HomeMy WebLinkAboutLETTER - HIGH WIND RESISTANT CONSTRUCTION CERTIFICATEK
PRINCIPAL
Engineering
1011 N Causeway Blvd, Suite 19 ♦ Mandeville, Louisiana 70471 ♦ Phone: 985,624.5001 ♦ Fax: 985.624.5303
October 2018
RECEIVED
St. Lucie County, FL NOV St. 0 2018
Property Owner: Charles Rowe I I ST.
Property Address: 7901 Santa Clara Blvd., St. Lucie, Florida 34951
Re: HIGH WIND -RESISTANT CONSTRUCTION CERTIFICATE
SCANNED
StLucie County
Wind loads have been calculated for a speed of 157 MPH. The roof pitch and construction have
been analyzed, and the photovoltaic system structure designed to resist resulting uplift and
downward forces. The attached drawings and diagrams reflect a design that safely transmits
dead and live loads to the roof. To the best of my professional knowledge and belief, the subject
construction and photovoltaic system installation will be in compliance and designed to 2017
Florida Building Code 6th Edition at the time of our review.
i
'0
ST.LUCIE COUNTY
REVIEW,
PLAN
BLDG:
ELEC:_-__
DATE`
PLUMB:
DATE;,�,,.�_.
MECK�—
DATE:
.X I
/I!'f,�J�-''�
i `d �f �� IJ �Fl,,�.�
c� i %FJ��•J.....1 2,
PRINCIPAL InfrastructureT M
Architecture ♦ Engineering ♦ Construction
1�,1111118181i
41
+*
No.71950 wo
�C rx
W
STATE OF �I�
w
Firm No. 30649
Principal Engineering, Inc.
www.pi:aec.com ♦ info@pi-aec.com
Uplift and Wind Downforce Calculation Summary (ASCE 7-05 Method 1)
Mount. Rack. & Panel Pronortionin>±
Property Owner:
Charles Rowe
Individual Panel Dimensions
Project Address:
7901 Santa Clara Blvd.
Length (in)l
Width'(in)
Area (sf)
City, State:
St. Lucie, Florida 34951
77
39
20.85
Building Characteristics, Design Input, and Adjustment,Factors
Basic Wind Speed:
Exposure Category:
Occupancy Category:
Effective Wind Area (sf):
Roof Dimensions: Length:
Width:
Lf Height (h):
Pitch: 2joh 12 =
Ht. & Exposure lustment (A)
Iportance Factor (1)
ml
TO Adj. (K,.t)
157
From Code Office or Fig. 6-1
Para 6.5.6.3
Table.1-1
Para 6.2 (Area per individual fastener)
'Least Dimension: 5.5
Fig 6-3, Note 5, must be less than 60
degrees; must be less than 45
Fig. 6-3
Table 6-1
Para 6.5.7
B
2
10
60
55
24
26.6
1
1
1
. i Roof Zone Strip (a), in ft, Fig. 6-3, Note 5
1' Least Roof Horizontal Dimension (L or W) X 0.10
2 Roof Height x 0.4
3 ! Least Roof Horizontal'Dimension (L or W) x 0.04
4 Least of (1) and (2)
5 - Greater of (3) and (4)
6 - Greater of (5) and.3 feet a=
0.55
9.6
0.22
5.5
5.5
5.5
,p�9!l1111��,0
CD
4%
s
•
*
No. 71950
D: =
Oft�+
STATE OF Ar
10
�& ORIoP
to I
r
0
(� �-3L9 ��
Net Design Pressures (Fig 6-3), Components & Cladding
Uplift (-psf)
Down (psf)
30net zt 30net
30net zt 30net
Zone 1
40.7 40.7
25.6 25.6
Interior Roof Area
Zone 2
70.9 70.9
25.6 25.6
Strip of (a) ft wide at root edge
Zone 3
104.9 104.9
25.6 25.6
Corner intersection of strips
Mount & Rail Selection .
Manufacturer:
Nucor
Perpindicu/ar Panel Orientation
Model:
Allowable Scheme by Uplift Pressure
S-5-U Mini
Ultimate Uplift (lb):
< 60 psf 2 rails, 4"-0" OC mounts
60-90 psf 3 rails, 4'-0"; or 2 rails, 2'-0"
90-110 psf 4 rails, 4%0" OC mounts
1913
Parallel: Mounts per Individual Panel
# Mounts FS
Zone 1 1.5 3.4
110-150 psf 3 rails, 2'-0" OC mounts
Zone 2 3.3 4.3
150-170 psf4 rails, 2'-0" OC mounts
Zone 3 3.3 2.9
1170 psf +, panel clip capacity exceeded
(From, rail analysis, allowable pressures controlled by individual mount pullout before rail bending)
Firm No. 30649
Principal Engineering, Inc.
THIS EDGE TOWARDS ROOF RIDGE
'he engineer's seal and signature
n this manufacturer's drawing cc
ie product for use in this project
4.50
W
IX
of2.00
397
0.3.30
1.00
.040
1.77
ITEM DESCRIPTION QTY.
NO.
1 FLASHING, ROUNDED _CORNERS,__9"X_L2"-X-.040"-5052-MILL----1-
2 L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 6061-T6/6005A-T61, MILL 1
3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1
4 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1
L-FOOT 2" X 3.30", 2 X .75" SLOT FOR .438" O.D. FASTENER, 6061- 1
T6/6005A-T61. MILL
I O,',Oifi7l/gd,d
1200.
No.71950
3.00 (4 120 p STATE OF 4r�
4
3
' str,` �C O R\9�'
2
QMLM2:
2 X .75" SLOT
VERSION
* OPTIONAL
o
2.00
0.397 TYP
1.00
Al f 1
irm No. 30649
3.30 Principal Engineering, Inc
.75 0_ AVAILABLE IN MILL, AND BLACK FINISHES
.25 1.14
.751 Quick Mount PVu
TITLE:
(2.50) (3.54) QMLM2 5/16" LAG, 9"
Charles Rowe QMLM: L-MOUNT,
i X 12" FLASHING
QMLM
7901 Santa Clara Blvd.
UNLESS OTHERWISE SPECIFIED:
SIZE
A
I DRAWN BY: RAD
REV
6
St. Lucie, Florida 349511
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL± 1 /8
TWO PLACE DECIMAL ±.19
THREE PLACE DECIMAL ±.094
DATE: 8/23/2017
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAW ING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE DO NOT SCALE DRAWING
WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT ® 2016 QUICK MOUNT PV
SCALE: 1:4
WEIGHT:1.0241
SHEEP 1 OF 1
5 4
3
2
1
,l
Address:
following components installed per the attached diagrams and plans will comply with the required mph
ultimate wind loads in
attached plans labeled as follows; Quick Mount PV, L-Foot Layout, Rail Layout, Solar array Layout.
le Compliant Unirac Solar Installation Components.
iirac SolarMount Rail Components
The engineer's seal and signature
on this manufacturer's drawing certifies
the product for use in this project only.
i
ORail — Supports PV modules. Use two per row of
I Aluminum extrusion, anodized.
© Rail splice —Joins and aligns rail sections into single
length of rail. It can form either a rigid or thermal
expansion joint, 8 inches long, predrilled. Aluminum
extrusion, anodized.
© Self -drilling screw — (No. 10 x 3/a") — Use 4 per rigid
splice or 2 per expansion joint. Galvanized steel:
O L-foot — Use to secure rails either through roofing
ii
material to building structure or standoffs. Refer to
loading tables for spacing. Note: Please contact Unirac
forl use and specification of double L -foot.
© L-foot bolt (3/8" x 3/a") — Use one per L-foot to secure
raillto L-foot. Stainless steel.
OFlange nut (3/8") — Use one per L-foot to secure rail to
L-foot. Stainless steel. 1, ,11111111t,•11��
`; plFfiRq��; .�J
:�o��� vOGENsF ®��
No. 71950
X
� w-
G STATE OF
10
�10 ,S' 1 01
44*1
/2 —30
Figure 4. SolarMount standard rail components.
lock washer for attaching L foot. Flashings: Use one per
standoff. Unirac offers appropriate flashings for both
standoff types.
OLag screw for L-foot (5/ 16") — Attaches standoff to
rafter. See PV Quickmount Notes below.
(i Top Mounting Clamps
• Top Mounting Grounding Clips and Lugs
ADDITONAL NOTES:
• PVQUICKMOUNT—Attaches L-foot or standoff to
rafter. install per attached Quickmount PV detail; QMSC:
Classic composition mount dated 7/19/2012. If lag screw
head is exposed to elements, use stainless steel. Under
flashings, zinc plated hardware is adequate.
Waterproof rooting sealant — Use a sealant appropriate
to your roofing material. Consult with the company
currently providing warranty of roofing.
611
Firm -No. 30649
Principal Engineering, Inc.
DocuSign Envelope ID:'28751338'4B70-4541-B71A-73A484A8AF613
SUNPRO INSTALLATION MAP Rowe, Charles
( 22 ) SiLfab 30OW
( 22 ) ENPHASE IQ7
Fst mated:
Energy's vings
krsnual }2eslitrs
1,0;470.kWh per. Year'
Low. -F(igh:
Esill-nai'ecl Solar Ehergy Production remnirr j
10,170, 10,770
EstirrratA,Energypso Ef 6L-ncy Savin' s, tk,ovt °ri
2,QCPti 6 00�1
Solar + Ehgrc!Mro Estfmata ! Annual Sena it clot ,im
12,170.. 16.770
Wntiliy L'Ohiates tr4�nrrt r
769. i,008
• ihosolar energy producaan provided hereSanfy an esiir=isCe tl dpzs naitaFie Ipto aceauniapy, ire-Ezisfing
shadz:issues The35nai safk r,enerpy pro5u..Hon guarantee willYe'issued ait�rthe jotzic complete and Cased on ite
�ahade mzasurernenfs conducted tit fiW daynrinsta}(atian.
•Results atom the euetfyy t tF«arty wark conducted by Enemyprc are eAimaaes.atilyand ca_nnat Ca guaranteed as
Eery home utilizes different ccnstiucnori,m>*6ad .
EStirria d. Mgnthly Pa°citiuctYat
:onn -- -- -- — - ----- - -- - ---
@W — — —
-- _ ----- -
—
tie
®I.v.acrf,u.,l
I-2
I, Charles Rowe , APPROVE THE PROPOSED DESIGN AND��`t72--z-
'
ESTIMATED* ENERGY SAVINGS FOR MY SOLAR PANEL INSTALLA`I01
pp ��DocuSS�lgned by,
LOCATION: pierce FL 3d951
M A R C J ON E S, INSTALL: 6.6 KWh SOLAR PANEL SYSTEM
CONSTRUCTION
,-identic I-Eo.-6.l-:olar JURISDICTION: ST. LUCIE
I UTILITY: FPL I
Lf�ISPtR� DESIGNER: Zdch OLmstedd
DATE: 10.05.16 I REV: 01 1 SHEET: 11 OF 31
25 \� JUST
IN-
^ARRA ]SYEAPGUAPANTCE TIME
4
300 Wp
60 Cell
Monocrystalline
PV Module
C E I EC F[]] (TUV) ,%w Fraunhofer
I.mCr..
�� IniA�riuk.. ISE
ENSURES MAXIMUM EFFICIENCY
60 of the highest efficiency, premium quality monocrystalline
cells result in a maximum power rating of 300Wp.
ADVANCED PERFORMANCE WARRANTY
25-year linear power performance guarantee to 82%
'• ENHANCED PRODUCT WARRANTY
12-year product/workmanship warranty
A
BUILT BY INDUSTRY EXPERTS
With over 35 years of industry experience, Silfab's technical
" team are pioneers in PV technology and are dedicated to an
innovative approach that provides superior manufacturing
processes including: infra -red cell sorting, glass washing,
automated soldering and meticulous cell alignment.
', • POSITIVE TOLERANCE
(-0/+5W) All positive module sorting ensures
maximum performance
lil
$$$ j=HIGH
[i0t¢nCY
., 44 PPM DEFECT RATE*
Total automation ensures strict quality control during each
step of the process at our certified ISO manufacturing facility.
*As of December 31, 2016
LIGHT AND DURABLE
Over -engineered to weather low load bearing structures up
to 5400 Pa. Light -weight frame exclusively designed with
wide-ranging racking compatibility and durability.
<, , PID RESISTANT
Proven in accordance to IEC 62804-1
AVAILABLE IN
All Black
i
SpecificationsElectrical
Test Conditions
STC
. .
NOCT
- Module Power (Pmax)
Wp
300
227
Maximum power voltage (Vpmax)
V
32.8
; 29.5
Maximum power current (Ipmax)
A
9.16
7.69
OpenI circuit voltage (Voc)
V
39.85
36.9
Short circuit current (Isc)
A
9.71
7.96
Module efficiency
%
18.4
17.3
Maximum system voltage (VDC)
V
1000
Series fuse rating
Powe l� Tolerance
A
Wp
15
-0/+5
Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 eC • NOCT 800 W/m2 • AM 1.5 • Measurement uncertainty5 3%
• Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by f5%and power by-0/+5.
Temperature Coefficient Isc %/K 0.03
Temperature Coefficient Voc %1K -0.30
Module weight (t 1 kg) kg 19
Dimensions (H x L x D; t 1 mm) mm 1650 x 990 x 38
Maximum surface load (wind/snow)* N/mz 5400
Hail impact resistance o 25 mm at 83 km/h
Cells 60 - Si monocrystalline - 4 or 5 busbar-156.75 x 156.75 mm
Glass 3.2 mm high transmittance, tempered, antireflective coating
Backsheet Multilayer polyester -based
Frame Anodized Al
Bypass diodes 3 diodes-45W12A, IP67/IP68
Cables and connectors (See installation manual) 1200 mm o.5.7 mm (4 mm2), MC4 compatible
Module 'product warranty 12 years
25 years
z 97% end of 151 year
Linear power performance guarantee >_ 90% end of 121h year.
z 82% end of 251h vear
Product
LL Warning: Read the installation and User Manual before
1 handling, installing and operating modules.
V VERFO%
Third -party generated pan files from ~� 201 4
PV Evolution Labs available ((
for download at: oNv�I
www.silfab.ca/downloads \"MODDIE
I RM=1UNSCORECMD
ULC ORD C1703, UL 1703, IEC 61215, IEC 61730, IEC 61701, CEC listed
UL Fire Rating: Type _2_(Type 1 on request)
ISO 9001:2008
..i Pallet Count: 26
3 Container Count: 936
Silfalb
SOLAR
Silfab Solar Inc.
240 Courtneypark Drive East • Mississauga,
Ontario Canada L5T 2S5
Tel +1 905-255-2501 • Fax +1 905-696-0267
info@silfab'.ca • www.silfab.ca
8
DrelnD o .8
Groundin
Hole
a
1
d
•�
TYtz .4
Allot
0
N
�
c.G
Profile Vlow
D
e
a
e4.z .z
Grounding
Hole
M� DMMulau In 11Rn
Teur.nw:ttmm
H.I. tebnnee.: 10.z— Dr.wRp. n...c
958
9
i Sheet
lase Microinverters
on; US
phase
7 and IQ 7+
Microinverters
i
i
i
To lean
The high-powered smart grid -ready
Enphase IQ 7 Micro'M and Enphase IQ 7+ Micro..
dramatically simplify the installation process while
achieving the highest system efficiency.
Part of the Enphase IQ System, the IQ 7 and
IQ 7+ Microinverters integrate seamlessly with
the Enphase IQ Envoy'", Enphase Q Aggregator"',
Enphase IQ Battery"', and the Enphase Enlighten'
monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power -on testing,
F enabling Enphase to provide an industry -leading
warranty of up to 25 years.
Easy to Install
• Lightweight and simple
• Faster installation with improved, lighter two -wire cabling
• Built-in rapid shutdown compliant (NEC 2014 & 2017)
Productive and Reliable
• Optimized for high powered 60-cell and 72-cell* modules
• More than a million hours of testing
• Class II double -insulated enclosure
• UL listed
Smart Grid Ready
• Complies with advanced grid support, voltage and
frequency ride -through requirements
• Remotely updates to respond to changing
grid requirements
• Configurable for varying grid profiles
• Meets CA Rule 21 (UL 1741-SA)
* The IQ 7+ Micro is required to support 72-cell modules.
enphase.com � E N P H A S E.
Enphase IQ 7 and IQ 7+ Microinverters
Commmonly used module pairings'
235 W -350 W +
Module compatibility
60-cell PV modules only
Maximum input DCvoltage
Pea power tracking voltage
27 V - 37 V
I Operating range ^_ - - -
- 16 V�48 V --
! Max
DCF
-PV a
4ax start voltage 22 V / 48 V
iC short circuit current (module.lsc) - - 15 A
-- ---- --- ---------------- - _._
oltage class DC port II
rt backfeed current 0 A
IQ7PLUS-72-2-US
235 W - 440 W +
60-cell and 72-cell PV modules
27V-45V
-16 V - 60 V
22V/60V
•0 A
ray configuration 1 x 1 ungrounded array; No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA (AC)
IQ 7 Microinverter
IQ 7+ Microinverter
I 'Peak output power
250: VA
295 VA
Maximum continuous output power
240 VA
290 VA
ommal (L--L) voltage/range2
240 V / 208 V /
240 V 7
208 V /
211-264 V 183-229 V
211-264 V
183-229 V
Maximum continuous output current
1.0 A 1.15 A
1.21 A
1.39 A
Nominal frequency
60'Hz--
60 Hz
Extended frequency range
--
47 - 68 Hz
47 - 68 Hz
--_--1-_-__;_______—_--__—___.-_._------__---_-_..-_-_
i AC short circuit fault current over 3 cycles
5.8 Arms
5.8 Arms
Maximum units per 20 A (L-L) branch circuit'
16 (240 VAC)
13 (240 VAC)
13 (208 VAC)
11 (208 VAC)
Overvoltage class AC port
AC port backfeed current
0 A
0 A
! Power factor setting
Power factor (adjustable)
0.7 leading ... 0.7 lagging
0.7 leading ... 0.7 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peak CEC'effi_ciency 97.6'°i° 97:6 °io 97.5 % 97.3 % 4
CEC weighted efficiency 97.0 °i°
g y 97.0 i° 97.0 i° 97.0 i°
MECHANICAL DATA IQ 7 Microinverter
i Ambienl temperature range
-40°C to +65°C
Relative humidity range
4%to 100% (condensing)
Connector type -�MC4
(or Amphenol:H4 UTX with additional Q-DCC-5 adapter)
Dimensions (WxHxD)
-
212 mm x 175 mm x 30.2 mm (without bracket)
Weight
iII - — -
1.08 kg (2.38 lbs)• _ _
Cooling
_
Natural convection No fans -
Approved for wet locations
Yes
Pollution degree
PD3
a
Enclosure
Environmental UV
Class II^double-insulated,.corrosion resistant polymeric enclosure
category / exposure rating
NEMA Type 6 / outdoor
FEATURES
Communication Power tine Communication (PLC) i
Monitoring Enlighten Manager and MyEnlighten monitoring options,
Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break
disconnect required by.NEC 690.
Compliant e _ CA Rule 21 (UL 1741-SA)
UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC
and DC conductors, when installed according manufacturer's instructions.
1. No enforced DC/AC ratio. See the compatibility calculator at hit p • /enphase com/en-us/support/module-commpatibility.
2. Nominal voltage range can be extended beyond nominal if required by the utility.
3. Limits mayivary. Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings, visit enphase.com
v ENPHASE.
© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc.
2.018-02-08