HomeMy WebLinkAboutSOIL NUCLEAR GAUGEG�i�•
�RNASION
Port St: Lucia -
FBPE CA # 4930
607 NW Commodity Cove
Port St. Lucie. FL 34986
Phone:772-924-35751 Fax:772-924-3580
Soil Nuclear Gauge
Report Date: 1/9/2019
Test Method: ASTM D 6938 _
Client:
Glenn Muse
316 Kestor-Drive -
Port Saint Lucie, FL 34953
/e 0 - VYJ 7
LE C0-PV
Pro'ec . +e
19-1120.00 -
5821 Mustang Circle
Port St Lucie, FL
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
(%
In Place
Dry Density
pc
Probe
Depth
(In)
Percent
Compaction
Min/Max
Comp.
%)
Remark
1
1/7/19
P-1
N/A
10.7
106.3
9.6
105.7
12
99
95 / 105
Pass
2
117/19
P-1
N/A
10.7
106.3
10.3
104.5
12
98
95/ 105
Pass
3
1
117/19
1 P-1
N/A
10.7
1 06.3
1 9.8
1 1060-1
12
1 100
1 95 / 005
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make I Model / SN / Calibrated
Field Technician
1
Above Stripped Surface: Southeast Comer
0-1
Troxler / T3430 / 34784 /
Baker, Jeff
2
Above Stripped Surface: Northwest Corner
0-1
Troxler / T3430 / 34784 /
Baker, Jeff
3
Above Stripped Surface: Center
0-1
Troxler / T3430 134784 /
Baker, Jeff
Remarks
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
6-
0
�ONN K ..
OCENSF
No 63218 j
09/a9/2019
UrE of
Pro @�qibn f er•# � 8
Staeei^'
�/�/lltllttt�\\
Test Reports shall not be reproduced, except in full, withoutthe written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Soil Nuclear Gauge
Client:
Project:
Report Date: 2/1/2019
Glenn Muse
19-1120.00
,RNA11oaPv
Test Method: ASTM_D 6938
31.6 Kestor Drive - - - -
-5821- Mustang Circle
-Part-St. Lucle
Port Saint Lucie, FL 34953
Port St Lucie, FL
FBPE CA # 4930
607 NW Commodity Cove
Port St. Lucie, FL 34986
Phone: 772-924-35751 Fax: 772-924-3580
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
(%
In Place
Dry Density
pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
%)
Remark
4
1/22/19
P-1
N/A
10.7
106.3
10.4
105.3
12
99
981105
Pass
5
1/22/19
P-1
N/A
10.7
106.3
10.0
106.7
12
100
98 / 105
Pass
6
1/22/19
P-1
N/A
10.7
106.3
10.8
104.7
12
98
98 / 105
Pass
7
1122/19
P-1
N/A
10.7
106.3
9.8
105.6
12
99
98 / 105
Pass
8
1/22/19
P-1
NIA
10.7
106.3
10.4
105.7
12
99
98 / 105
Pass
9
1/22/19
P-1
NIA
10.7
106.3
10.3
105.1
12
99
981105
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
4
Above Stripped Surface: Southeast Corner
1-2
Troxler / 3430 / 24566 /
Baker, Jeff
5
Above Stripped Surface: Northwest Corner
1-2
Troxler / 3430 / 24566 /
Baker, Jeff
6 -
Above Stripped Surface: Center
1-2
Troxler / 3430 / 24566 /
Baker, Jeff
7
lAbove Stripped Surface: Northwest Comer
2-3
1
Troxler / 3430 124566 /
Baker, Jeff
8
jAbove Stripped Surface: Southeast Comer
2-3
Troxler / 3430 / 24566 /
1 Baker, Jeff
9
jAbove Stripped Surface: Center
2-3
Troxler / 3430 / 24566 /
Baker, Jeff
Remarks
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
\��Itll1111////
��904 KEN * //
VI,CENSF
No 6 18
�, 02/01 /2019
AKent, P.E.
rir i ipna1Wl,n� 5 RCer #�6 2T8
StafPy F�OnaaRIDP'. ' G�
�'� � )NAL
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1