Loading...
HomeMy WebLinkAboutSite Plan20' BUILDING SETBACK15' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER25' BUILDING SETBACK20' BUILDING SETBACK15' LANDSCAPE BUFFER10 RV/BOAT CANOPY PARKING9,220 SQ.FT. (14 SPACES) 12x45RV/BOAT CANOPY PARKING5,133 SQ.FT. (9 SPACES)3 STORY BUILDING "A"103,200 SFFFE = 24.5'1 0 ' L A N D S C A P E B U F F E R 10' LANDS CAPE B UFFE R RV/BOAT CANOPY PARKING13,128 SQ.FT. (20 SPACES)12x45LS 20' BUILDING SETBACK BIKE 10' L A N D S C A P E B U F F E R W W W PROPOSED DRY RETENTION POND EXISTING POND W W WWWWWW4 FIREFIREFIREMM20' B U I L D I N G S E T B A C K 2 0 ' B U I L D I NG S E T B A C K 20' BUIL DI N G SETBA CK AA B B C C D D E E 10' RIGHT OF WAY EXPANSION R25' R8'R10'R 1 5 'R12'R12'10'18' 40' 30' R 2 5 'R8'R15'R15'R15'40'R 1 5 ' R15'12'12'40'45'40'45'30'147.6'79.8'R2 5 ' 30'12'30'26'R25'10'R25' R20'R5'20'20'20'25'20'20'20'20' 44. 4 ' BU I L D I N G TIE 40. 7 ' BU I L D I N G TIE 77.3'BUILDINGTIE10 0 '300'20'70'70'70'70'11 0 ' 20' 10' 10' 10' DATENO:ENGINEER'S NAME & PE#DATE:REVISION/ISSUE:BY:PROJECT # SCALE SHEET JEREMY R. ANDERSON, P.E. P.E. LICENSE NO. 71636 220.051 03/26/2021 COMMON OAK ENGINEERING 1209 EDGEWATER DRIVE, SUITE 100 WINTER PARK, FL. 32789 (407)951-5915 CERTIFICATE OF AUTHORIZATION: 32644 RAPID BUILDINGSOLUTIONSSLEF STOARGEATKINGS HIGHWAY350 E. CROWN POINT RD.SUITE 1080WINTER GARDEN, FL. 34787PHONE: (407) 347-9614INFO@RAPIDBUILDINGSOLUTIONS.COMSP2.01:40 SITE PLAN LEGEND 40200 40 ( IN FEET ) 1 inch = ft. GRAPHIC SCALE ELEVATIONS BASED ON NAVD 88 VERTICAL DATUM 10' RIGHT OF WAY TAKING VACANT LAND LOCATION OF EXISTING FIRE HYDRANTLOCATION OF EXISTING STORM MANHOLE DATUM CONVERSION: NGVD29 - 1.509' = NAVD 88 EXISTING SIDEWALK LOCATION OF EXISTING STORM MANHOLE LOCATION OF EXISTING STOP SIGN LOCATION OF EXISTING WATER VALVES LOCATION OF EXISTING WATER VALVES LOCATION OF EXISTING SANITARY SEWER MANHOLE LOCATION OF CABLE TELEVISION BOX PROPOSED DUMPSTER LOCATION LAND USE TABLE TAX PARCEL #: 1313-232-0002-000-1 LOCATION:SE CORNER TURNPIKE FEEDER RD & MIRAMAR AVENUE ZONING DISTRICT:COMMERCIAL GENERAL (CG) FUTURE LAND USE:COMMERCIAL (COM) CURRENT LAND USE: COMMERCIAL / RESIDENTIAL MULTIPLE-FAMILY (COM/RM) ADJACENT ZONING (NORTH): COMMERCIAL NEIGHBORHOOD (CN) ADJACENT ZONING (SOUTH): COMMERCIAL GENERAL (CG) ADJACENT ZONING (EAST):RM-9 (RESIDENTIAL MULTIPLE FAMILY) ADJACENT ZONING (WEST):COMMERCIAL NEIGHBORHOOD (CN) PROPOSED BUILDING SETBACKS REQUIRED/PERMITTED PROPOSED FRONT(WEST):25' (MIN)25.00' REAR (EAST):10' (MIN) 207.65' SIDE (NORTH): 20' (MIN) 59.05' SIDE AT CORNER (SOUTH):20' (MIN) 59.75' LANDSCAPE BUFFER FRONT(WEST):15' (MIN) 25.00' REAR (EAST):10' (MIN) 20.00' SIDE (NORTH): 15' (MIN) 26.21' SIDE AT CORNER (SOUTH):10' (MIN) 22.79' TOTAL LOT AREA (ACRES):±194,885 SF 4.47 ACRES 100% IMPERVIOUS AREA (TOTAL)±115,216 SF 2.64 ACRES 59.10% PROPOSED BUILDING ±34,400 SF 0.79 ACRES 17.65% PROPOSED COVERED RV/BOAT ±27,913 SF 0.64 ACRES 14.32% PROPOSED CONCRETE ±2,633 SF 0.06 ACRES 1.35% PROPOSED PAVEMENT ±50,240 SF 1.15 ACRES 25.78% PERVIOUS AREA ±79,699 SF 1.83 ACRES 40.90% STORAGE UNITS:725 TOTAL UNITS PARKING STALLS:0.14 SPACES PER 1,000 SF OF GFA 103,200 / 1,000 = 14 STALLS REQUIRED 14 STALLS PROPOSED (3 SPACES OF THE 14 ARE FOR RV/BOAT PARKING) BUILDING GROSS FLOOR AREA:NA 103,200 SF FLOOR AREA RATIO :NA ±0.53 MAX BUILDING COVERAGE: 50%±31.97% (INCLUDES COVERED RV/BOAT STORAGE) LOT WIDTH:100 (MIN)±423' PRIMARY BUILDING HEIGHT:60' MAX ±46.5' FEMA:FLOOD ZONE X FIRM PANEL #: 12111C0070J DATED FEBRUARY 19, 2020, ST. LUCIE COUNTY, FL THE REQUIRED PARKING RATIO FOR ITE LAND USE CODE 151 (MINI-WAREHOUSE) IS AS FOLLOWS: REQUIRED PROPOSED WEEKDAY: 1.36 PARKING / 100 STORAGE UNITS 725 /100 = 7.25 X 1.36 = 9.86 10 12 + 2 HANDICAP SPACES OR WEEKDAY: 0.10 PARKING / 1,000 S.F.GFA 103,200 / 1,000 = 103.2 X 0.10 = 10.32 11 12 + 2 HANDICAP SPACES OR WEEKDAY: 1.57 PARKING / EMPLOYEES 1.57 X 2 = 3.14 3 12 + 2 HANDICAP SPACES GENERAL DEVELOPMENT NOTES PHASING:THE SITE IMPROVEMENTS SHOWN HEREIN ARE TO BE CONSTRUCTED IN A SINGLE PHASE WATER:ST LUCIE COUNTY UTILITIES WASTEWATER: ST LUCIE COUNTY UTILITIES ELECTRIC:FLORIDA POWER AND LIGHT ST LUCIE COMMERCIAL DESIGN STANDARDS:COMPLIANCE WITH ST LUCIE COUNTY COMMERCIAL DESIGN STANDARDS SIGN PLAN:COMPLIANCE WITH ST LUCIE COUNTY SIGNAGE ORDIANCE. LANDSCAPE ALL PROPOSED LANDSCAPING SHALL COMPLY TO ST LUCIE COUNTY LDC 7.09.00. PROJECT DIRECTORY DEVELOPER:STORAGE UNITS, LLC 350 E CROWN POINT ROAD, SUITE 1080 WINTER GARDEN, FL 34787 PHONE: (407) 347-9614 PHONE: (877) 917-2743 CIVIL ENGINEER:COMMON OAK ENGINEERING, LLC 1209 EDGEWATER DRIVE, SUITE 100 ORLANDO, FL 32804 PHONE: (407) 505-8374 GEOTECH ENGINEER:UNIVERSAL ENGINEERING SCIENCES, INC. 820 BREVARD AVENUE ROCKLEDGE, FL 32955 PHONE: (321) 638-0808 FAX: (321) 638-0978 SURVEYOR:STEPHEN J. BROWN, INC. 619 EAST 5TH STREET STUART, FLORIDA 34994 PHONE: (772) 288-7176 FAX: (772) 288-9995 PROPOSED 6" GRAVITY SANITARY LINE PROPOSED LIFT STATION PROPOSED 6" SANITARY FORCE MAIN PROPOSED FORCE MAIN CONNECTION PROPOSED ASPHALT PROPOSED FULL ACCESS DRIVEWAY PROPOSED FULL ACCESS DRIVEWAY PROPOSED TYPE D CURB GATE GATE VICINITY MAP PROJECT LOCATION DRAINAGE SYSTEM: DRAINAGE SYSTEM WILL CONSIST OF NEW STORMWATER INFRASTRUCTURE WHICH SHALL FLOW TO DRAINAGE AREA ON WESTERN PROPERTY AS SHOWN. TRAFFIC STATEMENT: THIS GENERALIZED TRAFFIC ANALYSIS WAS UNDERTAKEN IN SUPPORT OF A PROPOSED DEVELOPMENT CONSISTING OF A 103,200 SQUARE FOOT STORAGE FACILITY TO BE CONSTRUCTED ON A LOT TO BE CREATED FROM PARCEL ID#: 1313-232-0002-000-1, IN FT PIERCE, FLORIDA. ACCESS TO THE SITE WILL BE PROVIDED VIA A DRIVEWAY ON MIRAMAR AVENUE. THIS ANALYSIS ASSESSES THE POTENTIAL TRAFFIC GENERATION OF THE PROPOSED DEVELOPMENT, IN ACCORDANCE WITH FDOT STANDARDS. BASED ON THE PROPOSED USE, MINI WAREHOUSE (ITE CODE 81151) AND GENERATION FIGURES SUPPLIED BY THE TRANSPORTATION ENGINEER’S TRIP GENERATION REPORT, 9TH EDITION, THE PROPOSED PROJECT IS EXPECTED TO GENERATE 198 DAILY TRIPS AND 35 PEAK HOUR TRIPS AFTER PASS-BY TRIPS ARE TAKEN INTO ACCOUNT. TRIP GENERATION RATES FOR THE PROPOSED DEVELOPMENT WERE OBTAINED FROM THE INSTITUTE OF TRANSPORTATION ENGINEERS (ITE) TRIP GENERATION REPORT, 9TH EDITION. THE PASS-BY RATES WERE OBTAINED FROM THE ITE TRIP GENERATION HANDBOOK, 2ND EDITION. DRAINAGE NOTE: ALL DRAINAGE PIPE JOINTS, INCLUDING ROUND CONCRETE PIPES, SHALL HAVE A FILTER FABRIC JACKET IN ACCORDANCE WITH FDOT ROADWAY AND TRAFFIC DRAINAGE STANDARDS. ALL RCP PIPE USED FOR EXFILTRATION ARE TO HAVE SLOTS, IN ACCORDANCE TO FDOT INDEX #285.2 OPTION 'B'. PROPOSED STORM PIPE WITH EXFILTRATION (AS REQUIRED)(TYP) CONNECT TO EXISTING 8" WATER MAIN PROPOSED STORM STRUCTURE PROPOSED POINT OF CONNECTION FOR WATERLINE PROPOSED WATER LINE PROPOSED BIKE RACK PROPOSED 5' SIDEWALK PROPOSED CONNECTION TO EXISTING WET DETENTION POND NOTE: THE DEVELOPER SHALL PROVIDE THE ST. LUCIE COUNTY/FT. PIERCE FIRE DISTRICT AND ST. LUCIE COUNTY SHERIFF'S DEPARTMENT WITH ADEQUATE ACCESS CONTROL DEVICES OR KEYS TO PERMIT EMERGENCY ACCESS TO THE PROPERTY. PROPOSED CONTROL STRUCTURE SIGHT LIGHTING: LIGHTS SHALL BE SHIELDED TO DIRECT ANY CLARE AWAY FROM ADJACENT PROPERTIES OR STREETS & WILL CONFORM WITH SECTION 7.09.04(K) OF THE ST LUCIE COUNTY LAND DEVELOPMENT CODE. PROPOSED MONUMENT SIGN (1 OF 2) HEIGHT: > 30 FT SIGN AREA: 150 SF PROPOSED MONUMENT SIGN (2 OF 2) HEIGHT: > 30 FT SIGN AREA: 150 SF 1 EXISTING FULL ACCESS DRIVEWAY 1 1 1 PROPOSED FIRE SPRINKLER LINE CONNECTION TO THE BUILDING.LOCATION OF PROPOSED FDC LOCATION OF PROPOSED FIRE HYDRANT PROPOSED FIRE LINE 1 PROPOSED FENCE PROPOSED FENCE PROPOSED FENCE 335 LF DISTANCE. FROM EXISTING FIRE HYDRANT TO PROPOSED BUILDING END OF 8' TALL SCREEN WALL PER LDC 7.09.04E ±447.1 LF 8' TALL SCREEN WALL PER LDC 7.09.04E START OF 8' TALL SCREEN WALL PER LDC 7.09.04E END OF 8' TALL SCREEN WALL PER LDC 7.09.04E ±221.0 LF 8' TALL SCREEN WALL PER LDC 7.09.04E START OF 8' TALL SCREEN WALL PER LDC 7.09.04E TYPE "F" CURBTYPE "F" CURB 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2