Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFO11 R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FIlorida Department of Business and Professional Regulation - Residential Performance Method Projeck Name: Homecrete_Resendiz Sundse_Dr Builder Name: Homecrete Homes -ANNW B� Street:) Sunrise Dr Permit Office: City, State, Zip: Ft. Pierce , FL, 34945 Permit Number: tea} St Lude County Owner; Resendiz Residence Jurisdiction: Desigrj Location: FL, Fort Pierce ((construction 1. New or existing New (From Plans) 9. Wall Types(1554.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1218.70 ftz b. Frame -Steel, Adjacent R=13.0 336.00 ftz 3. Numbler of units, if multiple family 1 c. N/A R= ftz 4. Numb ler of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (1696.0 sgft.) Insulation Area a. Under Attic (Vented) R=38.0 1696.00 ft2 6. Conditioned floor area above grade (ftz) 1696 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz i 7. Windows(194.8 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ftz 6 132 a. U-Factor: Dbl, U=0.33 194.83 ftz SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:14.00 c. U-FIactor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 30.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.806 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1696.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab, On -Grade Edge Insulation R=0.0 1696.00 ftz b. Conservation features EF: 0.930 b. N/A R= ftz Add -on Dedicated HgatPump:COP=2.5 c. NIA R= ftz 15. Credits Pstat Glass/F�oor Total Proposed Modified Loads: 45.56 Area: 0.115 PASS Total Baseline Loads: 46.25 I hereby certify that the plans and specifications covered by Review of the plans and -V1dE STATE, this calculation are in compliance Florida Energy specifications covered by this O� Code. calculation indicates compliance �.,,, �'�%•, with the Florida Energy Code. ,.,�'.��VO .r,�,,, f� " `j O PREPARED BY: Before construction is completed _�•°•```�;, DATE: 2 / 3 / 2016 this building will be inspected for compliance with Section 553.908 Florida Statutes. I I herebyberti that d d, is in fyg ; , compliance the Florida Ene Mce. G'OD with WMF,O OWNER/AGENT: BUILDING OFFICIAL: DATE. / DATE: �(p - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test repoi in accordance with R402.4.1.2. i 2/3/20161:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software "0 a En •%i1.•. „ � �. •c i FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w t scat To Wall Type R-Value Et In Et In Area R-Value Fraction 1 E Exterior Concrete Block - Int Insul Main 5 10 8 80.0 ft2 -Abs 0 0.75 0 2 S Exterior Concrete Block - Int Insul Main 5 4 8 32.0 ft2 0 0.75 0 3 E Exterior Concrete Block - Int Insul Main 5 4 4 8 34.7 ft2 0 0.75 0 4 N Exterior Concrete Block - Int Insul Main 5 4 8 32.0 ft2 0 0.75 0 5 E Exterior Concrete Block - Int Insul Main 5 14 8 8 117.3 ft2 0 0.75 0 6 S Exterior Concrete Block - Int Insul Main 5 42 0 8 336.0 ft2 0 0.75 0 7 W Exterior Concrete Block - Int Insul Main 5 50 0 8 400.0 ft2 0 0.75 0 _ 8 N Exterior Concrete Block - Int Insul Main 5 23 4 8 186.7 ft2 0 0.75 0 _ 9 E Garage Frame - Steel Main 13 23 4 8 186.7 ft2 0.11 0.75 0 10 N Garage Frame - Steel Main 13 18 8 8 149.3 ft2 0.11 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.25 15.5 1`12 1 ft4 in 1 ft0 in Drapes/blinds None 2 E 3 Vinyl Low-E Double Yes 0.33 0.25 19.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 E 5 Vinyl Low-E Double Yes 0.33 0.26 15.5 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None i 4 S 6 Vinyl Low-E Double Yes 0.33 0.25 31.0 ft2 1 ft4 in 1 ft0 in Drapes/blinds None 5 W 7 Vinyl Low-E Double Yes 0.33 0.25 46.5 ft2 1 ft4 in 1 ft0 in Drapes/blinds None 6 W 7 Vinyl Low-E Double Yes 0.33 0.25 58.5 ft2 1 ft4 in 1 ft0 in Drapes/blinds None 7 N 8 Vinyl Low-E Double Yes 0.33 0.25 8.3 ft2 1 ft 4 in 1 ft0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 387.0015 ft2 384 ft2 39 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1130.7 62.07 116.74 .1855 5 1 2/3/20161:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 V FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 30 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 I Central Unit None SEER: 14 30 kBtu/hr 900 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50 gal 60 gal 120 deg Add -on HeatPump:COP=2.5 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None I ft2 DUCTS -- Supply --- --- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 132 ft2 Attic 18 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Progra able Thermostat: Y Ceiling Fans: CoolingJan HeatinH Feb Mar Jan Feb Mar Apr Apr Jun riJul Jun Jul May rl May X Aug � Aug Se Sep Oct Nov Dec X Jun Jul L Aug Sep Oct X Nov DecVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 1 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling EH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 1 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 2/3/2016 1:01 PM I EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 "II 4 I FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit) Office: Jurisdiction: FamilylType: New/Existing: Comment: I Homecrete_Resendiz_Sunds Bedrooms: 3 User Conditioned Area: 1696 Resendiz Residence Total Stories: 1 1 Worst Case: No Homecrete Homes Rotate Angle: 0 Cross Ventilation: Whole House Fan: Single-family New (From Plans) Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Sunrise Dr St. Lucie Ft. Pierce , FL, 34945 i CLIMATE / Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume I 1 Block) 1696 13568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1696 13568 Yes 1 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 154 ft 0 1696 ftZ 1 0 0 ROOF / # Type Roof Gable Roof Materials Area Area Color Solar Absor, SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) I 1 Hip Composition shingles 1837 ftz 0 ftz Medium 0.96 No 0.9 No 0 22.6 ATTIC V I # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 I Full attic Vented 300 1696 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 I Under Attic (Vented) Main 38 1696 ft' 0.11 Wood 2/3/2016 1:01 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. Sunrise Dr, Ft. Pierce, FL, 34945 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows" Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1218.70 ftz b. Frame - Steel, Adjacent R=13.0 336.00 ftz 1 c. N/A R= ftz 3 d. N/A R= ftz No 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=38.0 1696.00 ftz 1696 b. N/A R= ftz Area c. N/A R= ftz 194.83 ftz 11. Ducts R ftz a. Sup: Attic, Ret: Attic, AH: Garage 6 132 ftz 12. Cooling systems kBtu/hr Efficiency ftz a. Central Unit 30.0 SEER:14.00 ftz 1.800 ft. 0.250 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1696.00 ftz b. N/A R= ftz c. N/A R= ftz 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features Add -on Dedicated HeatPump:COP=2.5 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through th bove energy saving features which will be installed (or exceeded) in this home before fin I i spection. Otherwise, a new EPL Display Card will be completed based on installed C c pl an res. Builder Signature: Date: Address of New Home:a23 l S19oet6�F_ pm tl-gz_ City/FL Zi : �j1E7 ?VEM T-L 24? kBtu/hr Efficiency 30.0 HSPF:8.20 Cap: 50 gallons EF: 0.93 Pstat yo�zaE so� loll : ii,F �c'w�ti � rti�i G *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM), incentives if you obtain a Florida EnergyGauge Rating, Contact the EnergyGauge Hotline at (321) 638-1492 or se0he EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/3/2016 1:01 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software ag 1 of