FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION SCA�NNeD
Form R405 Duct Leakage Test Report
Performance Method St Lucie County,
Projects Name: Lot7TarponFlatsModeIBGLNE Builder Name: PHOENIX REALTY HOMES
Street: 1 3913 Shoreside Drive Permit Office:
City, State, Zip: Fort Pierce, FL , 34949 Permit Number:
Design; Location: FL, ST_LUCIE_CO_INTL Jurisdiction: 661000
Duct Test Time: Post Construction
Duct Leakaae Test Results-
CFM25 Duct Leakage Test Values
Line
System
Outside Duct Leakage
1
System 1
cfm25(Out)
2
System 2
cfm25(Out)
3
System 3
cfm25(Out)
4
System 4
cfm25(Out)
5
Total House
Sum lines 1-4
Duct System
Divide by
Leakage
(Total Conditioned Floor Area)
_ (()n,Out)
I certify the tested duct leakage to outside, Qn, is
not greater than the proposed duct leakage Qn
specified on Form R405-2014.
SIGNATURE: \
PRINTED NAME:
DATE:
Duct tightness shall be verified by
testing to Section 803 of the RESNET
Standards by an energy rater certified in
accordance with Section 553.99,
Florida Statutes.
BUILDING OFFICIAL:
DATE:
7/28/201610:57 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 ComplijWt-SI JWa W Mqe 1 of 1
FORM R405-2014
I
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Fli rida Department of Business and Professional Regulation - Residential Performance Method
Projec, Name: Lot7TarponFlatsModeIBGLNE
Builder Name: PHOENIX REALTY HOMES
Street:, 3913 Shoreside Drive
Permit Office:
City, Sate, Zip: Fort Pierce, FL, 34949
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3182.7 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 2954.00 ftz
b. Frame - Wood, Adjacent
R=13.0 228.67 ft2
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 4
d. WA
R= ftz
Is
10. Ceiling Types (1959.0 sgft.)
Insulation Area
5. this a worst case? No
a. Roof Deck (Unvented)
R=20.0 1959.00 ftz
6. Conditioned floor area above grade (ftz) 2669
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(640.4 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 391.8
a. U-Factor: Dbl, U=0.60 640.43 ftz
b. Sup: Attic, Ret: Attic, AH: Attic
6 142
SHGC: SHGC=0.32
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
40.0 SEER:14.00
c. U-Factor: N/A ftz
b. Central Unit
17.8 SEER:14.00
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: WA ftz
a. Electric Heat Pump
41.0 HSPF:8.20
SHGC:
b. Electric Heat Pump
17.6 HSPF:8.20
- Area Weighted Average Overhang Depth: 5.032 ft.
Area Weighted Average SHGC: 0.320
14. Hot water systems
8. Floor Types (2669.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1959.00 ftz
b. Conservation features
EF: 2.780
b. Floor Over Other Space R=0.0 710.00 ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.240 Total Proposed Modified Loads: 88.07
PASS
Total Baseline Loads: 87.90
I hereby
i
certify that the plans and specifications covered by
Review of the plans and
'Cins� r�
this calculation
are in compliance with the Florida Energy
specifications covered by this
O
, O
Code.
calculation indicates compliance
with the Florida Energy Code.
PREP
RED BY:
Before construction is completed
DATE:
n7/2R/2016
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
.,.. ;
hereby certify that this building, as designed, is in compliance
�y+�
with the Florida EnergA4)1_2tX2ffl_
OWNER/AGBUILDING
OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested Iin accordance with Section 803 of RESNET Standards, Is not greater than 0.030 On for whole house.
7/28/2016 10:55 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title:
Lot7TarponFlatsModeIBGLNE Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2669
Lot #
Owner:
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
PHOENIX REALTY
HOMES Rotate Angle: 0
Street:
3913 Shoreside
Drive
Permit'Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family!Type:
Single-family
FL, 34949
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp,
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST LUCIE_CO_INTL FL VERO BEACH_MUNI 2 39 90
70
75 299
58
Medium
BLOCKS
Number
Name
Area Volume
1
Blocki
1959 18218.7
2
Block2
710 6603
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
1st Floor
1959 18218.7 Yes 5
2
1 Yes
Yes
Yes
2
2nd Floor
710 6603 No 0
2
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio 1 st Floor 194.5 ft 0
1959 ft2
----
0.32 0
0.68
2 Floor Over Other Space
2nd Floor ---- ----
710 ft2
0
0.2 0
0.8
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
i
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
i
i 1
Hip
Metal 2191 ft2 0 ft2 Medium
0.65
N 0.65
No 20
26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 1959 ft2
N N
7/28/2016 10:55 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Unvented) 1st Floor
0
Blown
1249 ft2
0.11
Wood
2 Under Attic (Unvented) 2nd Floor
0
Blown
710 ft2
0.11
Wood
WALLS
Adjacent Space
Cavity
R-Vahle
Width
Et In
Height
Ft In
Are;;
Sheathing Framing Solar Below
R-V11-1e Erection Ahsor 0
_ 1
NW Exterior
Concrete Block - Int Insul 1st Floor
4.1
40
6
9 4
378.0 ft2
0
0 0.6
0
2
NW Exterior
Concrete Block - Int Insul2nd Floor
4.1
34
0
9 4
317.3 ft2
0
0 0.6
0
3
NE Exterior
Concrete Block - Int Insul 1st Floor
4.1
20
0
9 4
186.7 ft2
0
0 0.6
0
4
NE Exterior
Concrete Block - Int Insul2nd Floor
4.1
17
0
9 4
158.7 ft2
0
0 0.6
0
5
SE Exterior
Concrete Block - Int Insul 1 st Floor
4.1
47
0
9 4
438.7 ft2
0
0 0.9
0
6
j SE Exterior
Concrete Block - Int Insul2nd Floor
4.1
34
0
9 4
317.3 ft2
0
0 0.6
0
7
SW Exterior
Concrete Block - Int Insul 1st Floor
4.1
27
0
9 4
252.0 ft2
0
0 0.6
0
8
SW Exterior
Concrete Block - Int Insul2nd Floor
4.1
27
0
9 4
252.0 ft2
0
0 0.6
0
9
- Garage
Frame - Wood 1st Floor
13
24
6
9 4
228.7 ft2
0
0.23 0.01
0
10
NW Exterior
Concrete Block - Int Insul 1st Floor
4.1
10
9 4
93.3 ft2
0 0.6
0
11
NE Exterior
Concrete Block - Int Insul 1st Floor
4.1
10
9 4
93.3 ft2
0 0.6
0
12
NE Exterior
Concrete Block - Int Insul 1 st Floor"
4.1
8
9 4
74.7 ft2
0 0.6
0
.13
NE Exterior
Concrete Block - Int Insul2nd Floor
4.1
10
9 4
93.3 ft2
0 0.6
0
14
SW Exterior
Concrete Block - Int Insul 1st Floor
4.1
12
9 4
112.0 ft2
0 0.6
0
_ 15
SW Exterior
Concrete Block - Int Insul 1st Floor
4.1
20
9 4
186.7 ft2
0 0.6
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
Wood 1st Floor
None
.39
2
8
8
21.3 ft2
2 E
Wood 2nd Floor
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
# Ornt ID
Frame Panes NFRC
U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1 NW 1
Metal Low-E Double Yes
0.6
0.32
6.3 ft2
2 ft 0 in
0 ft 5 in
None
Exterior 5
2 NW 1
Metal Low-E Double Yes
0.6
0.32
28.4 ft2
2 It 0 in
0 It 5 in
None
Exterior 5
3 NW 2
Metal Low-E Double Yes
0.6
0.32
14.0 ft2
2 ft 0 in
0 ft 5 in
Drapes/blinds
Exterior 5
4 NW 10
Metal Low-E Double Yes
0.6
0.32
14.2 ft2
9 It 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
5 NE 3
Metal Low-E Double Yes
0.6
0.32
33.8 ft2
2 ft 0 in
0 ft 5 in
None
Exterior 5
6 NE 11
Metal Low-E Double Yes
0.6
0.32
32.7 ft2
2 ft 0 in
11 ft 9 in
None
Exterior 5
7 NE 12
Metal Low-E Double Yes
0.6
0.32
12.0 ft2
7 ft 0 in
0 It 2 in
None
None
8 NE 4
Metal Low-E Double Yes
0.6
0.32
14.0 ft2
2 ft 0 in
0 ft 5 in
Drapes/blinds
Exterior 5
9 NE 4
Metal Low-E Double Yes
0.6
0.32
32.4 ft2
2 It 0 in
0 ft 5 in
Drapes/blinds
Exterior 5
10 NE 13
Metal Low-E Double Yes
0.6
0.32
28.0 ft2
6 ft 4 in
0 ft 3 in
Drapes/blinds
Exterior 5
11 SE 5
Metal Low-E Double Yes
0.6
0.32
11.1 ft2
2 ft 0 in
0 ft 5 in
None
Exterior 5
12 SE 6
Metal Low-E Double Yes
0.6
0.32
4.0 ft2
2 ft 0 in
0 ft 5 in
None
None
13 SW 7
Metal Low-E Double Yes
0.6
0.32
33.8 ft2
2 ft 0 in
0 It 5 in
None
Exterior 5
7/28/201610:55 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame Panes NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
14
15
16
17
SW 7 Metal Low-E Double Yes
SW 15 Metal Low-E Double Yes
SW 14 Metal Low-E Double Yes
SW 8 Metal Low-E Double Yes
0.6 0.32 31.7 ft2 2 ft 0 in 0 ft 5 in None
0.6 0.32 144.0 ft2 2 ft 0 in 12 ft 0 in None
0.6 0.32 72.0 ft2 14 ft 4 in 0 ft 5 in None
0.6 0.32 128.0 ft2 8 ft 0 in 0 ft 5 in Drapes/blinds
Exterior 5
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
492 ft2 492 ft2
88.2 ft 9.3 ft 1
INFILTRATION
`
# Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000295
2068.5 113.56 213.56 .2728 5
HEATING SYSTEM
#
System Type Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump Split
Electric Heat Pump Split
HSPF:8.2 41 kBtu/hr 1
HSPF:8.2 17.6 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit Split
Central Unit Split
SEER: 14 40 kBtu/hr cfm 0.75 1
SEER: 14 17.8 kBtu/hr 534 cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType Location
EF Cap Use SetPnt Conservation
1
Electric Heat Pump Garage
2.78 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
i
Collector Storage
System Model # Collector Model # Area Volume FEF
None None
ft2
DUCTS
/
V #
---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC #
Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
2
Attic 6 391.8 ft Attic
Attic 6 142 ft2 Attic
97.95 ft Prop. Leak Free Attic --- cfm 58.8 cfm 0.03 0.60
35.5 ft2 Prop. Leak Free Attic --- cfm 21.3 cfm 0:03 0.60
1 1
2 2
7/28/2016 10:55 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
1
Cooling, Jan
Heating Jan
Feb
Feb
Mar
Mar
Apr r
Apr [
May
May f
Jun
Jun
Jul
f Jul
Au
Auf
Se
Sep E
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan
Feb
Mar
A r [
May [
Jun
[ Jul
Aug
l
Se lXJ
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM
Fan Wafts
HRV Heating System
Run Time
Cooling System
Runtime (Vent
58
0
0
1 - Electric Heat Pump
%
1 - Central Unit
7/28/2016 10:55 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM i R405-2014
ENERGY
PERFORMANCE LEVEL
(EPL)
•
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the, more efficient the home.
3913 Shoreside Drive, Fort Pierce, FL, 34949
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=4.1
2954.00 ftz
b. Frame - Wood, Adjacent
R=13.0
228.67 ftz
3. Number of units, if multiple family
1 c. WA
R=
ftz
4. Number of Bedrooms
4 d. N/A
R=
ftz
5. Is this a worst case?
No 10. Ceiling Types
Insulation
Area
I
a. Roof Deck (Unvented)
R=20.0
1959.00 ftz
6. Conditioned floor area (ftz)
2669 b. N/A
R=
ftz
7. Windows" Description
Area c. N/A
R=
ftz
• a. U Factor: Dbl, U=0.60
640.43 ftz 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ftz
6 391.8
SHGC: SHGC=0.32
b. Sup: Attic, Ret: Attic, AH: Attic
6 142
b. U-Factor: N/A
ftz
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ftz a. Central Unit
40.0 SEER:14.00
SHGC:
b. Central Unit
17.8 SEER:14.00
d.'U-Factor: N/A
i
SHGC:
ftz
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
Area Weighted Average Overhang Depth: 5.032 ft. b. Electric Heat Pump
"
41.0
17.6
HSPF:8.20
HSPF:8.20
Area Weighted Average SHGC:
0.320
8. Floori Types
Insulation Area 14. Hot water systems
Cap:
50 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1959.00 ftz a. Electric
b. Floor Over Other Space
R=0.0 710.00 ftz
EF: 2.78
c. N/A
R= ftz b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: �- Date:1 Z�l�
Addre,ssl of New Home City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see�the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/28/2016 10:56 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
• - wrightsoft® Manual S Compliance Report
Zone 1
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Design Conditions
Outdoor design DB:
90.5 OF
Outdoor design WB:
77.7°F
Indoor design DB:
75.0°F
• Indoor RH:
50%
Sensible gain:
30095
Btuh
Latent gain:
7454
Btuh
Total gain:
37549
Btuh
Estimated airflow:
1333
cfm
Manufacturer's Performance Data at Actual Design Conditions
" Equipment type:
Split ASHP
Manufacturer:
Carrier
Model: CH14NB042****A+FB4CNP042L
Actual airflow:
1333 cfm
Sensible capacity:
31095 Btuh
103% of load
Latent capacity:
10110 Btuh
136% of load
Total capacity:
41205 Btuh
110% of load SHR: 75%
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Entering coil DB: 75.9°F
Entering coil WB: 63.8°F
Outdoor design DB: 43.1 °F Heat loss: 29627 Btuh Entering coil DB: 68.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042L
Actual airflow: 1333 cfm
Output capacity: 40000 Btuh 135% of load
Supplemental heat required: 0 Btuh
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1333 cfm
Output capacity: 7.7 kW 89% of load Temp. rise: 48 °F
The above equipment was selected in accordance with ACCA,Manual S.
1wrightsoft° Right -Suite® Universal 2017 17.0.03 RSU24009
_
..TarponFlatsModelB\Lot7TarponFlatsModeIBGLNE.rup Calc = MJ8 House faces: NE
Capacity balance: 35 °F
Economic balance: -99 °F
11:30:25
Page 1
Manual S Compliance Report
wrightsoft- P P
Zone 2
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
Job: LOT 7TARPONFLATS M...
Date: Jan 29, 2016
By: RH
�
I
Project•
•
For: PHOENIX REALTY HOMES
Cooling Equipment
Design Conditions
Outdoor design DB:
90.5 °F Sensible gain: 12781
Btuh
Entering coil DB: 75.1 °F
Outdoor design WB:
77.7°F Latent gain: 1616
Btuh
Entering coil WB: 62.8°F
Indoor design DB:
75.0`F Total gain: 14397
Btuh
Indoor RH:
50% Estimated airflow: 593
cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type:
Split ASHP
Manufacturer:
Carrier
Actual airflow:
593 cfm
- Sensible capacity:
14100 Btuh
Latent capacity:
3329 Btuh
Total capacity:
17429 Btuh
Model: CH14NB018****A+FB4CNP018L
110% of load
206% of load
121% of load SHR: 81%
Outdoor design DB: 43.1 cF Heat loss: 12543 Btuh Entering coil DB: 69.9°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier
Model: CH14NB018****A+FB4CNP018L
Actual airflow: 593
cfm
Output capacity: 17800
Btuh 142% of load
Supplemental heat required:
0 Btuh
Backup equipment type:
Elec strip
Manufacturer:
Model:
Actual airflow: 593
cfm
Output capacity: 2.3
kW 63% of load Temp. rise: 41 `F
The above equipment was selected in accordance with ACCA Manual S.
Capacity balance: 35 OF
Economic balance: -99 `F
wri htsoft° 2016-Jul-2811:30:25
9 Right -Suite® Universal 2017 17.0.03 RSU24009 ...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc - MJ8 House faces: NE Page 2
wrightsoft® Component Constructions
Entire House
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Location:
Vero Beach Municipal AP, FL, US
Elevation: 30 ft
Latitude: 28 °N
Outdoor: Heating
Dry bulb (°F) 43
Daily range (OF) -
Wet bulb (OF) -
Wind speed (mph) 15.0
Indoor:
Indoor temperature (OF)
Design TD (OF)
Relative humidity (%)
Cooling
Moisture difference (gr/lb)
91
Infiltration:
16 ( L )
Method
78
Construction quality
7.5
Fireplaces
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Heating
70
27
30
-0.2
Simplified
Semi -tight
0
Cooling
75
16
50
58.7
Construction descriptions
Or
Area
U-value
Insul R
Htg HTM
Loss
Clg HTM
Gain
I
W
Btuh/fr�T
ffT TOW
BtuhM
BWh
Btuhrd2
Btuh
Walls)
13A-2ocs:13A-2ocs
ne
251
0.201
4.1
5.41
1358
4.04
1015
se
426
0.201
4.1
5.41
2301
4.04
1720
sw
268
0.201
4.1
5.41
1447
4.04
1081
nw
435
0.201
4.1
5.41
2352
4.04
1757
all
1379
0.201
4.1
5.41
7459
4.04
5573
13A-2ocs 2:13A-2ocs 2
ne
177
0.201
4.1
5.41
956
4.04
714
se
312
0.201
4.1
5.41
1688
4.04
1261
sw
123
0.201
4.1
5.41
666
4.04
497
nw,
288
0.201
4.1
5.41
1558
4.04
1164
all
900
0.201
4.1
5.41
4867
4.04
3636
Partitions
12C-Osw Frm wall, r-13 cav ins, 1/2" gypsum board int fnsh, 2"x4"
207
0.096
13.0
2.58
533
1.37
284
wood frm, 16" o.c. stud: 12C-Osw Frm wall, r-13 cav ins, 1/2" gypsum
board int fnsh, 2"x4" wood frm, 16" o.c. stud
Windows
2A-2om: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, cir innr,
ne
34
0.600
0
16.1
542
31.2
1049
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (6.3 ft
sw
34
0.600
0
16.1
542
24.4
819
window ht, 0.38 ft sep.); 6.67 ft head ht
sw
32
0.600
0
16.1
508
24.4
768
all
99
0.600
0
16.1
1593
26.7
2637
2A-2om: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, clr innr,
ne
33
0.600
0
16.1
525
31.2
1016
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (6.3 ft
window ht, 11.72 ft sep.); 6.67 ft head ht
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, cir innr,
ne
12
0.600
0
16.1
194
31.2
375
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 7 ft overhang (8 It
window ht, 0.19 It sep.); 6.67 ft head ht
2A-2om: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, cir innr,
ne
14
0.600
0
16.1
226
26.9
376
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 50% drapes, medium; 2
ne
32
0.600
0
16.1
523
26.9
870
it overhang (5.25 ftwindow ht, 0.38 ft sep.); 6.67 ft head ht
nw
14
0.600
0
16.1
226
26.9
376
all
60
0.600
0
16.1
974
26.9
1622
^� wri htsoft" 2016-Jul-2811:30:25
�� 9 Right -Su te® Universal 2017 17.0.03 RSU24009 Page 1
..TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE
2A-2oml: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, clr innr,
ne 28 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 50% drapes, medium;
6.33 ft overhang (5.25 ft window ht, 0.23 ft sep.); 6.67 ft head ht
i
2A-2orri: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr,
se 11 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (4.17 ft
window, ht, 0.38 ft sep.); 6.67 ft head ht
2B-2fmi 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, cir innr,
se 4 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (2 ft
window ht, 0.38 ft sep.); 6.67 ft head ht
2A-2omd: 2 glazing, clr low-e outr, air gas, mg no brk firm mat, cir innr,
sw 144 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (8 ft
window ht, 11.96 ft sep.); 6.67 ft head ht
2A-2omd: 2 glazing, cir low-e outr, air gas, mtl no brk firm mat, cir innr,
sw 72 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 14.33 ft overhang (8 ft
window ht, 0.38 ft sep.); 6.67 ft head ht
2A-2omd: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, clr innr,
sw 128 0.600
114" gap, 1/8" thk; NFRC rated (SHGC=0.32); 50% drapes, medium; 8
ft overhang (8 ft window ht, 0.38 ft sep.); 6.67 ft head ht
2A-2onj: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, cir innr,
nw 6 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (3.2 ft
window ht, 0.38 ft sep.); 6.67 ft head ht
2A-2orrl: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr,
nw 28 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (5.3 ft
window ht, 0.38 ft sep.); 6.67 ft head ht
2A 2om �2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr,
nw 14 0.600
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 50% drapes, medium;
9.33 ft overhang (5.3 ft window ht, 0.38 ft sep.); 6.67 ft head ht
Doors
11 DO: Door, wd sc type
Ceilings
16X19-Omd: Attic ceiling, mtl roof mat, r-20 roof ins, 1/2" gypsum board
int fnsti
Floors
22A-tpll: Bg floor, light dry soil, on grade depth
0 16.1
452
26.9
752
0 16.1
185
20.8
238
0 16.1
65
16.0
64
0 16.1
2324
31.4
4528
0 16.1
1162
16.0
1153
0 16.1
2066
14.1
1803
0 16.1
103
31.2
200
0 16.1
456
31.2
883
0 16.1
228
26.9
380
ne 24
0.390
0
10.5
252
11.4
273
n 21
0.390
0
10.5
224
11.4
243
all 45
0.390
0
10.5
476
11.4
516
1959
0.408
19.0
1.52
2984
1.50
2939
195
0.989
0
26.6
5174
0
0
wrightsofr Right -Suite® Universal 2017 17.0.03 RSU24009 2016-Jul-28 11:30:25
AimPage 2
...TarponFlatsModelB\Lot7TarponFlatsModeIBGLNE.rup Calc = MJ8 House faces: NE
- Component Constructions
P
Job: LOT 7TARPON FLATS M...
Date: Jan 29, 2016
wrightsoft®
Zone 1
By: RH
DEL AIR HTG, A/C & REFRIG.
INC
531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax:407-333-3853 Web: WWW.DELAIR.COM
I
Project•
•
For: PHOENIX REALTY HOMES
Design Conditions
Location:
Indoor:
Heating
Cooling -
Vero Beach Municipal AP, FL, US
Indoor temperature (T)
70
75
Elevation: 30 ft
Design TD (T)
27
16
Latitude: 28 °N
Relative humidity (%)
30
50
Outdoor: Heating Cooling
Moisture difference
(gr/lb)
-0.2
58.7
Dory bulb (T) 43 91
Infiltration:
Daily range (T) - 16 ( L )
Wet bulb 78
Method
Simplified
(T) -
Construction
quality
Semi -tight
Wind speed (mph) 15.0 7.5
Fireplaces
0
I
Clg HTM Gain
Construction descriptions Or
Area U-value
Insul R Htg HTM Loss
it- BtuhrdL F
fiz'FBtuh
BtuhM OWh
BtuhV Btuh
Walls]
13A-2ocs:13A-2ocs ne
251 0.201
4.1
5.41 1358
4.04 1015
se
426 0.201
4.1
5.41 2301
4.04 1720
j sw
268 0.201
4.1.
5.41 1447
4.04 1081
nw
435 0.201
4.1
5.41 2352
4.04 1757
all
1379 0.201
4.1
5.41 7459
4.04 5573
I
Partitions
121C-0sw Frm wall, r-13 cav ins, 1/2" gypsum board int fnsh, 2"x4"
207 0.096
13.0
2.58 533
1.37 284
wood frm, 16" o.c. stud:12C-Osw Frm wall, r-13 cav ins, 1/2" gypsum
board int fnsh, 2"x4" wood frm, 16" o.c. stud
Windows
2A-2om: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, cir innr, ne
34 0.600
0
16.1 542
31.2 1049
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 it overhang (6.3 ft sw
34 0.600
0
16.1 542
24.4 819
window ht, 0.38 ft sep.); 6.67 ft head ht sw
32 0.600
0
16.1 508
24.4 768
all
99 0.600
0
16.1 1593
26.7 2637
2A-2om: 2 glazing, cir low-e outr, air gas, mill no brk frm mat, clr innr, ne
33 0.600
0
16.1 525
31.2 1016
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 It overhang (6.3 ft
window ht, 11.72 ft sep.); 6.67 ft head ht
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, cir innr, ne
12 0.600
0
16.1 194
31.2 375
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 7 It overhang (8 ft
window ht, 0.19 it sep.); 6.67 ft head ht
-
2A-2om: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, Or innr, se
11 0.600
0
16.1 185
20.8 238
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (4.17 ft
window ht, 0.38 ft sep.); 6.67 ft head ht
2A-2omd: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, clr innr, sw
144 0.600
0
16.1 2324
31.4 4528
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (8 ft
window ht, 11.96 ft sep.); 6.67 ft head ht
2A-2omd: 2 glazing, cir low-e outr, air gas, mtl no brk frm mat, cir innr, sw
72 0.600
0
16.1 1162
16.0 1153
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 14.33 It overhang (8 ft
window ht, 0.38 ft sep.); 6.67 ft head ht
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, cir indr, nw
6 0.600
0
16.1 103
31.2 200
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (3.2 ft
window ht, 0.38 It sep.); 6.67 ft head ht
C Wrl htsoft° 2016-Jul-2811:30:25
9 Right -Suite® Universal 2017 17.0.03 RSU24009
...TarponFlatsModelBlLot7TarponFlatsModeIBGLNE.rup Calc = MJ8 House faces: NE Page 3
2A-2om:2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, nw
28
0.600
0
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (5.3 ft
windowlht, 0.38 It sep.); 6.67 ft head ht
I
Doors,
a 11 DO: Door, wd so type ne
24
0.390
0
n
21
0.390
0
all
45
0.390
0
Ceilings
16X19-Omd:Attic ceiling, mtl roof mat, r-20 roof ins, 1/2" gypsum board
1152
0.408
19.0
intfnsh
Floors
22A-tpli Bg floor, light dry soil, on grade depth
195
0.989
0
16.1 456 31.2 883
10.5
252
11.4
273
10.5
224
11.4
243
10.5
476
11.4
516
1.52
1755
1.50
1728
26.6
5174
0
0
wriPage ghtsofr Right -Suite® Universal 2017 17.0.03 RSU24009 2016-Jul-26 11:30
age4
4
...TarponFlatsModelB\Lot71'arponFlatsModeIBGLNE.rup Calc = MJB House faces: NE
P
nrrightsoit® Component Constructions
i
Zone 2
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Location:
Vero Beach Municipal AP, FL, US
FIevation: 30 ft
Latitude: 28 °N
Outdoor: Heating Cooling
Dry bulb (OF) 43 91
Daily range (09 - 16 (L )
Wet bulb (°F) - 78
• Wind speed (mph) 15.0 7.5
i
Indoor: ' Heating
Indoor temperature (OF) 70
Design TD (OF) 27
Relative humidity (%) 30
Moisture difference (gr/lb) -0.2
Infiltration:
Method Simplified
Construction quality Semi -tight
Fireplaces 0
Cooling
75
16
50
58.7
. Construction descriptions
Or
Area
U-value Insul R Htg HTM
Loss
Clg HTM Gain
ft'
BtuhRtZT fr= 'Ffi tuh
BtuhM
Btuh
BtuhN Btuh
Walls
13A-2oi s 2: 13A-2ocs 2
ne
177
0.201 4.1
5.41
956
4.04 714
se
312
0.201 4.1
5.41
1688
4.04 1261
sw
123
0.201 4.1
5.41
666
4.04 497
nw
288
0.201 4.1
5.41
1558
4.04 1164
all
900
0.201 4.1
5.41
4867
4.04 3636
Partitions
(none)
Windows
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr,
ne
14
0.600 0
16.1
226
26.9 376
1/4" gap, 118" thk; NFRC rated (SHGC=0.32); 50% drapes, medium; 2
ft overhang (5.25 ft window ht, 0.38 it sep.); 6.67 ft head ht
ne
32
0.600 0
16.1
523
26.9 870
nw
14
0.600 0
16.1
226
26.9 376
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr,
all
ne
60
28
0.600 0
0.600 0
16.1
16.1
974
452
26.9 1622
26.9 752
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 50% drapes, medium;
6.33 ft overhang (5.25 ft window ht, 0.23 ft sep.); 6.67 ft head ht
2B-2fm:2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr,
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 2 ft overhang (2 ft
se
4
0.600 0
16.1
65
16.0 64
window ht, 0.38 ft sep.); 6.67 it head ht
2A-2omd: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr,
sw
128
0.600 0
16.1
2066
14.1 1803
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 50% drapes, medium; 8
ft overhang (8 it window ht, 0.38 ft sep.); 6.67 ft head ht
2A-2om 2 glazing, clr low-e outr, air gas, mil no brk frm mat, clr innr,
nw
14
0.600 0
16.1
228
26.9 380
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32); 50% drapes, medium;
9.33 ft overhang (5.3 ft window ht, 0.38 ft sep.); 6.67 it head ht
Doors
(none)
i9CC.A wrightsoft' Right -Suite® Universal 2017 17.0.03 RSU24009 2016Jul-28 11:30:25
Page 5
...TarpanFlatsModelB\Lat7TarpanFlatsModeIBGLNE.rup Calc = MJ8 House faces: NE 9
Ceilings
16M �Omd: Attic ceiling, mtl roof mat, r-20 roof ins, 1/2" gypsum board 807 0.408 19.0 1.52 1229 1.50 1211
intfnsh
Floors
(none)
8
^t Wrl htso't° 2016-Jul-2811:30:25
z69 Right -Suite® Universal 2017 17.0.03 RSU24009 K...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE Page 6
-;wrightsoft® Project Summary
Entire, House
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Notes:
Winter Design Conditions
Outside db 43 IF
Inside db 70 OF
Design TD 27 °F
Heating Summary
Structure 35369 Btuh
1Ducts ' 5087 Btuh
Central vent (58 cfm) 1714 Btuh
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 42170 Btuh
Infiltration
Method Simplified
'Construction quality Semi -tight
Fireplaces 0
Heating Cooling
Area (ft2)
2669
2669
Volume (ft3)
25724
25724
Air changes/hour
0.28
0.15
IEquiv. AVF (cfm)
120
64
Heating Equipment Summary
Make n/a
Trade n/a
Model n/a
AHRI ref. n/a
Efficiency
n/a
Heating input
Heating output
0 Btuh
Temperature rise
0 OF
Actual air flow
0 cfm
Air flow factor
0 cfm/Btuh
Static pressure
0 in H2O
Space thermostat
n/a
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Summer Design Conditions
Outside db
91
OF
Inside db
75
°F
Design TD
16
°F
Daily range
L
Relative humidity
50
%
Moisture difference
59
gr/lb
Sensible Cooling Equipment Load Sizing
Structure
38324
Btuh
Ducts
3564
Btuh
Central vent (58 cfm)
988
Btuh
Blower
0
Btuh
Use manufacturer's data
y
Rate/swing multiplier
Equipment load
1.00
42875
Btuh
sensible
Latent Cooling Equipment Load Sizing
Structure
3564
Btuh
Ducts
3193
Btuh
Central vent (58 cfm)
2313
Btuh
Equipment latent load
6757
Btuh
Equipment total. load
49632
Btuh
Req. total capacity at 0.70 SHR
5.1
ton
Cooling Equipment Summary
Make n/a
Trade n/a
Cond n/a
Coil n/a
AHRI ref. n/a
Efficiency
n/a
Sensible cooling
0
Btuh
Latent cooling
0
Btuh
Total cooling
0
Btuh
Actual air flow
0
cfm
Air flow factor
0
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
�. wri ht"ft® 2016-Jul-2811:30:25
.►— � g Right -Suite® Universal 2017 17.0.03 RSU24009
��...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE Page 1
wrightsoft Project Summary
Zone 1
DEL AIR HTG, A/C & REFRIG. INC
ISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Notes:
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Weather: Vero Beach Municipal AP, FL, US
Winter Design Conditions
Summer Design Conditions
•I Outside db
43 OF
Outside db
91
°F
Inside db
70 °F
Inside db
75
°F
Design TD
27 °F
Design TD
16
OF
Daily range
L
'
Relative humidity
50
%
_.
Moisture difference
59
gr/lb
Heating
Summary
Sensible Cooling Equipment Load Sizing
Structure
24120 Btuh
Structure
26444
Btuh
Ducts
3792 Btuh
Ducts
2664
Btuh
Central vent (58 cfm)
1714 Btuh
Central vent (58 cfm)
988
Btuh
Humidification
0 Btuh
Blower
0
Btuh
Piping
0 Btuh
Equipment load
29627 Btuh
Use manufacturer's data
y
Infiltration
Rate/swing multiplier
Equipment load
1.00
sensible
30095
Btuh
Method
Construction quality
Simplified
Semi -tight
Latent Cooling Equipment
Load Sizing
Fireplaces
0
Structure
2576
Btuh
Ducts
2565
Btuh
Area (
Heating Cooling
1959 1959
Central vent (58 cfm)
Equipment latent load
2313
7454
Btuh
Btuh
Volume
e �ft3)
18219 18219
Air changes/hour
Equiv. AVF
0.24 0.13
Equipment total load
37549
Btuh
(cfm)
74 40
Req. total capacity at 0.75 SHR
3.3
ton
Heating Equipment Summary'
Intake Carrier
Trade CARRIER AIR CONDITIONING
Model CH14NB042****A
AHRI ref 7835544
Efficiency
8.2 HSPF
Heating input
Heating output
41000 Btuh @ 47°F
(Temperature rise
28 OF
Actual air flow
1333 cfm
Air flow factor
0.048 cfm/Btuh
Static pressure
0.40 in H2O
Space thermostat
Cooling Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Cond CH14NB042****A
Coil FB4CNP042L
AHRI ref 7835544
Efficiency
11.5 EER, 14 SEER
Sensible cooling
30000
Btuh
Latent cooling
10000
Btuh
Total cooling
40000
Btuh
Actual air flow
1333
cfm
Air flow factor
0.046
cfm/Btuh
Static pressure
0.40
in H2O
Load sensible heat ratio
0.80
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft• Right -Suite® Universal 2017 17.0.03 RSU24009 2016-Jul-28 11:30:25
...TarpanFlatsModel81Lot7TarponFlatsModeIBGLNE.rup Cale = MJ8 House faces: NE
Page 2
-�- wrightsoft- Project Summary
Zone 2
DEL AIR HTG, A/C & REFRIG. INC
531 COpISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax:407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Notes:
Weather:
Winter Design Conditions
Outside db 43 °F
Inside db 70 °F
Design TD 27 OF
Heating Summary
_ Structure
11249
Btuh
Ducts
1294
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
12543
Btuh
Infiltration
,Method
'Construction quality
Fireplaces
Heating
Area (ft2 710
Volume ()ft3) 7505
Air changes/hour 0.37
Equiv. AVF (cfm) 46
Vero Beach Municipal AP, FL, US
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Summer Design Conditions
Outside db
91
°F
Inside db
75
OF
Design TD
16
°F
Daily range
L
Relative humidity
50
%
Moisture difference
59
gr/lb
Sensible Cooling Equipment Load Sizing
Structure 11880 Btuh
Ducts . 900 Btuh
Central vent (0 cfm) 0 Btuh
Blower 0 Btuh
Use manufacturer's data y
Rate/swing multiplier 1.00
Equipment sensible load 12781 Btuh
Simplified
Latent Cooling Equipment Load Sizing
Seml-tight
0
Structure
988
Btuh
Ducts
628
Btuh
Cooling
Central vent (0 cfm)
0
Btuh
710
Equipment latent load
1616
Btuh
7505
0.20
Equipment total load
14397
Btuh
25
Req. total capacity at 0.75 SHR
1.4
ton
Heating Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Model CH14NB018****A
AHRI ref 7845770
Efficiency
8.2 HSPF
Heating input
Heating output
17600 Btuh @ 47°F
Temperature rise
27 OF
Actual air flow
593 cfm
Air flow factor
0.047 cfm/Btuh
Static pressure
0.30 in H2O
Space thermostat
Cooling Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Cond CH14NB018****A
Coil FB4CNP018L
AHRI ref 7845770
Efficiency
11.7 EER, 14 SEER
Sensible cooling
13350
Btuh
Latent cooling
4450
Btuh
Total cooling
17800
Btuh
Actual air flow,
593
cfm
Air flow factor
0.046
cfm/Btuh
Static pressure
0.30
in H2O -
Load sensible heat ratio
0.89
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
Wrl htSOft' 2016-Jul-28 11:Page e 3
A 9 Right -Suite® Universal 2017 17.0.03 RSU24009
...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE
- wrightsofi' Right-J® Worksheet
Entire House
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
Job: LOT 7 TARPON FLATS MOD...
Date: Jan 29, 2016
By: RH
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
. P. -Pid- wrightsoft, Right-Sulte® Universal 2017 17.0.03 RSU24009 2016-Jul-28 11:30:25
...TarponFlatsModelB\Lot7TarponFlatsModeIBGLNE.rup Cale = MJ8 House faces: NE
Page 1
-�- Wrightsoft° Right-J® Worksheet
Job: LOT 7TARPON FLATS MOD...
Entire House
Date: Jan 29, 2016
�
By: RH
DEL AIR HTG, A/C & REFRIG. INC
531 COLISCO
WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
1
Boom name
Zone 2
2
Exposed wall
122.0 ft
3
Room height _
9.3 It
d
4
Room dimensions
5
Room area
807.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ftz)
Load
Area
Load
number
(BtuWft2-19
(Btuh/ftz)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
s
, 13R2aCs,
t%201
ne=.
54i
�ii4
2A 20m
(614
0
'cA'Zgt
O 600
ne
1614
3 22`k
Q
b
�s
0
re�
\
z
�fl
R81048
1j 39
A,.•...e..., u. Yb
134-2oos 2
0.201
ne
5.41
4.04
251
177
956
714
2A-2om
0.600
ne
16.14
26.86
14
0
226
376
2A-2om
0.600
ne
16.14
26.86
32
0
523
870
(�
2A 2om
13A20CS�a�s
0 600
f}201
ne
8$,a.
16.14
26.86
28
t):„()
0
452
0
752
%<•..,.."€A,
2A 2om ., _
fl.6(t
._se
16.14.
20.77
" : , 0'
�._
Vdli
13A-2ocs 2
0.201
se
5.41
4.04
316
312
1688
1261
28 2fm
i3A 2ocs;"
2A 2om
0.600
0201
f).600
se
sw
sw
16.14
541,d
i6 44
16.01
239
4
�0
q
8
ID
65
tf
D
64
0
D
2A 2om
ii600
sv i
16 i4
24
2A 2omd
i 500
l A4
:
Q
n0
:
sw .
= 31
-
0
A
0
�—C
13A 2ocs 2
2A 2omd
0.201
sw
5.41
4.04
251
123
666
497
1
3Xl't3
1Cs
32A h
0.600
02<t1
6�00y
sw
nw
rnv
16.14
14.09
128
256
F
2066
1803
Q
r '
22r�om
inVtfJ.,.
A0
4
V)I
IL'—�G
13A-2ocs 2
2A-2om
0.201
0.600
nw
nw
5.41
16.14
4.04
26.86
316
14
288
0
1558
226
1164
376
2om
0.600
nw
16.14
26.86
14
0
228
380
%2A
12GOswmlWalt r
008658
'. 137
,0
0
17
" 0'
11p0
61
c) AED excursion
1990
Envelope loss/gain
9881
11458
12
a) Infiltration
b) Room
1368
422
ventilation
0
0
13
Internal gains: Occupants @ 230
0
0
Appliances/other
0
Subtotal (lines 6 to 13)
11249
118M
Less external load I1
0
0
Less transfer
0
0
Redistribution
0
0
14
15
Subtotal
Duct loads
11249
11880
12°/,
81/6
1294
900
Total room load
Air required (cfm)
12543
593
12781
593
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
AM-''
wrightsoft'
Right-Sulte®Unlversal 2017 17.0.03 RSU24009
2016-Jul-28 11:30:25
...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE
Page 2
wrightsoft Right-M Worksheet Job: LOT 7 TARPON FLATS MOD...
Zone 1 Date: Jan 29, 2016
By: RH
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO
WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
1
i
Room name
Zone 1
Bdrm PJDen
2
Exposed wall
194.5 ft.
31.5 ft
3
Room height
9.3 ft d
9.3 ft heat/cool
4
Room dimensions
1.0 x 198.0 ft
5
Room area
1959.0 ftz
19B.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ftq
Load
Area (ftq
Load
number
(Btuh/ftz°F)
(Btuh/ft9
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
.....
2A 2om
0
ne'
t614
3122
'
34
`
7 251
0
77,71a
542
1015
1049
` " i39
34
'
" " 115
0
623
642
46$
itl4s.
2A 2om g
0
ne
161d
3122
33
0
525
14 1016
0
tl
0
0'.
9.
DD m=' 1 # �
0390
an;49
4122
2a
a
�: ': 2i3.
n
11
11
.,.,
,na.'
,
1159
,."
. , ...°'
-?
.. ,•';..,n
.n
. .a :
t e .:`n'
13A-20cs 2
2A-2om
2A-2om
0.201
0.600
0.600
ne
ne
no
0.00
0.00
0.00
0.00
0.00
0.00
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2A 2om
13A 2oc a
13A-20cs 2
2B-2fm
0 600
� 02bi
0.201
0.600
ne
se,•'
se
se
0 00
S fI
0.00
0.00
0 00
4.04
20.7I
0.00
0.00
0
,
:�1
0
0
0
4'
LL16
0
0
0
Y 2 01
_, -185
0
0
0
f 17'20
3
,...._.238
0
0
0
��� 33
0
0
0
33
0
0
0
1't6
0
0
0
13�
�b
0
0
l?/
�--G
a l
y/
13A-20cs 2
2A 2omd
13A 2ocs
2A 2om ° g� �x
2�t2ortt° . a
13A-2ocs 2
2A-2om
0.201
0.600
j p 201
0 600
Q600
0.201
0.600
sw
sw
nw;77764f
ttw `
nw
nw
0 00
0.00
36 t4
m. ;16.14''.
0.00
0.00
0.00
0.00
= 404
31 ?2
0.00
0.00
0
0
' 470
6
0
0
0
0
A35
0
0
0
0
0
232
103
0
0
0
0
157
200'
0
0
0
0
112
rf s 0
0
0
0
0
112
tl
0
0
0
0
Gt73
0
0
0
--(G
'ry
2A 2om
12C Osw Frm wall, r
16X1R-0mrt
0.600
. 0{�6
0,390
n dnR
nw
.. tt`.-.21
-
0 00
258�I
1 F9
0.00
37�
1 Fn
0
228
116
0
207
a
11F9
0
53
.,_...,..224�0
179,E
0
� W,09&#
179a
0
=0
ion
0
...,.. 0
1oA
0
,...,,:.....0
9r»
61
c) AED excursion
1
2861
-78
Envelope loss/gain
21940
21990
3084
2316
12
a) Infiltration
2181
673
353
109
b) Room ventilation
0
,
0
0
0
13
Internal gains: Occupants @ 230
5
1150
0
0
Appliances/other
2630
0
Subtotal (lines 6 to 13)
24120
26WI
3437
2425
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
24120
26444
3437
2425
15
Duct loads
106
10%
3792
2664
21%
139/6
708
320
Total room load
27912
29107
4144
2745
Air required (cfm)
1333
1333
198
126
I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wrightsc ft- 2016-Jul-28 11:30:25
Right -Suite® Universal 2017 17.0.03 RSU24009 Page 3
...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE
l
- ' rightsoft°
Right-J® Worksheet
Zone 1
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
Job: LOT 7 TARPON FLATS MOD...
Date: Jan 29, 2016
By: RH
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
'pk' Wrighttsofft^ Right -Suite® Universal 2017 17.0.03 RSU24009 2016-Jul-28 11:Page 4age 4
...TarponFlatsModelBlLot7TarponFlatsModeIBGLNE.rup Cale = MJ8 House faces: NE
I
- wrightsofr Right-J® Worksheet Job: LOT 7TARPON FLATS MOD...
Zone 1 Date: Jan 29, 2016
—• - •— -- - — - ---- — — By: RH
2 1 0.2011 sw 1 0.001 0.001 01 01 01 01 01 01 01 0
2A 20 �S 2 I 0:660001 w I o:00001 0.00001 01 0 0 0 0 0 0
61
6) AED excursion
1-501
1
752
Envelope loss/gain
2246
1506
4420
4081
12
a) Infiltration
202
62
488
151
li) Room ventilation
0
0
0
0
13
l6mal gains: Occupants @ 230
0
0
1
230
Appliances/other
1200
6p0
Subtotal (lines 6 to 13)
2447
2768
4907
5062
Mess external load
0
0
0
0
Less transfer
0
0
0
0
14
Redistribution
Subtotal
0
2447
0
2768
0
4907
0
5062
15
Duct loads
21%
13%
503
365
21%
13%
1008
667
Total room load
Air required (cfm)
41
�141
31
5283
2662
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
Wrightsoft^ 2016-Jul-2811:30:25
Right -Suite® Universal 2017 17.0.03 RSU24009 Page 6
...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE
-r�-
inrrightsoft° Right-J® Worksheet Job: LOT 7 TARPON FLATS MOD...
Zone 1 Date: Jan 29, 2016
By: RH
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO
WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax 407-333-3853 Web: WWW.DELAIR.COM
1
Room name
Mstr Bthrrn
Mstr W IC
2
Exposed wall
13.0 ft
0 ft
3
Room height
9.3 ft heat/coal
9.3 ft heaUcool
'
4
5
I Room dimensions
Room area
1.0 x 125.0 ft
125.0 ftz
8.0 x 10.0 ft
80.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ftq
Load
Area (ftq
Load
number
(BtuWft2-'9
(Btuh/ft�)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
8
13A 2oCs
2A 2om
2A2omfb
2A 2om
77- 201
O 600
Q6�
O6�
ne
ne=
ne'
net=
S 4t
w 1614
1814
1614
_ t0..
4 44
3122
3122a
31 22
�1�39'
D
0
0
`a Q
0
0
9
0
;0)
- 9
%7-0
0
rr�g0
0
m0
- 0
0
0
0
0
0
0
3 0
0
0
__0
0
0
•� ,. , ..4
= 0
0.
0_
...,_ $ 0.
yy11
I--G
13A-2ocs 2
2A-2om
2A-2om
0.201
0.600
0.600
no
ne
ne
0.00
0.00
0.00
0.00
0.00
0.00
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
.
V►/
�C
2A 2om
13A2ocs�'�4:0'L01
13A-2ocs 2
2B-2fm
0.600
0.201
0.600
ne
se'
_.se.w
se
se
0.00
541
2:16:14
0.00
0.00
0.00
'k04
:717,
0.00
0.00
0
77 �Q
_ 0
0
0
0
4
........0
0
0
0
0
0
0
0
d
0
0
0
0
0
0
0
0
0
0
0
77,77, �0
0
0
0
mm 0
0
2A 2om
2A 2omd"
0 600
0600
svv
sw
t i614
1614
24 39
31 44
fr 0
0
0
0
�0
0
0
D
0
0
0
r 0
0
0
0
_ .0,�
2L
_.
2A 2omd
0,600
sw'
_ iS 14
a16.01
:°_�r.:....,� m0
D
u 0
0
r 0
_0
. _ 0
: 0
VI/
13A-20cs 2
0.201
sw
0.00
0.00
0
0
0
0
0
0
0
0
_G
2A 2omd
0.600
sw
0.00
0.00
0
0
0
0
0
0
0
0
f3AZoos �
2A 2om
� 0"20t
rnu,
�4f��"`404�
1614
12�
93
501
374
0
� 0
� 0
4 6�
nw.
) 3122
; 0
0
'
.2A.2om... _._.
O.6Q0
_rnv.
1614
31,22:
26
.._� w.ttl
•tea°456
.., a
�a U
0
V�I
13A-20cs 2
2A-2om
0.201
0.600
nw
nw
0.00
0.00
0.00
0.00
0
0
0
0
0
0
0
0
0
0
.0
0
0
0
0
0
0
0.600
nw
0.00
0.00
0
0
0
0
0
0
0
0
F�rtt1
Q
0
12A-20m
. a.Q 3 �0
;
....m 10 8'1.33
e�°8
A
,yam
hi�0
�0{
yQ
(�
1RY1 U-n-M
nena
-
1 ro
i rn
for
tor;
ion
12a
cn
cn
79
7c
61
c) AED excursion
1279
-2
Envelope loss/gain
1493
1724
76
73
12
a) Infiltration
146
45
0
0
b) Room ventilation
0
0
0
0
13
Intemal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1
1639
17691
176
73
Less external load
0
0
0
0
Less transfer
0
0
0
0
bedistribution
0
0
0
0
14
Subtotal
1639
1769
76
73
15
duct loads
21%
139/6
337
233
21%,
131%
16
10
Total room load
1976
2002
92
82
Air required (cfm)
94
92
4
4
Calculations approved by ACCA to meet all requirements
of Manual J 8th Ed.
- wrightsoft` Right -Suite® Universal 2017 17.0.03 RSU24009
2016 Jul-28 11P.age 7
...TarponFlatsModelB\Lot7TarponFlatsModeIBGLNE.rup cola = MJ8 House faces: NE
I
g
- wrightsoft®
Right-J® Worksheet Job: LOT 7 TARPON FLATS MOD...
'
Zone Date: Jan 29, 2016
By: RH
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO
WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
1
Room name
Mstr WC
Utility
2
Exposed wall
0 ft
0 ft
3
Room height
9.3 It heat/cool
9.3 ft heat/cool
4
Room dimensions
6.0 x 3.0 ft
8.0 x 5.0 ft
5
Room area
18.0 ft2
40.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/ft2-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
#�712ocs
2A tom
2A tom
w, t p 201
t) 6p0
ne
41
#
az,.W„'•'
3122
• 04
pfl
0'
0
p
fl
�
�R2
p
�
0
0
0
D0
fl
A'
D
fl
n
2
'_11Dfl__.W
2A 2om
506p0
0,390
he
.,,ria.
1&f',
tU49
31
#t.33
r �0
. O
;x p
0
.0
._ := E0
p
, .,,,., 0
;p
..•-. ,. .'0
61
c) AED excursion
-1
-24
Envelope loss/gain
27
26
253
139
12
a) Infiltration
0
0
0
0
b) Room ventilation
0
0
0
0
13
Intemal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
600
Subtotal (lines 6 to 13)
271
26
253
739
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
15
Subtotal
Duct loads
21%
13%
27
6
26
3
220/c
14%
253
55
739
103
Tptal room load
33
30
308
841
Air required (cfm)
2
1
15
39
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
�. wr1gh2:sc fv 2016-Jul-28 11:30:25
Right -Suite® Universal 2017 17.0.03 RSU24009 Page 8
'
...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE
-�}+- rightsoft' Right-J®Worksheet
Job: LOT 7 TARPON FLATS MOD...
Zone 2 Date: Jan 29, 2016
By: RH
DEL AIR HTG, A/C & REFRIG. INC
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax 407-333-3853 Web: WWW.DELAIR.COM
1 Room name Zone 2 Bdrm 3
2 Exposed wall 122.0 ft 11.5 ft
3 Room height 9.3 ft d 9.3 ft heabcool
4 Room dimensions 11.5 x 13.0 ft
5 iRoom area 807.0 ftz 149.5 ft2
!Ty Construction U-value Or HTM Area (ft9 Load Area (ftq Load
number (BtUWft2-'9 (Btuh/ftor perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 �'�712a s 0 201 neo; 0 OU � 0 00 77" 0
2A 2om ` 3 0 6DO ne 0 00 ADO 0 0 0 0 0 0 1 0 0
2A 2om 0 600 ne 0 000 00 . 0 0 '0 0 0 0 y 0 0
2A2om 0600 ne, OOb 0OD'"� 0 0 0
1 t _11QQ s10390 •ne 0.00 . __..DOD: 0
13A-2ocs 2 0.201 ne 5.41 4.04 251 177 956 714 0 0 0 0
2A-2om 0.600 ne 16.14 26.86 14 0 226 376 0 0 0 0
2A-2om 0.600 ne 16.14 26.86 32 0 523 870 0 0 0 0
2A 2om 0.600 ne 1614 26.86 28 0 452 752 0 0 0 0
iAocs 1f)1 se0 00' O Oti ' 0 0 70 d
13A-2ocs 2 0.201 se 5.41 4.04 316 312 1688 1261 0 .•s........0 0 0
28-2fm 0.600 se 16.14 16.01 4 8 65 64 0 0 0 0
13A 266s U 201 sw, O OR:0 00 ' 0 U ' "0 r0 0 0 0 - 0
2A2om �ofiDO sw 000 000 0 00E 0 0 0 0 0
2A 2om ' 0 600 sw 0 00 0 00 0 0 0 0
47'ZA 2omd_ F $ 0600 sw 0 0 00 0
?A.2omd s 0f isww .00' ....,..D.DOx i1. ..«:.n.:%0 ,..>M.Q 0 ax._0x&-2-Q,, Q
13A-20cs 2 0.201 sw 5.41 4.04 251 123 666 497 107 43 232 174
2A 2omd 0.600 sw 16.14 14.09 128 256 2066 1803 64 64 1033 902
�3�12ocs' 0 2D1 nw 0 00 D 00 �'1 0 0 0 0 0 0 0 Q
2A 2om 600 rnv 0 00 0 00 ; 0 0 0 0# 0 0 0 0
-�h�!M .........UG ._.., o,00 Q L MQ � 0 � � 0 .0 Q 0.... � a0
1al 13A-2ocs 2 0.201 nw 5.41 4.04 316 288 1558 1164 0 0 0 0
I�---GG 2A-2om 0.600 nw 16.14 26.86 14 0 226 376 0 0 0 0
2A 2om 0.600 nw 1614 26.86 14 0 228 380 0 0 0 0
f� 12C Osw Fmt wall, r; tT 0)6 �00 p 0 " µ0 0 ��0 0 n, 0
-0 11116%�.Q _ 'Q
f: 1AY1Q-nmri a nAm 1 r9 1 rn Hr17 An7 1VIM 1011 15n 1sn �n 7JR � Md
61
Ic) AED excursion
119901
1
990
Envelope loss/gain
9881
11458
1493
2289
12
a) Infiltration
1368
422
129
40
;b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
11249
118801
1
1622
2329
'Less external load
0
0
0
0
Less transfer
0
0
0
0
IRediistribution
0
0
0
0
14
;Subtotal
11249
118BO
1622
2329
15
'Duct loads
121%
8%
1294
900
121%
8%
187
176
(Total room load
12543
12781
1808
2506
(Air required (cfm)
593
593
86
116
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
"*- wriightSoft' 2016-Jul-28 11:30:25
Right -Suite® Universal 2017 17.0.03 RSU24009 Page 9
'
...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Colo = MJ8 House faces: NE
wrightsoft° Right-J® Worksheet Job: LOT 7 TARPON FLATS MOD...
' Zone 2 Date: Jan 29, 2016
DEL AIR HTG, A/C & REFRIG. INC By: RH
j 531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax:407-333-3853 Web: WWW.DELAIR.COM
1 Room name Bdrm 3 WIC Bdrm 4
2 Exposed wall 11.0 ft 31.0 ft
3 Room height 9.3 ft heat/cool 9.3 ft heat/cool
4 Room dimensions 5.5 x 5.5 ft 1.0 x 214.0 ft
5 1Room area 30.3 ft2 214.0 ft2
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/ft2-°n (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat C001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool
s f�"Y3A2ocs �" U201 ne' O:bb 000r 40»"''`.0 r0�bk p 0b 0
2A tom 0 60D ne 0 00 .0.00 0 0 A° 0 0 0 0 0 0
2A tom 0 6w ne 000 , 00 U 0 0 0 0 0 0 0
2A tom x 0 6Q0 0e 0.00 0 00 0 0 0 0 0 0 Q, 0
11 `` 1IJ�Q� _b390na� Q.Oq' �00�_ _0 20. _.0
13A-2ocs 2 0.201 no 5.41 4.04 0 0 0 0 121 89 479 358
2A-2om 0.600 ne 16.14 26.86 0 0 0 0 0 0 0 0
2A-2om 0.600 ne 16.14 26.86 0 0 0 0 32 0 523 870
2A 2om 0 600 no 1614 26.86 0 0 0 0 0 0 0 0
13A 2ocs Q i 2Qf se. Q 00 01,00 0 0 )0 - p "0 0 0 d
O.OQ _._O.00 m_. D:U :.,��...>__:��.0 0 _r__0 _...__0
I 13A 2ocs 2 0.201 se 5.41 4.04 51 51 277 207 121 121 654 488
L'--G 2B 2fm 0.600 se 16.14 16.01 0 0 0 0 0 0 0 0
13A 2o0s t3 201 'svr ' 0-W 0 to 0 0 0 0 0 0 0 0
2A2om m� 06�'•sw, 000 000 .'b 0 0 0 0 0 ' 0 0.
2A zom' 0 600 sw 0.00 0.06 1 0 0 0 0 0 0, 0 0
2A 2omd°` Q 0 600 sw 0 00 3 0 00 0 'O,QO;.0,00
13A 2ocs 2 0.201 sw 5.41 4.04 51 51 277 207 0 0 0 0
t_G 2A 2omd _ 0.600 sw 16.14 14.09 0 0 0 0 0 0 0 0
1 n 13A 2ocs 020vr'. 0 O+} 0 QO A. 0'7 � =Q 0' = 0 � 0 77777,776 � 0.
2A 2om 0 600 rnnr 0 00 0 00 0 a�" 0 0 0
2A.2om - Q 60p _&w .�..._ U L 0,00 f .=,..� :.:0 Ilk � Q _ �..-"0 _- �._ .: •-__Q � � A .p � �._0, 0,
y! 13A-2ocs 2 0.201 nw 5.41 4 04 0 0 0 0 47 32 175 131
I�---GG 2A 2om 0.600 nw 16.14 26.86 0 0 0 0 0 0 0 0
2A 2om 0.600 nw 16.14 26.86 0 0 0 0 14 0 228 380
i20-Mw'Frm Wall rE U 096 0 00 0 00 = 0 0 =0 : 0 1 0 0 _ 0 Q
b.390 . h- L.,,.,O.00 a -. ,0.00 LLno .0 ..::0 .. O :� ;M �.�.:...0 0 �..._.. _0 0 � Q
r 1RX1CWrnr1 nAnR - iFig _ 15r1 AnI _qnARI dr. VIM 91d Q=1 QVI
6
c) AED excursion
-1
-4
Envelope loss/gain
599
458
2384
2543
12
a) Infiltration
123
38
348
107
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
723
4961
1
2731
2650
Less external load
0
0
0
0
Less transfer
0
0
0
0
(Redistribution
0
0
0
0
14
Subtotal
723
496
2731
2650
15
'Duct loads
12%,
8%
83
38
129/6
80/6
3141
201
Total room load
806
534
3046
2851
Air required (cfm)
38
25
144
132
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsaf - 2016-Jul-28 11:Pa30:25
Right-Sulte® Universal 2017 17.0.03 RSU24009
9
...TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Colo = MJ8 House faces: NE
-�- wrightsoft Right-J® Worksheet Job: LOT 7TARPON FLATS MOD...
Zone 2 Date: Jan 29, 2016
- DEL AIR HTG, A/C & REFRIG. INC By: RH
i 531 C )DISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
1 ! Room name Lounge Shared Bthrm
2 'Exposed wall 55.0 ft 13.5 ft
3 Room height 9.3 ft heat/cool 9.3 ft heat/cool
4 Room dimensions 1.0 x 339.0 ft 5.5 x 13.5 It
5 Room area 339.0 ft2 74.3 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2-IF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat C001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 2A 2o2m �-U 600 ne, 000 ' 0 DO 0 R 0 .�.,...,,.,.a,.a.. 0 0 U 0 0�w0
Aga . 2A 2om,. 0 60tl ne b Q 0' 0 0 0 0
2Atom m R$00 he�,�9.........._.�;0
13A-2ocs 2 0.201 ne 5.41 4.04 130 88 477 356 0 0 0 0
2A-2om 0.600 ne 16.14 26.86 14 0 226 376 0 0 0 0
2A 2om 0.600 no 1614 26.86 0 0 0 0 0 0 0 0
2A 2om 0.600 ne 16.14 26.86 28 0 452 752 0 0 0 0
13A 2ocs 3 t):2D1 se. O Of r D 00 o o �9 m :D D o o D4'
_LD �.rzo La.0
V1J 13A-2ocs 2 0.201 se 5.41 4.D4 19 19 101 75 126 122 657 491
_G 28 2fm 0 600 se 16.14 16 01 0 0 0 0 4 4 65 64
13A 2ocs 0.201 sw. 8 00w 0 00 0 (i
2A2om �' 0600 sw 0.00; 000 0 �0 0 0 0 0 D 0
t 2A Zom 0 600 sw: 0 00 k 0 00 . q f] 0 0 0 D 0 0 2 0
2A 2omd �' 7 0 600 Sw;. 0.001
x 001
4 0
_ 2A 2om�lsa �_ O:F Sw.; ' 0 00 0 vo - 0 b _ k.�0 0 ............ti ,o
VN 13A 2ocs 2 0.201 sw 5.41 4.04 93 29 157p 117 0 0 0 0
�C 2A 2omd 0.600 sw 1614 14.09 64 64 1033 902 0 0 0 0
13A 2ocs°_ 0 2Ui my D 00 oro0 0 0 0 0 0 0 D 0
2A2om 0:6UD rnv° 000= 0W 00 �0 0 D 0 0
2A-2omx.>r:< 0? itw �0 Q0.- _D.i10 0
V)/ 13A 2ocs 2 0.201 nw 5.41 4.04 270 256 1383 1033 0 0 0 0
f�-CG 2A 2om 0.600 nw 1614 26.86 14 0 226 376 0 0 0 0
2A 2om 0.600 nw 16.14 26.86 0 0 0 0 0 0 0 0
12Gosvlr..", .rtn wail, r �° O'096 0 00 0 00 �� ."....., ,U ._.,� ° to '»�„�'.,..".,, 0
0 l P 0 D 0 .". .." 0,
10, ram_. 0 � D 0 _. 0 µ `0 _0
� � a 0
C 16X19-0md n_4nA - 1 F9 1 �,r1 aao aao ,.�=1- -
71
6
c) AED excursion
1006
1
Envelope loss/gain
4570
5502
835
665
12
a) Infiltration
617
190
151
47
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
5187
5693
986
712
Less external load
0
0
0
0
Less transfer
0
0
Redistribution
0
0
0
0
14
Subtotal
5187
5693
986
712
15
Duct loads
12%
8%
597
431
12%
8%
113
54
Total room load
Air required (cfm)
5783
6124
1100
766
274
284
52
36
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrilghtsofC
Right -Suite® Universal 2017 17.0.03 RSU24009 2016-Jul-28 11:30:25
..TarponFlatsModelBNLot7TarponFlatsModelBGLNE.rup Colo = MJ8 House faces: NE Page 11
r
I
-�- wrightsoft® Duct System Summary
Zone 1
DEL AIR HTG, A/C & REFRIG. INC
i
531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax:407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Heating Cooling
External static pressure 0.40 in H2O 0.40 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.40 in H2O 0.40 in H2O
Supply / return available pressure 0.200 / 0.200 in H2O 0.200 / 0.200 in H2O
Lowest friction rate 0.327 in/100ft 0.327 in/100ft
Actual air flow 1333 cfm 1333 cfm
Total effective length (TEL) 122 ft
SupplyDetail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat[
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bdrmj2/Den
h 4144
198
126
0.498
8.0
Ox0
VIFx
10.3
70.0
Breakfast
h 3783
181
150
0.339
7.0
Ox0
VIFx
33.1
85.0
stl
Bthrni 2
h 830
40
30
0.506
4.0
Ox 0
VIFx
9.0
70.0
Dining
h 1784
85
82
0.436
6.0
Ox0
VIFx
21.8
70.0
Great
c 4412
146
202
0.454
8.0
Ox0
VIFx
18.2
70.0
Great A
c 4412
146
202
0.493
8.0
Ox 0
VIFx
11.2
70.0
Kitchen
c 3133
141
144
0.334
7.0
Ox 0
VIFx
34.6
85.0
stl
Mstr Bdrm
h 5915
283
262
6.454
9.0
Ox 0
VIFx
18.2
70.0
Mstr Bthrm
h 1976
94
92
0.488
6.0
Ox 0
VIFx
11.9
70.0
Mstr we
h 33
2
1
0.502
4.0
Ox 0
VIFx
9.7
70.0
Mstr WIC
h 92
4
4
0.532
4.0
Ox0
VIFx
5.2
70.0
utility,
c 841
15
39
0.327
4.0
Ox0
VIFx
37.3
85.0
stl
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
stl
Peak AVF
336
333
0.327
617
10.0
0 x 0
V[nlFlx
Ri
wri Right -Suite® Universal 2017 17.0.03 RSU24009 htsoftm 2016-Jul-2811:30:27
C
�A 9
..TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Calc = MJ8 House faces: NE Page 1
Na
a
Grill
I Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb2
Ox 0
1333
1333
0
0
0
0
Ox 0
VIFx
��
v wril 9htoist® � Right -Suite® Universal 2017 17.0.03 RSU24009 2018-Jul-2811:30:27 ..TarponFlatsModelB\Lot7TarponFlatsModelBGLNE.rup Cale = MJ8 House faces: NE Page 2
iH
N EI
531 CO
wrightsoft® Duct System Summary
Zone 2
DEL AIR HTG, A/C & REFRIG. INC
ASCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax: 407-333-3853 Web: WWW.DELAIR.COM
For: PHOENIX REALTY HOMES
Extelinal static pressure
Pres$ure losses
Avail le static pressure
Supp`y / return available pressure
Lowest friction rate
Actual air flow
Total ;effective length (TEL)
Heating
0.30 in H2O
0 in H2O
6.30 in H2O
0.150 / 0.150 in H2O
0.359 in/100ft
593 cfm
Job: LOT 7 TARPON FLATS M...
Date: Jan 29, 2016
By: RH
Cooling
0.30 in H2O
0 in H2O
0.30 in H2O
0.150 / 0.150 in H2O
0.359 in/100ft
593 cfm
84 ft
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(cfm)
FR
(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
Bd7 3
c 2506
86
116
0.399
6.0
Ox 0
VIFx
5.1
70.0
Bdrm 3 WIC
h 806
38
25
0.359
4.0
Ox 0
VIFx
13.5
70.0
Bdrni4
h 3046
144
132
0.370
7.0
Ox0
VIFx
11.0
70.0
Lounge
C 6124
274
284
0.391
9.0
Ox0
VIFx
6.8
70.0
sharedsthrm
h 1100
52
36
0.367
5.0
OXO
VIFx
11.7
70.0
Name
Grill
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diann
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rbi
Ox 0
593
593
0
0
0
0
Ox 0
VIFx
9
wri htSOft® 2016-Jul-2811:30:27
��� Right -Suite® Universal 2017 17.0.03 RSU24009 Page 3
... TarponFlatsModelB\Lot7Trp aonFlatsModelBGLNE.rup Calc = MJ8 House faces: NE
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
F
DRESS: 3913 Shoreside Drive Permit Number:
Fort Pierce, FL, 34949
MANgATORY REQUIREMENTS See individual code sections for full details.
461.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
[Section 553.9085, Florida Statues] requires the EPL display card to be included as an addendum to each sales contract for both presold and
n)npresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
i stalled in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
aid specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix C.
402.4 Alr leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
S ctions R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction.
Where required by the code official, an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
O R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
E3 R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing (Mandatory)AII ducts, air handlers, and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction
oe, rough -in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99, Florida Statutes, or as authorized by Florida Statutes, to be "substantially leak free" by either of the following:
1. Post -construction test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area
i when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All
register boots shall be taped or otherwise sealed during the test.
2.1 Rough -in test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g. (25Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be
i taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm
(85 Umin) per 100 square feet (9.29 m2) of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
7/28/2016 10:56 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 1 of 3
R405-2014
DATORY REQUIREMENTS - (Continued)
❑ 403.2.3 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ F 403.3 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105IF (41 °C)
or below 55'F (13°C) shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping Insulation.
❑ 11403.4.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily
a cessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑F 403.4.3 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
h gat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
d wnward and upward bend of at least 31/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ F403.4.4 Water heater efficiencies (Mandatory).
p R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum
temperature setting range shall be from 100'F to 140°F (38°C to 60'C).
• R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol, Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
R403.6 Heating and cooling equipment (Mandatory). The following sections are mandatory for cooling and heating equipment
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors
which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
7/28/2016 10:56 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 2 of 3
FORAM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and
shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling -only equipment. This
selection shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry bulb temperature for the
load calculation (or entering water temperature for water -source equipment), the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multi -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
When signed and sealed by a Florida -registered engineer, in attached single- and multi -family units, the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
• R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied through energy service to the building, shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55'F, and no precipitation is falling
and an automatic or manual control that will allow shutoff when the Outdoor temperature is above 40°F.
❑ R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15. The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting:
• R403.9.1.1 Gas and oil -fired pool and spa heaters. All gas- and oil -fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
• R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment (Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
higI efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: -Low-voltage lighting shall not be required to utilize high -efficacy lamps.
O R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19. Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
7/28/201610:56 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 3 of 3
FORM R4Ub-ZU14
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Rroject
Name: Lot7TarponFlatsModelBGLNE Builder Name: PHOENIX REALTY HOMES
Street:
3913 Shoreside Drive Permit Office:
City,
State, Zip: Fort Pierce, FL, 34949 Permit Number:
6wner:
6esign
Jurisdiction: 661000
Location: FL, ST LUCIE_CO_INTL
COMPONENT
CRITERIA
CHECK
Air
barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
'
gasketed doors
7/28/201610:56 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1