2
5210 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL
"I��,1,,•�; t B it — O 3iz-
As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials testing and/or
field /inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summar2ed below:
Scope of Work
Work Order No. I Date I Type of Report
164854-1 1 12/28/2018 In -Place Density Test Report w/Activfty Record
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
ECEIbED
JAN 2 2 2019
Permitting Department
St. Lucie County, FL
I VIZ
Did
,.
No. �s7ss
STATE OF
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 00000549
Richard E.
Hoaglin, P.E.
2019.01.03
15:15:38 .
-05'00'
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has been electmnlcally signed and sealed by
Richard E. Hoaglin, PA using a Digital Signature. Printed
copies of this document are not considered signed and
seated and the signature must be venffed on any electronic
copies.
ICC Errlail: cbugg@nvdnc.com; elibrlhi@nvrinc.com; Imhoff, Bryan IBIMHOFF@nvrinc.com]; jomcalli@nvrinc.com; rofingar@nvrinc.com; sign/sea] MAIL to
ryan homes at 1777 Willows Square, Vero Beach, FL 32966
!
I
y
y
UNIVERSAL UUES ES DOCS Noo: 0310.1.700251.0036
ENGINEERING SCIENCES UES Report No: 105198-1 DT010819
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32965 - P: 321.638.0808 - F: 321.638.0978
In -Place Density Test Report
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 73
5357 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL
Tn -t-r- i8lf - a 39'2-
Area Tested: House pad # 73.
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 01/08/2019
Lab: ASTM D1557 Modified Proctor
Technician: Russell Brause
Regluirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlying soils below the tested depths.
Testj
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
NW corner.
0 to -1 ft
12.00
21143
112.4
5.5
98
A
2 j
SW comer.
0 to -1 ft
12.00
21143
113.1
8.9
98
A
3
SE corner.
0 to -1 ft
12.00
21143
112.6
7.7
98
A
4 i
NE comer.
0 to A ft
12.00
21143
112.2
5.7
98
A
(1) � Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
21143
115.0
12.0
i
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C_ Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering 9 Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 • - F;
LIES Project No: 0310.1700251.0036
UES DOCS No:
UES Report No: 105198-1 ARC 010819
On -Site Time (hrs): 0.60
Lab Time (hrs): 0.00
Travel Time (hrs). 1.00
Total Time (hrs): 1.60
321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 73 J�a�r- -r 1811- 039 2-
5357 Oakland Lake Circle, Fort Pierce, St. Lucie County, FL
Date of Activity: Tuesday, 08 January, 2019
Technician: Russell Brause
Asl requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad # 73.
Wiile on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House
pad # 73.. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
project compaction requirements of 95%,of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.