Loading...
HomeMy WebLinkAboutINSULATION INSTALLATION CERTIFICATEECEIVED DEC 2 7 2016a PERMITTING INSULATION INSTALLATION CERTIFICATE t. Lucie County, FL TO: Homecrete Homes LOT BLOCK: SECTION: JOB#: 108496 JOB NAME: Resendiz Res JOB ADDRESS: 231 Sunrise Dr The undersigned hereby certifies that insulation has ,been installed ate above described property as SCANNE® follows: BY 1. Exterior CBS wails have been insulated with ............................Check one () Spray on cellulose St Lucie County to a thickness of N/A inches, which thickness, according to the Fiberglass blankets manufacturer, () Aluminum Foil Density N/A will yield an "R" value of () Riaid Exterior Frame walls have been insulated with ............................Check one ( ) Spray on cellulose to a thickness of inches, which thickness, according to the ( ) Fiberglass blankets manufacturer, P jAluminum Foil Density N/A will yield an "R" value of ( ) Other Spray Foam 2. Main Ceilings have been insulated with .........................Check one ( ) Fiberglass blankets to a thickness of 12.75 inches, which thickness, according to the M Fiberglass loose fill manufacturer, Propink ( ) Aluminum Foil Density N/A will yield an "R" value of 38 Other I Cellulose Ceilings Cathedral have been insulated with .........................Check one O Fiberglass blankets to a thickness of 12.75 inches, which thickness, according to the Fiberglass loose fill manufacturer, Propink ( ) Aluminum Foil Density N/A will yield an "R" value of38 ( ) Other Cellulose 3. Interior knee walls have been insulated with.................................Check one (X) Fiberglass blankets to a thickness of 12 inches, which thickness, according to the ( ) Polyurethane manufacturer, Certainteed ( ) Spray on cellulose Density N/A will yield an "R" value of 38 ( ) Other Spray Foam 4. Garage partition walls of conditioned living areas have been insulated with ............................ ..........:......................................Check one (x) Fiberglass blankets to a thickness of 3.5 inches, which thickness, according to the ( ) Spray on cellulose manufacturer, Certainteed ( ) Polyurethane Density N/A will yield an "R" value of 13 ( ) Other Aluminum Foil MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating different tenants shall be insulated as follows - FrameJMetal stud walls R-I I (Min.); CBS or Concrete walls R-3 (Min.); by Energy Code requirements. See Energy Code Rev. I/87, paragraph 903.2(b), on page 9.17, latest edition. These "minimums levels of insulation" are not included in the Energy Calculations, but shall be installed in the field. NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F. (lb/R3) average of three (3) "DRY SAMPLES" of actual installatio MER Enterprises LLC Insulation Contractor Insulation Contractor Signature 26202 Insulation Contractor's CC# 11/29/16 Date of Certification Builder's Name - Builder's CC# P I c KELLY L YOUNG >R a",'��;� Notary Public - State of Florida oaf = My Comm. Expires Jul 1, 2018 y' Commission # FF 138101