Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LETTER - HIGH WIND RESISTANT CONSTRUCTION CERTIFICATE
K PRINCIPAL Engineering 1011 N Causeway Blvd, Suite 19 ♦ Mandeville, Louisiana 70471 ♦ Phone: 985,624.5001 ♦ Fax: 985.624.5303 October 2018 RECEIVED St. Lucie County, FL NOV St. 0 2018 Property Owner: Charles Rowe I I ST. Property Address: 7901 Santa Clara Blvd., St. Lucie, Florida 34951 Re: HIGH WIND -RESISTANT CONSTRUCTION CERTIFICATE SCANNED StLucie County Wind loads have been calculated for a speed of 157 MPH. The roof pitch and construction have been analyzed, and the photovoltaic system structure designed to resist resulting uplift and downward forces. The attached drawings and diagrams reflect a design that safely transmits dead and live loads to the roof. To the best of my professional knowledge and belief, the subject construction and photovoltaic system installation will be in compliance and designed to 2017 Florida Building Code 6th Edition at the time of our review. i '0 ST.LUCIE COUNTY REVIEW, PLAN BLDG: ELEC:_-__ DATE` PLUMB: DATE;,�,,.�_. MECK�— DATE: .X I /I!'f,�J�-''� i `d �f �� IJ �Fl,,�.� c� i %FJ��•J.....1 2, PRINCIPAL InfrastructureT M Architecture ♦ Engineering ♦ Construction 1�,1111118181i 41 +* No.71950 wo �C rx W STATE OF �I� w Firm No. 30649 Principal Engineering, Inc. www.pi:aec.com ♦ info@pi-aec.com Uplift and Wind Downforce Calculation Summary (ASCE 7-05 Method 1) Mount. Rack. & Panel Pronortionin>± Property Owner: Charles Rowe Individual Panel Dimensions Project Address: 7901 Santa Clara Blvd. Length (in)l Width'(in) Area (sf) City, State: St. Lucie, Florida 34951 77 39 20.85 Building Characteristics, Design Input, and Adjustment,Factors Basic Wind Speed: Exposure Category: Occupancy Category: Effective Wind Area (sf): Roof Dimensions: Length: Width: Lf Height (h): Pitch: 2joh 12 = Ht. & Exposure lustment (A) Iportance Factor (1) ml TO Adj. (K,.t) 157 From Code Office or Fig. 6-1 Para 6.5.6.3 Table.1-1 Para 6.2 (Area per individual fastener) 'Least Dimension: 5.5 Fig 6-3, Note 5, must be less than 60 degrees; must be less than 45 Fig. 6-3 Table 6-1 Para 6.5.7 B 2 10 60 55 24 26.6 1 1 1 . i Roof Zone Strip (a), in ft, Fig. 6-3, Note 5 1' Least Roof Horizontal Dimension (L or W) X 0.10 2 Roof Height x 0.4 3 ! Least Roof Horizontal'Dimension (L or W) x 0.04 4 Least of (1) and (2) 5 - Greater of (3) and (4) 6 - Greater of (5) and.3 feet a= 0.55 9.6 0.22 5.5 5.5 5.5 ,p�9!l1111��,0 CD 4% s • * No. 71950 D: = Oft�+ STATE OF Ar 10 �& ORIoP to I r 0 (� �-3L9 �� Net Design Pressures (Fig 6-3), Components & Cladding Uplift (-psf) Down (psf) 30net zt 30net 30net zt 30net Zone 1 40.7 40.7 25.6 25.6 Interior Roof Area Zone 2 70.9 70.9 25.6 25.6 Strip of (a) ft wide at root edge Zone 3 104.9 104.9 25.6 25.6 Corner intersection of strips Mount & Rail Selection . Manufacturer: Nucor Perpindicu/ar Panel Orientation Model: Allowable Scheme by Uplift Pressure S-5-U Mini Ultimate Uplift (lb): < 60 psf 2 rails, 4"-0" OC mounts 60-90 psf 3 rails, 4'-0"; or 2 rails, 2'-0" 90-110 psf 4 rails, 4%0" OC mounts 1913 Parallel: Mounts per Individual Panel # Mounts FS Zone 1 1.5 3.4 110-150 psf 3 rails, 2'-0" OC mounts Zone 2 3.3 4.3 150-170 psf4 rails, 2'-0" OC mounts Zone 3 3.3 2.9 1170 psf +, panel clip capacity exceeded (From, rail analysis, allowable pressures controlled by individual mount pullout before rail bending) Firm No. 30649 Principal Engineering, Inc. THIS EDGE TOWARDS ROOF RIDGE 'he engineer's seal and signature n this manufacturer's drawing cc ie product for use in this project 4.50 W IX of2.00 397 0.3.30 1.00 .040 1.77 ITEM DESCRIPTION QTY. NO. 1 FLASHING, ROUNDED _CORNERS,__9"X_L2"-X-.040"-5052-MILL----1- 2 L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 6061-T6/6005A-T61, MILL 1 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 L-FOOT 2" X 3.30", 2 X .75" SLOT FOR .438" O.D. FASTENER, 6061- 1 T6/6005A-T61. MILL I O,',Oifi7l/gd,d 1200. No.71950 3.00 (4 120 p STATE OF 4r� 4 3 ' str,` �C O R\9�' 2 QMLM2: 2 X .75" SLOT VERSION * OPTIONAL o 2.00 0.397 TYP 1.00 Al f 1 irm No. 30649 3.30 Principal Engineering, Inc .75 0_ AVAILABLE IN MILL, AND BLACK FINISHES .25 1.14 .751 Quick Mount PVu TITLE: (2.50) (3.54) QMLM2 5/16" LAG, 9" Charles Rowe QMLM: L-MOUNT, i X 12" FLASHING QMLM 7901 Santa Clara Blvd. UNLESS OTHERWISE SPECIFIED: SIZE A I DRAWN BY: RAD REV 6 St. Lucie, Florida 349511 DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL± 1 /8 TWO PLACE DECIMAL ±.19 THREE PLACE DECIMAL ±.094 DATE: 8/23/2017 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAW ING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE DO NOT SCALE DRAWING WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT ® 2016 QUICK MOUNT PV SCALE: 1:4 WEIGHT:1.0241 SHEEP 1 OF 1 5 4 3 2 1 ,l Address: following components installed per the attached diagrams and plans will comply with the required mph ultimate wind loads in attached plans labeled as follows; Quick Mount PV, L-Foot Layout, Rail Layout, Solar array Layout. le Compliant Unirac Solar Installation Components. iirac SolarMount Rail Components The engineer's seal and signature on this manufacturer's drawing certifies the product for use in this project only. i ORail — Supports PV modules. Use two per row of I Aluminum extrusion, anodized. © Rail splice —Joins and aligns rail sections into single length of rail. It can form either a rigid or thermal expansion joint, 8 inches long, predrilled. Aluminum extrusion, anodized. © Self -drilling screw — (No. 10 x 3/a") — Use 4 per rigid splice or 2 per expansion joint. Galvanized steel: O L-foot — Use to secure rails either through roofing ii material to building structure or standoffs. Refer to loading tables for spacing. Note: Please contact Unirac forl use and specification of double L -foot. © L-foot bolt (3/8" x 3/a") — Use one per L-foot to secure raillto L-foot. Stainless steel. OFlange nut (3/8") — Use one per L-foot to secure rail to L-foot. Stainless steel. 1, ,11111111t,•11�� `; plFfiRq��; .�J :�o��� vOGENsF ®�� No. 71950 X � w- G STATE OF 10 �10 ,S' 1 01 44*1 /2 —30 Figure 4. SolarMount standard rail components. lock washer for attaching L foot. Flashings: Use one per standoff. Unirac offers appropriate flashings for both standoff types. OLag screw for L-foot (5/ 16") — Attaches standoff to rafter. See PV Quickmount Notes below. (i Top Mounting Clamps • Top Mounting Grounding Clips and Lugs ADDITONAL NOTES: • PVQUICKMOUNT—Attaches L-foot or standoff to rafter. install per attached Quickmount PV detail; QMSC: Classic composition mount dated 7/19/2012. If lag screw head is exposed to elements, use stainless steel. Under flashings, zinc plated hardware is adequate. Waterproof rooting sealant — Use a sealant appropriate to your roofing material. Consult with the company currently providing warranty of roofing. 611 Firm -No. 30649 Principal Engineering, Inc. DocuSign Envelope ID:'28751338'4B70-4541-B71A-73A484A8AF613 SUNPRO INSTALLATION MAP Rowe, Charles ( 22 ) SiLfab 30OW ( 22 ) ENPHASE IQ7 Fst mated: Energy's vings krsnual }2eslitrs 1,0;470.kWh per. Year' Low. -F(igh: Esill-nai'ecl Solar Ehergy Production remnirr j 10,170, 10,770 EstirrratA,Energypso Ef 6L-ncy Savin' s, tk,ovt °ri 2,QCPti 6 00�1 Solar + Ehgrc!Mro Estfmata ! Annual Sena it clot ,im 12,170.. 16.770 Wntiliy L'Ohiates tr4�nrrt r 769. i,008 • ihosolar energy producaan provided hereSanfy an esiir=isCe tl dpzs naitaFie Ipto aceauniapy, ire-Ezisfing shadz:issues The35nai safk r,enerpy pro5u..Hon guarantee willYe'issued ait�rthe jotzic complete and Cased on ite �ahade mzasurernenfs conducted tit fiW daynrinsta}(atian. •Results atom the euetfyy t tF«arty wark conducted by Enemyprc are eAimaaes.atilyand ca_nnat Ca guaranteed as Eery home utilizes different ccnstiucnori,m>*6ad . EStirria d. Mgnthly Pa°citiuctYat :onn -- -- -- — - ----- - -- - --- @W — — — -- _ ----- - — tie ®I.v.acrf,u.,l I-2 I, Charles Rowe , APPROVE THE PROPOSED DESIGN AND��`t72--z- ' ESTIMATED* ENERGY SAVINGS FOR MY SOLAR PANEL INSTALLA`I01 pp ��DocuSS�lgned by, LOCATION: pierce FL 3d951 M A R C J ON E S, INSTALL: 6.6 KWh SOLAR PANEL SYSTEM CONSTRUCTION ,-identic I-Eo.-6.l-:olar JURISDICTION: ST. LUCIE I UTILITY: FPL I Lf�ISPtR� DESIGNER: Zdch OLmstedd DATE: 10.05.16 I REV: 01 1 SHEET: 11 OF 31 25 \� JUST IN- ^ARRA ]SYEAPGUAPANTCE TIME 4 300 Wp 60 Cell Monocrystalline PV Module C E I EC F[]] (TUV) ,%w Fraunhofer I.mCr.. �� IniA�riuk.. ISE ENSURES MAXIMUM EFFICIENCY 60 of the highest efficiency, premium quality monocrystalline cells result in a maximum power rating of 300Wp. ADVANCED PERFORMANCE WARRANTY 25-year linear power performance guarantee to 82% '• ENHANCED PRODUCT WARRANTY 12-year product/workmanship warranty A BUILT BY INDUSTRY EXPERTS With over 35 years of industry experience, Silfab's technical " team are pioneers in PV technology and are dedicated to an innovative approach that provides superior manufacturing processes including: infra -red cell sorting, glass washing, automated soldering and meticulous cell alignment. ', • POSITIVE TOLERANCE (-0/+5W) All positive module sorting ensures maximum performance lil $$$ j=HIGH [i0t¢nCY ., 44 PPM DEFECT RATE* Total automation ensures strict quality control during each step of the process at our certified ISO manufacturing facility. *As of December 31, 2016 LIGHT AND DURABLE Over -engineered to weather low load bearing structures up to 5400 Pa. Light -weight frame exclusively designed with wide-ranging racking compatibility and durability. <, , PID RESISTANT Proven in accordance to IEC 62804-1 AVAILABLE IN All Black i SpecificationsElectrical Test Conditions STC . . NOCT - Module Power (Pmax) Wp 300 227 Maximum power voltage (Vpmax) V 32.8 ; 29.5 Maximum power current (Ipmax) A 9.16 7.69 OpenI circuit voltage (Voc) V 39.85 36.9 Short circuit current (Isc) A 9.71 7.96 Module efficiency % 18.4 17.3 Maximum system voltage (VDC) V 1000 Series fuse rating Powe l� Tolerance A Wp 15 -0/+5 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 eC • NOCT 800 W/m2 • AM 1.5 • Measurement uncertainty5 3% • Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by f5%and power by-0/+5. Temperature Coefficient Isc %/K 0.03 Temperature Coefficient Voc %1K -0.30 Module weight (t 1 kg) kg 19 Dimensions (H x L x D; t 1 mm) mm 1650 x 990 x 38 Maximum surface load (wind/snow)* N/mz 5400 Hail impact resistance o 25 mm at 83 km/h Cells 60 - Si monocrystalline - 4 or 5 busbar-156.75 x 156.75 mm Glass 3.2 mm high transmittance, tempered, antireflective coating Backsheet Multilayer polyester -based Frame Anodized Al Bypass diodes 3 diodes-45W12A, IP67/IP68 Cables and connectors (See installation manual) 1200 mm o.5.7 mm (4 mm2), MC4 compatible Module 'product warranty 12 years 25 years z 97% end of 151 year Linear power performance guarantee >_ 90% end of 121h year. z 82% end of 251h vear Product LL Warning: Read the installation and User Manual before 1 handling, installing and operating modules. V VERFO% Third -party generated pan files from ~� 201 4 PV Evolution Labs available (( for download at: oNv�I www.silfab.ca/downloads \"MODDIE I RM=1UNSCORECMD ULC ORD C1703, UL 1703, IEC 61215, IEC 61730, IEC 61701, CEC listed UL Fire Rating: Type _2_(Type 1 on request) ISO 9001:2008 ..i Pallet Count: 26 3 Container Count: 936 Silfalb SOLAR Silfab Solar Inc. 240 Courtneypark Drive East • Mississauga, Ontario Canada L5T 2S5 Tel +1 905-255-2501 • Fax +1 905-696-0267 info@silfab'.ca • www.silfab.ca 8 DrelnD o .8 Groundin Hole a 1 d •� TYtz .4 Allot 0 N � c.G Profile Vlow D e a e4.z .z Grounding Hole M� DMMulau In 11Rn Teur.nw:ttmm H.I. tebnnee.: 10.z— Dr.wRp. n...c 958 9 i Sheet lase Microinverters on; US phase 7 and IQ 7+ Microinverters i i i To lean The high-powered smart grid -ready Enphase IQ 7 Micro'M and Enphase IQ 7+ Micro.. dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate seamlessly with the Enphase IQ Envoy'", Enphase Q Aggregator"', Enphase IQ Battery"', and the Enphase Enlighten' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, F enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double -insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. enphase.com � E N P H A S E. Enphase IQ 7 and IQ 7+ Microinverters Commmonly used module pairings' 235 W -350 W + Module compatibility 60-cell PV modules only Maximum input DCvoltage Pea power tracking voltage 27 V - 37 V I Operating range ^_ - - - - 16 V�48 V -- ! Max DCF -PV a 4ax start voltage 22 V / 48 V iC short circuit current (module.lsc) - - 15 A -- ---- --- ---------------- - _._ oltage class DC port II rt backfeed current 0 A IQ7PLUS-72-2-US 235 W - 440 W + 60-cell and 72-cell PV modules 27V-45V -16 V - 60 V 22V/60V •0 A ray configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter I 'Peak output power 250: VA 295 VA Maximum continuous output power 240 VA 290 VA ommal (L--L) voltage/range2 240 V / 208 V / 240 V 7 208 V / 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A Nominal frequency 60'Hz-- 60 Hz Extended frequency range -- 47 - 68 Hz 47 - 68 Hz --_--1-_-__;_______—_--__—___.-_._------__---_-_..-_-_ i AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (240 VAC) 13 (208 VAC) 11 (208 VAC) Overvoltage class AC port AC port backfeed current 0 A 0 A ! Power factor setting Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC'effi_ciency 97.6'°i° 97:6 °io 97.5 % 97.3 % 4 CEC weighted efficiency 97.0 °i° g y 97.0 i° 97.0 i° 97.0 i° MECHANICAL DATA IQ 7 Microinverter i Ambienl temperature range -40°C to +65°C Relative humidity range 4%to 100% (condensing) Connector type -�MC4 (or Amphenol:H4 UTX with additional Q-DCC-5 adapter) Dimensions (WxHxD) - 212 mm x 175 mm x 30.2 mm (without bracket) Weight iII - — - 1.08 kg (2.38 lbs)• _ _ Cooling _ Natural convection No fans - Approved for wet locations Yes Pollution degree PD3 a Enclosure Environmental UV Class II^double-insulated,.corrosion resistant polymeric enclosure category / exposure rating NEMA Type 6 / outdoor FEATURES Communication Power tine Communication (PLC) i Monitoring Enlighten Manager and MyEnlighten monitoring options, Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by.NEC 690. Compliant e _ CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at hit p • /enphase com/en-us/support/module-commpatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits mayivary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v ENPHASE. © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2.018-02-08