HomeMy WebLinkAboutINSULATION INSTALLATION CERTIFICATEECEIVED
DEC 2 7 2016a
PERMITTING INSULATION INSTALLATION CERTIFICATE
t. Lucie County, FL
TO: Homecrete Homes LOT BLOCK: SECTION:
JOB#: 108496 JOB NAME: Resendiz Res
JOB ADDRESS: 231 Sunrise Dr
The undersigned hereby certifies that insulation has ,been installed ate above described property as SCANNE®
follows: BY
1. Exterior CBS wails have been insulated with ............................Check one () Spray on cellulose St Lucie County
to a thickness of N/A inches, which thickness, according to the Fiberglass blankets
manufacturer, () Aluminum Foil
Density N/A will yield an "R" value of () Riaid
Exterior Frame walls have been insulated with ............................Check one
( ) Spray on cellulose
to a thickness of
inches, which thickness, according to the
( ) Fiberglass blankets
manufacturer,
P jAluminum Foil
Density N/A
will yield an "R" value of
( ) Other Spray Foam
2. Main Ceilings have
been insulated with .........................Check one
( ) Fiberglass blankets
to a thickness of 12.75
inches, which thickness, according to the
M Fiberglass loose fill
manufacturer,
Propink
( ) Aluminum Foil
Density N/A
will yield an "R" value of 38
Other I Cellulose
Ceilings Cathedral
have been insulated with .........................Check one
O Fiberglass blankets
to a thickness of 12.75
inches, which thickness, according to the
Fiberglass loose fill
manufacturer,
Propink
( ) Aluminum Foil
Density N/A
will yield an "R" value of38
( ) Other Cellulose
3. Interior knee walls have been insulated with.................................Check one
(X) Fiberglass blankets
to a thickness of 12
inches, which thickness, according to the
( ) Polyurethane
manufacturer,
Certainteed
( ) Spray on cellulose
Density N/A
will yield an "R" value of 38
( ) Other Spray Foam
4. Garage partition walls of conditioned living areas have been
insulated with ............................ ..........:......................................Check one (x) Fiberglass blankets
to a thickness of 3.5 inches, which thickness, according to the ( ) Spray on cellulose
manufacturer, Certainteed ( ) Polyurethane
Density N/A will yield an "R" value of 13 ( ) Other Aluminum Foil
MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating
different tenants shall be insulated as follows - FrameJMetal stud walls R-I I (Min.); CBS or Concrete walls
R-3 (Min.); by Energy Code requirements. See Energy Code Rev. I/87, paragraph 903.2(b), on page 9.17,
latest edition. These "minimums levels of insulation" are not included in the Energy Calculations, but shall
be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F.
(lb/R3) average of three (3) "DRY SAMPLES" of actual installatio
MER Enterprises LLC
Insulation Contractor Insulation Contractor Signature
26202
Insulation Contractor's CC#
11/29/16
Date of Certification
Builder's Name - Builder's CC# P I c
KELLY L YOUNG
>R a",'��;� Notary Public - State of Florida
oaf = My Comm. Expires Jul 1, 2018
y' Commission # FF 138101