HomeMy WebLinkAboutENERGY EFFICIENCY CODE11 kn PON to m n FORM R405-2017 ,FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Fllorida Department of Business and Professional Regulation - Residential Performance Method Project Name: ' Lot 026 F1452 A RHG - W Builder Name: Ryan Homes Street: Permit Office: St. Lucie City, State, Zip: Ft. Pierce, FL, Permit Number: Owner Ryan Homes Jurisdiction: 661000 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1516.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1265.30 ft2 ' b. Frame - Wood, Adjacent R=11.0 251.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1452.0, sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1452.00 ft2 6. Conditioned floor area above grade (ft2) 1452 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(132.0 sgft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 290.4 a. U-Factor: Dbl, U=0.54 98.67 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.63 33.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 23.2 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 23.2 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.313 -14. Hot water systems I a. Electric Cap: 50 gallons S. Floor Types (1452.0 sgft.) Insulation Area EF: 0.900 a. Slab, -On -Grade Edge Insulation R=0.0 1452.00 ft2 b. Conservation features b. N/A I R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 49.82 Glass/Floor Area: 0.091 PASS Total Baseline Loads: 51.13 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this , p Code. DlgitallysignedbyBojan PaukoVic Bojan Paukovic calculation indicates compliance the Florida Energy Code. F. Apr "�� ate:z0,s.,o.oz,6:35:49 with ••:;:- . ;.��• ;� :O'. PREPARED BY: i -oaoo Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 0. *'°-'' I herebycertif that this building, as designed, is in compliance ; Y 9� 9 p Florida Statutes. •- with the Florida Energy C de. OWNER/AGENT: W� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certifie6 factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test -report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in i accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 On for whole house. 10/2/2011 4:33 PM EnergyGauge® USA Section R405.4A Compliant Software Page 1 of 4 FnRM R4f15-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: I Building Type: Owner'Name: # of U9Iits: Builder Name: Permit.Office: Jurisdiction: FamilylType: New/Existing: Comment: i Lot 026 F1452 A RHG - W Bedrooms: 3 User Conditioned Area: 1452 Ryan Homes Total Stories: 1 1 Worst Case: No Ryan Homes Rotate Angle: 0 St. Lucie Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 26 Block/Subdivision: Oakland Lake PlatBook: Street: County: St. Lucie City, State, Zip: Ft. Pierce , FL, i CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blocki 1452 12632.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil iD Finished Cooled Heated 1 Main 1452 12632.4 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 146 ft 0 1452 ft2 - - - - 0.29 0 0.71 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Tested Tested Insul. Pitch (deg) I 1 Hip Composition shingles 1573 ft2 0 ft2 Dark 0.5 N 0.5 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1452 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1452 ft2 0.1 Wood 10/2/2018 4:33 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS a nrnt F. Adjacent Cavity ity Width In Wall Typele Ft In Et Height In Area Sheathing Framing Solar RAInhe FrArJInn Ahqnr Below Grade% 1 S 2 W 3 N 4 E .5 Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block -. Int Insul Main Exterior Concrete Block - Int Insul Main Garage Frame - Wood Main 4.1 37 6 8 4.1 21 0 8 4.1 47 6 8 4.1 40 0 8 11 29 0 8 8 325.0 ftz 8 162.0 ftz 8 411.7 ftz 8 346.7 ftz 8 251.3 ftz 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0.25 0.5 0 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 2 W Insulated Main - Wood Main None None .4 3 .46 2 6 8 8 20 ftz 16 ftz WINDOWS Orientation shown is the entered, Proposed orientation. / v # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 S 1 Metal Low-E Double Yes W 2 Metal Low-E Double Yes N 3 Metal Low-E Double Yes E 4 Metal .Low-E Double Yes E 4 Metal Low-E Double Yes 0.54 0.31 N 0.54 0.31 N 0.54 0.31 N 0.54 0.31 N 0.63 0.32 N 16.4 ftz 1 ft 0 in 16.4 ftz 1 ft 0 in 16.4 ftz 1 ft 0 in 49.3 ftz 1 ft 0 in 33.3 ftz 1 ft 0 in 2 ft 0 in Drapes/blinds 2 ft 0 in Drapes/blinds 2 ft 0 in Drapes/blinds 2 ft 0 in Drapes/blinds 2 ft 0 in None i None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 393 ftz 393 ftz 64 ft 8.7 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholl house Proposed ACH(50) .000387 1473.8 80.91 152.16 ..2875 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 23.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 i Central Unit/ Split SEER: 14 23.2 kBtu/hr 696 cfm 0.75 1 sys#1 10/2/2018 4:33 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location. EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC'# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 290.4 ft Main 72.6 ft2 Proposed Qn Main --- cfm 72.6 cfm 0.05 0.50 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr j May jXj Jun jXj Jul jXj AugSe Oct Nov Dec HeatinJan Feb Mar E Apr f ] May ] Jun ] Jul [ ] Au4 SeP Oct Nov Dec Venting[ 1 Jan [ 1 Feb l l Mar lxJ Apr l ] May ] Jun ] Jul E E [ ] Aug [ Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule iiype 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 I PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (i EH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 i PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 'Main i i Name: Test Rater Rating Compant: Test Rater Signature: Date: 10/2/2018 4:33 PM I EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Reauirements for Residential Performance. Prescriotive and ERI Methods I ADDRESS: Permit Number: I j Ft. Pierce , FL , MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL ElR401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Se'ction 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of !Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal envelo-phe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. ❑ R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. ❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having, an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at anytime after creation of all penetrations of the building thermal envelope. i Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 10/2/2018 4:33 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS . (Continued) 402.4 ❑ R.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclo,ed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls Ithat, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0A inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.315 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. m R403.4,Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 1050F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 10/2/2018 4:33 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ®R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. + R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140OF (38°C to 600C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be.provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating ,equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. ❑ F1403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. I 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 I I 1062018 4:33 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less LJ '"^I^'"^^I Itdttll dbt t th 115t' t th th ttll d 1 Itd A t th d 1 td' a cu a e o a oa u no more." . Imes Urea. an e o a oa ca cu a e accor ing o e proce ure se ec e m 3.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the shall not be less than the calculated latent load. hed value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb ,e for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded -e data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. ues for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. xceptions: Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. J R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ 191403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40OF (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation i of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this I section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy,/such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 10/212018 4:33 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5 ❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory)he energy consumption of electric -powered portable spas shall be controlled by the requi ements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R40411 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 10/2/201 S 4:33 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 23.2 51 Is this a worst case? (yes/no) 5. No a) Split system SEER b) Single package SEER 14.0 c) Ground/water source SEER/COP 6; Conditioned floor area (sq. ft.) 6. 1452 d) Room unit/PTAC EER 7I Windows, type and area e) Other a) U-factor:(weighted average) 7a. 0.563 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.313 14. Heating system: Capacity 23.2 c) Area 7c. 132.0 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 1 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired; LPG EF l A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 C. d) Multizone cooling credit d) Radiant barrier installed 11 d. No - e) Multizone heating credit j f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatur Date: iCi 0 �L$ Address of New Home: _��� L,GIk.,�C Vxt4 Lr1 kCk'cL2. City/FL Zip: Ft. Pierce, FL 10/2/2018 4:33:43 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2011- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 026 F1452 A RHG - W Builder Name: Ryan Homes Strl et: Permit Office: St. Lucie Cit�, State, Zip: Ft. Pierce , FL , Permit Number: Y U Owner: Ryan Homes Jurisdiction: 661000 w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in.the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,' penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall, thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall --Ytpnd behind p'p'nn and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterio�,, walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/2/201!8 4:34 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 +;wrightsofto Project Summary Entire House One Stop Cooling and Heating 7225 Sandscove,Cout Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: w wOneStopCoolirg.com License: CAC032444 For: Ryan Homes Ff. Pierce, FL Notes: Job: Lot 026 F1452 ARHG - W Date: 06/06/2018 By. RI/MC Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 68 OF Inside db 72 OF Design TD 26 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 68 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15406 Btuh Structure 13810 Btuh Ducts 2627 Btuh Ducts 2813 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18032 Btuh Use manufacturer's data n Rate/swing multipplier Equipmenl load 0.95 15792 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3035 Btuh Ducts 699 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1453 1453 Equipment latent load 3734 Btuh VOlume (ft3) 12639 12639 Air chaues/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 19525 Btuh Equiv. AVF (cfm) 95 48 Req. total capacity at 0.75 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfqq. Make Goodman Mfqq. Trade GOODMAN;JANITROL;AMANADISTI... Trade GOODMAN;JANITROL;AMANADISTI... Model GSZ140241 K Cond GSZ140241 K AHRI ref 7995055 Coil ARUF25B14A AHRI ref 7995055 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating Input Sensible cooling 17400 Btuh Heating output 23200 Btuh Qa 47°F Latent cooling 5800 Btuh Temperature rise 27 OF Total cooling 23200 Btuh Actual airflow 773 cfm Actual airflow 773 cfm - Air flow factor 0.043 dmBtuh Air flow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point = 36 OF Backup: Input = 9 kW, Output = 29982 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. t - wri-ghtsoft® 2018-Oct-0216:31:37 ACCK Right-SLite®Uriversal2018 18.0.31 RSU16877 Page 1 1Desktop\TEMPPRIM\-ot026F1452ARHG-W.np Calc=MJ8 Front Doorfaces:.W - wrightsoft, Right-J® Worksheet. Entire House One Stop Cooling and Heating 7225 Sarlidscove Cocrt, W irrter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwKOneStopCooling.com License: CAC032444 Job: Lot 026 F1452 A RHG - W Date: 06/06/2018 By. RUMC 1 i Room name Entire House DIN 2 xposed well 146.0 ft 20.5 It 3 Room height 8.7 It d 8.7 It heaUmol 4 Room dimensions 11.0 x 9.5 ft 5 F oom area 1452.8 ftz 104.5 ftz ly Construction number U-value (BtuhAB--n Or HTM (Btuh/fF) Area (fF) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NrP/S . Heat Cool Gross N/P/S Heat Cool 6 I 1M 13A 4ois - 13A-4ocs . , 0143 0.143 n n.. a 3.72 14.04..- 3.72 2:62 _ 14.36 2.62 4.13 _--_ ._- 16 348 397 . ...-.___ _ a 265 1476 :. _ _229 987 - 1039 -'235 695 _ - 83 _ -:4 96 v -� �'83 62 307 231 216 163 11 !L-GG r 4A5-2om 485-22md 13A-4ocs 4A52om- _... 13A-4.. 0.540 0 630 0143 .-._._ _0.540 0.143 a a s _.5-- w 14.04 16.38 3.72 .---1,404 3.72 34.14 42.09 2.62 .' _ 14.36 2.62 49 34 -326 _ .-..16 183 0 0 1310 ._ _ __33 146 688 549 1152 _._..--229 544 1674 1410 : 811 -.._ 235 383 0 34 - 0 .___0 0 0 0 0 ._ _.0 0 0 549 0 _ _...__0. 0 0 1410 6 __ . _:...�. 0 4A5.2om 11 D0 0.540 0.390 w w 14.04 10.14 34.14 11.50 16 20 0 20 229 204 558 231 0 0 0 0 0 0 0 . _.- Q. R i 2C 0sw - 6.661 -- 2 37 1:33 _ 252 236 _ 559 _ 31.4 0 _.. - . 0 . _. _ .. 0 _ . 0 C ___ .__0.390 16B-30ad 0 032 -n. --- 10.14 0.83 11.50 1.70 __------- 16 1453 -•-i6.... 1453 ._-162 1209 _... ._164 2464 _. 0 105 ...__.--� 105 _ - .Q 87 - -- 177 F 22A tpm _ :.. _ _ _ .. -1 180 _ __ 30.6$ - , 0:00 - _ 1453 146 4479 Q - 1Q5 . . _.21. - - - .-. J. 6 c) AED excursion 0 0 Envelope lossrgain 12697 10231 1803 1966 12 i a)I Infiltration 2709 958 380 135 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 4 920 0 0 Applianoeslother 1700 0 Subtotal (lines 6 to 13) 15406 13810 2183 2100 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 15406 0 0 13810 0 0 2183 0 0 2100 15 D6dloads 17% 201/6 2627 2813 17%1 209/6 372 428 Total room load M, required (cfm) 18032 7731 16623 7731 2556 110 2528 118 ACCAto meet all requirements of Manual J 8th Ed. Right-SdteOUniversal 201818.0.31 RSU76877 . C�A ...\Desktop\TEMPPRINT\Lot026F1452ARHG-W.rup Calc=MJ8 Frond Door faces: W 2018-Oct-0216:3127 Pagel -�- wrightsoft`° Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sal stove Cart, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: m wuOneStopCooling.com License: CAC032444 Job: Lot 026 F1452 A RHG - W Date: 06/06/2018 By. RI/MC 1 Rm name oo GREAT WED 2 osed wall 14.0 It 30.0 ft 3 1oomheight 8.7 ft heaUmol 8.7 ft heaUmcl 4 Room dimensions 1.0 x 298.0 ft 1.0 x 227.0 ft 5 Room area 298.0 ft2 227.0 >tz 7y Construction U-value or HTM Area Load Area UP) Load number (BtuhM-09 (Btuh/ft9) or perimeter (it) (Bh1h) or perimeter (ft) (Btuh) Heat Cool Gross NOS Heat Cool Gross N/P/S Heat Cool _ -- - ---- 6 13A-4ois 0.143 n 3.72 2.62 0 0 0 0 0 0 0 0 4A5,2om. 0540 ..n . -14.04 ...14.36 -., __. --0 ---- -.0 9. 0 .. _ ..0':__ W I 13A-4ocs 0.143 a 3.72 2.62 122 89 331 233 131 114 424. 299 4A5-2om 0.540 a 14.04 34.14 33 0 459 1116 16 0 229 558 LLL __ G�G__GG; 11 4A5.2omd 0.630 a 16_38 42.09 0 0 0 0 W 13A flocs -' 0.143 s 3.72 2.62 -_ 0 -- -- 0 ----- 0 --- 0 - --. -0 131 •-- 114 - .__.0 424 _ 299 � 4A5.2om: _ 0;540 s 14.04 . -- 14.36 _0 -_ . _ _ _0 _ .16 - .._16 - - -- - 229 _ 235 ,'... -_G_ L13A-flocs 0.143 w 3.72 2.62 0 0 0 0 0 0 0 0 4A5-2om 0.540 w 14.04 34.14 0 0 0 0 0 0 0 0 11 DO 0.390 w 10.14 11.50 0 0 0 0 0 0 0 0 R ! 12C Osw -- 0091 - _ 237 1.33 - 0 0 0 - 0 0 0 6 -0 -11D0_ ...-.._ .. .. _ ..... 0390 _n 10.14 11.50 ,.. _ _ -... 0 . .._- _ 0 _ 0 - _ -_ _� _ _ 0 D C 16B-30ad 0.032 0.83 1.70 298 298 248 565 227 227 164 385 F 22A tpm .1 180 . T 30 68 0 00 298 �14 430 0 227 30 920 0 6 c) AED excursion 196 -118 Envelope loss/gain 1468 2051 2417 1657 12 a)! Infiltration 260 92 557 197 b) Room ventilation 0 0 0 0 13 Internal gains: Cocupants@ 230 0 0 2 460 Applianoestother 0 0 Subtotal (lines 6 to 13) 1727 2143 2974 2314 Less extemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 200 320 0 0 14 Subtotal 1927 2463 2974 2314 15 Ductloads 17% 20% 329 502 17% 20% 507 471 Total room load 2256 2964 3481 2785 Air required (dm) 97 138 149 130 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. `� -�.r- wrightsoft� Right-StDte®Uriversa1201818.0.31 RSU16877 2018-Oct-0216:31:37Paget .\Desktop\TEMPPRINT\Lot026F1452ARHG-W.np CaIc=MJB FroMDoorfaces: W -�- wrightsofr Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sandswve Coin, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCoolirig.com License: CAC032444 Job: Lot 026 F1452 A RHG - W Date: 06/06/2018 By. RI/MC 1 �oomname Kff PAN 2 xposedveall 9.0 ft 4.0 ft 3 oom height 8.7 ft heaUoocl 8.7 It heaU000l 4 oom dimensions 1.0 x 126.1 ft 1.0 x 16.9 ft 5 oom area 126.1 ftz 16.9 t6 y Construdion number U-value (Btuh4F--n Or HTM (BtuhV) Area (ft2) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N4'/S Heat Cool Gross M S Heat Cool 6 �Ij1i t--(' 13A-flocs .4A5-2om.. 13A-flocs - - 0.143 OS40 0.143 n n _ a - 3.72 14.04 3.72 2.62 14,36 2.62 78 :- .0 0 - 78 -0 0 291 .-. 0 0 ' _ _.. 205 0 0 _ .._ . _ 35 0 0 - - 35 0 0 129 --0 0 - 91 _ -_0 0 I 11 4A5-2om 4A5-2omd 13A flocs - 0.540 0.630 0143 e a s 14.04 16.38 3.72 34.14 42.09 2.62. 0 0 0 0 0 0 0 0 •0 0 0 0 0 0 0 0 0 _,- _0 0 0 _ 0 0 0 0 W 540 _s... 14.04:... 14,36 . - . 0 . _ .. 0. .. .. -Q _ .- 0 . ' V�1 13A-4ocs _0 0.143 w 3.72 2.62 0 0 0 0 0 0 0 0 4A5-20m 11DO 0.540 0.390 w w 14.04 10.14 34A4 11.50 0 0 0 0 0 0 0 _._ _ 0 0 ._ _._ _.. 0 0 .___... 0 0 ..__.__-...0 0 _.. 0 .. a _ D .0.390 � n _ 10.83 . .0 .. 0_..0. C 11 d 0.032 1 180 _ - 30.68 _11.50 . 0.00 126 , 126 126 .. ` 9 105 .276 214 , _---0 17 17 17 .. 4 14 - 123 _29 . _ ...0 6 c) AED excursion -81 -7 Envelope lossrgain 672 337 266 113 12 a) Infiltration 167 59 74 26 b) Room ventilation 0 0 0 0 13 Internal gains: Ocaipants@ 230 0 0 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13) 839 1596 340 139 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 3 842 0 6 1602 0 0 340 0 0 139 151 Dudloads 171/. 20% 144 326 17% 209/. 58 28 Total room load 986 1929 398 167 Airrequired(dm) 42 90 17 8 -*- wrightsoTt� Right-Sdte®Universal 201818.0.31 RSU16877 \Desldop\TEMPPRIM1Lot026F1452ARHG-W.rtp. CaIc=MJ8 From Door faces: W 2018-Oct-0216:31:37 Page 3 - -wrightsoft Right-JOWorks feet Job: Lot 026 F1452 ARHG -W Entire House Date: 06/06/2018 By. RI/MC • One Stop Cooling and Heating 7225 San stove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCocling.com License: CAC032444 1 1oom name MWIC METH 2 osed wall 0 ft 12.0 ft 3 oom height 8.7 ft heaUocol 8.7 ft heatIcool 4 oom dimensions 8.0 x 7.0 ft 1.0 x 107L ft 5 area 56.0 ftz 107.5 ffz loom T Construction U-value Or HTM Area (22) Load Area (ftl Load number (Btuh/fR-on (Btuh/*) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPS Heat cool Gross N/P/S Heat Cool 6 V�1 L-__-G 13Aflocs _ -4A52om.- _ 0143 ,' :05d0 n. n-- 372 14.64 2.62 - 14.36 - - 0 0 0 .__._. 0 __ : _0 _....a_._.0 .- _ 0 _ 0 .. -0 0 --- - •,-0 0 0 �j I1-C'' 13A-4ocs 0.143 a 3.72 2.62 0 0 0 0 0 0 0 0 4A5-2om 0.540 e 14.04 34.14 0 0 0 0 0 0 0 0 �-- G 11 4A5-2omd 13A-4ocs - 0.630 n43 a s, 16.38 3.72 42.09 2.62 0 ., 0 0 0 0 - 0 0 - 0 0_ 104 0 104 _ 0 388 0 273 V , _L-G..._ . 4A5-tom - 13A-4ocs _. 0540.. 0.143 s w 14.04 3.72 14.36 2.62 _. "- 0 0 _ _._:.. 0 0 _-o 0 _. _ 0 0 _ _.. 0 0 __ -- 0 0 _ 0. F 0 - 0 0 L-D 4A5-2om 11D0 0.540 0.390 w w 14.04 10.14 34.14 11b0 0 0 0 0 0 0 0 0 0 0 ,I C 12C Osw __ 16B-30ad 0091 .0390 0.032 = _ n_ 2.37 10.14 0.83 1.33 11..50 1.70 - 70 0 56 _ 70 ... 0-_---- 56 --- --- -� ' 165 _.-0 47 --.___..__0 92 _ -_ -.-0 95 _. _ .--0. 65 _. ._0. 108 ._ _0 65 _ _- U 108 _-.__ ..---0 154 ,. _.0 89 Y 87 182 1,180 -.. 30.68. 0.00 . _. 56 0 .. 0 0 , . 108 _ . 12 366 0 _ 6 c) �AED exarsion -9 -30 Envelope loss/gain 211 178 1000 512 12 a) Infiltration 0 0 223 79 b) Room ventilation 0 01 6 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 211 178 1223 591 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 62 369 0 0 14 Subtotal 273 548 1223 591 15 Dt dloads 179% 20% 47 112 17% 201/o 208 120 Total room load Aii required (dm) 319 14 659 31 1431 61 711 33 Calculations approved byACCAto meet -1'I.F- wrYghtsoTt- 2018-Oct-0216.31 A7 Right-Srnte®Uriversal201818.0.31 RSU16877 Page \Desktop\TEMPPRINT\Lot026F1452ARHG-W.rLp Calc=MJ8 Frond Door faces: W -�- wrightsoft' Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwmOneStopCooling.00m License: CAC032444 Job: Lot 026 F1452 A RHG - W Date: 06/06/2018 By: RI/MC 1 i Room name BTH2 2 Vosed wall Oft O ft 3 koom height 8.7 it heat/cool 8.7 ft heaU000l 4 woom dimensions �Ioom 5.5 x 4.0 It 5.5 x 8.5 ft 5 area 22.0 fF 46.8 it2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhfil�--F) (Btuh/ft2) or perimeter (it) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 4gcs ----- -;0,143 n 3. 2 ' 2.82 " - - - - -'-CI -_0 - - - - 0 Q - - -0 - - 0 - b ,¢A5.2om _ _' • ... 0 540 n _ .. 14.04 .14.36 ; _ . _ _ 0 _ 0 0 _ a 0 0 0 VIIiI--� 13A-4o s 0.143 a 3.72 2.62 0 0 0 0 0 0 0 0 4A5-2cm 0.540 a 14.04 34.14 0 0 0 0 0 0 0 0 �--G 11 4A5-2omd 0.630 a 16.38 42.09 0 0 0 0 0 0 0 0 V+Ji 13A flocs ., 0143 s 3.72 2 62, 0 - 0 - 0- 0 0 0 0 0 4A52om_... 0540 ._s.. '14.04 _ .1436 -_ ... 0'.., .: 0 R _ Q .. _0 ,0 _0.. _. _. 0 y/ 13A-4as 0.143 w 3.72 2.62 0 0 0 0 0 0 0 0 4A5-2om 0.540 w 14.04 34.14 0 0 0 0 0 0 0 0 —G D 11 DO 0.390 w 10.14 11.50 0 0 0 0 0 0 0 0 R 12C-0sw 0 091 - 2 37 .1.33 0 6 -- - 6 - 0 0 d- 6 _. ... _'0.032 0.390 n _ _ 10.14 _ 11. .`. ... _ 0 _ _. 0 - 0 0 ... -0 _ .. 0 _ _. ._... 0 C i... -- _ ,.._ 16B 30ad 0.83 0 20 2 _ _ 22 18 37 47 . _ _ 47 - 39 79 E . - -- --- - -- - --- — - 22 - - -0 - - - - 0 - - .. 0 _ - - . __- 47 ._ 0 - 0 -_ - 0 - 6 c)'AEDexcursion -2 -4 Envelope losstgain 18 36 - 39 75 12 a) Infiltration 0 0 0 0 b), Room ventilation 0 0 0 0 13 Internal gains: Ooalpants@ 230 0 0 0 0 Appliances/other 7 0 0 Subtotal (lines 6 to 13) 18 36 39 75 Le'.load external Lesstransfer 0 0 0 0 0 0 0 0 Redistribution -18 -36 511 394 14 Subtotal 0 0 550 469 15 Dbct loads 170/6 20% 0 0 17% 20/ 94 96 Total room load 0 0 644 565 Air required (dm) 0 0 28 26 to meet all requirements of Manual J -o&- wa,; !q 2018-Oct-0216:3127 Right -Suite® Universal 2018 18.0.31 RSU16877 Page 1Desktop\TEMPPRIMRLot026F1452ARHG-W.np Calc=MJ8 Front Door faces: W - wrightsoft- Right-M Worksheet Entire House One Stop Cooling and Heating 7225 Saidscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.cwm License: CAG032444 Job: Lot 026 F1452 ARHG - W Date: 06/06/2018 By: RI/MC 1 2 Boom name �osed wall LDRY - 0 ft BED3 14.0 ft 3 Boom height 8.7 ft heaU000l 8.7 It heaUcool 4 oom dimensions 3.5 x 7.0 it 11.0 x 14.0 it 5 oom area 24.5 ft2 154.0 ftz y Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (Btuhtft2--q (BtuW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 v(r�j ' ; 1-4ois '4A5 3A tom _ _ --0.143 OS40 -n . n - 3.72 _ . 14.04 -- 2.62 14.36 __.._ O _ .0 .-- 0 _ . - 0 --- 6 0 - 0 0 - 122 _ . 16 j05 _ 0 - -- 392 . 229 - 278 _ _ 235. 13A-4ocs 0.143 a 3.72 2.62 0 0 0 0 0 0 0 0 4A5-2cm 0S40 e 14.04 34.14 0 0 0 0 0 0 0 0 11 4A5-2cmd 13A 4acs 0.630 0143 _ e s, 16.38 372 42.09 2 62 0 0 0 "0- 0 0 0 - 0 0 - 0 0 0 0 - 0 0 - 0 W L 4A5 tom, . _. _ _ _ _._ __ . _ _0 540 -s .: _ 14.04 {L--G —G' _ 13A-4ocs 0.143 w 3.72 2.62 0 0 0 0 0 0 0 0 4A5-2om 0.540 w 14.04 34A4 0 0 0 0 0 0 0 0 R { D 11 DO 12G Osv: - 0.390 - 0091 w 10.14 237 11.50 0 0 0 0 0 0 0 0 -11D0 _0390 n.. 1014 11SO - .__0 ._, --0 0 _ 0 „0 0 0 0. 7-7D C i 16B-30ad 0.032 0 83 170 25 25 20 42 154 154 128 261 F I 22A m V?_.1.180 . -._ 30.68 .' -0.00 � . 25 - .. 0 - _ 0 . _ _ _ 0 -- - _ . � 154 14 430 -0 6 c) AED excursion -28 -53 Envelope loss/gain 92 54 1179 719 12 a) Infiltration 0 0 260 92 b) Room ventilation 0 0 0 0 13 Iritemal gains: Occupants @ 230 0 0 1 230 Appliancestother 500 0 Subtotal (lines 6 to 13) 92 554 1439 1041 Less extemal load L6sstransfer 0 0 0 0 0 0 0 0 Redistribution -92 -554 146 112 14 15 Subtotal Dud loads 17% 20% 0 0 0 0 17% 20% 1585 270 1153 235 Total room load 0 0 1855 1388 Airrequired (dm) 0 0 80 65 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -� F?- wr7gFitsoft® 2018-Oct-0216:3127 Right-SLiteDUriversal20l8l8.0.31 RSU16877 Page ...\Desktop\TEMPPRINT\Lot026F1452ARHG-W.np Calc=MJ8 Front Door faces: W - Wrightsofr Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sa idscove Court, W irfter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wmuOneStopCoolirg.com License: CAC032444 Job: Lot 026 F1452 A RHG - W Date: 06/06/2018 By: RI/MC 1 2 3 4 5I Room F Room name 4osed mall oom height dimensions oom area BED2 37.0 ft 8.7 ft heaUcool 15.5 x 11.0 ft 170.5 ftz FOY 5.5 ft 8.7 ft heaU000l 1.0 x 99.0 ft 99.0 ft2 Ty Construction U-value Or HTM Area (T) Load Area (ft2) Load number (Btuh4IFLIn (Btuh4t�) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/RS Heat Cool Gross N/P/S Heat Cool - 6 yJ 13A-46 _ 4A5:2om - , 0143 0 540 --6- _' n - - 3.72 14.04 262 .. _ 14.36 96 .0 --96 _ 0 - M6 '__"0 250 _ -- 0 , ._ a _ -- 0 ._. a -_ _ _ -0 -- -- O -- 0 13A-4ocs 0.143 a 3.72 2.62 0 0 0 0 0 0 0 0 4A5-2cm OS40 e 14.04 34.14 0 0 0 0 0 0 0 0 11 4A5-2omd 13A 4dc§ • . 0.630 - 0143 a s 16.38 3 72 42.09 0 91 0 91 0 340 0 23,q 0 0 0 _ _ - 0 0 - 0 0 %- 0 yJl 2.62 (i 4A5-2om�-- 13A-4ocs 0540 0.143 ._s -- w ---- -. 1404 3.72 - _. 14.36 2.62 _ . . _._ 0 135 0 119 ' .__.._0 441 _ _ .. ____0 310 _ _ 0 . 48 __.'.__0 28 . _ _ ._0 103 73 -I-'- 4A5-20m 11 D0 12G Osw 0.540 0.390 0 091 w w - 14.04 10.14 2.37 34.14 11.50 1:33 16 0 b 0 0 0 229 0 -- 0 558 0 0 0 20 87 0 _ _ 20 71 0 _ - : 204 168 0 _ 231 R j '' : 11D0___....._,..` .. _.0390 . n_ 10.14 1150 .. _ -.-_0 . _-- _ Q ',._0 .__,. .._-0 '.:_ ....16 . _ _ 16 _ C 168 30ad 0.032 0.83 1.70 171 171 142 289 99 99 82 168 F I. - OAtpm ... 1.180 _. _: 30.68 ... 0.00 171. __ 37 _ -- 1135 _.. -- - -- - _ __0 -- - - -- 9-9 _ 6 _. _ _--_i69 . _ .0 6 c) AED excursion 175 -38 Envelope lossrgain 2643 1822 888 712. 12 a) Infiltration 686 243 102 36 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3329 2294 090 748 Lessextemalload 0 0 0 0 14 15 Lesstransfer Redistribution Siubtotal Dudloads 171/6 20%1 0 180 3509 598 0 136 2430 495 179/6 209/. 0 -990 0 0 0 -748 0 0 Total room load 4107 2926 0 0 Air required (dm) 1761 136 0 0 ACCAto meet all requirements of Manual J 8th Ed. wr�gt�tisoYl� Right-Suite@Uriversal201818.0.31 RSU16877 \Desktop\TEMP PRINT\Lot 026 F1452 A RHG - W.np Calc= MJ8 Front Door faces: W 2018-Oct-0216:31:37 Page 7 - - Wrightsoft" Duct System Summary Entire House One Stop Cooling and Heating • 7225 Sandscove Cout, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ww,uOneStopCooling.com License: CAC032444 For: Ryan Homes Ft. Pierce, FL Job: Lot 026 F1452 A RHG - W Date: 06/06/2018 By. RI/MC i Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.16 in H2O 0.16 in H2O Available static pressure 0.34 in H2O 0.34 in H2O Supply / return available pressure 0.170 / 0.170 in H2O 0.170 / 0.170 in H2O Lowest friction rate 0.253 in/100ft 0.253 in/100ft Actual 'air flow 773 cfm 773 cfm Total effective length (fEL) 134 ft Supply Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk 13ED2I h 4107 176 0.269 7.0 Ox0 MFx 21.5 105.0 st2 BEDS h 1855 80 .136 65 0.310 6.0 Ox 0 VIFx 14.7 95.0 st2 8TH2 h 644 28 26 0.298 4.0 Ox 0 VI Fx 14.1 100.0 st2 DIN c 2528 110 118 0.274 6.0 Ox0 VIFx 29.1 95.0 sti GREAT c 1482 48 69 0.299 5.0 Ox0 VIFx 18.7 95.0 sti GREATA c 1482 48 69 0.306 5.0 Ox0 VIFx 16.3 95.0 sti KIT c 1929 42 90 0.271 5.0 Ox 0 VIFx 25.5 100.0 sti MBED ! h 3481 149 130 0.276 6.0 Ox 0 VIFx 23.3 100.0 sti MBTH h 1431 61 33 0.271 4.0 Ox 0 VIFx 25.7 100.0 sti MWIC c 659 14 31 0.253 4.0 Ox0 VIFx 24.3 110.0 sti PAN h 398 17 8 0.272 4.0 Ox 0 VI Fx 25.0 100.0 st2 Trunk Htg Clg Design Veloc Diam H x W . Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk sti PeakAVF 473 538 0.253 685 12.0 0 x 0 VinlFlx st2 PeakAVF 300 235 0.269 680 9.0 0 x 0 VinlFlx - wrightsoft® 2018-Oct-0216:3128 �- pean.HlBaM�ueww-ry Ump.,y Right-SLite®Uiiversal2018 18.0.31 RSU16877 Page 1 A, ...\Desktop\TEMP PRINTLot026 F1452A RHG - W.rtp Calc= MJ8 Front Door faces: W Return Branch Detail Table NamlGrille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mal Trunk rbi Ox 0 773 773 0 0 0 0 Ox 0 VIFx �. wrightsoft'- .N/Bch+Linl4ilvmry2mpvry Right-Sate®Uriversal201818.0.31 RSU16877 ...\Desldop\TEMPPRINM.1026F1452ARHG W.np Calc=MJ8 FrordDoorfaces: W I 2016-Oct-02162138 Page 2 - wrightsoft® Static Pressure and Friction Rate Entire House One Stop Cooling and.Heating 7225 Sar4scove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.00m License: CAC032444 For: Ryan Homes Ft. Pierce, FL Job: Lot 026 F1452 A RHG - W Date: 06/06/2018 By. RI/MC neazmg L oonng (in H2O) (in H2O) External static pressure 0.50 0.50 Pressurelosses Coil 0 0 Heat exchanger 0 0 i Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total• Supply Return (ft) (ft) Measured length of run -out 12 0 Measured length of trunk 12 0 Equivalent length of fittings 110 0 Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.253 > 0.18 0.253 > 0.18 Return Ducts 0.253 > 0.18 0.253 > 0.18 Fitting Equivalent LengthDetails 4X--35,11 A=20,11 G=5,11 G=5,11 G=5,1 A=35,11 G=5: Total EL=110 Return TotalEL=O -*- wrightsoft® 2018-Oct-02 16:3128 A_, Right-SUteGUniversa120i818.0.31RSU16877 Pagel AC...\Desktop\TEMP PRINT\Lot 026 F1452 A RHG - W.rnQ Calc= MJ8 Front Door faces: W tl-i = 5u ui-w ran EF2 = 80 CFM Fan EF3 =110 CFM Fan EFL1 = 50 CFM Fan EFL2 = 80 CFM Fan EFL3 =110 CFM Fan VTR = Vent to Roof VTW = Vent to Wall DV = Dryer Vent RV = Range Vent = Lineset Chase — — = Condensate — - — = Thermostat 18/8 O SRB = Small Reduction Box LRB = Large Reduction Box FBB = Reld Built Box #: Lot 026 F1462 A RHG - W Performer) by. RUMC for: Ryan Homes Ft. Pierce, FL Level 1 AC PADS BYGC MIN SIZE 40"X40" 36" SEPARATION 16" OFF WALL PVC REFRIG LINE CHASES BY GC One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 www.OneStopCooling.com Scale:1 : 98 Pagel Right Suite® Universal 2018 18.0.19 RSU16202 2018- Jul-2716:1721