Loading...
HomeMy WebLinkAboutPROJECT SUMMARYi -- rightsoft® Project Summary Jo MJD16020216 Entire House By: Bruce Tschosik Energy House Technology 3341 Pine Hill Trail, Palm Beach Gardens, FL33418 Phone: 561-459-0242 Email: Bruce@EnergyHT.com Web: www.EnergyHT.com License: 927 For: Brian Roat c/o Resendiz Residence, Homecrete Homes Sunrise Dr, Ft. Pierce, FL Phone:772-370-0136 Email: broat@homecretehomes.com Notes: SCANN5D BY St Lucie County Weather: Fort Pierce, FL, US i Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 15415 Btuh Ducts 4511 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh iping 0 Btuh quipment load 19926 Btuh Infiltration Method Construction quality Fireplaces Area (ft2 Volume ft3) Air changes/hour IEquiv. AVF (cfm) Simplified Average 0 Heating Cooling 1700 1700 13600 13600 0.38 0.20 86 45 Heating Equipment Summary Make CARRIER Vade Model CH14NA03000G AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow �4ir flow factor Static pressure Space thermostat 8.2 HSPF 24000 Btuh @ 47OF 27 OF 807 cfm 0.041 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 14277 Btuh Ducts 4864 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 18184 Btuh Latent Cooling Equipment Load Sizing Structure 4494 Btuh Ducts 1877 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 6371 Btuh Equipment total load 24555 Btuh Req. total capacity at 0.70 SHR 2.2 ton Cooling Equipment Summary Make CARRIER Trade Cond CH14NA03000G Coil FB4CNP030L00 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12.5 EER, 14 SEER 19670 Btuh 8430 Btuh 28100 Btuh 807 cfm 0.042 cfm/Btuh 0.50 in H2O 0.75 _ Calculations approved by ACCA to meet all requirements of Manual J 8th - a wrightsoft' Right-Sulte® Universal 2015 15.0.25 RSU11733 ... ft HVAC\Homecrete_HomeS_Resendiz Sunrise_Dr.rup Calc = MJ8 Front Door faces: E 07:40:27 Page 1 1 ® Duct System Summary Job: MJD16020216 -- wrightsoft Date: Entire House By: Bruce Tschoslk Energy House Technology 3341 Pine Hill Trail, Palm Beach Gardens, FL33418 Phone: 561-459-0242 Email: Bruce@EnergyHT.com Web: www.EnergyHT.com License: 927 For: Brian Roat c/o Resendiz Residence, Homecrete Homes Sunrise Dr, Ft. Pierce, FL Phone:772-370-0136 Email: broat@homecretehomes.com External static pressure Pressure losses Available static pressure Su / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Beating 0.50 in H2O 0.29 in H2O 0.21 in H2O 0.173 / 0.037 in H2O 0.049 in/100ft 807 cfm Cooling a50 in H2O 0.29 in H2O 0.21 in H2O 0.173 / 0.037 in H2O 0.049 in/ 100ft 807 cfm 431 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 h 651 26 10 0.049 4.0 Ox 0 VIFx 28.1 325.0 st6 Bedroom 2 h 2906 118 78 0.049 6.0 Ox 0 VIFx 29.2 325.0 st6 Bedroom 3 Bedroom 4 h 2224 90 60 0.115 6.0 Ox 0 VIFx 9.8 140.0 stl h 3551 144 77 0.082 8.0 Ox 0 VIFx 24.6 185.0 st3 Dining C 1627 60 69 0.052 6.0 Ox 0 VIFx 20.1 310.0 st3A Great Room C 5457 108 230 0.052 10.0 Ox 0 VIFx 18.2 315.0 st3 I(itchen C 2822 45 119 0.055 6.0 Ox 0 VIFx 10.8 305.0 st3A Laundry h 341 14 12 0.089 4.0 Ox 0 VIFX 8.1 185.0 st3 Master BR h 3573 145 109 0.092 8.0 Ox 0 VIFX 23.0 165.0 st2 Master Bath h 1265 51 24 0.094 4.0 Ox 0 VIFx 18.8 165.0 st2 WIC c 466 6 20 0.094 4.0 Ox 0 VIFx 19.5 165.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 202 152 0.092 578 8.0 0 x 0 VinlFix st1 st3A Peak AVF 249 276 0.049 496 10.4 10 x 8 RectFbg st3 st6 Peak AVF 144 88 0.049 539 7.0 0 x 0 VinlFlx st3A st3 Peak AVF 515 595 0.049 510 13.8 12 x 14 RectFbg stl stl Peak AVF 807 807 0.049 538 15.5 12 x 18 RectFbg Bold/Italic values have been manually overridden wri htSOft' 2016-Feb-18 07:40:27 g Right -Suite® Universal 2015 15.0.25 RSU11733 ...ft HVAC\Homecrete_Homes_Resendiz Sunrise_Dr.rup Cale = MJ8 Front Door faces: E Page 1 Grill Htg Glg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 807 807 76.5 0.049 454 15.0 1 bk 16 RtFg Bold/italic values have been manually overridden ti + wrightsoft® Right -Suite® Universal 2015 15.0.25 RSU11733 2016-Feb-18 07:40:27 Page 2 ...11 HVAC\Homecrete_Homes_Resendiz Sunrise_Dr.rup Cale = MJ8 Front Door faces: E