Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method `F ' j 44Ct Name: TRISTEN & ALEXIS TREFELNER Builder Name: QUICK CALCS, INC. "CStreet: SLASH PINE TRAIL Permit Office: ST. LUCIE COUNTYB® City, State, Zip: FT. PIERCE, FL, ; Permit Number: ✓�3 ��e%'Ze Owner: TRISTEN & ALEXIS TREFELNER Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) Loo(�rj 1. New construction or existing New (From Plans) 9. Wall Types (2460.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2460.00 ft2 3. Number Qf units, if multiple family 1 b. N/A N/A R= ft2 c. R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 1 10. Ceiling Types (2459.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2459.00 ftZ 6. Conditioned floor area above grade (ft2) 2459 b. N/A R= ft2 0 Conditioned floor area below grade (ft2)11. c. 2 R= ft Duuctct s R ft2 7. Windows673.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Dbl, U=0.65 302.00 ft2 SHGC SHGC=0.25 b. U-Factor: Dbl, U=0.65 71.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGd: SHGC=0.30 a. Central Unit 41.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC.: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC� Area Weighted Average Overhang Depth: 4.223 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems 8. Floor Types (2459.0 Insulation Area a. Propane Tankless Cap: 1 gallons sqft.) a. Slab Edge Insulation R=0.0 2459.00 ft2 EF: 0.600 -On -Grade b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/FloorArea: 0.152 Total Proposed Modified Loads: 81.80 PASS Total Baseline Loads: 83.80 I hereby certify that the by Review plans and specifications covered of the plans and 4�E this calculation are in compliance with the Florida Energy specifications covered by this0� _0�, Code. calculation indicates compliance with the Florida Energy Code. O PREPA Y' DATE: Before construction is completed this building will be inspected for r O �� compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: i /1 J�1XIF. DATE: - vvu�Nuai certified - Compliar envelope li 10/31 /2018 requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as iory-sealed in accordance with R403.3.2.1. requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an age test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FI LE C . PY DEC 0 2010 10:04 AM EnergyGauge® USA Section R405.4.1 NOV 212018 ST. Lucie County, Permitting .r M C n ,9.d Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT. I Title: TRISTEN & ALEXIS TREFEL Bedrooms: 3 Address Type: Street Address Building, type: User Conditioned Area: 2459 Lot # -Owner Name: TRISTEN & ALEXIS TREFEL Total Stories: 1 Block/Subdivision: # of Units, 1 Worst Case: No PlatBook: Builder Name: QUICK CALCS, INC. Rotate Angle: 0 Street: SLASH PINE TRAIL Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Ty?e: Single-family FL, New/Existing: New (From Plans) Comment CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI .39 90 70 75 299 62 Low BLOCKS Number) Name Area Volume 1 Entire House 2459 24590 SPACES Number j Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BATH 215 2150 No 0 1 Yes Yes Yes 2 TLT. 18 180 No 0 1 No Yes Yes 3 BEDROOM 1 221 2210 No 1 1 1 Yes Yes Yes 4 WIC 122 1220 No 0 1 No Yes Yes 5 BEDROOM 2 206 2060 No 1 1 1 Yes Yes Yes 6 BATH 2 54 540 No 0 1 Yes Yes Yes 7 BEDROOM 3 185 1850 No 1 1 1 Yes Yes Yes 8 FOYER 145 1450 No 0 1 Yes Yes Yes 9 GREAT ROOM 408 4080 No 4 1 Yes Yes Yes 10 DEN 143 1430 No 0 1 Yes Yes Yes 11 I I POWDER 28 280 No 0 1 No Yes Yes 12 PANTRY 24 240 No 0 1 No Yes Yes 13 I KITCHEN 205 2050 Yes 0 1 Yes Yes Yes 14 DINING 169 1690 No 0 1 Yes Yes Yes .15 HALL 60 600 No 0 1 No Yes Yes 16 ENTRY 112 1120 No 0. 1 Yes Yes Yes 17 LAUNDRY 144 1440 No 0 1 Yes Yes Yes 10/3112018110:04 AM EnergyGauge® USA' Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BATH 33 ft 0 215 ft2 ---- 0 1 0 i 2 Slab -On -Grade Edge Insulatio TLT. 1 ft 0 18 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio BEDROOM 1 19 ft 0 221 ft2 __-_ 0 1 0 4 Slab -On -Grade Edge Insulatio WIC 1 ft 0 122 ft2 -_-- 0 1 0' 5 Slab -On -Grade Edge Insulatio BEDROOM 2 30 ft 0 206 ft2 _-__ 0 1 0 6 Slab -On -Grade Edge Insulatio BATH 2 6 ft 0 54 ft2 --_- 0 1 0 7 Slab -On -Grade Edge Insulatio BEDROOM 3 19 ft 0 185 ft2 __-_ 0 1 0 8 Slab -On -Grade Edge Insulatio FOYER 9 ft 0 145 ft2 __-- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT ROOM 16 ft 0 408 ft2 _--- 0 1 0 0Slab-On-Grade Edge Insulatio DEN 17 ft 0 143 ft2 --_- 0 1 0 11SIab-On-Grade Edge Insulatio POWDER 1 ft 0 28 ft2 ____ 0 1 0 1I2SIab-On-Grade Edge Insulatio PANTRY 1 ft 0 24 ft2 ____ 0 1 0 �3SIab-On-Grade Edge Insulatio KITCHEN 15 ft 0 205 ft2 ____ 0 1 0 �4Slab-On-Grade Edge Insulatio DINING 34 ft 0 169 ft2 ____ 0 1 0 1,5SIab-On-Grade Edge Insulatio HALL 1 ft 0 60 ft2 ---- 0 1 0 16SIab-On-Grade Edge Insulatio ENTRY 23 ft 0 112 ft2 ---_ 0 1 0 17SIab-On-Grade Edge Insulatio LAUNDRY 25 ft 0 144 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) Hip Metal 2591 ft2 0 ft2 Light 0.6 No 0.9 No 20 18.4 ATTIC # V Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic I Unvented 0 2459 ft2 N N 10/31/2018110:04 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BATH 20 Blown 215 ft2 0.1 Wood 2 Under Attic (Unvented) TLT. 20 Blown 18 ft2 0.1 Wood 3 Under Attic (Unvented) BEDROOM 1 20 Blown 221 ft2 0.1 Wood, Under Attic (Unvented) WIC 20 Blown 122 ft2 0.1 Wood 5 Under Attic (Unvented) BEDROOM 2 20 Blown 206 ft2 0.1 Wood 6 Under Attic (Unvented) BATH 2 20 Blown 54 ft2 0.1 Wood 7 Under Attic (Unvented) BEDROOM 3 20 Blown 185 ft2 0.1 Wood 8 Under Attic (Unvented) FOYER 20 Blown 145 ft2 0.1 Wood 9 Under Attic (Unvented) GREAT ROOM 20 Blown 408 ft2 0.1 Wood 10 Under Attic (Unvented) DEN 20 Blown 143 ft2 0.1 Wood 1I1 Under Attic (Unvented) POWDER 20 Blown 28 ft2 0.1 Wood 112 Under Attic (Unvented) PANTRY 20 Blown 24 ft2 0.1 Wood 13 Under Attic (Unvented) KITCHEN 20 Blown 205 ft2. 0.1 Wood 1,4 Under Attic (Unvented) DINING 20. Blown 169 ft2 0.1 Wood 15 Under Attic (Unvented) HALL 20 Blown 60 ft2 0.1 Wood 16 Under Attic (Unvented) ENTRY 20 Blown 112 ft2 0.1 Wood 17 Under Attic (Unvented) LAUNDRY 20 Blown 144 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ _ 1 N Exterior Concrete Block - Ext InsMASTER BA 4.1 22 0 10 0 220.0 ft2 0 0 0.6 0 _ 2 6Exterior Concrete Block - Ext InsMWSTER BA 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 _ 3 S Exterior Concrete Block - Ext IndKDROOM 1 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 4 Exterior Concrete Block - Ext InfiffDROOM 1 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 5 Exterior Concrete Block - Ext InfiffDR00M 2 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 _ _ 6 W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 7 W Exterior Concrete Block - Ext Insul BATH 2 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 8 (uV Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 9 IW Exterior Concrete Block - Ext IndMDR00M 3 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 _ 10 W Exterior Concrete Block - Ext Insul FOYER 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 _ 11 E Exterior Concrete Block - Ext InGREAT ROO 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ext Insul DEN 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 13 W Exterior Concrete Block - Ext Insul DEN 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 14 S Exterior Concrete Block - Ext InsuKITCHEN 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 15 E Exterior Concrete Block - Ext InsuKITCHEN I 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 _ 16 E Exterior Concrete Block - Ext Insul DINING 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 17 Exterior Concrete Block - Ext Insul DINING 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 IS 18 N Exterior Concrete Block - Ext Insul DINING 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 19 S Exterior Concrete Block - Ext Insul ENTRY 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 _20 E Exterior Concrete Block - Ext Insul ENTRY 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _21 S Exterior Concrete Block - Ext InsalAUNDRY 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 _22 W Exterior Concrete Block - Ext InsL AUNDRY 4.1 16 0 '10 0 160.0 ft2 0 • 0 0.6 0 10/31/2018110:04 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang �/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 I N 1 Metal Low-E Double Yes 0.65 0.3 N 15.0 ft2 1 ft 5 in 7 ft 0 in None None 21 E 2 Metal Low-E Double Yes 0.65 0.25 N 12.0 ft2 1 ft 5 in 7 ft 0 in None None 31 S 3 Metal Low-E Double Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 5 in None None 41 E 4 Metal Low-E Double Yes 0.65 0.25 N 24.0 ft2 1 ft 5 in 7 ft 0 in None None 5 N 5 Metal Low-E Double Yes 0.65 0.25 N 18.0 ft2 1 ft 5 in 1 ft 5 in None None 6 W 7 Metal Low-E Double Yes 0.65 0.25 N 6.0 ft2 1 ft 5 in 7 ft 0 in None None 7 N 8 Metal Low-E Double Yes 0.65 0.25 N 18.0 ft2 8 ft 0 in 1 ft 5 in None None 8 W 10 Metal Low-E Double Yes 0.65 0.25 N 16.0 ft2 8 ft 0 in 1 ft 5 in None None 9 E 11 Metal Low-E Double Yes 0.65 0.3 N 40.0 ft2 14 ft 0 in 1 ft 4 in None None 10 E 11 Metal Low-E Double Yes 0.65 0.3 N 16.0 ft2 1 ft 5 in 7 ft 0 in None None 11 W 13 Metal Low-E Double Yes 0.65 0.25 N 18.0 ft2 8 ft 0 in 1 ft 5 in None None 12 S 14 Metal Low-E Double Yes 0.65 0.25 N 16.0 ft2 1 ft 5 in 7 ft 0 in None None 13 E 16 Metal Low-E Double Yes 0.65 0.25 N 18.0 ft2 1 ft 5 in 1 ft 5 in None None 14 S 17 Metal Low-E Double Yes 0.65 0.25 N 18.0 ft2 12 ft 0 in 1 ft.1 in None None 15 N 18 Metal Low-E Double Yes 0.65 0.25 N 54.0 ft2 1 ft 5 in 1 ft 5 in None None 16 S 19 Metal Low-E Double Yes 0.65 0.25 N 24.0 ft2 1 ft 5 in 7 ft 0 in None None 171 E 20 Metal Low-E Double Yes 0.65 0.25 N 16.0 ft2 1 ft 5 in 7 ft 0 in None None 181 S 21 Metal Low-E Double Yes 0.65 0.25 N 8.0 ft2 1 ft 5 in 7 ft 0 in None None 191 W I 22 Metal Low-E Double Yes 0.65 " 0.25 N 18.0 ft2 1 ft 5 in 7 ft 0 in None None INFILTRATION i # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehol use Proposed ACH(50) .000445 2868.8 157.5 296.19 .3446 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts Central Unit/ Split SEER: 16 41.5 kBtu/hr cfm 0.7 1 sys#1 10/31/2018I10:04 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 7 FORM R40.5-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation .1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM SEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF (None None ftZ DUCTS / — Supply --- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 108 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programa6le Thermostat: Y Ceiling Fans: Cooling Heatingg ] Jan X] Jan Feb XFeb [ Mar [Xj Mar Apr Apr f Jul May Jun Jul May r Junri Aug Aug rl Sep Se ri [ j [ ] Oct Oct Nov Nov HX Dec Dec H Ventin [ ] Jan [ Feb X Mar [X] A r [ Ma Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WDi) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 i PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/31/2018 10:04 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 i FORM R46 17 INPUT SUMMARY CHECKLIST MASS Masts Type Area Thickness Furniture Fraction Space Def I ult(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BATH ' Default(8lbs/sq.ft. ft2 ft 0.3 TLT. Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 1 DefjIult(8 lbs/sq.ft. ft2 ft 0.3 WIC Def., ult(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Def Iult(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 DEN DefIult(8 Ibs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Defalult(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN DefIult(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Defalult(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY Defalult(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Signature: ( 1 01112 b'XdkAZ-62QW - Compant: Date: lv A-1 I 10/31/2018 I10:04 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA_ TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TRISTEN & ALEXIS TREFELNER Builder Name: QUICK CALCS, INC. Street. SLASH PINE TRAIL Permit Office: ST. LUCIE COUNTY City, tate, Zip: FT. PIERCE, FL, Permit Number: Y U wn Oe I: TRISTEN & ALEXIS TREFELNER Jurisdiction: W Desig Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General j A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and an gaps in the air barrier shall be sealed. Y 9 P shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. I Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,1 skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilbvered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation i a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind p*pina and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior, wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklerssealed ) in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire spronki cover plates and walls or ceilings a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 10/31/2018 10:05 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Sinole-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 i 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 41.5 a) Split system SEER 16.0 5.16 this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2459 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity ' 34.0 c) Area 7c. 373.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.60 A. Exterior: �. Wood frame (Insulation R-value) 10A1. d) Solar system with tank EF e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other �. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 20.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy savi i g features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: SLASH PINE TRAIL City/FL Zip: FT. PIERCE, FL 10/31/2018110:05:00 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Pro ect Summaty Job: wrightsof Date: OCTOBER 31, 2018 Enure House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM For: TRISTEN &ALEXIS TREFELNER SLASH PINE TRAIL, ST. LUCIE COUNTY, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 27474 Btuh Ducts 5255 Btuh Central vent (78 cfm) 2396 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 35125 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating gg Cooling Area (ft�) 2459 2459 Molume (ft3) 24590 24590 Airchanges/hour 0.32 0.16 Equiv. AVF (cfm) 131 66 Heating Equipment Summary ref Heat flow factor 100 EFF 5.1 kW 17448 Btuh 50 OF 318 cfm 0.010 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 grAb Sensible Cooling Equipment Load Sizing Structure 24740 Btuh Ducts 4034 Btuh Central vent (78 cfm) 1284 Btuh Outside air Blower 0 - Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 28555 Btuh Latent Cooling Equipment Load Sizing Structure 4139 Btuh Ducts 3349 Btuh Central vent (78 cfm) 3253 Btuh Outside air Equipment latent load 10741 Btuh Equipment Total Load (Sen+Lat) 39295 Btuh Req. total capacity at 0.70 SHR 3.4 ton Cooling Equipment Summary Make Rheem Trade RHEEM; RUUD Cond RA1642AC1 Coil RH1T4821STAN AHRI ref 7942553 Efficiency 13.0 EER,16 SEER Sensible cooling 29050 Btuh Latent cooling 12450 Btuh Total cooling 41500 Btuh Actual airflow 1383 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.74 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft® 2018-Oct-31 08:40:04 a��• • �•. ..• Right-SUteOUrivemal201818.0.16 RSU08101 Page 1 Wrightsoft HVACITREFELNER, TRISTAN & ALEXIS.np Calc = MJ8 Frori Door faces: W FILE COPY. DEC 04 2010 -- wrightsoftl Right-JO Worksheet Job: Entire House Date: OCTOBER 31, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Rioom area Entire House 246.0 ft 10.0 It d 2459.0 fte MASTER BATH 33.0 ft 10.0 It heat/000l 1.0 x 215.0 It 215.0 ft' Ty Construdion number U-value (Btuh/ft-°F) Or HTM (B1uh1n Area (ft-) or perimeter (ft) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 - 13A-40cs 2 glazing, dr lowe 2 glazing, dr lowe 2 glazing, dr lowe :2 glazing,dr_IgW a 13A-4ocs 1Aclom 2 glazing, dr low-e 2 glazing, dr lowe 2 glazing, dr lowe 2 glazing, dr lowe 11_DO f3A- o 2glazing, drlowe 2 glazing„drlowe - 13AAocs 1013-v IA-clom 2glazing, drlowe 2glazing, drlowe 2 glazing, dr lowe 2 glazing dr lo_v�e- 0.143 0.280 0280 0.280 0.280 0.143 1.270 0.280 0.280 0.280 0.280 0.390 0.f43 0.280 0.280 n n n n .-n-- a a a a a a e_ s s - 4.00 7.84 7.84 7.84 -__-_7.8-4 4.00 35.56 7.84 7.84 7.84 7.84 10.92 4.00 7.84 f65- 8.18 8.18 10.28 10.28- 2.55 91.12 22.46 22.46 9.99 13.11 11.31 2.5@ 8.18 ---�J0.28. 2.55 12.02 91.12 22.46 22.46 22.46 32:07 520 24 24 18 18- 710 18 6 18 36 16 -•_. 21 .520 15 --18, 18, 710 40 16 12 24 16 -- 54 �436 0 0 0 __ -0; 595 0 0 0 31 10 w__21- 487 15 -18 548 40 0 0 0 0 0 7746 188 188 141 _ 1-41: 2382 640 47 141 282 125 229 1966 118 14-1 - 1110 196 196 185 _ 85 1 1515 1640 135 404 360 210 -_ 238 1240 123 185 1395 481 1458 269 539 359 1732 0 0 0 0 --0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0. - 0 0 0 0 _Q 0 0 0 0 0 0 0 Y_ , 0 0 0 0 0 0 0 -_ N% III _- 220 15 0 266- 15 0 321 118 0'--0 - _ 522 123 0.143 0.600 1.270 0.280 0280 0.280 0 280 -s- w w w w w w w -7.84 4.00 16.80 35.56 7.84 7.84 7.84 7.84 2194 672 569 94 188 125 423 110 0 0 12 0 0 0 98 0 0 0 0 0 0 392 0 0 94 0 0 0 249 0 0 269 0 0 0 --L-G C F _ l_.____ 16X1 &Omd 22A 1p1 �_0 408 0_989 _ - -1.59 27.69 1,49 OAO �2459 2459 _2459 246 -- 3899 6812 _ 3654 --. 0 - - 215 215 215 _ 33 341 914 _ 320 -_ 0 6 c) AED excursion 1341 -27 Fs%elope lossrgain 23438 19149 26801 1456 12 a) Infiltration b) Room ventilation 4036 0 1081 0 541 0 145 0 13 Intemalgain. Oocrpants@ 230 Appliances/other 7 1610 2900 0 0 0 Subtotal(lines 6to13) 27474 24740 3221 1601 14 15 Less exL-mal load Less transfer Redistribution Subtotal Duct loads ...... 19% 16% 0 0 0 27474 5255 0 ... .. -0 0 24740 4034 ........ 19% . .. .... 16% 0 .... .... - ,, 0 0 3221 616 0 . .-.0 . 0 1601 261 Total room load Air required (dm) 32729 318 28774 1383 3837 37 1862 89 of Manual J 8th �- wrigF�tsoTt� Right -Suite® Universal 201818.0.16 RSU08101 WrighfsoftHVAC)TREFELNER,TRISTAN&ALEXIS.rup Calc=MJ8 FrontDoor%oes: W 2018-Od-31 08:40:04 Page 1 -r-wrightsoft° Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. �LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Data: OCTOBER 31, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area TLT. 0 ft 10.0 ft heatImol 3.0 x 6.0 ft 18.0 ft2 BEDROOM 1 19.0 ft 10.0 ft heaftol 13.0 x 17.0 ft 221.0 W Ty Construction number U-value (BtrrhA1-'F) Or HTM (BfuhV) Area (ft� or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Bfuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 -- '13A-4ocs 2 glazing; dr lowe 2 glazing, dr lowe 2 glazing, dr loav-e 2 glazing, d[towe; 13A-4ocs 1A-clom 2 glazing, dr low-e 2 glazing, dr lowe 2 glazing, dr low-e 2 glazing, dr lowe 11DO 0.143 0.280 0.280 0280 0280 0.143 1270 0.280 0.280 0.280 0.280 0.390 n n n n, _n-_ a a a a a a e_ 4.00 7.84 7.84 , 7.84 ;:_-7:84 4.00 35.56 7.84 7.84 7.84 7.84 10.92 7. 5 8.18 8.18' 10.28 102$ 2.55 91.12 22.46 22.46 9.99 13.11 11.31 0 0 0 0 0_ 0 0 0 0 0- - 0 0 0 0 0: '- 0 0 0 0 0 60 0 0 0 18 - 42 0 0 0 - 0 0 0 0 0 0 0 0_ 168 0 0 0!. 141- 0 0 0 0 0 0 0_ 107 0 0 0 '- 185- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 { 13A-4ocs 2 glazing, dr lowe 2glazing,.drlow-e` 13A-4ocs 106-v 1Ai1om 2glazing, drlowe 2glazing, drlow-e 2glazing, drlowe 2glaanA,drlow-e 0.143 0.280 0280 0.143 0.600 1.270 0.280 0.280 0280 0280 s s -s_ w w w w w w w 4.00 7.84 -7.84 4.00 16.80 35.56 .7.84 7.84 7.84 7:64 2.55 8.18 1028 _ 0 0 0 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 270 0 0 0 539 0 0 W��------CGG 2.55 12.02 91.12 22.46 22.46 22.46 32.07 -0.-0.-0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 0 0 130 0 0 0 24 0 0 . -0 106 0 0 0 0 0 0 -0 424 0 0 0 188 0 0 _C F,�,- 16X19-0md 226-fpl 0408 0989 - _1.59 �27.69 .-149: 0.00 -. 18. 18 1 0 29 27 221. 221 221. 19 _ 36Q 526 328 0 0 0 - 6 c� AED exausion -21 85 Envelope loss!gain 29 25 1798 1514 12 a) Infiltration b) Room ventilation 0 0 0 0 312 0 83 0 13 Internal gains Occupants@ 230 Appliances(other 0 0 0 1 230 0 Subtotal(lines 6to13) 29 25 2110 1827 14 15 Lessextemalload L wtransfer lRedistribution Subtotal DUctloads 19% 16% 0 0 0 29 5 0 0 0 25 4 19% 16% 0 0 0 2110 404 0 0 0 1827 298 Total room load Air required (dm) 34 0 29 1 2514 24 2125 102 ACCAto -fjr&- wrigFttsof't- -� RightSuteOUrvversal201818.0.16RSU08101 WrightsoftWAMTREFELNER,TRISTAN&ALEXIS.nu Calc=MJ8 FrontDoorfaces: W 2018-Oct 31 08:40:04 Page 2 -�- w►rightsofte Right-JO Worksheet°b Entire House Date: OCTOBER 31, 2018 By: QUICK CALCS, INC. i 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area WIC 0 it 10.0 It heat/cool 1.0 x 122.0 ft 122.0 ft2 BEDROOM2 30.0 It 10.0 ft heat/cool 1.0 x 206.0 ft 206.0 ftz Ty Construction number U-value (BtuhAF-°F) Or HTM (Btuhd-) Area (W) or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11- ____ 13A-flocs 2 glazing, or low-e 2 glazing, dr lowe 2 glazing, dr lowe 2 glazing, dr lowe_ 13AAocs 1A-clom 2glazing, orlowe 2 glazing, or lowe 2 glazing, or lowe 2 glazing, dr lowe 11D0 _ 13A-4ocs 2 glazing, or low-e 2glazing, drlowe- 13A-4ocs 106-v 1Aclom 2 glazing, or lowe 2 glazing, or lowe 2glazing, orlowe 2glazinq,drlowe - 16X190md _ 22A tpl O.T43 0280 0.280 0.280 0.280 0.143 1.270 0.280 0.280 0.280 0.280 0.390 0.143 0.280 0.280 0.143 0.600 1.270 0.280 0.280 0.280 0.280 0.408 0_989 - n n n n -n_ a a a a a a _ e s s -s.- w w w w w w w_ 4100 7.84 7.84 7.84 - 7.84 4.00 35.56 7.84 7.84 7.84 7.84 10.92 �4.00 7.84 ,_,-7.84 4.00 16.80 35.56 7.84 7.84 7.84 7.84 1.59 -27.69 2.55 8.18 8.18 10.28 10.2$ 2.55 91.12 22.46 22.46 9.99 13.11 11.31 0 0 0 0 - _____ _ 0- 0 0 0 0 0 0 0 0_ 0 0 0 Q 0 0 0 0 0- 0 0 0 0 0 0 _-_0 0 0 0. 0 0 0 0 _0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 0 0 0 0 140 0 0 18 0 0 0 160 0 0 0 0 0 0 122 0 0 0 0 0 0 160 0 0 0 0 0 0 0 0 0 -- 0- 0 0 0 488 0 0 141 0 0 _ 0 641 0 0. 0 0 0 0 0 0 0 0 0 0 0 311 0 0 404 0 0 0 407 0 _ W- 2.55 8.18 _ 10.28 2.55 12.02 91.12 22.46 22.46 22.46 _ 32,07 1.49 - OAO 0 0 0 0 0 0 0 0 0 0 0 0- 122 T 122. _0. 0 0 0 0 0 0 0_ _ 122 0 0 0 0 0 0 0 0 193• 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _0 0 0 0 0 0 0 0 _-_ C - Fes_ _- - 181. 0 __206 _ -206 30 __327 831 - 306 0 _ _ __-206 - 6 c) AED excursion -11 -59 Eprvelope lossrgain 193 1701 2428 1369 12 a) Infiltration b) Room ventilation 0 0 0 0 492 0 132 0 13 Internal gains: Oo:upants@ 230 Appliancesrother 0 0 0 1 230 0 Subtotal (lines 6to 13) 193 170 2920 1731 14 15 Lessexhemalload Lesstransfer Rgdistribution Subtotal Duct loads 19% 16% 0 0 0 193 37 0 0 0 170 28 19% 16% 0 0 0 2920 559 0 0 0 1731 282 Total room load Air required (dm) 230 2 198 10 3478 34 2013 97 rements of Manual 1-4d- 2018-00-31 08:40:04 Right-Suite®Universal201818.0.16RSU08101 Page ...WrightsoftWAC\TREFELNER,TRISTAN&ALEXIS.rup Calc=MJB FrortDoorfaces: W -�- 7rightsoft° Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. UCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fa)c 772-466-6796 Email: QUICKCALCS@/AOL.COM Job: Date: OCTOBER 31, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 2 6.0 ft 10.0 ft heat/cool 6.0 x 9.0 ft 54.0 its BEDROOM 3 19.0 ft 10.0 ft heaNcool 1.0 x 185.0 ft 185.0 ftz y Construction number U-value (BUMEL°F) Or HTM (Btuhlfn Area or perimeter (ft) Load (Btuh) Area (T) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool �- '0 6 11 13A-4ocs 2 glazing; or low-e 2 glazing, or low-e 2glazing, orlorve .2glazing„ddowe- 13A-4ocs 1A-clom 2 glazing, or lowe 2glazing, drlowe 2 glazing, or lowe 2 glazing, dr love 11DO 0.143 0.280 0.280 0.280 0.280.-n__72-4. 0.143 1.270 0.280 0.280 0280 0.280 0.390 n n n n e a a a a a a 4.00 7.84 7.84 7.84 4.00 35.56 7.84 7.84 7.84 7.84 10.92 2.55 8.18 8.18 10.28 10,28, 2.55 91.12 22.46 22.46 9.99 13.11 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 '0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _0 285 0 0 0 180 0 0 4 60 0 6 0 0 0 0 54 0 0 0 0 0 0 216 0 47 0 0 0 0 137 0 135 0 0 0 0 130 0 0 0 18 0 0 112 0 0 0 16 0 0 448 0 0 0 141 0 0 13A-4ocs 2glazing, drlowe 2glazing,.drlowe- 13A-4ocs 106 v 1Aclom 2 glazing, dr lowe 2 glazing, or lowe 2glazing, drlowe 20q;drlow-e -glaa16X19-0m4 2?A-tpl 0.143 0.280 --0280 0.143 0.600 1270 0280 0.280 0.280 0.280 0.408 0.989 s s .-.s_ w w w w w w w r - 4.00 7.84 -7..84 4.00 16.80 35.56 7.84 7.84 7.84 7.84 1.59 27.69 " 2.55 8.18 1028 2.55 12.02 91.12 22.46 22.46 22.46 32.07 1.49 0.00. _ 0 0 , _0 0 0 0 0 0 0 O -_54 54 0 0 0. 0 0 0, 0 0 0 60 0 0 60 0 0 240 0 0. 153 0 0. C : -a 0 0 0 0 0 0 0 54 6 0 0 0 0 0 0 0 - 86 166 0 0 0 0 0 0 0 80 _ 0 0 0 0 0 0 0 0 185 185 0 0 0 0 0 0 0 185 19 0 0 0 0 0 0 0 293 526_ 0 0 0 0 0 0 0 27.5. 0 C F 6 c)1,AEDexwrsion -6 -74 Envelope loss!gain 515 346 1649 818 12 a) Infiltration b) Room %entilation 98 0 26 0 312 0 83 0 13 Intemalgains: Oocupants@ 230 Appliances(lother 0 0 0 1 230 0 Subtotal (lines6to 13) 613 373 1961 1132 14 15 Less e)temal load Less transfer Redistribution Subtotal DUctloads 19% 16% 0 0 0 613 117 0 0 0 373 61 19% 16% 0 0 0 1961 375 0 0 0 1132 185 Total Ait room load required (dm) 731 7 433 21 2336 23 1316 63 ACCAto � � wrigF�tsoT�°^ Right Sute®Uriversa1201818.0.16 RSU08101 ...Wrigttwft WAC%TREFELNER, TMSTAN & ALEXIS.rup Calc= MJ8 FrortDoortaces: W 2018-Oct-31 08:40:04 Page 4 4 1 wrightsoft, Right-M Worksheet Enure House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM Job: Date: OCTOBER 31, 2018 By: 1 2 3 4 5 Room E)posed Room Room Room name well height dimensions area FOYER 9.0 it 10.0 ft heat/000l 1.0 x 145.0 ft 145.0 ft2 GREAT ROOM 16.0 ft 10.0 ft heaV000l 1.0 x 408.0 It 408.0 W Ty Construction number U-value (Btuh/IMF) Or HTM (Btuhtn Area (its or perimeter (ft) Load (Btuh) Area (fF) or perimeter (it) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 4 - _. 13A-4ocs a 2 glazing, dr lowe 2 glazing, drlow-e 2 glazing, dr lowe .2.glazing,drlowe_____ 13A-40cs 1A-L1om 2 glazing, dr Iowe 2 glazing, dr low•e 2 glazing, dr lowe 2 glazing, dr lowe 11D0 0.143 0.280 0.280 0.280 ---0.280. 0.143 1.270 0.280 0.280 0.280 0280 __ 0390 n n n "n _n_ a a a a a a a 4.00 7.84 7.84 7.84 -__7..84 4.00 35.56 7.84 7.84 7.84 7.84 10.92 2.55 8.18 8.18 1026 10.28: 2.55 91.12 22.46 22.46 9.99 13.11 11.31 0 0 0 .0 __ _ _:0_ 90 0 0 0 0 16 21 0 0 0 0 0. 0 0 0 0 0 212 0 0 0 0 125 229 0 0 0 0 0 0 0 0 0 0 0! 0 0 0 -0 0 0 0 0 0 0 0 0- 0 0 0 0. 0 0 0 0 0. 0 0 0 0 0 0 0 53 0 0 0 0 10 21 135 0 0 0 0 210 238 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �i 19A-4ocs 2 glazing, dr lowe 2glazing,.drlow.e__ 13A-4ocs 1013-v 1A-dom 2 glazing, dr lowe 2 glazing, dr lowe 2 glazing, dr lowe 2glazinq,drlowe � 0143 0.280 � 0.280 0.143 0.600 1270 0.280 0.280 0.280 0.280 s s _.s_ w w w w w w w 4.00 7.84 -7.84 4.00 16.80 35.56 7.84 7.84 7.84 7.84 2.55 8.18 1028. 2.55 12.02 91.12 22.46 22.46 22.46 32.07 0 0 0 0 0: 0' 0 0. _ 0 A 0-0-0 0 0 '^ 0 0 _ 0 0 0. _ 0 0 0, F=G L-G _-0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 160 40 0 0 0 16 0 104 40 0 0 0 0 0 416 672 0 0 0 125 0 265 481 0 0 0 359 0 _ C F _ 16X19-0md 22A-tpl 0.408 0.989 - 159 27.69 _ 1.49 0.00 145. 145 145 9 230 249 215 0 408 408 408 16 647_ 443 606 0 6 c)iAED excursion -52 753 \elope loss/gain 1046 746 2304 2465 12 a) Infiltration b) Room \entilation 148 0 40 0 262 0 70 0 13 Intemalgains Oocupants@ 230 Appliances/other 0 0 0 4 920 900 Subtotal (lines6 to 13) 1194 786 2566 4355 14 15 Less rnalload Lesstransfer Redistribution Subtotal DUdloads 19% 16% 0 0 0 1194 228 0 0 0 786 128 190/0 16% 0 0 0 2566 491 0 0 0 4355 710 Total Air room load required (dm) 1422 14 914 441 1301 3057 5065 243 Calculations approved byACCAto meet all i ,= -t}+ wrQghtsoft^ �� - Right-Suite�lUrriversa1201818.0.16RSU08101 Wrightsoft WAC\TREFELNER, TRISTAN & ALEXIS.nQ Calc= MJ8 FrortDoor faces: W 2018-0cl-31 08:40:04 Page 5 - wrightsoft° Right-J® Worksheet Job: Entire House Date: OCTOBER 31, 2018 QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E;Vosed wall Room height Room dimensions Room area DEN 17.0 ft 10.0 ft heaVaDol 13.0 x 11.0 ft 143.0 tt2 POWDER 0 ft 10.0 ft heaUcool 7.0 x 4.0 ft 28.0 fF Ty Construction number U-value (Btuh/ft;°F) Or HTM (BtuhW) Area (ft� or perimeter (ft) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat ' Cool 6 11 1 13A-40cs 2 glazing, or lcw-e 2 glazing, or lowe 2 glazing, or Iowa 2.glazing,_drlowe__-_ 13A-4ocs 1Ac1om 2 glazing, or lowe 2glazing, drlowe 2glazing, drlowe 2glazing, drlowe 11DO - 0,143 0.280 0280 0.280 0.28.0 0.143 1270 0.280 0.280 0.280 0280 0.390 _ n n n n _._n_ a a a a a a a 4.00 7.84 7.84 7.84 -7.84 4.00 35.56 7.84 7.84 7.84 7.84 10.92 2.55 8.18 8.18 10.28 10.28. 2.55 91.12 22.46 22.46 9.99 13,11 11.31 40 0 0 0 -"0 130 0 0 0 18 0 0 40 0 0 0 0 160 0 0 0 0, 102 0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0. _ 0 0 0 0 Q 0 0 0 0 0 0 0 -0 ' '� , 112 0 0 0 16 0 0 448 0 0 0 141 0 0 285 0 0 0 180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 _ �j 13A�ocs 2glazing, drlowe .2 glazing, drlow-e- 13A-40Cs 1013-v 1A-clom 2 glazing, dr lowe 2 glazing, dr lowe 2 glazing, or Iowa 2glazinq,drlow-e 16X19-0md -'- 0:143 0.280 0280 - s s -s_ - 4.00 7.84 -7.84 - 2.55 8:18 ..-1028 0 0 0. 0 0 _--0 0 0 -0, 0 0 ---0 __._._--- 0 0 - --0 0 0 0 0 0 0 0 -i 0 0 - -0 0 0 0 0 0 0 0 ~ 0 0 - 0. 0 __--.0 E-G ! _ C -_ 0.143 0.600 1.270 0.280 0.280 0.280 0.280 0.4.0.8 w w w w w w w ^ 4.00 16.80 35.56 7.84 7.84 7.84 7:84 1.59 27 89 2.55 12.02 91.12 22.46 22.46 22.46 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �32.07 1$9 0 00 -- 143, 143 _ _ 143_ 17 227 471. 213 0 - 28 28 -_28 0 -! 44. 0 - 42 0 _ __, __- 6 C)�AED excursion -53 -3 Envelope loss/gain 1447 727 44 39 12 aj Infiltration b) Room ventilation 279 0 75 0 0 0 0 0 13 Intemalgains: Occupants@ 230 j Applianoes/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 1726 801 44 39 14 15 Lessextemalload Lesstransfer Redistribution Subtotal Dud loads 19% 16% 0 0 0 1726 330 0 0 0 801 131 19% 16% 0 0 0 44 8 0 0 0 39 6 Total room load Air required (cIm) 2056 20 932 45 53 1 45 2 rACCAto meet all rec - wrightsoft� 2018-Oct 31 08.40:04 .4CA -°- Right -Suite® Universal 2018 18.0.16 RSU08101 Page 6 WrigtdsoftHVAC\TREFELNER,TRISTANBALEXIS.n� Calc=MJ8 FrordDoorfaces: W it - - Wrightsoft° Right-M Worksheet Entire House QUICK CALLS, INC. 1 317 ST. �UCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,40L.COM Job: Data: OCTOBER 31, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area PANTRY 0 It 10.0 it heaV000l 6.0 x 4.0 ft 24.0 ft' KITCHEN 15.0 ft 10.0 ft heat/000l 1.0 x 205.0 It 205.0 ft y Construction number U-value (Btuh/ft;°F) Or HTM (BtuhM Area (ft� or perimeter (ft) Load (Bfuh) Area (fP) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs ` 2glazing, drlowe 2glazing, drlowe 2 glazing, dr lowe do lowe___--, 13A-4ocs 1A-c1om 2glazing, drlowe 2glazing, drlowe 2 glazing, dr lowe 2 glazing, dr lowe 11 DO 0,143 0.280 0280 0.280 0280 � n n n n -n_ "� 4.00 7.84 7.84 7.84 -7.84 4.00 35.56 7.84 7.84 7.84 7.84 10.92 _ '- 255 8.18 8.18 10:28 10.28 2.55 91.12 22.46 22.46 9.99 13.11 11_31 - 0 0 0 0 0, 0 0 0 0 0 0 0 ---0 0 0 0 -. � Q. 0 0 0 0 0 0 0 --0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 130 16 0 0 _-.`0 0 0 0 0 0 0 0 114 0 0 0 0 0 0 0 0 0 0 0 456 125 0 0 - -- 0 - 290 131 0 0 _ 0 0 0 0 0 0 0 0 �` ..Zglaang, v 0.143 1270 0.280 0.280 0.280 0280 0.390 a a a a a a a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 INS - 13A4ocs 2 glazing, dr lowe .2glazing,.drlow.e- 13A-4ocs 106-v 1A-c1om 2 glazing, dr low-e 2 glazing, dr lowe 2 glazing, dr lowe 2 glazinq, dr low-e 03ii 0.280 0280 0.143 0.600 1.270 0280 0.280 0.280 0.280 s s _s_ w w w w w w w "' 4.06 7.84 -784 4.00 16.80 35.56 7.84 7.84 7.84 7.84 2.55 8.18 1028: T 0 0 0 0' 0 0. 0 0 0. 0 0 0--0-0 0 0 0 0 0' 0 0. 0 0 V1 2.55 12.02 91.12 22.46 22.46 22.46 32.07 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 20 0 0 0 0 0 0 20 0 0 0 0 0 0 80 0 0 0 0 0 0 ____.0, 51 0 0 0 0 0 0 1 _C F 16X19_Omd 22A 1p1 -0.408 0,989 � `1,59 27.69 _ 1.49 0.00 -24. 24 24 38. � 36 205 205 205 15 325 415 305 0 0 0 0 - 6 c)iAED excursion -2 -175 Envelope loss(gain 38 33 1402 602 12 a)i b)I Infiltration Room ventilation 0 0 0 0 246 0 66 0 13 Internal gains Occupants @ 230 1 , Applianceslother 0 0 0 0 0 2000 Subtotal (lines6 to 13) 38 33 1648 2668 14 15 Less exfemal load Less transfer Redistribution Subtotal Ductloads 19% 16% 0 0 0 38 7 0 0 0 33 5 19% 16% 0 0 0 1648 315 0 0 0 2668 435 Total room load Airrequired (cfm) 45 01 39 2 1964 191 3103 149 of Manual J 8th !f 7Van'!-Ft® "^ " ° "^- - Right Sute®Uriversa1201818.0.16 RSU08101 '`��`...WrightsoftHVAC\TREFELNER,TRISTAN&ALEAS.rup Calc=MJ8 FrontDoorfaces: W' 2018-Oct 31 08:40:04 Page 7 wrightsoft° Right-JO Worksheet Entire House QUICK CALCS, INC., 317 ST. )_UCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax.772-466-6796 Email: QUICKCALCS(, 40L.COM Job: Data: OCTOBER 31, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area DINING 34.0 It 10.0 ft heat/000l 13.0 x 13.0 It 169.0 ftz HALL 0 It 10.0 ft heaftol 15.0 x 4.0 It 60.0 T 1 Ty Construction number U-value (Btith/fELT) Or HTM (Btuh/112) Area or perimeter (ft) Load (Btuh) Area (ftj or perimeter (11) Load (Btrrh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 -J ' -- 13A-4ocs 2 glazing, dr low-e 2 glazing, or low-e 2 glazing, or low-e 2.glaang,drlowe. 13AAocs 1A-:1om 2 glazing, dr low-e 2 glazing, dr lowe 2 glazing, dr low-e 2 glazing, dr low-e 11 DO 0.143 0.280 0.280 0.280 0.280-n- 0.143 1270 0280 0.280 0.280 0.280 0_390 n n n n a a a a a a a 4.00 7.84 7.84 7:84 �7.84 4.00 35.56 7.84 7.84 7.84 7.84 1.0.92 2.55 8.18 8.18 1028 10.28 2.55 91.12 22.46 22.46 9.99 13.11 11.31 130' 0 0 18 Q 0 0 0 0 0 0 0 112 0 0 0 --0, i 448 0 0 141 --0. 285 0 0 185 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0' 0 Q 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A�ois 2glazing, drlow-e .2glaang,.dr.low e_ - 13A-4ocs 106-v IA-c1om 2 glazing, dr low-e 2glazing, drlowe 2 glazing, or low-e 2 glazing, or low-e 0.143 0280 0280 0.143 0.600 1270 0280 0.280 0.280 0.280 s s -s_ w w w w w w w 4.00 7.84 -7..84 4.00 16.80 35.56 7.84 7.84 7.84 7.84 rt 2.55 8.18 -1028. 2.55 12.02 91.12 22.46 22.46 22.46 32.07 80 0 18: 130 0 0 0 0 0 54 '� 62 0 18, 248 0 141. 158 0 185 193 0 0 0 0 0 1732 0- 0 0 0 0 0 0 0 0 0 0 0 0 ' 0 0 0. 0 0 0. ` w 11 76 0 0 0 0 0 0 304 0 0 0 0 0 423 0 0 0 0 0 0 0 0 0 0 0 0 0 -_ 0 0 0 0 0 0 0 0 -G - C>_ Fy_ 16X1&Omd 22A tpI 0408 0 989 - 1.59 27.69 1,49 0.00 - 169, 169 169 34 268' 942 251 0 60 60 60 0 95 0 89 0 -- - - - 7- - 6 c)IAED excursion 546 5 Envelope loss/gain 2916 3535 95 84 12 a)1 Infiltration b); Room ventilation 558 0 149 0 0 0 0 0 13 Internal gains Oooupants@ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 3474 3684 95 84 14 15 Lessextemalload Less transfer Redistribution Stbtotal Dudloads 19% 16% 0 0 0 3474 664 0 0 0 3684 601 19% 16% 0 0 0 95 18 0 0 0 84 14 Total room load Airrequired (dm) 4138 40 4285 206 113 1 97 5 all requirements of Manual J 8th Ed. {� wrigF_tts_ofe® 2018-Oct-31 08:40:04 AC- Riga t-Sate®Uriversal 201818.0.16 RS U08101 Page 8 Wrightsoft HVACITREFELNER, TRISTAN & ALEXIS.rup Calc= MJ8 FrortDoorfaces: W ivrightsoft° Right-JO Worksheet Job: Entire House Date: OCTOBER 31, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 koom name Exposed wall Room height Room dimensions Room area ENTRY 23.0 ft 10.0 ft heat/000l 16.0 x 7.0 ft 112.0 fP LAUNDRY 25.0 ft 10.0 ft heaVcool 16.0 x 9.0 ft 144.0 fl? Ty Construction number U-value (BtuhfiF-F) Or HTM (Btuh/M Area or perimeter (ft) Load (Btuh) Area (T) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 - 90 8 0 0 160 18 0 0 0 0 _ 0 82 0 0 0 --- 0 142 0 0 0 0 0 0 -328 63 0 0 0- 209 65 0 0 ----Q 361 1640 0 0 0 0 0 W 13A-4ocs 2 glazing, dr lowe 2 glazing, dr lowe 2 glazing, cir Iowa 2.glazing, drlow�e_.- 13A-40cs 1A•clom 2 glazing, dr lowe 2 glazing, dr lowe 2glazing, drlowe 2 glazing, dr low-e 11DO 0:143 0.280 0.280 0280 0.280 0.143 1270 0.280 0.280 0280 0.280 0,390 n n n n -n_ a a a a a a 4.00 7.84 7.84 7.84 --7.84 4.00 35.56 7.84 7.84 7.84 7.84 - 10_92 4.00 7.84 -.-7..8.4 4.00 16.80 35.56 7.84 7.84 7.84 7.84 1.59 2.55 8.18 8.18 10.28 _ 10.28- 2.55 91.12 22.46 22.46 9.99 13.11 11.31_ - 70 0 24 0 _•_---0- 0 0 0 0 0 0 -- 48 0 0 0 ---0- 0 0 0 0 0 0 0 184 0 188 0 -0 0 0 0 0 0 0 0 117 0 196 0 --_-0 0 0 0 0 0 0 0 � _ 569 640 0 0 0 0 _ 0 �j -. 13A-4ocs - 2 glazing, or low-e 2glazing, drlowe_--_ 13A-4ocs 1013-v 1A-c1om 2 glazing, dr lowe 2 glazing, dr lowe 2 glazing, or lowe 2.q a# q, dr lowe 16X19 Oms 22Atpl - 0.143 0.280 -_ -0.280 0.143 0.600 1.270 0.280 0.280 0.280 0.280 w0408 0989 -e s s _.s__ w w w w w w w T =_ 2.55 8.18 -1028. 2.55 12.02 91.12 22.46 22.46 22.46 32.07 1.49 -0 0 0 0. 160 0 16 0 0 0 0 -____ 0 0 -0. 144 0 0 0 0 0 0 -_ 0 0 _Q 577 0 569 0 0 0 0 _- 0 0 _ 0 367 0 1458 0 0 0 0 0 0 --0 0 0 0 0 0 0 0 0- 0 __ 0 0 0 0 0 0 0 0 0 0 -0. 0 0 -_ -0. I-G 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ C - y_ - 112 -T112 112 23 178.' 166 0 144 -_ _ 144 25 22- 692 _- --_214- _--0 0_00 _27.69 .- __-637 -_ ,144 -T-- - - - - - - - - - 7.Z. - ---- V -- _ - _-__ --- -� -- -- -- - - -- - 6 C) �ED e)=rsion 431 -5 Envelope loss/gain 2332 2735 2520 2485 12 a)i Infiltration b) Room ventilation 377 0 101 0 410 0 110 0 13 Internal gains Ooajpants@ 230 Applianceslother 0 0 0 0 0 0 Subtotal (lines 6 to 13) 2710 2836 2930 2595 14 15 Lelssextemalload Lesstransfer Redistribution Subtotal Duldloads 19% 16% 0 0 0 2710 518 0 0 0 2836 462 19% 16% 0 0 0 2930 561 0 0 0 2595 423 Total room load Air, required (cfm) 3228 311 3298 159 3491 34 3018 145 /ACCAto meet all requirements of Manual J I ••FW 2018-Oct-31 08:40:04 Right SUteOUrrversal201818.0.16 RSU08101 Page 9 AOC'% I..WrightsoftWAMTREFELNER,TRISTAN&ALEXIS.rup Calc=MJ8 FrortDoorfaces: W i wrightsoft® Duct System Summary Entire House QUICK CALCS, INC. 317 ST{ LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,40L.COM For. TRISTEN &ALEXIS TREFELNER SLASH PINE TRAIL, ST. LUCIE COUNTY, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowestfriction rate Actual airflow Total eifective length (TEL) Heating 0.50 in H2O 0 'in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.080 in/100ft 318 cfm 207 ft Job: Date: OCTOBER 31, 2018 By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.080 i n/100ft 1383 cfm Name Design (Btuh) Htg (cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH2 c 433 7 21 0.080 4.0 Ox0 ShMt 27.4 130.0 st3 BEDROOM 1 c 2125 24 102 0.080 8.0 Ox 0 ShMt 37.0 165.0 st3 BEDROOM c 2013 34 97 0.080 7.0 Ox0 ShMt 42.1 165.0 st3 BEDROOM c 1316 23 63 0.080 7.0 Ox0 ShMt 28.0 130.0 st3 DEN c 932 20 45 0.080 7.0 Ox 0 ShMt 18.0 130.0 st2 DINING c 4285 40 206 0.080 8.0 Ox 0 ShMt 24.7 130.0 st1 ENTRY c 3298 31 159 0.080 7.0 Ox 0 ShMt 24.7 130.0 st2 FOYER c 914 14 44 0.080 5.0 Ox 0 ShMt 37.4 130.0 st3 GREA I ROOM c 2533 15 122 0.080 7.0 Ox 0 ShMt 25.5 130.0 st1 GREATIROOM-A c 2533 15 122 0.080 7.0 Ox0 ShMt 27.8 130.0 st1 HALL c 97 1 5 0.080 4.0 Ox 0 ShMt 0 0 KITCHEN c 3103 19 149 0.080 8.0 Ox 0 ShMt 25.4 130.0 st1 LAUNDRY c 3018 34 145 0.080 7.0 Ox 0 ShMt 24.0 130.0 st2 MASTER BATH c 1862 37 89 0.080 6.0 OxO ShMt 40.2 165.0 st3 PANTRY c 39 0 2 0.080 4.0 Ox 0 ShMt 13.9 130.0 st2 POWDER c 45 1 2 0.080 4.0 Ox 0 ShMt 17.0 130.0 st2 TLT c 29 0 1 0.080 4.0 Ox 0 ShMt 35.5 165.0 st3 WIC c 198 2 10 0.080 4.0 Ox 0 ShMt 35.5 165.0 st3 * wrightsoft® 2018-Oct-31 08.40:05 Pigtt-SUte®Uriversal20l8l8.0.16RSU08101 Pagel ACCA..WrightsoftHVACITREFELNER,TRISTAN&ALEXIS.W Calc=MJ8 Front Door faces: W Trunk Htg Clg Design Veloc Diann H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 PeakAVF 141 427 0.080 648 11.0 0 x 0 ShtMelt st2 PeakAVF 86 352 0.080 646 10.0 0 x 0 ShtMetl st1 PeakAVF 89 599 0.080 762 12.0 0 x 0 ShtMetl Grille Htg Clg TEL Design Wloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (ch) (ft) FR (fpm) (in) (in) Opening (in) Mat Trunk rb1 Ox 0 318 1383 0 0 0 0 Ox 0 ShMt nrightsoft® ^�. ,.�•��.,�.•.ww.,�P•, RigYt-Sute®Uriversa1201818.0.16RSU08101 ' WrightsoftHVACUREFELNER,TRISTAN&ALEXIS.nQ Calc=MJ8 FrordDoor faces: W 2018-Od-31 08:40:05 Page 2