HomeMy WebLinkAboutFIELD LAB REPORTU N I S A L
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 : P: 321.638.0808 - F: 321.638.0978
/pit _639!5-
Aok, , lo.: 0310.1700251.0034
ped: January 02, 2019
FILREIV,.DCOPY
FES 21 2918
Perm ittip$ ®A, ....
Construction Mat&Ws Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client: Ryan HomesSCANNED
1450 Centrepark Blvd Suite 340 BY
West Palm Beach, FL 33401 St Lucie County
Project: Oakland Lake Subdivision Lot 26_
5278 Oakland Lake Circlet�ermi__ t No 18 , -0L 85�ort Pierce, St. Lucie County, FL
As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or
field inspection services on the above project. -Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No. Date Type of Report
104852-1 I 12/28/2018 In -Place Density Test Report w/Activity Record
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
Sincerely,
Universal En neviing Sciences, Inc.
Certificate'Ff A6ifi6rization..No,-00000549
i •
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has been electronically signed and sealed by
Richard E. Hoaglin, P.E. using a Digital. Signature. Printed
copies of this document are not considered signed and
sealed and the signature must be verified on any electronic
copies.
ICC Email: cbugb@nvrinc.com; elibrihi@nvrinc.com; Imhoff, Bryan [BIMHOFF@nvrinc.com]; jomcalli@nvrinc.com; rofingar@nvrinc.com; sign/seal MAIL to
ryan homes at 1777 Willows Square, Vero Beach, FL 32966
717f,"A
UES roje lo: 0310.1700251.0034
U'
UEWC! '�J IV - LUES epor< no: 104852-1 ARC 122818
ENGINEERING SCIENCES On -Site Time (hrs): 1.00
Consultants In: Geotechnical Engineering'- Environmental Sciences Lab Time (hrs): 0.00
Geophysical Services • Materials Testing oThteshold,lnspection Travel Time (hrs): 0.50
Buildog-CbdeA-dministration; Compliance Inspection & P%n Review Total Time (hrs): 1.50
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project; Oakland Lake Subdivision Lot 26
5278 Oakland Lake Circle Permit No 1810-0385, Fort Pierce, St. Lucie County, FL
Date of Activity: Friday, 28 December, 2018
Technician: Cliff Cherrnay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
i
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House
pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
r
U NIV`mISAL
ENGINEERING SCIENCES
Consultants In: G"eotechnical Engineering • Environmental Sciences
Geophysical Services • Mater'ials Testingi Threshol'Onspection
Building, Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Client:
Project:,
I
Area Tested:
Type of lest:
Technician:
Requirements:
In -Place Density Test Report
R, A No: 0310.1700251.0034
D -i No:
UES Report No: 104852-1 DT 122818
Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Oakland Lake Subdivision Lot 26
5278 Oakland Lake Circle Permit No 1810-0385, Fort Pierce, St. Lucie County, FL
House pad
Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 12/28/2018
Lab: ASTM D1557 Modified Proctor
Cliff Cherrnay
95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlying soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
N/W test
0-1 ft
12.00
21180
111.1
12.3
99
A
2
N/E test
0-1 ft
12.00
21180
111.7
12.0
100
A
3
S/E,test
0-1 ft
12.00
21180
109.1
11.8
97
A
4
IStest
0-1 ft
12.00
21180
110.0
11.5
98
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
1 #
Density
Content
121180
112.0
11.0
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
I
This reportshall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance inspection & Plan Review
82D Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
As r
field
UES Project No.: 0310.1700251.0034
Date Typed: January 02, 2019
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Ryan Homes SCANNED
1450 Centrepark Blvd Suite 340 BY
West Palm Beach, FL 33401 , St Lucie County
Oakland Lake Subdivision Lot 26
5278 Oakland Lake Circle Permit No 1 rt Pierce, St. Lucie County, FL
Wed, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials testing and/or
)ection services on the above project. Testing results and/or inspection observations are reported on the attached
The contents of this package are summarized below:
Scope of Work
Work Order No. I Date Type of Report
1 104852-1 1 12/28/2018 1 In -Place Density Test Report w/Activity Record
We
the i
ICC I
ryan
this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
signed.
'`y�fl�i
ti C� •' Vic. elms•.r0
= NO.48?98
r • �
■, STATE OF •
,{�, .•
=�4C7i�il�� : •' •����
�,rl�?'Nf i>>�'�', .
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 00000549
Richard E.
Hoaglin, -P.E.
2019.01.03
1.5:15:09
-05'00'
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has been electronically signed and sealed by
Richard E. Noagiln, P.F- using a Digital Signature. Printed
copies of this document are not considered signed and
sealed and the signature must be verirred on any electronic
copies.
cbugg@nvrinc.com; ellbdhl@nvrinc.com; Imhoff, Bryan IBIMHOFF@nvrinc.com]; jomcalll@nvrinc.com; rofingar@nvdnacom; sign/seal MAIL to
; at 1777 Wcilows Square, Vero Beach, FL 32966
RECEIVED
tarts 0 7 2019
Permitting Department
St. Lucie County, FL
UNIVERSAL UES Project No: 0310.1700251.0034
UES DOCS No:
UES Report No: 104852-1 ARC 122818
ENGINEERING SCIENCES On -Site Time (hrs):1.00
Consultants In: Geotechnical Engineering a Environmental Sciences Lab Time (hrs): 0.00
Geophysical Services • Materials Testing • Threshold Inspection Travel Time (hrs): 0.50
Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 1.50
Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activijy Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 26
5278 Oakland Lake Circle Permit No 1810-0385, Fort Pierce, St. Lucie County, FL
Date of Activity: Friday, 28 December, 2018
Technician: Cliff Cherrnay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad,
on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House
All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
ct compaction requirements of 95% of the maximum dry density per ASTM D-1657.
The Contractor was notified of the test results or a copy was left for their records.
0310.1700251.0034
UNIVERSAL
UUES ES DOCS Noo:
ENGINEERING SCIENCES UES Report No: 104852-1 DT122818
Consultants In: Geotechnical Engineering - Environmental Sciences
Geophysical Services - Materials Testing - Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL. 32955 - P: 321.638.0808 - F: 321.638.0978
!
In -Place Density Test Report
Client:
Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project:
Oakland Lake Subdivision Lot 26
5278 Oakland Lake Circle Permit No 1810-0385, Fort Pierce, St. Lucie County, FL
Area Tested:
House pad
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 12/28/2018
Lab: ASTM D1557 Modified Proctor
Technician:
Cliff Cherrnay
Requirements:
q
95% of Proctor maximum d density.These tests apply to the fill and/or surficial soil conditions
conditi soils
only and do not address the of the underlvinq below the tested depths.
j
Test
' No:
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
C-map 9tion
Comments
(3)
1
NM test
0-1 ft
12.00
21180
111.1
12.3
—99
A
2
WE test
0-1 ft
12.00
21180
111.7
12.0
100
A
3
WE test
0-1 ft
12.00
21180
109.1
11.8
97
A
4 '
SMI test
0-1 ft
1 12.00
1 21180
1 110.0
1 11.5
1 98
A
(1); Ref. Datum: 0 = Top of Final Grade
(2)'
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
21180
112.0
11.0
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not be reproduced, except in full, without the wrftten approval of Universal Engineering Sciences.