HomeMy WebLinkAboutREVISION - ENERGY EFFICIENCY CODE1', - i f�' FORM R405-2o97 •.. r 'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method RVAI FcEher flame:: Muse aesidence Builder t�lair'SCANNte: Glenn (',4use 5821'Mustange Cir Farmit Office:,Stafa, Zip: Port St.Lucie, FL 34987 Pemvt Number_ Muse Residence Jurisdiction: St Lucie Lucie Qlan� Design Location FL, St Lucie Co IntlSt Caurrty St Lucie (Florida Climate Zone 2) 1. New construction or einsffng New (From Plans) 9. Wail typees (2607 ft-) Insulation (R) Area (112) 2. Single family or multiple family. Single Farritly a. Blk wall, stuom e4 r-5 eAbd 5.0 2347-42 3. Plumber of units. if multiple femiry. 1 b.- Fm1 wal1,10 gyp.bd ext, c 11 11.0 260.00' cw NIA 4- Number of bedrooms. 3 d. WA 5. is tills a worst case? No 10. Ceiling types (2451,ft� Insulation (R) Area ft I 6. CarodWDMd floor area abovegrade (ff2) 2450.63 b: Attic ceiling, roll roaf, r�0 ro 0.0 2450 63 NIA Conditioned floor area below grade (W) 0 a NIA 7. V4fndows 175 11. Duds ( ftz) DbI ImpaM Area (7 a.s,.p: �oMt, Rat HoeteA5c;AN; (Unoor�eeradjltk R Area ( 0 a. tl�aclor. Dbl Impact, i.040 3i1.27 6.0 Q_p0 SHGC: 029 b. b. U-Factor. 12. Coorri !SHGC: 9 kBtulhr Effidency a.Splitairconditioner 45.0 SEER:16.0 c. U-Factor, f f b_ f f ,SHGC: 13. Heating -systems kBtufhr Efficiency d. U-Factor a.Electric strip 38.1 AFUE:100.0 SHGC: b. Area Weighted Average Overhang Depth: 1_aW ft 14. Hot water systems Area Weighted Average SHGC_ 0290 a.E[ectrfc conventional (40 gal) Cap: 40 gal EF: 0.99 8. Floor, types (2450,63 ff) Insulation (R) Area (W) b.Conservation features a. On grade depth. the flrfnsh 0.0 2450.63 (None) b. NIA C. WA 15. Credits Ceiling Fan f Glassl,Ftoor area: 0.071 Total Proposed Modified Loads: 65.24 _ SS Total Baseline Loads: 65.31 �� l hereby certify that plans and cifications coveted b Review of the plaits and speciffca#lolls this calculation are 47 cornpli v�itii orida Fn covered by this calculation indicates C� itIEST�7 Code. !� mplianca vrith the Florida Energy,' - ao e. Before construction is completed; 'PREPAREDBY: f s building mill be inspected for mpiiance with Section 553.908 DATA: 121041019 Florida Statutes. 0 I hereby certify that this building, as designed, is in%fc compliance with the F tla Energy ode, Op H.E-� OWNERIAGEN AA BUILDING OFFICIAIL DATE: l (i, MI I q BATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation raspeefion Checkrist in accordance with R402A.1.1 and this project refit ires an envelope leakage lest report with envelope reakage no greater than 3.1 ACH50 (R402AA 2). Trite cop y :� �i`Vl -�'. Vzt(z, - V i ._._.:T-:i�._.a.,-s'+Yct�*bR'-:?"C.' -i:• __:.__... ...._. .. _ .:..✓'.°i: :ra .1C::fs=3F='7.Y:i _"^._ 20101"1224,43 RikTl9ommenL'MKoMxg FNACVAuseRaenc 4p ceft= MJa F toorfac n! n7 SWon 4Q6.4.9 CoajpEsnt Sarbnlre Page 2 V 4., D 00000920000000000 -1 f�0o z =1:) :'. = ca 121 X rorommcucumsorororrmroro 0, CCD21 L 0 05, .,U30:,WC.)W0"0 0 Q 9 5j 03 60, Mt tt�=nmm =F'r mm'mm (D C) nFD' g mc: 00 (1) =(D CL r.L im -Mto UIC3CA D) 00 FRI �4VI 0 a] WNNSWM�4— Q) pcn000 =M -00000 ro C6 0 .0 Era — am E-44 Lm 0 co a"O rj CD OR CQ(a X co wtptoo tHo-Imao n . . . . . . . . . . . fD 0 OC) 0 1— 0 (a 171 — ;P= >0 0 0 0 0 4 :L .1 m oozzoz—www -40-40 000�4%'Ow""Q�4 ro ox 4D r.4 cr ;To* Q00100000000000000 CD CL O pp roV 009 J;! 84NOWdWMOAt3eN8i =1 (D ——------ nI4 c zz '—% i;VR 11=MS a 0* WOW i CD CD W. UU.0 NQ9bgyp. r.9 W 'n 7 00 m co , =r (D CL FT P m zz 6.< *rA ge M NfII 9 L49 (VU) 490 CA Q. 4 cc:) cx 00 0 to 4 O Pm P.m CL on"* Derry Pik Cl) (D V 0 I' 00 anaavQotsQ�oSo QO�tsp C7gp000Q00000 QOO i3OUOO �` S S7 � OOOOOOOOOo40000G05�0000 e O a o00000000000 ,-Ngg� gn3-J O Ny OOOO000 �S�S mL7 77 000000000000 is r• C? N�lt�t?RttNufu�iLL7N K34]Nzl}Nln Nti?zl7N 1plflNu7 I�hhh[�h1I�Rl�fg{�hf�hfrYtihfdht+h F.r O apyy u7�t �f94'io:i��PJ��tf7�7k � °4i N a N II (n OCD000©GOOC�CGOCiGGOOOOCO II �C L b 'O DVMti'0WITOO M ld 1C qJ G V) c S� A r.5 C C C C. @�CflfamtDW`t`! O LL OQOddOAd000000000 PTTYI: r`t—TrrrrrTPPP N �' i "�� Ni`i{*IN5`N1NC t`NS(V C+ q pp0000000fJO00000p0 �I C O 5 6CGGCC CCC of Q T M U U (�+ 1 4 ru a7 coticio®acici®c©oRi000 O d y "j'.. rnr.e.mnwcarnm�y rn rnmmommmmom mmmM;4m@mof�ry r� �f Q�rnmmrnc�mm a {f7 fa t3)Q ocioppooafaoo CCd�� +GbCd a 0 Q tg LL O'QOoo0oOd00[7�000Oo�00 6O OC3000GOC70000ij0CJOOC7R]CL �Gq d NNNNNNNNNNNN �V9 =CCGCC CCGCG � }a o L AAO©0000000 O ♦Y � .� �p N IOO�t701Ji000MQt�Clpp �Nt�i[DI��hOtn�u�i[100,...L,,,7[CCS 0 f¢ dA � � AQQ�O�f74?47�ti �tl lt)4'�474�4}�C1 c7?KTtO In 1A � t�6 O rrrt-rr r--wr*e- � � .�' � i`; CI[OROW�79I�4i y O p 1ti q+ � ©©0190�IJ0000'vrOtp0000 pOQ 00 NO1!�1t�6t� f*S!Q Am ONomOOOOlAt1?OO +i@'(� `� etCSN COOED In1q(O t4tOf0 Mcrt M rM r'-r �j. Q 7 W 7� pj a NN tOMC�.?fD AiM*'CdvvoavmP t07�1014'V' r � t[} rr T T'Ne+ NT cq o zrh�ii�CDLCJ4SN�i}NN po 0 ppo C Aood0000000pp000000Aoogoa�ays`C+cia`�C�`a�'et E ----rrr�a C � VQ'oo 'y `Tt1;`�Y��1;V;V; 440000®0000000@pq =Gy o oac? o4 O� AAObddo00NNN Pt-rrrPrrT`a�rre-z-r+rTTPTTr � N Q . (, r iJ) �Arct�t��asuearp��so�a44prntoocom � .0 c°firyn°iM� N IN�rn`l�" � R 4> RW' QO ...[ � � aLL CfltgCPO R�apMt"'WVYWvmt+N.q--m�r�•rN Fr r r•4 r 34 �' � O 000 OR70000A U' � aq7 � p W V 000Q4D04 QA000000o r' Uy0000r6, 0t�0t�0a�+4+�{00 'Q •--� it! 2 R N Op ppr 4 4 000 0 6059 0 0000000 k G� OOG4� LL L T rrrrr.-rc-Try-r Q z ,�,� Go � L�--O cawNcg@MM SUs'cy �Wk C-4 Jt"p7MMia0N UMtcC0r'_pGc�qc_per2�"a. S t v ti O � C13 a� �w� �uvv o aoC spon—q.n >-?-i•s-Y?°�2?>?aYa ' py `t�U 5gymmmcnm va A 5 r-..-.w�-..-�.....r...ir..ww�w O0O 00Q00060 Nocloon 0 R;z dl �— �O•LOt%fOD],,Op� Odf8?3A0J0?a0A�02 fJ R0r2aa0 0cx: CH NNNiYNNNNNNNNNN - D7rTgJ�`YINxA�i1'ItANNYIiMNyNNU7yiA c`— -®=--=—==----Wp `,.r�• ry I1. WWW1UU1WWIl W T�� -! L LL L4•L. V♦tVbLtixW ljL w.^.r�-e25 mi}}16--�—s �eN��\�V�$^} } �• ,5,? > $, �' y O 1U 000 QOSOp 000Q ���� �` �� 9C��SC€�CSG SGYYLY 2.S�X.l_C SCSC 5�3G.Y D ❑ m Riff 33 EEEEEEEEE aE BE BE �ll.lE.UajyCGWCGA7iD@@@'17C��1i7�lilCO0in0� O ,� — Qq'.fJ1 G7L727i070rOl Of OfL� 04b1 C7 G 6 G G C C G C C �G � ��.� � � C C C r.. z- +-ti Lt •- t_ C� ty� U .S.0 r^..�mze=l n_'i e_aS L4's°3�'ci�cciUsac7o,°is• ay �6.F- �, w. t., �. a. �. 1.. � � � �. 9Qo o�ccc�cc�ge r�oc.�c 0000 ��e �O_ r�}f49�C}iDrrTTPiV �.O�.i t� 0 0 xe X��s1.1111LIIlLIIuJWIl7'S1tL4lIi,IIWWLL1 MUM ¢dr"4a¢aa�ed S p cnwwus}}Ww z� >? z a3 - o 0 a) W r uatiiaJz�lllU)a]zzzaiii}? qE rN qk rN47 iY U'I tOI�W C7�rpeNTrY �r � rRYf'7th U5fOP�C80sOrN�tt 4')60hQP6lo TN_ r.--rr.mr-NNN _ xk_ rNMet�131[1t�00m�a=N- - q� r - - — - __No�--___ CY 3 O mp Np 0 c Fm I C/IDRA MATT nmq-, I HEATING SYSTEM System Type Subtype Efficiency Capacity Black Ducts i 1 Electrlo stdo AFUE:100.0 38.1 kBtu/hr 1 s s#1 COOLING SYSTEM f # .SysternTxe Sub a Eflicten Ca aci Air Fiow SHF2 8locic Ducts 1Split air conditioner SEER.16.0 45.0 kBtuthr 1500 cfm 0.70 1 sys#1 , HOT WATER SYSTEM # System Type Subtype Location EF Gap Use Setpnt Conservation 1 Electric oonventional 0.99 d0 gal 60 gal 120 T None OUSTS # Supply -- --b Return Air CPM 25 Percent HVAC # Lo0ation R-Value Area Location Area Leakage Type Handler Out Leakage ON RLF Heat Cool a House Attic 6.0 Oft= House Attic 0ft2 o-q-nu&akaqm (unacnd-jDncd)Aurc(pefaulq 6.00 1 1 TEMPERATURES Programmable Thermostat Y Cefling Fans: Cooling X ]Jan Heating X Jan [ X1 Feb °[ X] Mar [ X Feb [ X (star [ X1 Apr [ X1 May [ X] Jun [ X] Jul [ [ X] Apr j X] May X Jun X1 JW X] Aug [ X] Sep [ X ] Clot X] Nov [ X] Dec Aug Ventin X Jan X Feb X Mar [ [XI X Apr X] May Jun [ X] Jul [XI [ X] Sep [ X] Oct X Aug-[ X S[ ep [XI1XI ©ct X Nov [ X] q2x—Lzj Dec Dec Thermostat Schedule: Florida Building Code, 6th EdiVon Hours Schodute type {291 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 1 PM 75 175 75 75 75 f. 75 75 75 f 75 75 75 7% Cooling (VVEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 I PM 75 75 75 75 75 75 75 7$ 75 75 75 75 Heating (WO) AM 72 72 72 72 72 72. 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating (WEH) APA 72 72 72 72 72 72 72 72 72 72 72 72 Pbt 72 72 72 72 72 72 72 72 72 72 72 72 I � I wrl i htsoW 'RFgryt.SU1to&.Unir" 201919.0.13 RSU27054 Rt ht•En'e O Frorfdj 2017 S?ctlon daS.tLr Ca 2019-De�4IZ,34:43 �.�-we-.„::w kllQorumenlslL�Alght�BiNAG"1NuxCResidcrceo.rcrp (ata=Mtb Fromr?oarrstxs Ct. tant5oflwaro p eS q I I k IMORM R405-2017 ENERGY PERFORMANCE LEVEL.(EpL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE- INDEX =100 The lower the EnergyPerformance Index, the more efficient the home. i 1. Nlew home or addition 2. Single-family or multiple -family 3. Number of units, if mui6ple-family 4. Number of bedrooms 5. Is this a worst case?.(yesfno) i 6. Conditioned floor area (frj 7. *dows, type and area a. P-Factor. b. Solar Heat Gain Coefficient (SHGC): a area (w) 1. New (From Plans) 12. ducts, location & insulation level a. Supply ducts: R 2. --SWote-Family b. Return ducts: R c. AHU location: (Unconditiont}d) Atiic 3• 1 4. 13. Cooling systems Capacity, 45,0 3 a. Split system: SEER 16.00 b. Single package: SEER 5• No c. Groundhvater source:. SEER/COP A. Room un!UPTAC: EER 6. 2450.63 e., Other 7aDbl Impact: 1.040 7b. 0.29 7c. 311.27 . 8. SIry',Gghts a. U-Factor: ga. b. Solar Heft Gain Coefficient (SHGC):r 8b. t 9. Floor type, insulation level a. Slab -on -grade (R-value): b. Wood, raised (R-value): c: Concrete, raised (R value) 10 Wahl We and insulation: a. Exterior: I. Wood frame (insulation R-value): 2. Masonry (Insulation 11 value): b_ Adjacent: 1. Wood frame (Insulation R value): 2. Masonry (Insulation Revalue): 11_ Ceiling type and insulation level 9a. 0.0 9b. 8c. 10a1 _ 10a2. 5 10b1. 11 10b2. a. Under attic (R-value): 11a_ p,D b. Single assembly (R-value)_ 116. c, Knee walls/skylight walls (R-value) 11c. d. Radiant barrier installed 11d. 14. Heating systems Capacity. 38.1 a- Split system heat pump: HSPF b. Single package heat pump: HSPF c. Electric resistance: COP 100.00 d. Cas furnace, natural gas: AFIUE e. Gas furnace, LPG: AFUE f Other. f, 15. Water heating systems a. Electric resistance: EF 0.990 b. Gas Fired, natuual gas: EF c. Gas fired, LPG: EF d. Solar system with'tank: EF e. Dedicated (teat pump with tank: EF f. Heat recovery unit HeatRec% g. Other. 16: HVAC credits claimed (Performance Method) a. Ceiling fans: yes b. Cross ventilation: c. Whole house fan:. d. Multizone cooling credite, Multizone heating Credit: f. Programmable thermostat Yes. "Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT- 1 certify drat this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features whicKvidil be installed (or exceeded) in this home before final inspection. Otherwise, a new IEPL Display Cardwiq be completed based on installed Code compliant features. Builder iSignature:8NI�L.dater 5 I AA Address of New 'HoJ e: _5821 Mustange Cir CiLijlFl, Zip;. Port St Lucie, FL 34987 I ' "wPagI7t Clilt- Ri9msuittzUnivar,a12D19ie,t).13Rstr27D54 F2fght-!A01ra �.F[a=irts2ot7 Sedan4�a.#7C p�ant$ott tcSFQea04i234A3 ...Edi OcmeMaVftigktco:tWACLMuseResider=,rup (its=Cutt3 fruitt?4Cffaws: N Pap N I FORM € 405-2017 Florida Building Coda, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods 5821 Mustange Cir PERMIT P MA1NDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL I I Q R401.3 Energy Portormanee Level (EPL) display card (Mandatory). The building ofitcial shall require that an energy performance level (EPL) display card tie completed and certified b the builder to be accurate and correct k4etore final approval of the building for occupancy. Florida flaw edion 553.9085, Florida Statues} requiros ltie EPL display card to be included as en addendum to each sates contract for both presald and nonp i S Id residenCral buildings. The EPL display card cotrtains rnfprrrnation indicating the energy performance level and %pRd lesofeompanents installedadwellingunitcompleteansignebythe budder The bulldir>g offidal shall verily ihat the EPL displaycardelyreflectstheplans apecificationbmltt@d W demonslra[e compliance forthe building. A Dopy of the EPL display qrd can befound in ix RD; _ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4,1 through R462.45._ i E Kce lion• Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to oompfy with Section C402.5. R4tl2 A Building thermal envelope. The building thermal envelope shall comply with Sections R402AA A and R402.4.1.2. The sealing meFiods between dissimlar materials shall allow for OfferenUal expansion and contraction. R4i)2A.1.1 installation. The components of the building thermal envelope as listed to Table R402.4,1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as app%able to the method of construction. Where required by ti he code official, an approved third party shalt inspect an components and verify compliance.. R462.4.1.2 Testing. The budding or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through S. Testing shall be conducted in accordance with ANSURESEUCC 380 and reported at a pressure of 0.2 inch v. g. (50 Pascals). Testing shag be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(0. (g), or c) or an approved third party_ A Written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shag be performed at any time after creation of all penetrations of the building thermal envelope. Exce fionr Testing is not required for additions, alterations, renovations, or repairs, of the bUi Ong thermal envelope of existing buildiir qs in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1 _ Exterior vAndows and doors, fireplace and stove doors shall be closed, but not seared, beyond the intender[ i Vieatherstrippirtg or other infiltration control measures. I 2. Dampers inc ud g exhaust, Intake, makeup air, backdraft and flue dampers shall he closed, but not sealed beyond intvWtd inflttration controt measures, 3. interior doors, if installed at the time of the teat, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and returnregisters, if installed at the time of the lest, shall be fully open. i R402.i12 Fireplace.. Now wood -burning firepraces shad have tight -fitting flue dampers or doors, and outdoor combustion.air_ Where Using tight -fitting doors on factar)r-bugt fireplaces listed and labeledin accordance viith UL 127, the doors shall be tested and listed for the fireplace. Where using tight -rigging doors an masonry fireptacesthe doors shag be listed and labeled In accordance with UL.907. i Ef R402.4.3 Fenestration air leakage. Window, Skylights and sliding glass doors shag have an air infiltration rate of no more than 0.3 cfm per asquare foot (1.5 Uslm2), and sWng'mg doors no more than 0.5 cfrn per square foot (2.6 Uslm2), when tested according to NFRC 400 or MAIWDMAICSA 10 ILS.21A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. i acQpfion: Site built trrindoays, skytigtnts and doors. I i wir,ighfsofik'° hrght•S.UftO Urgve«sa120191g.0.13 RSU27Q54 ftht-Ene..WZ FJmWa 2017 Sacbon4i)54,1 CompliaidSolhvane0 Ptm kilDoaimentslArggh:;oltfiVACVdusoResidence up Coale=rrJB FmntDmrfacem N 4 'I FQRMI R405-2017 M4NDATORY REQUIREMENTS - (Continued) Q R40Z4.4 Rooms containing fuel -burning appuances In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuol burning appliances, the appliances and combustion afr opening shaA be located outside the building thermal envelope Or enclosed in a roam isolated from ins'�e the thermal enveto e. Such rooms shall be Sealed and insulated in accordance with rite envelope requlrem rite of Table R402.1.2 vfiere the walls, floors and ceTngs shammeet not less than the basement wail R-ualue_ requaremen# The door into the room shalbe fully gasketed and any wafer f1neS and ducts in the room insulated in accardancevrtih Section RA03. The Combustion air duct shall be insulated where it Wises lhreu h conditioned Spam to a minimum of R:B. Exceptions: 1. Direct'vent apliances with both intake and exhaust pipes-instagod continuous to the outside. 2. Fireplaces and sloven complying with Section R402.4.2 and Section RIM of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to Unlit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall to IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shali be sealed with a gasket or caugc betvieen the housing and the interior wail or ceiling covering. SECTION R403 SYSTEMS Q R403,1 Controls R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall ire provided for each separate heating and cooling system.. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during efrost. prevent supplemental heat operation when the beat pump compressor can meet the heating load. r R403.3.2 Sealing (Mandatory). All ducts, air handlers, triter boxes -and building cavities that form the primary air containment passageways for, air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C4032.9.2 of the Commercial Provisions of this code and shall be shovm to meet duct tightness Criteria belmv, Duct tightness shall be verified by testing in accordance with ANSYRESNET/ICC 380 by either individuals as defined in Section 553,993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489,105(3)(9, (g), or (i), Rorida Statutes, to be "Substantially leak free In accordance with Section R403.3.3. 11403.3.21 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested In accordance frith ASHRAE 193. I 11 03.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the follching methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, ineludin the manufacturer's air handier enclosure If installed at Me fire of the test. All registers shall be taped or olherwuse seated during true test. 2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch vi.g, (25 Pa) across the entire system, including the manufacturer'. 's air handler enclosure. Ali registers shall be loped or olhervnse seated during the test. Exceptions: 1. A duct leakage test Shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ® R4D3.3.5 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Niachanicatsystem piping capable of carrying fluids above 105`F (41'C) or below 55°F (13°C) shall be insulated to a rrrrinnh um of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shali be protected from damage, including that caused �y sunlight, moisture, equipment maintonance, and wind, and Shan provide shielding from solar radiation that can cause degradation of the material, Adhesive tape shall not be permitted, Q R40341 Heated water circulation and temperature maintenance systems (Mandatory). . Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat7trace temrperature maintenance systems shall be in accordance with Section R403.5,1,2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water Circulation systems shall be provided vrith a circulation, pump. The system return pipe shall be dedicated (alum pipe Ora cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited - Controls for circulating hot water system primps shag start the pump based on the idenliiicattpn of demand for how water within the occupancy. The controls shall aufomatically turn off the pump when Me water in the circulation loop is at the desired temperature and when there is no demand for hot water. I i R403.541.2Hoat trace stems. Electric heat trace systems shall comply Huth IEEE 515.1 or UL 515. Controls for such systems Shall automatically adjust the energy input to the heat -tracing to maintain thee desired water temperature In the piping in accordance vriih the times when heated "water is used in the occupancy. II I . wa'ightSC) t' g 2mDl[94k�-as 112:34:a3 " Ri ht-Suitef,�.t7nvcisal2Dt yB�.73.RSU27054 flight-EMsW0 Florkia2017 Seaft'�4o5.4.1 CoMp&W:Sofhvane Pollee kiftWnx�tsll4Pzi;hisofHVACV,iuseResidenoemp Caicrat.7J3 Front Doorft= N t` .. -.. ,. ._ , 1,�'. �- ._. FORM lR405-2017 MANDATORY REQUIREMENTS - (Continued) i - R403.5.5 Heat,traps (Mandatory). Storage wrater heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External beat traps shall consist of either a commercially available heat (rap or a i dC,vnward and upward bend of at least 3 112 inches (89 rim) in the hot water distribution Fine and cold seater line located as close as possible to the storage tank. El g4. 03.5.6 Water heater efficiencies (Mandatory). R03.5_6A Storage crater heater temperature controls. ® R403.6.6.1.1 Automatic controls. Service viater heating systems shall be equipped with automatic temperature Controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 1 DVF to 140°F (38'C to 6M. ® R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall bo provided to permit the energy supplied to the main bumer(s) of combustion types of service water heating system to be ttrmed oft ! [3 R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C4042 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions. for the type of equi ment installed, Equipment used to provide heating functions as part of a combination system shall satisfy all stated requireme%for the appropriate water heating category. Solar water heaters shalt met the criteria of Section R403.5,6,2.1. LI R403.5.6.2.1 Solar water heating system. Solar systems for domestic hot Crater production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shalt be tested In accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic, Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria. 1: Be installed with a tilt angle betty wri 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation vdthin 45 degrees of true south. 0 R463.6 Mechanical.ventilation (Mandatory). The building shall be provided vr'ith.ventr7ation that meets the requirements of the Florida Buitdlr�q Code, Residential or Florida Building Code, Mechanleal. as applicable, or wi(h outer approved means of ventilation, Including: Natural, tnpliltration or Mechanical means_ lOutdoor air intakes and exhausts shalt have automatic or gr�vftyldampers that close viben tho veratiiatiofr system is rat operating. 0 R403.6.1 Whole -house mechanical ventilation system fan offlcacy. When installed to function as a vhiole house mechanical ventilation system, fans shall meet the efficacy rgLdrements of Table R403.6.1. Exception; Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor, R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shalt meet the follevring criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 02.2, Ventilation for Acceptable Indoor Air Quality, shall be (he maximum rates allows for residential applications. 2. No ventilation or air-conditioning system make- air shall be provided to oonditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to sv4mming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air.is drawn shall be insulated to a minimum of R711 and the ceiling shall be insulated to a minimum or R 19, space permitting, or R•10 otherwise_ ® R403.7 Heating and cooling equipment (Mandatory).. E] R4R&7.1 Equipment sizing. Heating and coetiT egiu'pment shall he sized in accardance •.with ACCA Manual S based on the equipment loads Calculated in accordance with A CA Manual J or other approved methodologies, heating and cooling calculation based on buildir:4 loads for the directional orientation of the building - The manufadurer and model number of the outdoor and Indoor units (it split system) shall be submitted alongwith the sent i�le and total 000ling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizin calcutations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal raw for the geographic location where the equipment Is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM MINIMUM EFFICACY (a) CFMIWATT AIRFLOW RATE MAXIMUM CFM Flange hoods Any 2.8 cfmAvatt Any I In-Iinelfan Any 2.8 cfmfwatt Any Bathroom, utility room 10 1.4 cfmAvatt < 90 Sathrdom, utility room so 2.8 cfmhriatt. Any For SI: 1 efm - 28.3 Uritin. (a) When tested in accordance HVI.Standard 916 20i B,Deo-e4 12:34A3 welgfltSow RightSuiteO UnivCra1 2014.19�.0.13 RSU27£�d Wgal.Enerpje Florida 2017 SodionQ5.4.1 Corrpllant,Sa`tware age 9 • e .,,. �..+ .v_.[�100-w-r:sANrlghiOELHVAWAF-eRetsQCnMrvp Cris=MJ8 tic Dvorfata N MANDATORY REQUIREMENTS -(Continued) ued) R403.7.1.1 Cooling equipm®nt capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greaterlhan the total toad calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product Enes. The corresponding talent capacity of the equipment shalt not be less than the calculated latent toad. I The published value for AFRitotal capacity is a nominal, rating -test value and shg not be used for equipment sizing. Manufacturer's expanded performance data"shall be used to select coating -an equipment. This selection shall be based on the outdoor design dry-bulb tem erature for the. load calculation or entering water temperature for water -source equipment), the blower CFMt provided by the expanded p�rmance data, the design value for entering viet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering Viet -bulb and dry-bulb temperatures shaft be for the indoor dry bolt) and relarive humidity used for the load caloulation and shall be adjustedfor return side gains if the return duct(s) is installed in an unconditioned space., Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2 When signed and seared by a Florida -registered er>ginecr, in attached single- and multiple -family units, the capacity of eW.prnent may be sized in accordance with good design practice.. 0 R403.7.1.2 Heating equipment capacity. 0 R403.7-1-? 1 Heat pumps (teat pump sizing shall be based.on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 105 times greater than the design cooling load even if the design heating load Is 1.15'times greater than the design cooling load. i® R403.7.1.Z2 Electric resistance furnaces. Electric resistance fumaces shall be sized vhthin 4 kVV of the design requirements calculated according to tiro procedure selected in Section R403.7,1 rl 1�403.7.1.2.3 Fossil fuel heating equipment The capacity of fossil foci hearing equipment %ith patural draft atmospheric burner, Shalt not be less than the designload CaiCulatedin accordance vn"th Section R40i3.7,1. i R403.7,1,3 Extra capacity required for special occasions. Resldonces requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additronat loads carried by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating vAthin that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base toad periods is utilized. 1__I R403.8 Systems serving multiple dwelling units (Mandatorya. Systems serving multiple dwelling units shall oomply with Sections C403 and C404 of the ECG—Conurterclal Provisions in lieu of ectio n R40$. rl R403.9 Snow melt and Ice system controls (Mandatory). Sneer- and ice -melting systems, supplied through energy service to the building, shalt include automatic controls capable of shutting off the system hen the pavement temperature is above 50'F(t0°C} and no precipitation is, falling and an automatic or manual control that w III allow shWof f when the outdoor temperature is above 40T (4.80Cy. ® R403.10 Pools and permanent spa energy consumption (Mandatory). The energy, consumption of pools and permanent spas shall 'be in accordance viith Sections 11403A0.1 through R403.10.5. i R403.10.1 Heaters. The electric power to heaters shalt be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater- Operation of such switch shallnot change the setting of the 4mter thermostat. Such svAtches shall be in addition to a circuit brcakerfor the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignitions pilots. i R403.10.2 time switches. Time Switches or other control mmethods.that can automatically turn off and onaccordhg to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have bultt-ln time swatches shall be in compliance With this sectlon. Exceptions. 1. Where public health standards require 24-hour.pump operations. 2. Pumps that operate solar and waste-heat4ecovery pool heating systems. 3. Where pumps are powered exclusively from on -site reneWabie generation. Pi R403.10.3 Covers- Outdoor heated swimming pools and outdoor permanent spas shaft ba.6qulppcd %Yfth a vapor- retardant Cover on or at the water surface or a liquld cover or,ofiter means proven to reduce heat loss. Exception; Where more than 70 percent of the energy for treating, computed over an operation season, is from Site -recovered energy, such as from a peat pump or solar energy source, covers or other vapor -retardant means shad not be required. 1._ t R403.10A Gas- and oil -fired pool and spa heaters. Allgas- and oil -fired pout and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or. alter April 16, 2013, when tested in accordance with ANSI Z 21.66. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2899�De,�C.U412:34:43 R4ht3ulteeUnWc-rsai 201919.0,13 RSU27454 Ri9h; EneT00Flo�;t 2o17 Socrlon05.a.1 ComplilawSofrwat> Pag410 kADowrnentsll'Ji�tisoPIivFCMAuseReadencemp Cnlc=rUs FrontDoorfaces: N • I MANDATORY REQUIREMENTS - (Continued) I6 R403.10.5 Heat pump pool heaters. Heat Dpunn, pool heaters -shall have a minimum COP of 4.0 when tested in accordance v,3th AHRi 1160, Tabte 2, StandaTd Ratingg Cor4tions-Low Air Temperature. A test report from an Independent laboratory is required to verify procedure compliance, Geothermal swimming pool heat pumps are not required to meet !iris standard. K403.11 Portable spas (Mandatory). The energy t onsumplion of erectric powired portable spas, shall be controlled by the requirements of APSP-14. I SECTION R404 I EL# CTRIGAL POWER AND LIGHTING SYSTEMS © R404.1 Lighting equipment (Mandatory)- Not less than 75 percent of the lames in permanently installed lighting fiabdures shall by high -efficacy lamps or not Tess than 75 percent of the permanently lastalted lighting fixtures shall contain only high-efttcacy lamps. Exception: Lour -voltage lighting. ® R404AA Lighting equipment (Mandatory). Fuel gas lighting systerns shall not ht ve continuously burning pilot rights. i wrightsoft, Right-SoitdS UnivefwPl2S18 1e.0.13 RSU27454 R3gta-SneTSV0 FJ0Ma 2017 Section405AJ CoMpliontSe 99 �ccU4 1214451 17 .-WDownientsllR:�gntwftfiVAC%fusc.RWdenod.rdp Calc=LUB rrentDaorfaces.-N 3B& 4 I i i FORM R405-2017 I ate, Zip: Location: TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Builder Name Glenn Pause Permit Office, Perrrc Number Jurisdtctian: St Lucie COMPONENT AIR BARRIER CRITERIA General requirements. A continuous air barrier shall be installed In the building envelope The exterior thermal envelope contains a continuous barrier. Breaks or joints in the airbarriershall be sealed. coilinglattic The alrbarrier➢n an dro ped coilingfsofflt shalt be ali ed gn the nsulatiars and any gaps in the air barrier shall be sealed. Access oppeerdn js, drop down stairs or knee wall doors to uncondltioned attics paces shall be sealed. wails The unction of the foundation and sill plate shall be sealed.The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. skylights The space between windowidoor jambs and framing, and skylights and framing shall be sealed. Rim joists are insulated and Include an air barrier. ding I The air barrldf shall be installed'at any expin e and edge of insulation. floors} rt space �I 6s, penetrations I iw cavities I box c walls boots Exposed earth In unvented craw➢ spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Ductshafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be seated. Air seating shall be provided between the garage and conditioned spaces. , . Recessed Ilght fixtures installed in the building thermal envelope shall he seated to the drywall. The air barrier shall be installed behind electrical or communication boxes oralr�ealed boxes shall be Installed. The air barrier- shall be ➢nstalIda behind electrical orcommun➢catlon boxes orairrsoaled boxes shall be installed. HVAc register boots that penetrate building' thermal envelope sham➢ be sealed to the subfioor or drywall. When required to be sealed, Concealed fire sprinklers shall only be sealed in a manner that Is recommended by the manufacturer. Caulking or other adhosive sealants shall not he used to fill voids between fire sprinkler cover plates and walls or cellings. INSULATION INSTALLATION CRITERIA I Vr Air-Aarmeabto Insulation shaTI not be used as a seating material. The insulation in any dropped celltnglsoffit ,shall be aligned with the air barrier. Cavities with corners and headers of frame walls shall be Insulated by completely filling the cavity with a material having a, thermal resistance of R-3 per inch minimum. Exterior thermal envelope. insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Rim joists shall bo Floor framing bavity Insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be In contact with the top sidoof sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Where provided In Ilou of floor insulation, Insulation shall be permanently attached to the crawlsoace walls. Batts in narrow cavities shall be cut to A or narrow cavities shall be filled by insulation that on installation readily conforms to the available Recessed lightfixtures installed in the building thermal envelope shall be airtight and IC rated. Batt insulation shall be cut neatly to fit around wlring and plumbing in exterior walls, a Insulation that on Installation readily conforms to available space shall extend behind piping E IN" El Exterior walls adjadent to showers and tubs I ❑ shall be Insulated. J a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. i wrightSo ft- RigtASui(a uni+ersa12019 t9.4.13 RW27054 Rfgrit-a0rgy0 Ftarida 2017 Section 405.4.1 Caafiant SoltNareB.pee 0412 34A3 1 ...JOccemen4tLWight�;oltHVAC'JAuseResidence.rup Catcomm Fr934'Wfa=; N POSO 12 �I r FORM R405-2017 Envelope Leakage Test Report (Blower Door Testy Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Cade, Energy Conservation, fth Edition Jurisdiction: St Lucie Permit Number Jolt inforrratiot%` Builder_ Glenn Muse Community: Lot: Address: 5821 Mustange Cir Unit: City: Port St Lucie State: FL Zip: 34987 r Air` Lep, ageTibst Results- pass gresvres�rfiusimeeter7herthe rfarrnaaes:Prsscrpfive;or zrr rat ac% PRESCRtPTiVE ME7tiOLl The bulldirlg or d veprng Unifshall 6e tested and verified as having an au )calla a rate of item axceediirg 7 afr changes per hour at a pressure gf 0.2 inch w.g. (50 :pascaisriri `Ciiirrate ones Ind?. The building of d%� tling'un@t'shab be tested'and verified as having an air leakage rate of not PERFORI'1J�1NCt,6r M'ETH,Op ERI exceeding the se60ed-ACH(50) value;'as shoNnon.FC1F2 I:R405-2Q1T (Parforrrtance) Qr . R406=2017 ERD section labeled as Infiltration, sub -section AC060. i ACM(50j;sliec edon Fq »,I At752Ui7-Energy`Gate (Perirman�) 6rrz40 4017 x60 25694 Method for calculating building volume: CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans PASS ® code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation Fgeld measured and calculated must be verified by building department. R402,4.1.2 Testing. Testing shall be conducted in acourdance wilh AIUSIRESNEMCC 360 and reported at a ,pressure of 0.2 inch tv.g. 1 (50 Pascals). Testing shall be conducted by either Individuals as defined In Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)M, (9), or 0 or and approved thirst party. A vrrilten report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. i During testing: 1, Fxtrrier vJin joys and door-, fireplace and E%vo doors shall be closed, but not coated, beyond the intended ► other Infilteahon oostirol measures. eatIltzstripping ur I 2. pampers including exhaust, intake, makeup air, back draft and flue dampers sftall be closed, but not seated beyond intended Infiltration control measures. 13. Interior doors, If installed at the time of the test, shall be open. ,4. Exterior doors for continuous ventilation systems arrd heat recovery ventilators shall be closed and sealed, 5, heating and cooling systems, if installed at the Sine of the test, shalt be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open, Testing CgMpany . I. Company Name: Phone: I Hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above - Signature of Tester: date of Test: Printed Name, of Tester. License/Certification #_ Issuing Authority: " ttI M 2o1"ec-04 t2:34A3 ' - wrightSofi 8 4ulteV U diverse) 201019.0.13 RSU27054 Rig tit-EnerWIG Ftaffda tot 7 Seaton 405AI camm�tt Software p• , 13 .vm•, ,(a.�.ar c...kPDcwmentaietlghWftitVAWIusoResidencn.rup CW0=MJ3 Fmirtt?oarfaoes: N I FORM R405-2017 I i I Dint Leakage 'hest Depart Residential Perscriptive, Performance or ERI Method Compliance 2017 Florida wilding Code, Energy Conservation, 6th Edition Jurisdiction: St Lucie I ..:Fob l�farmatiOer, Permit Number: Builder: Glenn Muse Community: Lot: Address: 5821 Mustange Cir Unit: City: Part St Lucie State: FL Zip: 34987 System 1 cfrrt25 System 2 cfm25 System 3 cfm25 SA or any additional systCms 1 Cfm25 Totalof It S y ems Systems cf m25 + 2451 = On Total of all Total Conditioned systems Square Footage I ❑ PASS I O P'resor ptive Method ',cffn25 (Dotal} TO-q'ualifj. as "substantially leak free' Qn Total must be'less than .ar.equal to 0.041 air handler unit,is installed...1f air handler unit is not installed,; Qri!Total tuSf be less #flan 6f,equ61 to. 0.9,3: This testing method meets -the i'equirernents lh - acimrdance with Section R403:3.3. 4s'the airhandlerunit insfafkd YFSt4Qarc�^�. �n ,dudhgtesifng2 ®NO �] Perforrriarice 7 ERI Method drn25 (out or Total) , .To qualify, using this method, Qn must be,not greater thzin the proposed duct leakage Cori, specified on. Form Ft4U5 2a97 or R406-2017. ' Ceaksge Type,s0ected on Form. Qn specified do Form R405-2017 R405-2017 (LneW' Caa c) & P40$-2017 IjEuergyy. Cak) arR406r2017 Default Leakagw r� Duct tightness shall be verified by testing in accordance with ANSURESNETrICC380 by either 'individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed: as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. ;Testing Conran Company Name: Phone: I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester_ Date of Test: Printed Name of Tester: License/Certification #;t: Issuing Authority: I i J 2 '" WTfil �t`SoiCt" Righ¢SuBteO UoivCs�a12p19 1fM,ro.93 FiSU27C R1geisT EnerFiw3ma 7.097 SccE]an4054.1.CompUeret$a�ura" 01-0412:34.43 re N pryG 14 eKsi fm . �.. aMo,� _idl0nwmentstlNrighlsOR FtVr:CVSq re Re3id4nasnrr Calc= hU6 FcanE Qaartste� Reference Lorne Characteristics i I Muse Residence 5821 Mustange Cir Port St Lucie, Fi_ 349187 A4ove-grade Walls (Uo) Above -grade Wall Solar Absorptance .Above -grade Wall Infared Emittance Sasement Walls (Uo) Above -grade Floors (Uo) Slab Insulation R-Value Ceilings (Uo) Roof Solar Absorptance Roof Infared Emittance AtticventArea (f< Crawls pace Ventkea (M Exposed MasonryFloorkea (fF) Carpet & Pad R-Value DodrArea (ft) Door U-Factor i Nortfr Wind pow Area On SouthVIAndowArea (f* East Window Area (ftz) Mst VYndo►v Area (fe) Window U-Factor I Window SHGC (Heating) Window SHGC (Cooling) ACH50 lntemai Gains * (Btulday) Water heater gallons per day Water Heater set point temperature Water heater efficiency'rating Labeled Heating System Rating and Efficiency Labeled Cooling System Rating and Efficiency Air Dl�tributlon System Efficiency Thermostat Type Heating Thermostat Settings Title: Muse Residence FLBase2017 0.084 0.75 0.90 nla nla 0.0 0.030 0.75 0.90 8.17 nta 595.63 2.0 0.00 nla 0.00 43.70 43.70 43.70 0.400 0.2169 0.2169 7.00 88537 60.00 120.00 0.95 HSPF 8.2 SEER = 14.0 0-88 Manual 72.0 (All hours) PAY City: FL Fort Pierce I Air, Caics, LLC Load Short Form I House Air Calcs, LLC 7550 HiLri Hammock Lr% Vero Beach, FL32966 Phom:772.800.8413 Email: viddlyme@aircalcs.com For: Muse Residence, Glenn Muse 5821 Mustange Cir, Port St Lucie, FL 34987 Job: Date: Dec 03, 2019 By. Vicki Lynne Barenberg uutsloe ai) (-1-) 41 W Metnoa blower cloor Inside db (°F) 70 75 Shielding /stories 3 (partial)/ 1 Design TD (°F) 29 15 Pressure /AVF 50 Pa / 1764 cfm Daily range - L Inside humidity (%) ' 30 50 Moisture difference (grAb) 2 57 r' HEATING �QUIPMENT AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat I I 100 EFF 11.2 kW 38110 Btuh 23 °F 1500 cfm 0.042 cfm/Btuh 0.60 in H2O r r COOLING EQUIPMENT' Make Carrier Trade CARRIER Cond 24APB648AO0300 Coil FB4CNP048L AHRI ref 201776123 Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 13.0 EER,16 SEER 31500 Btuh 13500 Btuh 45000 Btuh 1500 cfm 0.050 cfmBtuh 0.60 in H2O 0.81 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) HtgAVF (cfm) CIgAVF .(dm) Laundry 52 313 176 13 9 De/Study 155 2241 2283 94 115 Foyer 115 2517 2118 105 107 Bath 2 61 113 77 5 4 WTR CLST 23 336 132 14 7 M Bath 110 1313 574 55 29 Lin I 9 16 11 1 1 WIC I 120 225 154 9 8 Room,16 17 31 21 1 1 Great Room 477 4837 5658 202 285 Bed 3 236 5487 3837 230 1'93 Bath 3 67 125 85 5 4 WIC 3 35 653 251 27 13 llif,hcn )Ion 999r1 400A a2 4 C7 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoit® 2019-Deo-0412:55:53 mo Page 1 ^'� a• �.eh .w .„ �N , RighFSkitek�Urrversa1201919.0.13 RSU27054 ...6-Coaerts\WrightsoftWAMuseResideme.np Calc=MJ8 FrortDoorfaoes. N ��(>s �J ®� I b J I UllIling LVJ DOW OUf 1 Z-+O GVV Master 298 6865 5426 287 273 Bed 2 I 185 2743 1808 115 91 House d 2451 35839 .29807 1500 1500 Other equip loads 1737 922 Equip. @ 0.95 RSM 29316 Latent cooling 7435 Tl1TA1 a ')nr"a '37=7a 'I9Z7rn irnn irnn Calculations approved byACCA to meet all requirements of Manual J 8th Ed. RigItSUL,0Urrversa1201919.0.13 RSU27054 ...kilDoameris\WdgWsoftWAC Lr.eResideme.np CaIc=W8 FrortDoorfaces: N 2019-Deo-0412:5553 Page 2 i I Airy Calm, LLC Building Analysis House Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: vickilynne@aircalcs.com For: Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28 °N Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) I Muse Residence, Glenn Muse 5821 Mustange Cir, Port St Lucie, FL 34987 Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Heating Cooling Moisture difference (grAb) 41 90 Infiltration: - 15 (L ) Method 77 Shielding / stories 15.0 7.5 Pressure /AVF Component Btuh/ft2 Btuh % of load Walls 2.9 6474 17.2 Glaang 30.2 10412 27.7 Doors 0 0 0 Ceilings 1.6 3888 10.3 Floors 2.6 6372 17.0 Infiltration 1.4 3206 8.5 Ducts 5486 14.6 Piping 0 0 Humidification 0 0 Venglation 1737 4.6 Adjustments 0 Total 37576 100.0 Component BtuhAt2 Btuh %of load Walls '2.3 5228 17.0 Glazing 31.6 10908 35.5 Doors 0 0 0 CeiII6 s 1.2 2995 9.7 Floors 0 0 0 Infiltration 0.4 955 3.1 Ducts 3700 12.0 Ventilation 922 3.0 Internal gains 6020 19.6 Blower 0 0 Adjustments 0 Total I 30729 100.0 Latent Cooling Load = 7435 Btuh Overall l I -value = 0.239 Btuh/t2--°F Data entries checked. Glazing Glazing Job: Date: Dec 03, 2019 By. Vicki Lynne Barenberg Heating Cooling 70 75 29 15 30 50 2A 56.9 Blower door 3 (partial) / 1 50 Pa / 1764 cfin ains -4,- wrightsofft- 201 9-Deo-04 12:55:53 � 11 MgltSU1e® Universal 201919.0.13 RSU27054 Page 1 .Ja\Doamerts\WdgHsoftWACWseResidenoe.rLp Calc=W8 FrortDoorfaces: N I Component Constructions Job: p Air Calks, LLC Date: Dec 03, 2019 House By. Vicki Lynne Barenberg Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicldlyrm@aircalcs.com For: Muse Residence, Glenn Muse 5821 Mustange Cir, Port St Lucie, FL 34987 I Design Conditions Location: Indoor: Heating Cooling Si Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (OF) 29 15 Latitude: 28°N Relative humidity (°/k,) 30 50 Outdoor: Heating Cooling Moisture,difference (gr/Ib) 2.4 56.9 Dry bulb (OF) 41 90 Infiltration: Daily range (°F) - 15 (L ) Method Blower door Wet bulb (°F) - 77 and 15.0 7.5 Shielding / stories 3 (partial) / 1 speed (mph) Pressure /AVF 50 Pa / 1764 cli n r I r r r r Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain f12 BtulJft%.°F WF/Btuh BUM Btuh BtuMft' Btuh Walls Blk wall, stucco ext, r-5 ext bd ins, 8" thk, 1/2" gypsum n 682 0.099 6.0 2.87 1956 2.40 1639 ne 25 0.099 6.0 2.87 73 2.40 61 e 186 0.099 6.0 2.87 534 2.40 447 se 32 0.099 6.0 2.87 93 2.40 78 s 635 0.099 6.0 2.87 1822 2.40 1527 w 441 0.099 6.0' 2.87 1265 2.40 1060 all 2002 0.099 6.0 2.87 5743 2.40 4812 I Partitions 12B-0sw., Frm wall, 1/2" gyp.bd ext, r-11 cav ins, 1/2" gypsum board int 260 0.097 11.0 2.81 731 1.60 416 fnsh, 2"x4" wood fnn, 16" o.c. stud I Windows Impact: Impact; NFRC rated (SHGC=0.29); 50% blinds 45°, medium; n 36 1.040 0 30.2 1086 18.6 668 50% outdoor insect screen; foreground = green grass (0.23); 1.8 ft ne 17 1.040 0 30.2 513 31.6 538 overhang(6 ft window ht, 2 ft sep.); 6.25 ft head ht a 18 1.040 0 30.2 543 38.3 689 e 27 1.040 0 30.2 799 38.3 1014 se 17 1.040 0 30.2 513 30.3 514 s 18 1.040 0 30.2 543 20.6 370 w 36 1.040 0 30.2 1086 38.3 1378 w 53 1.040 0 30.2 1598 38.3 2029 all 222 1.040 0 30.2 6680 32.5 7201 Impact: Impact; NFRC rated (SHGC=0.29); 50%blinds 45°, medium; a 48 1.040 0 30.2 1448 27.4 1315 50% outdoor insect screen; foreground = green grass (0.23); 1.8 ft. overhang (8 ft window ht, 2 ft sep.); 6.25 ft head ht Impact: Impact; NFRC rated (SHGC=0.29); 50% blinds 45°, medium; s 6 1.040 0 30.2 173 20.6 118 50% outdoor insect screen; foreground = green grass (0.23); 1.8 ft overhang (1.6 ft window ht, 2 ft sep.); 6.25 ft head ht Impact: Impact; NFRC rated (SHGC=0.29); 50% blinds 45°, medium; w 28 1.040 0 30.2 844 38.3 1072 50% outdoor insect screen; foreground = green grass (0.23); 1.8 ft w 42 1.040 0 30.2 1267 27.4 1151 overhang (7 ft window ht, 2 ft sep.); 6.25 ft head ht all 70 1.040 0 30.2 2111 31.7 2222 I Doors (none) -Ffil- vnrrightsoft® 2019-Deo-0412:55:53 .M,+•a.ea.wN -,, Ngit-SLiL@Uriversa1201919.0.13RSU27054 Page ..JdVocunents\WrightsoftHVACWhseResideme.np Calc=MJB Front Door faces: N i Ceilings Attic ceiling, mtl roof, r-20 roof ins, 1/2" gypsum Floors On grade depth, tile fir fnsh I it I I 2451 0.405 21.0 1.59 3888 1.22 2995 222 0.989 0 28.7 6372 0 0 I I . t wrightsoft® 2019-Deo•0412:55.53 .�+-•a ew.•� �. Imo., RigkSute®Uriversal201919.0.13RSU27054 Paget Id=nerts\WdghtsoftHVACWLreResidence.np Calc=MJ8 FrortDoorfams: N Q Airy Calcs, LLC Project Summary Date: Dec 03, 2019 House By. Vicki Lynne Barenberg Air Calcs, LLC 7550Hid' den Hammock Ln,Vero BeadFL32966 Phone: 772.800.8413 Email: vicldlyrre@aircalcs.com i Project• • I I Outside dt Inside db Design TC For: Muse Residence Glenn Muse 5821 Mustange ir, Port St Lucie, FL 34987 Desicin Information Weather. St Lucie Co Intl, FL, US Winter Design Conditions Heating Summary Structure Ducts Central vent (55 cfm) , Outside air Humidification Piping Equipment load Infiltration Method Shielding / stories Pressure /AVF Summer Design Conditions 41 OF Outside db 70 OF Inside db 29 OF Design TD Daily range Relative humidify Moisture difference 30352 Btuh 5486 Btuh 1737 Btuh 0 Btuh 0 Btuh 37576 Btuh Blower door 3 (partial) / 1 50 Pa P1764 cfm ' Heating Coolin Area (ft2) 2451 2451 Volume (ft3) 25694 25694 Air changes/hour 0.23 0.13 Equiv AVF (cfm) 101 56 1 1 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 11.2 kW 38110 Btuh 23 0 1500 cfm 0.042 cfmBtuh 0.60 in H2O 90 OF 75 OF 1L OF 50 % 57 grAb Sensible Cooling Equipment Load Sizing Structure 26107 Btuh Ducts 3700 Btuh Central vent (55 cfm) 922 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swin multipplier EquipmenIsensibleload 0.95 29316 Btuh Latent Cooling Equipment Load Sizing Structure 2980 Btuh Ducts 2349 Btuh Central vent (55 cfm) 2106 Btuh Outside air Equipment latent load 7435 Btuh Equipment Total Load (Sen+Lat) 36750 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 24APB648A00300 Coil FB4CNP048L AHRI ref 201776123 Efficiency 13.0 EER,16 SEER Sensible cooling 31500 Btuh Latent cooling 13500 Btuh Total cooling 45000 Btuh Actual airflow 1500 cfm Airflowfactor 0.050. cfmBtuh Static pressure 0.60 in H2O Load sensible heat ratio 0.81 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -�w =ightsolFt- 2019-Deo•0412:55:53 AI.C.P� ^4� RightSdte®Universal201919.0.13 RSU27054 Page 1 IdlD oamer/s\WdgWoftWAC\MseResidenoe.rLp Calc=MJS FrontDoorfaces: N Air l;Caics, LLC Right-M Worksheet Job: i House Date: Dec 03, 2019 Air Calks, LLC By. Vicki Lynne Barenberg 7550 Hidden Hammock LR Vero Beach, FL32966 Phone: 772.800.8413 Email: viddlyme@aircalcs.com 1 2 3 4 5 Room name Exposed yell Room height Room dimensions Room area House 2222 It 10.5 ft d 245D.6 it' Laundry 0 It 10.0 It heaftol 6.5 x 8.0 ft 52.0 iF I Ty Construction number U-value (BtuhAF--°F) Or HTM (Btuhd2) Area (ftF) or perimeter (ft) Load (Btuh) Area (T) or perimeter (ft) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 11 V�1 - - Blk wail, 96-aiiext - Impact__ -. _ .__.�_ Blk wall, stucco ext Impact Blk wall, stucco ext ~ Impact Impact ,Impact_-_-_--_ Blk wall, stucco ext Blk wall, stucco ext _ Impact _ Impact__,--_ _ Blk wall, stucco ext -� Impact Impact Impact Impact _12B-Osw-__ d Attrccecltng,,mti r. On grade depth, file �r--_0 --0099 -_-- 1.040 0.099 __-1,040 0.099 1.040 1.040 _ _ 1,040 0.099 _1.040 - 0.099 1040 1.040 �' 0.099 1.040 1.040 1.040 - 1040 ----0097--_ 989 n --n- ne _ ne a a a _ e se se - s m s s � w w w w w - 2.87 -_30.16 2.87 3016 ,2.87 30.16 30.16 ___ 30.16 2.87 30.16 2.87 30.16 30.16 -- 2.87 30.16 30.16 30.16 30.16 - -2.81 1.59 28.68- -2.40 -_18.57 2.40 --31.65 2A0 3828 3828 --27.39 2.40 3026 2.40 20.57 20.51 - 2.40 3828 3828 3828 27.39 -L1.60 122 0.00 -- 718 __.._ __36 42 _ 17 279 18 27 ,_-: 48 49 17 659 6 18 -'--600 36 53 28 __ 42 _-_.__260 _ 2451 �_ 2451 - 682 _ .. 0 25 0 1956 __1086 73 -_513 534 543 799 1448 93 513 1822 173 543 _. _ ._ . 1266 1086 1598 - 844 - 1267 L-731 _ 3888 _ . _ 6372 ^ -'-1 339 ___---_--668 61 538 447 689 1014 .._ 1315, 78 514 1527 118 370 _ _._. 1060 1378 2029 1072 _ 1151 0 0 0 0 0 _ ____0....____ 0 0 0 0 0 _ _ _v_.__ 0 0 0 0 0 0 _- 6 0 0 0.. 0 0 ' 0 0 0 _ 0 0 0 0 0 0 _.- 0 0 0 ___0 6 0 0 0 0 - 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 -_ 0 0 0 0 _104 Q Wi Lam_ I- G c G P ( C F- { ._. 186 0 0 0 32 3 635 6 _._.. 18 441 0 0 0 - - _ 0 _._--260 _2.451, _ 222 -._-_416- _ _2995 _� -0 -'_65-. _52 _ _ _ -52 --L-65 _ 5 0 _--- 183 82 - -- ----- 6 i c)AEDexcursion 52 _14 i Envelope los99ain 27147 19132 265 154 12 a) Infiltration b) Room ventilation 3206 0 955 0 0 0 0 0 13 Intemalgains: Oaupants@ 230 1 Applianceslother 4 920 5100 0 0 0 Subiotal(lines6to13) 30352 26107 265 164 14 15 Lessextemal bad Less transfer Redistribution Subtptal Ductloads - 18% 14% 0 0 0 30352 5486 0 0 0 26107 3700 18% 14% 0 0 0 265 48 0 0 0 154 22 Totallroom load Airrequired(dm) 35839 1500 29807 1500 313 13 176 9 Calculations approved byACCAto meet all requirements of Manual J 8th Ed - � w Lq"tsoft'" R igttSUL-0Uriversal201919.0.13 RSU27054 2019-Deo-041 Page 1 9 ...Id\DoamerlslWrightsoftFIVAC1MuseResiderxe.rtQ CaIc=MJB FrortDoorfaces: N Page 1 ED 2 Qom J LL CO O U 5 J Ci = - O Q r— LIM Iool00000�nicc;ocol00000lo,�,ci j; t j'?! ( t 1 i j; I i 1 3 No ID op, N v� a6 000u`�� rn N °rro r- _ �, ! N $ ! cpp C @ ' i00100{�;OO i 00i000100000IOIN0';,N, i I I OOOCN,� �O I N N N N� x I i I ± I i,Il.#'}Il,lj,}E;=III�II}IiI! fl �ao v I l0000;cn00000'o0010000oo�rn ! i LID fI1 Indz II �� I.''If o co S op 00000CIO ooFoo 000ro o ;y IoOIOo�ov000'000l00000{�o,ol I s �� o � � I ( ( I f i 'I 13 II !j $ `� cno � 00 � 0 g 0000M� $ N � � L Jv r? �0000u,orno0o{O0000000,�c+77col-' i i rn I aDV,O �� 1 1 1 } #! I i I 1 I +{ I j �, I f I 1 g} I j( !) 3 If to 1� cVO aD OOO�V co M V� N 2 { I i 1 }NI(7� % ,.{ kk f { { I I I I f �LIP x J O 100`O O,m. 00 of 0010007000o In ... o Ci O In E 'C oo'oo 01- o o o;o a oo o Q 0 of E -I fd 'N i 1(O:l(7: ii � I; 3 1 i i 1 f i i E 1 o e lon'o In O ao m rn o co;or� r� o ao ao ao rn�o, wgW.gWNN'R(WvNv.q,Wq..NNN'iF cQq,E8 j I i _ 8 N aD;N �—�N 2 21�.. N OIN / O N pp 2 ap �! Mj C9 f'7 N c7{ NN� ch f'O (h U {hcD'f� cD'I� t0 tD (O I� (OINCO O'n cD c0 cD c0 OI CO O���O-1c0 IN OcV O(N 000 NOlfV.00i(VO 000lN, 00- 2 � m # C, c')111 m ch c0 m, c�) C'0 M M c7 M N ,cc+ 838�. i33333 r�ri I morngg oggo o;rnoo�Lrn 000rnoo, g'H'EH9ci ��'�'vjrn 1 { f I s,° o 'cs',Z6 ,o } IN it it It It }d 1 I 1 I j I i c �0 D co r c d o t5 tf t3 .`- m* m o mf`i° m} m m m m �r� a o`rio a �a aoao 1 ! o c — moo �^ ErnEami cJ'E'vm Uc YE'—`EYEEE�eE,x �eEEEE��' °o.—m_m---°° ImEE,pp-- Q� TI�j;aU;�1 ' EEE08 8 8 -F - 3 �Nch VO Air''Calcs, LLC Right-J® Worksheet House Air Calm, LLC 7550 H ddenHammodcLr, Vero Beach, FL32966 Phone:772.800.8413 Email: vicldlyme@aircalcs.com Job: Date: Dec 03, 2019 By: Vicki Lynne Barenberg 1 Room name Bath 2 WTR CLST 2 3 Exposed wall Room height 0 ft 10.0 ft heat/cool 3.5 ft 10.0 it heat/cool 4 5 Room dimensions Room area 11.0 x 5.5 It 60.5 fe 6.5 x 3.5 ft 22.8 W Ty Construction U-value Or HTM Area (ft') Load Area (its) Load number (BtuhdFF OF) (Btuh&) or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk well, stucco e)d Impact __ __ _ _ _ _.- Blk wall, stucco e)d _ _ ._. 1040 0.099 _ n„ ne _ 30116 2.87 -1A.57 2.40 -. _--0 0 ... _ ..__ 0 0 ..__- -- --0 0 _ _ _ - _ 0 0 _ -__ ----_0 0 _ _ _ 0 0 0. 0 - --- -0 0 11 " Impact-- ------ Blk well, stucco e)d ----1,040,.ne_-__30.16 0.099 a 2.87 _ 31.65 2A0 0 0 --0 --- 0 0 - --6 0 0 - ---0 0 -- --0- 0 --0 0 -- --0 0 _ Impact Impact Impact-._. __- _ 1.040 1.040 1.040 a a _-e 30.16 30.16 __--30.16 3828 3828 __27.39 0 0 -___-- _0 0 0 0 D 0 0 0 0 0 O 0 0 0 0 0._ 0 0 0 �G Blk wall, stucco e)d 0.099 1.040 se se 2.87 3.0.16 2.40 3026 0 0 _0_ 0 0 0 0 _3 0 0 _,___ 0 0 _____0. 0 0 0 0 - 0 0 G Blkwall,stucco e)d Impact Impact-___ _ _ -._..- _ 0.099 1.040 _-__.__1.949 . s s 2.87 30.16 30.16, _ _ 2.40, 20.57 20.57 _-____-0 0 -. -_--- 0 0 0 - _-.- __..0 0 0 _-_._ _0 0 0 _- - 35 0 0 - 35 0 0 100 0 0 84 0 0 Blk wall, stucco e)d Impact 0.099 1.040 --s_ w w _._. 2.87 30.16 _ 2.40 3828 _.---0 0 0 ---_- 0 0 -- _ 6 0 . __ _ __0 - 0 _ , _ _ __ -- 6 - 0 -_- -_ _-6 0 -- ----- -- 0 0 __----_ 0 0 Impact Impact Impact 1.040 1.040 1.040 w w w 30.16 30.16 30.16 3828 3828 27.39 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P_l; _ __ C _ - - 12670sw -_. _. Atlicoeilinq,mill r - -__ U 097 0.405 - . 2.811 1.59 __LI.60 122 _ _ _. _9 61- _ _. _ 0 61 ._.L O 96 _ _0 _74 -__ - _ 23 -- -- L.0 _ 23 _- -- 0 -_. 36 _.. -- 0 - ----0 - -- - -- -- - - --- 6 c) AED excursion -6 -10 Envelope losstgain 96 68 237 102 12 a) Infiltration b) Roomventlation 0 0 0 0 48 0 14 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtbtal (lines 6 to 13) 96 68 285 116 14 15 Lesse)demalload Less transfer Redistribution Subtotal Ductloads 18% 14% 0 0 0 96 17 0 0 0 68 10 18% 14% 0 0 0 285 51 0 0 0 116 16 Total room load Airrequired(dm) 15 113 77 4 336 14 132 7 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. ,ft-1.r wrigtitsolFt� 2019-Deo-0412:55:53 Rigtt-Srite@ Uriversa1201919.0.13 RSU27054 Page 3 IdlDoamertslWdgtisoftHVAGWuseResidence.nQ Calc=W8 FrontDoorfaces: N A ' i • Air Caics, LLC Right-M Worksheet House Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: viddlyme@aircalcs.com Job: Date: Dec 03, 2019 By. Vicki Lynne Barenberg 1 2 3 4 5 I Room name Exposed wall Room height Room dimensions Room area MBath 11.0 It 10.0 It heat/000l 10.0 x 11.0 It 110.0 ft2 Lin 0 It 10.0 It heaUcool 3.5 x 2.5 it 8.8 ft' Ty Construction number U-value (13trrhA221FF) Or HTM (Btuhflt-) Area (ft2) or perimeter (it) Load (Btuh) Area (ft2) or perimeter (it) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 1 VNj G_ Blk wall, stucco ext Impact,-•---_ . - Blk wall, stucco ext Impact bik wall, stucco ext - Impact Impact Impact ____ Blk wall, shioco ext Impact- - Blkwall,stucco ext -- Impact .Impact__.-_______- Blk wall, stucco ext Impact Impact Impact 128 0sw _ _ + Athcceilinp, mtl r ,Ongradedep>h,>tle 0.099 ._-.__1.040 0.099 1.040 0.099 1.040 1.040 _._ __1.040 0.099 1.040 -- 0.099 1.040 -. 1-W 0.099 1.040 1.040 1.040 Gr`- 0 097 - -0405 __._ 0989 n _.0_.. ne ._Re_ a a a _.__e se se -s s _s w w w w __. _-._. 2.87 __ 30.16 2.87 _. 30.16 2.87 30.16 30.16 -_ 30.16 2.87 30.16 2.87 30.16 -AQ-1q 2.87 30.16 30.16 30.16 2 81 _ 159. ,28.68- 2.40 __ 18.57 2.40 31.65 -- 2A0 3828 3828 _,-.27.39 2.46 3.026 - -2.40 2057 _.._20.57 2.40 3828 3828 3828 j Q0 _122 _ 0.00 0- _.____ , _0 0 0 -�^ 0 0 0 _ _ 0 0 0 - 110. 6 ------ 0 0 0 0 0 � 110 _ 110 0 -...___ 0 0 0 0 0 0 0 0 104 6 __.-___0 0 0 0 0 110 -.- _u11 0 _ 0 0 __--_ 0 0 0 0 0 0 299 173 _-_____. _0 0 0 0 0 .-_ 175 _- 315 0 __..-.__._0 0 ___w 0 0 0 0 0 0 -- _251 118 _-_-__ 0 0 0 0 0 134 0 0 � 0 -___�0 0 0 0 0 0 -- - - 0 0 ____ __4 0 0 0 0 9 0 _.._- ._-0 0 0 0 _ 0 0 0 0 0 0 0 _ ___ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ _._.-- 0 0 -- 0 0 0 0 0 _ _A. ��.__ ' ' G W, I I G -_.-..- 0 0 0 0 0 - - - 0 0 - - -A 0 0 0 0 _- 9 _._ _ 0 -(G vw I G I--G l P C - i_-- -_ _._ _9 6 c) AED excursion -45 -1 En.' lopeloss(gain 962 458 14 10 12 a) Infiltration b) Roornventilation 150 0 45 0 1 0 0 0 0 13 Internal gains: Occupants@ 230 Applianceslother 0 0 0 0 0 0 i Subtotal (lines6 to 13) 1112 503 14 10 14 15 Less'e temal load Less;transfer Redistribution Subtotal Ductloads 18% 14% 0 0 0 1112 201 0 0 0 503 71 18% 14%1 0 0 0 14 3 0 0 0 10 1 Total' 'room load Pirrequi%(dm) 1313 55 574 29 16 1 11 1 to meet all requirements of Manual J 8th Ed. -�- wriightsoft� ....... RigttSuteO Uriversa1201919.0.13 RSU27054 ACCK IdlDoc nertslWrightsoftHVACW1useResiderce.np Calc=MJ8 Frort Door faces: N 201 9-Deo-04 12:55.53 Page 4 4- Air Caics, LLC Right-M Worksheet Job: House Date: Dec 03, 2019 Air Calm, LLC By. Vicki Lynne Barenberg 7550 Hidden Hammock Lq Vero Beads, FL32966 Phone:772.800.8413 Email: viddlyme@aircalcs.com 1 2 3 4 5 i Room name E)posedmdl Room height Room dimensions Room area WIC O ft 10D ft heaUeool. 1.0 x 120.0 It 120.0 T Room16 O ft 10.0 ft heat/cool 3.0 x 5.5 It 16.5 ft Ty Construction number U-value (BtAffe--T) Or HTM (B Area (T) or perimeter (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 1/N1 G V)/ r-- VVV���lll i , _ tLBlk G V�11 4' -I- G t G -' - Blk wall, stucco ea -- Impad_ ..__ ___.._ - Blkwall, stucco ext (mead -- - - Blk wall, stucoo ead Impact Impact trnpad_-,m_--- wall, sttu000 e)d Blkwall,stucco e)d _ Impact !Tpad _w____ ,_ __ - 0.099 1040._n__ 0.099 1.040 -6-- ne ne 'e a a e . se se s.009 s _ s 2.87 _-30.16 2.87 30.16 2.87 30.16 30.16 ___30.16 2.87 30Y16 .-- 2-S7 30.16 _, , 30.16 2 4Q ._. 18-57 2A0 0 _ Q 0 0 . 0 0 0 0 6 _ _ _0.__... 0 0 0 U. 0--�- 0 0 0 0 0 - 0 ___.,-_0 0 0 0 0 0 0 - 0 0. -"0 0 0.099 1.040 1.040 1.040 0.099 1.040 0 1.040 �. 1.(I 0 -31.65 2.40 3828 3828 __27.39 2.40 3026 2.40 20.57 20 -- -557 ' 0 0 6 0 0 _ 0 0 0 0 .---0 0 - _ 0 -� 0 0 0 _, 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . 0. 6 0 0 -___Q 0 0 0 0 0 __ 0 0 0 0 0 0 0 _Y'� 0 0 0 _ 0 0 0 �- 0 ___-.__r0 0 '�~. 0 . 0 0 ' 0 _ o 0 0 - �i0 __-- 0 0 0 0 0 _ 0 Blk wall, stucco a Impact Impact Impact trnpad 0.099 1.040 1.040 1.040 1.040 w w w w w 2.87 30.16 30.16 30.16 30.16 2.40 3828 3828 3828 27.39 0 0 0 0 0 0 0 0 0 0 U 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P j _ C Eir,_ -12B-0sw-_v___ ^� AtIicoeilinq, mtl r-.m_ �Ongradedepth,tile-__ _w0.097 0.405 - Q.989 _.- _ - _2,81. 1.59 28.66 ,_1-60 122 �6.007=_ � .W_ o 120 120 :.__-__..,o 120 b _ jr _ 0 _ 190 - 0 ---0 _-o 147 _. _._ __ oo: 17 17 _._ 17 ----0 26 -0. m �o 20 i 0. 6 c) AED excursion -12 _2 Envelope IossJgain 190 135 26 19 12 a) Infiltration b) Room ventilation 0 0 0 0 10 0 0 0 13 Intemalgains: Occupants@ 230 1 Appliances/other 0 0 0 0 0 0 Subfatal (Iines 6 to 13) 190' 135 26 19 14 15 I. xlemal load Less transfer Redistribution Subtotal Dud loads 18% 14% 0 0 0 190 34 0 0 0 135 19 18% 14% 0 0 0 26 5 0 0 0 19 3 Total room load Airrequired(dm) 225 9 154 8 31 1 21 1 I Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. r}► wr➢ghttsotFt• 2019-Deo-0412:55:53 NgttSutsO Uriversal 201919.0.13 RSU27054 Page 5 ...IalDoamertslWrighisoftWAOMLwResiderce.np Calc=NU8 Frort Door faces: N Air Calcs, LLC Right-M Worksheet Job: I House Date: Dec 03, 2019 By. Vicki Lynne Barenberg Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicldlyrm@alrcaics.com 1 Room name Great Room Bed 3 2 E)qrosed hell 19.0 ft 402 It 3 Doom height 11.0 it heat/000l 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 476.5 ft 476.5 ft2 1.0 x 235.9 it 235.9 iF Ty Construction U-value Or HTM Area (T) Load Area (T) Load number (BtuhhP--°F) (BtuhA?) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 V+1 G. ___.�____._ _ Blk wall, stucco e) Impact ---- __ 0.099 _-_-_1.040 __. n _-n-- ___ 2.87 --_X16. 2.40 _._ 18.57 -_______ __ 0 _0 ,___ _-._______-0 0 ° 0 0 - 0 _-.-___, 140 42 __M_______--___-,__a.______. 140 25 402 73 336 61 11 •Impact Blk wall, stucco e)d 1.040 0.099 ne _ e 30.16 2.87 31.65 -' 2.46 0 _____ 0 0 0 0 0 -- - 0 17 - 80 _0 62 _-_ 513 178 _-. _ 538 149 --___G - x-- "- --6 Impact Impact _Impact-_-._,____--- 1.040 1.040 a a 30.16 30.16 3828 3828 0 0 0 0 0 0 0 0 _Q 18 0 0 0 543 0 689 0 W- BIk wall, stucco e)d 0.099 se 2.67 2.40 0 0 0 0 49 32 93 78 i Impact _ - BIk wall, stucco e)d Impact Impact Blkwall,sbiccoe)d Impact 1.040 - -- ___- 0.099 1.040 . 1.040 0.099 1.040 se ---- s s _ s_ w w 30.16 - - - 2.87 30.16 - -30.16 2.87 30.16 3026 __ 2.40 20.57 _ __2057 _ 2.40 3828 0 -_ 0 0 0 - 209 0 0 __._._- _ ° 0 _0 139 0 0 _- � 0 0 0 --399 0 0 ---_ 0 0 0 - 334 0 17 _- - --90 0 0 0 0 3 -- -- 90 0 0 0 0 513 - -258 0 0 _ 0 0 514 - - 216 0 0 _.0 0 Impact Impact 1.040 1.040 w w W_ 30.16 30.16 30.16 3828 3828 0 28 42 0 0 0 0 844 1267 0 1072 1151 0 0 0 0 0 0 0 0. 0 0 �. __ .-.__ P i _. _128-0sw -. _ _ t o os7 __ 2si- _ -27.39 L rso - -- - _ 0 - ° 4--- -0 - - ° __-- -0 ° - _-- -. 4_ _ o -------. . - ° ---_- _ -- - o C Athccellinp, mtl r 0405 -_ _ 1.59 122 477 - 477 756 -- 582 . - - 236 -_ 374 - l F_ .___' -- --' - .On gradedepth,tilea_ __ .__ _-0989 _-- __ _ - 28.68 --_-0.00 -.-_-477 _ ._-.__ __19 . 545 -__ � __-__A 236 __ ___-236 - 40 _ .__ _. _288 _ - __ - --- 6 c)AEDexmrsion. 372 -174 i Envelopelosslgain 3811 3511 4098 2697 12 a) Infiltration 285 85 549 163 b) IRoomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Applianoes/other 900 500 Subtotal (lines 6 to 13) 4096 4956 4647 3361 Less 6demalload 0 0 0 0 Lesstransfer 0 0 0 0 14 Redistribution Subbital 0 4096 0 4956 0 4647 0 3361 15 Duct Pads 18% 14%1 740 702 18% 14%1 8Qj 476 Total room load 4837 5658 5487 10 3837 Airrequired (dm) 202 285 193 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - id- wgDftt:sc vt- 2019-Dec-0412:55:53 Aft,l "" "' Right-Sute®Universal 201919.0.13RSU27054 Page6 ...I cureris\WdgltsoftWACWuseResidenoe.np Calc=MJ8 FrordDoorfaoes: N i t % t Air'Caics, LLC Right-M Worksheet House Air Caics, LLC 7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772.800.8413 Email: vicdlyrre@aircalcs.com Job: Date: Dec 03, 2019 By. Vicki Lynne Barenberg 1 2 3 4 5 IRoom name �Fposedwall Room height Room dimensions Room area Bath 3 0 ft 10.0 It heaV000l 9.5 x .7.0 It 66.5 Rz WIC 3 7.0 It 10.0 It heat/cool 5.0 x 7.0 It 35.0 R 17y Construction number U-value (Btuhr F) Or HTM (BtuhHt=) Area or perimeter (ft) Load (Btiuh) orperimeter(ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V)!1 _Impact Vy, �I' ' G t V+/I C _._._l. -.4--- - Blk wall, stu000 e --- _. -__ Blk wall, stucco ext Impact Blkwall, stucco ext Impact Impact Impact-._ _.-._--- BIk wall, stucco ext Impact---- _ Impactl,sili000ext Impact ImpadTM _- _ Blkwall,stuocoe)d Impact Impact Impact Impact Mcoeilmq, mtl r -- On grade depth, tile__ _ - 009'9 .1.040 0.099 1.040 - n __R.._ ne - ne a a a -e se se _ s s s w w w w _ w_ � 2.87 _.._30.16 2.87 __ 30.16 2.87 30.16 30.16 -_3016 2.87 30.16 - _-.___.-__ 2.16 30.16 30.16 2.87 30.16 30.16 30.16 3016 _. _281 _ 1.59 _ _28.68 - ' 201 _ - Q 0 _ _ 0 0 0 0 _.._0 _ 168 -- __0. 0 _0 0 0 0 0 0 0 0 0 -_- - 0 0 0 0 0 __- 43_ 2.40 18.57 2.40 3165 2.40 3828 3828 -_27.39 2.40 3026 2.57 20.57 20 57 2.40 3828 3828 3828 27.39 __G,� ...1.60 1.22 _.__3.00 - 0 - __0 0 _ 0 - - 0 0 0 __- 0 0 0 0 0 . 0 0 0 0 0 0 _ _0 -� 67 _'___ _.67 p _ __..._0 0 0 0 0 0 0 0 0 _. 0 0 0 0 0 0 0 _ 0 - ___Q __-67 0 -___0 ____---0 0 -^ i0 0 0 .__.__: 0 0 0 __ _._ _ 0 0 0 0 0 0 0 _ _ _ 0 ly . 0 _ _ _ 106 _-.__ _0 _.__ 0 --'---0- _ 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 __0 - _ 0 , � 81- --- 70 _0 0 0 "�- 70 _ _0 0 0 --� 0 0 0 _...-__.0 0 .---._---. 0 0 0 0 0 0 0 0 _ _ 0 ___:4N__-0 35 -_,7 0.099 1.040 1.040 -r_-1.040 0.099 1.040 - __.-__ 1.040 1.040 1.040 0.099 1.040 1.040 1.040 1049 --_ 0405 _ 0989 0 0 0 ._. _ 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 -.0, 56- _-- 201 _._ .___ 0 0 0 0 0 0 0 0 - 0 - - _ 35 _ 35 __- I 6 I c) AED excursion -7 -20 Envelope loss/gain 106 75 457 191 12 a) Infiltration b) Room ventilation 0 0 0 0 96 0 28 0 13 Intern Ialgains. Occupants@ 230 Appliances(other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 106 75 553 220 14 15 Lesse)demalload Less transfer Redistribution Subtotal Dudloads 18% 14% 0 0 0 106 19 0 0 0 75 11 18% 14% 0 0 0 553 10 0 0 0 0 220 31 Total room load Air required(dm) 125 51 85 4 653 271 251 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -F- wrigF�tsoft- RigH-SuiteOUriversal201919.0.13 RSU27054 2019-Dec-0412:55:53 '�� ...IdlDoameris\Wrigtd oft FNAC1Muse Residence.nQ Calc= MJ8 Frort Doorfaces: N Page 7 Job: i I i AirlCalcs, LLC Right-J® Worksheet House Date: Dec 03, 2019 By. Vicki Lynne Barenberg Air Calcs, LLC 7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772.800.8413 Email: viddlyme@aircalcs.00m 1 2 3 4 5 i Room name E)q)osed vkall Room height Room dimensions Room area Mtchen 20.0 It 10.0 It heaU000l 14.5 x 20.0 It 290D ft' Dining 37.0 It 10.0 It heal1cool 14.5 x 14.0 It 203.0 IF Ty I Construction number U-value (Btuhlft-°F) Or HTM (BtuNT) Area (ft') or perimeter (ft) Load (Btuh) Area (fF) or perimeter (ft) Load (Bluh) Heat Cool Gross N/P/3 Heat Cool Gross N/P/S Heat Cool 6 11 bi Jmpad _--_____�; Blk wall, stucco ext Impact - _-__n7 ._____ 1.040 0.099 1A40 -n_ ne ne_ a a a -a-, se se s _ s w w w w w _ �_ ___30.16 2.87 3016- 2.87 30.16 30.16 ,_._3016 2.87 30.16 2.87 30.16 30.16 2.87 30.16 30.16 30.16 3016, 1.59 _=28.68 __.__-_ - 18.57 2.40 31^65 -...._.0 0 0 - _ 3 0 0 574 - .._ _0 0 0 4 0 0 0 _40-- 1-04 298kfsax __,_,•1086 0 0 250 _ 668. 0 0 _ -_-._..-..36 0 0 --P 0 0 i. Bfk wall, stucco e)d W Impact Impact Impact__.......... _ Blk wall, stucco exi Impact - Blkwall,silioobext '� Impact I npad _ Blk wall, stuoco e)d Impact Impact Impact Impact 12B Osw _ Atliccellinq.mtl r Orl.grade_depth,tile� _ 0.099 - 1.040 1.040 1.040 0.099 1.040 0.099-s 1.040 _- 1.040 0.099 1.040 1.040 1.040 1040 0405 0.989 2.40 3828 3828 -_27,39 2.40 3026 2.4.40 20.57 20-57 2.40 3828 3828 3828 27.39 122 ___ 0 0 0 __ - U 0 0 .0 0 _ __ - 9 0 0 0 0 0 290 _290 0 0 0 - 0 0 0 0 0 _ 0 _ 0 0 0. 0 0 290 20 0 0 0 _ _ 0 0 0 O 0 _ 0 0 0 0 0 0 0 0 _ 0 0 0 _ 0 0 0 0 0 0 0 -_._ 0 -_ 354 , 0 0 0 0 -� 0 0 - 0 0 145 36 0 0 0 _ 0. -_ 203 _ �_203 0 0 0 -__ 0 ._,- 0 .__�. 0 0 109 0 0 0 _0 _ l�_ 0 - '203 _ 37 0 0 0 _ Q 0 0 0 313 1086 0 0 0 6 0 0 _..__._ 0 0 _ 0 0 262 1378 0 0 0 Vf1l �--{ _ P C- Y F_ - I 322 ___ 1061 _ 460 -�57_4 . +�0.00 i 6 c) AED excursion -253 67 Envelope low/gain 1607 582 4410 3078 12 a) Infiltration b) Room ventilation 273 0 81 0 505 0 150 0 13 Intern all gains: Occupants@ 230 Appliances/other 2 460 1700 0 0 250 Sublo U (lines 6 to 13) 1881 2823 4915 3478 14 15 Lessextemalload Less transfer Redistribution Subtotal Dud loads 18% 141/6 0 0 0 1881 340 0 0 0 28231 400 18% 14% 1888 0 0 0 4915 0 0 0 3478 493 Total room load Air required (cfm) 2220 93 3224 162 5803 243 3971 200 I Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrrgfftsoR� . CP. RigltSute® Uriversal 201919.0.13 RSU27054 2019-Deo-041 Page 8 m IalDocertsUrightsoftWACIMuseResidenoe.np Calc=MJ8 Front Door faces: N g I I Air ICalcs, LLC Right-M Worksheet House Air Caltcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: viddlyrre@airaalcs.com Job: Date: Dec 03, 2019 By. Vicki Lynne Barenberg 1 2 3 4 5 Roorn name Exposed viall Room height Room dimensions Room area Master 49.0 ft 12.0 It heaNcool 1.0 x 298.0 it 298D ftz Bed 2 16.5 It 10.0 it heaftol 1D x 185.3 ft 185.3 tt= Ty Construction number U-value (BWhM2--°F) Or HTM (Btuhgl) Area (iF) or perimeter (ft) Load (Btuh) Area (fF) or perimeter (ft) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 11 Vill: �'..-_ �� ' ; G W, I C 1 L_G T - I--G _'p-- 1 P C ( Blk wall, stu000 e� Impact---_ Blk wall, stucco ext Impad Bik wall, stucco ext Impact Impact Impad-- - BIk wall, stu000 ext Impad _- BIk wall, stucco e)d Impact Unpact _ Blk wall, stucco e)d Impact Impact Impact Impact - _12B Osw �.__ Athcoeilinq, mti r gradedepth,tile- 0.089 -___ 1:040 0.099 1,040 n -_n- ne 2.87 Fr30.16, 2.87 3016 1 2.87 30.16 30.16 ___30,16. 2.87 30.16 2.87 30.16 30.16 2.87 30.16 30.16 30.16 30.16 2.81 _ 1.59 28.68 -2.40 _ -18.57 2.40 - 3165 2.40 3828 3828 __ _27.39 2.40 3026 - 2.40 20.57 _�2057 2.40 3828 3828 3828 27.39 _, 1.60 122 0.00 _-._.____ 168 '-.J 0 0 0 - 168 0 0 0 482- __--0 0 0 ....._--. - 404 --- --- 0 0 0 - 0 -----0'-- 0 -- 0 0 0 0 __..__.-0. 0 0 �. 0 _- 0.099 1.040 1.040 _...- 1.040 0.099 1.040 0.099 1.040 �_ 1.040 0.099 1.040 1.040 1.040 1.040 _ 0.097 �_ 0.405 _ _ U989. _ne a a a a se se - s s _ s _ w w w w w _ -_ 0 0 0 _ _._.___0 0 0 174 0 _0 246 0 53 0 0 _. -_0 298 __�298 _ 0 0 0 0 _ 0 0 0 , 0 0 0 499 0 A 554 0 1598 0 __0 (r ___0 _-__473 -_ 1405 •0 0 0 ___0 0 0 _ 0 0 0 .____.._._._0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 ___.___0 0 0 0 0 _ 174 0 0 ' 418 0 0 - , 464 0 2029 0 _- 0 _-----.0 - 364 -__ 0 165 0 18 - - 0 0 0 0 -- 0 �- 130 185 - -147 0 18 - 0 0 0 0 0 _-__130 - 185 _ �422 0 543 _ 0 0 0 0 - 0 - 366 294 47.3. _ 353 0 370 ` --0 0 0 0 0 _--- - 208 226 ---A__ 193 0 0 0 0 e_____._ 0 298 ___--49 I 6 c) AE D excursion 335 -142 i Envelope loss/gain 5011 4014 2097 1016 12 a) infiltration b) Room ventilation 803 0 239 0 225 0 67 0 13 Intemalgains: Occupants@ 230 Applianceslother 0 0 500 0 0 500 Subtotal (lines 6 to 13) 5814 4753 2323 1583 14 15 Less"malload Less translar Redistribution Subtotal Dud loads 18% 14% 0 0 0 5814 1051 0 0 0 4753 674 18% 14% 0 0 0 2323 420 0 0 0 1583 224 Total room load Air required (dm) 6865 287 5426 273 2743 115 1808 91 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -41- wrlghtsoR 2019-Deo-0412:55:53 Right-SuteOUniversal 201919.0.13 RSU27054 Page 9 Id�amertslWNgttsoftWACIMuseResiderce.rcp Calc=MJ8 FrortDoorfaces: N I a i i Airy Calcs, LLC Manual S Compliance Report Date: Dec 03, Zo,s House By. Vicki Lynne Barenberg Air Calcs, LLC i 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vialilyrm@aircaics.com Project• • For: Muse Residence, Glenn Muse 5821 Mustange Cir, Port St Lucie, FL 34987 Design Conditions Outdoor design DB: 90.4°F Sensible gain: 30729 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.4°F Latent gain: 7435 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 38164 Btuh Indoor RH: 50% Estimated airflow: 1500 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Carrier Model: 24APB648A00300+FB4CNP048L Actual airflow: 1500 cfm Sensible capacity: 35179 Btuh 114% of load Latent capacity: 8712 Btuh 117% of load Total capacity: 43891 Btuh I, 115% of load SHR: 80% Heating Equipment Design Conditions Outdoor design DB: 41.0°F Heat loss: 37576 Btuh Entering coil DB: 68.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions i Equipmenttype: Elec.strip Manufacturer: Model: Actual airflow: 1500 cfm Output capacity. 11.2 kW 101 % of load Temp. rise: 50 of Meets all requirements ofACCA Manual S. wrightsoft�' 2019-Deo-0412:55:54 �. �M*A• OwN�� �mw� Right-Sute®Universal201919.0.13RSU27054 Page 1 IalDoamerlslWrightsoftHVACWhseResidence.rkQ CaIc=MJB Front Door faces: N