Loading...
HomeMy WebLinkAboutKSM REPORTSi KE 4ER, SCHLEICHER & MaCWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78_1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 . www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED july 5 2016 KSM JOB # : 161716-1d/SF/aj EMIT # 1603-0027 SCANNED CONTRACTOR Homecrete Homes BY St Lucie County JO LOCATION 231 Sunrise Drive I Ft. Pierce, Florida ITEM TESTED Compacted Foundation Fill- House Pad I EST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. S.W. 0" - 12" 47 114.8 116.0 99.0 2. S.E. 44 113.9 98.2 3. Center 48 115.1 99.2 4. N.E. 46 114.7 98.9 5. N.W. 46 114.3 98.5 So'I Description: Brown and with Shell Fragments In Place Moisture: 11.1 Percent Optimum Moisture: 11.0 Percent Max. Dry Density: 116.0 P.C,F. Test Locations The De sity & Penetrometer Re�dings Indicate the Degree of � Mirimugq�p�d�fi6ktciyl��ets �r� e ! s �ct� le i Julie C-1 i ail Fax ,cen to atuwl Grade. t F w 117.0 I I I I I W E I I I I I I I I I t I I I G 116.0 H T I I I I I I P I I I I 115.0 C I I I I I I I I I I F I I I I I 114.0=_.._..•_.._. D I I I I I I R I I I I I I Y 113.0 8 9 10 11 k t;} 13 14 Moisture - % of Dry Wei JUL 9 3) 2016 Pub'N St. Lucie C;ou r -n r or Fianomes.com alfvt/� I or Department Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 07/07/2016 11:30 77258964691-1 KSM ENGINEERING PAGE 01/01 %F O IL 9 KEL LER, SCHLEICHER & MaCWIL.LIAM ENGINEERING AND ET S TIN , INC. MARTIN (772) 337-7755 P.O. BOX 78^1 377, SEBASTIAN, FL 32978-1377 MELSOURNE (321) 768-8468 PALM BEACH (561) 845-7445 www.ksmangineering.net S-r LUCIE (772) 229-9093 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET FAX (772) 589-6469 G.A. 5693 SOIL COMPACTION REPORT ASTM D 1657 and ASTM D 2922 TE TESTED : July 5, 2016 KSM JOB#: 161715-ld/SF/aj # �6a LA-�7,r: ZERMIT�' SCANNED CONTRACTOR Homecrete Homes BY at Lucie County JAB LOCATION 231 Sunrise Drive Ft. Pierce, Florida ITEM TESTED Compacted Foundation Fill- House Pad TEST LOCATION DEPTH "PEN DRY READ DENSITY MAX. DRY PERCENT PROCTOR VALUE COMPACTION OF SAMPLE 1. S.W. 0ll - 12" 47 114.8 116.0 911 9.2 2. S.E. 44 113.9 if 99. 3. Center 48 115.1 98.9 4. N.E. 46 114.7 98.5 5. N.W. 46 114.3 Soil Description: 117.0 I I I I I Brown Sand with Shell Fragments W E 4 I In Place Moisture; 1 I I I I 11.1 percent H 116,0 I T Optimum Moisture: l I I I I I 11, 0 Percent p115.0 l l Max. Dry Density: C I I 1 I I I P.C.F. �116.0 F i@ Test Locations The 114.0 Density & Penetrometer j 1 I I I I Readings Indicate the R Degree of C�Q%��fit�11 ajll�ets Y 113.0 Minlmur�IQlk dA.?f��i� g 9 1 Q 11 12 13 14 Unstak * Pe " en ca !'. at l r)�I Grade. Moisture - % of Dry Weight espctfwllylo I r Julie-, �>�r; ,��� RECEIVED JUL 071016 ..: E- ail homes.com Fax aifi4►� I IoI Building Department Ronald G. Keller, P.E.. $7293 / SI Lio, No.: 860 / Julie E. Keller, P.E.: 68366