HomeMy WebLinkAboutENERGY EFFICIENCY CODEFO11 R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FIlorida Department of Business and Professional Regulation - Residential Performance Method
Projeck Name: Homecrete_Resendiz Sundse_Dr
Builder Name: Homecrete Homes
-ANNW B�
Street:) Sunrise Dr
Permit Office:
City, State, Zip: Ft. Pierce , FL, 34945
Permit Number:
tea}
St Lude County
Owner; Resendiz Residence
Jurisdiction:
Desigrj Location: FL, Fort Pierce
((construction
1. New or existing New (From Plans)
9. Wall Types(1554.7 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1218.70 ftz
b. Frame -Steel, Adjacent
R=13.0 336.00 ftz
3. Numbler of units, if multiple family 1
c. N/A
R= ftz
4. Numb ler of Bedrooms 3
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (1696.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=38.0 1696.00 ft2
6. Conditioned floor area above grade (ftz) 1696
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
i
7. Windows(194.8 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ftz
6 132
a. U-Factor: Dbl, U=0.33 194.83 ftz
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
30.0 SEER:14.00
c. U-FIactor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
30.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.806 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1696.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab, On -Grade Edge Insulation R=0.0 1696.00 ftz
b. Conservation features
EF: 0.930
b. N/A R= ftz
Add -on Dedicated HgatPump:COP=2.5
c. NIA R= ftz
15. Credits
Pstat
Glass/F�oor
Total Proposed Modified Loads: 45.56
Area: 0.115
PASS
Total Baseline Loads: 46.25
I hereby certify that the plans and specifications covered by
Review of the plans and
-V1dE STATE,
this calculation are in compliance Florida Energy
specifications covered by this
O�
Code.
calculation indicates compliance
�.,,, �'�%•,
with the Florida Energy Code.
,.,�'.��VO
.r,�,,, f� " `j O
PREPARED BY:
Before construction is completed
_�•°•```�;,
DATE: 2 / 3 / 2016
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
I
I herebyberti that d d, is in
fyg
; , compliance
the Florida Ene Mce.
G'OD
with
WMF,O
OWNER/AGENT:
BUILDING OFFICIAL:
DATE. /
DATE:
�(p
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test repoi in accordance with R402.4.1.2.
i
2/3/20161:01 PM
EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
"0
a
En
•%i1.•. „ � �.
•c
i
FORM R405-2014
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Belo w
t
scat
To
Wall Type
R-Value Et In
Et In
Area
R-Value
Fraction
1
E
Exterior
Concrete Block - Int Insul
Main
5 10
8
80.0 ft2
-Abs
0 0.75
0
2
S
Exterior
Concrete Block - Int Insul
Main
5 4
8
32.0 ft2
0 0.75
0
3
E
Exterior
Concrete Block - Int Insul
Main
5 4 4
8
34.7 ft2
0 0.75
0
4
N
Exterior
Concrete Block - Int Insul
Main
5 4
8
32.0 ft2
0 0.75
0
5
E
Exterior
Concrete Block - Int Insul
Main
5 14 8
8
117.3 ft2
0 0.75
0
6
S
Exterior
Concrete Block - Int Insul
Main
5 42 0
8
336.0 ft2
0 0.75
0
7
W
Exterior
Concrete Block - Int Insul
Main
5 50 0
8
400.0 ft2
0 0.75
0
_ 8
N
Exterior
Concrete Block - Int Insul
Main
5 23 4
8
186.7 ft2
0 0.75
0
_ 9
E
Garage
Frame - Steel
Main
13 23 4
8
186.7 ft2
0.11 0.75
0
10
N
Garage
Frame - Steel
Main
13 18 8
8
149.3 ft2
0.11 0.75
0
DOORS
#
Omt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Wood Main
None
.46
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID
Frame Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
E 1
Vinyl Low-E Double
Yes
0.33 0.25
15.5 1`12
1 ft4 in
1 ft0 in
Drapes/blinds
None
2
E 3
Vinyl Low-E Double
Yes
0.33 0.25
19.5 ft2
6 ft 0 in
1 ft 0 in
Drapes/blinds
None
3
E 5
Vinyl Low-E Double
Yes
0.33 0.26
15.5 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
i 4
S 6
Vinyl Low-E Double
Yes
0.33 0.25
31.0 ft2
1 ft4 in
1 ft0 in
Drapes/blinds
None
5
W 7
Vinyl Low-E Double
Yes
0.33 0.25
46.5 ft2
1 ft4 in
1 ft0 in
Drapes/blinds
None
6
W 7
Vinyl Low-E Double
Yes
0.33 0.25
58.5 ft2
1 ft4 in
1 ft0 in
Drapes/blinds
None
7
N 8
Vinyl Low-E Double
Yes
0.33 0.25
8.3 ft2
1 ft 4 in
1 ft0 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
387.0015 ft2 384 ft2
39 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254
1130.7 62.07 116.74
.1855
5
1
2/3/20161:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
V
FORM R405-2014
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
None
HSPF:8.2
30 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
I
Central Unit
None
SEER: 14
30 kBtu/hr
900 cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric None
Garage
0.93 50 gal 60 gal
120 deg
Add -on HeatPump:COP=2.5
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart
# Company Name
System Model # Collector
Model # Area
Volume
FEF
None None
I
ft2
DUCTS
-- Supply ---
--- Return —
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 132 ft2
Attic
18 ft2 Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
Progra able Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinH
Feb Mar
Jan Feb Mar
Apr
Apr
Jun riJul
Jun Jul
May rl
May
X Aug
� Aug
Se
Sep
Oct
Nov
Dec
X
Jun Jul
L Aug
Sep
Oct
X Nov
DecVenting
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
1
Cooling (WD)
AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling EH)
AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68
68
68
68
68
68
1
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating(WEH)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
1
2/3/2016 1:01 PM
I
EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
Page 4 of 4
"II
4 I
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit) Office:
Jurisdiction:
FamilylType:
New/Existing:
Comment:
I
Homecrete_Resendiz_Sunds Bedrooms: 3
User Conditioned Area: 1696
Resendiz Residence Total Stories: 1
1 Worst Case: No
Homecrete Homes Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
Sunrise Dr
St. Lucie
Ft. Pierce ,
FL, 34945
i
CLIMATE
/
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
I
1
Block)
1696 13568
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1696 13568 Yes 1
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 154 ft 0
1696 ftZ
1 0 0
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor,
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
I
1
Hip Composition shingles 1837 ftz 0 ftz Medium
0.96
No 0.9
No 0 22.6
ATTIC
V I #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
I
Full attic
Vented 300 1696 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
I
Under Attic (Vented)
Main 38 1696 ft'
0.11
Wood
2/3/2016 1:01 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
Sunrise Dr, Ft. Pierce, FL, 34945
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows" Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.25
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0
1218.70 ftz
b. Frame - Steel, Adjacent
R=13.0
336.00 ftz
1
c. N/A
R=
ftz
3
d. N/A
R=
ftz
No
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=38.0
1696.00 ftz
1696
b. N/A
R=
ftz
Area
c. N/A
R=
ftz
194.83 ftz
11. Ducts
R ftz
a. Sup: Attic, Ret: Attic, AH: Garage
6 132
ftz
12. Cooling systems
kBtu/hr
Efficiency
ftz
a. Central Unit
30.0 SEER:14.00
ftz
1.800 ft.
0.250
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1696.00 ftz
b. N/A R= ftz
c. N/A R= ftz
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
Add -on Dedicated HeatPump:COP=2.5
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through th bove energy saving features which will be installed (or exceeded)
in this home before fin I i spection. Otherwise, a new EPL Display Card will be completed
based on installed C c pl an res.
Builder Signature: Date:
Address of New Home:a23 l S19oet6�F_ pm tl-gz_ City/FL Zi : �j1E7 ?VEM T-L
24?
kBtu/hr Efficiency
30.0 HSPF:8.20
Cap: 50 gallons
EF: 0.93
Pstat
yo�zaE so�
loll : ii,F �c'w�ti
� rti�i G
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM), incentives if you obtain a Florida EnergyGauge Rating, Contact the EnergyGauge Hotline at (321)
638-1492 or se0he EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/3/2016 1:01 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software ag 1 of