Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUMMARY
RIGHT-J LOAD AND EQUIPMENT SUMMARY File name: CHAMBERS . BLD 0 7 / 10 / 9 8 - For: ' VE CHAMBERS dNN l3oot S • S�+D�ati K-ivew- foiLtvG ,'3e.W3C- ✓ FL DEA C4 PL. .. By: ACTION AIR CONDITIONING & HEATING, INC. 1688 SE VILLAGE GREEN DR.c�B ` PORT ST. LUCIE FIB 34952. (561) 337-6242 -aa.+N tLucie CounlY Job # -PAV CHAMBERS Wthr Fort Pierce FL J . Zone Entire House tr WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS Outside db: 42 Deg F Outside db: 90 Deg F Inside db: ;: 70 Deg F Inside db: 75 Deg F Design TD: ;' . 28 Deg F Design TD: 15 Deg F Daily Range L Rel. Hum, : 55 % Grains Water 55 gr HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING ' Bldg. Heat Loss 16565 Btuh Structure 26813 Btuh Ventilation Air 0 CFM Ventilation 825 Btuh Vent Air Loss 0 Btuh Design Temp. Swing 3.0 Deg F Dlesign Heat Load 16565 Btuh Use Mfg. Data y Rate/Swing Mutt. 1.00 INFILTRATION Total Sens Equip Load 27638 Btuh Method Simplified LATENT COOLING EQUIP LOAD SIZING Construction Quality Best Fireplaces 0 Internal Gains 920 Btuh Ventilation 1870 Btuh HEATING COOLING Infiltration 1689 Btuh Area (sq.ft.) 1690 1690 Tot Latent Equip Load 4479 Btuh Volume(cu.ft.) 13520 1352.0 Air Changes/Hour 0.3 0.2 ' Total Equip Load 32117 Btuh Equivalent CFM 68 HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY Make TRANE Make 'TRANE Model TWH 042 Model TWR042C-B Type elec Type ashp Efficiency / HSPF 100.00 COP/EER/SEER 10.15 Heating Input 16565 Btuh Sensible Cooling 27300 Btuh Heating Output 16565 Btuh Latent Cooling 12200 Btuh Heating Temp Rise 11 Deg F Total Cooling 3 950 0 Btuh Actual Heating Fan 1434 CFM Actual Cooling Fan 1434 CFM Htg Air Flow Factor 0.087 CFM/Btuh Clg Air Flow Factor 0.053 CFM/Btuh _ Space Thermostat Load Sens Heat Ratio 91 MANUAL J: 7th Ed. RIGHT-J: VI .3.0: 12 S/N 11818 - Printout certified by ACCA to meet all requirements of Manual Foim J. j 1818 SIN .. RIGHT-J SHORT FORM 0 7 / 10 / 9 8 File name: CHAMBERS . BLD Job #: '9AVE CHAMBERS Htg Clg ' For: DAVE CHAMBERS Outside db 42 90 ' " V Lo Inside db 70 75 lI FL Design TD 28 15 Daily Range - L - Inside Humid. - 55 By: ACTION AIR CONDITIONING & HEATING, INC. Grains Water - 55 1688 SE VILLAGE GREEN DR, Method Simplified PORT ST. LUCIE FL 34952 Const. glty Best (561) 337 `6242 Fireplaces 0 HEATING EQUIPMENT COOLING EQUIPMENT Make TRANE Make TRANE Model TWH 042 Model TWR042C—B Type elec Type ashp Efficiency / HSPF 100.00 COP/EER/SEER 10.15 Heating Input 16565 Btuh Sensible Cooling 27300 Btuh Heating Output 16565 Btuh Latent Cooling 12200 Btuh Heating Temp Rise 11 Deg F Total Cooling 39500 Btuh Actual Heating Fan 1434 CFM Actual Cooling Fan 1434 CFM Htg Air Flow Factor 0.087 CFiV~ Clg Air Flow Factor 0.053 CFM/Btuh Space Thermostat Load Sensible Heat Ratio 91 ROOM NAME AREA HTG CLG HTG. SQ.FT. BTUH BTUH CFM ATTIC / LOFT 420 5607 7909 485 " MISiC. AREAS 136 138 212 12 KITCHEN 96 98 1470 8 BATH 2 55. 631 775 55 BEDROOM 2 224 2229 3836 193 BEDROOM 1 224- 2229 3671 193 BATH 1 55 631 665 55 GREAT ROOM 480 5�002 8276 433 Entire House d 1690. 16565 26813 1434 Ventilation Air 0 825 Equip. @ 1.00 RSM 27638 Latent Cooling 4479 - TOTALS 1690 16565 32117 1434 MANUAL J: 7th Ed. RIGHT-J: V3.0.12 CLG CFM 423 11 79 41 205 196 36 443 1434. 1434