HomeMy WebLinkAboutEVALUATION REPORT - METAL ROOFINGEVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
'26 GA. IMAGE II PANEL'
R(p1, �.
FILE COPY
A NI-e,-
FLORIDA BUILDING CODE 6TH EDITION (2017)0u�
FLORIDA PRODUCT APPROVAL
FL 11560.5-R3
a�{vANN
ROOFING
�
� METAL ROOFING
St LUCK COti
CONCEALED FASTENERS OR ATTACHMENTS
ARE'TH� RESPONSIBILITY OF THE
36WRAGTOR OR RECORD
Prepared For:
Metal Sales Manufacturing Corporation
545 South 311 Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300� >'Z,�.
Fax:' (502) 855-4200 /�,�`-�� N
ST. LUC E OR COMPLIANCE
BUATNE DIV N
REVIEWED
THESE PLANS AND ALL PROPOSED WORK REVIEW R Y
ARE SUBJECT TO ANY CORRECTIONS DATE JOB
REQUIRED BY FIELD INSPECTORS THAT . PLAN ND PER IT MUST BE KEP
MAY BE NECESSARY IN ORDER TO SITE OR NO INSPECTIONS) WI E MADE
COMPLY WITH ALL APPLICABLE CODES- Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74.106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
°II1111�®�moe
Installation Details (1 Page) `:0 SOCKg4�®s,�`
Load Span Table (1 Page)®%``,�.I'C'E N •• N�, �.,
Report No. C2181-5
Date: 9.8.2017
4
No 62240 •: b
:mod
a
;•• /STATE OF •;��`�
v,�'•,(0 OP •=moo
Rta,.\,o
�m s A
11 soil
�.`�• 2c3 t"�
I �-1 /- tj�5q-;)
FL 11560.5-R3
C2181-5
9.8.2017
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Name: Image II
Panel (Description: Max. 16" wide coverage with 1" high ribs
Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck pescription: Iy1in:,.1KKA phew_ OOR Dr min. 3/4" thick wood plank (min SG of 0.42)
for new and existing constructions. Designed and installed as per FBC
2017.
Deck Attachment:
(Minimum)
Unde�layment:
I
Slope
Design Uplift Pressure:
(Factor of Safety = 2)
I
Fastener Pattern:
At pa Al, el seam
Sidelap Adhesive:
Test �tandards:
I
8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
in the field and edges. Designed as per FBC 2017.
Minimum underlayment as per FBC 2017 Section 1507.4.5.1
1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
84.25 psf @ fastener spacing of 24" o.c.
102.7 psf @ fastener spacing of 6" o.c.
139.1 psf @ fastener spacing of 6" o.c. with 3/8" bead adhesive in
panel sidelap
#10-12 pancake head screws along panel seam. Fastener shall be of
sufficient length to penetrate through the deck a minimum of 1/4".
Schnee -Morehead SM7108 Permathane adhesive
Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
The product described herein has demonstrated compliance with FBC
2017 Section 1507.4
is: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This evaluation
report is not applicable in High Velocity Hurricane Zone. Refer to
current NOA for use of this product in High Velocity Hurricane Zone.
FL 11560.5-R3
C2181-5
9.8.2017
Page 3 of 3
Fire classification is not within scope of this Evaluation Report. Refer
to FBC .2017 Section 1505 and current approved roofing materials
directory or ASTM E108/UL790 report from an accredited laboratory
for fire ratings of this product.
ing Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T241-07, Reporting Date 7/23/07
Hurricane Test Laboratory, LLC
HTL Report #: 0103-0714-09, Reporting Date 9/l/09
ROOF PANESEE DETAIL 1
L
MAX. 16"
PANEL FASTENER
SPACING PER ALLOWABLE
PRESSURE TABLE.
\IL
F
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURER'S INSTALLATION8
PLYWOOD
A2.5"LONG RING SHANK 19/32" THICK (MIN.)
o .'�
ROOF PANEL
�--MIN. 2X- WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O.C.
SEE DETAIL 2 ADHESIVE IN THE
�� - �� PANEL SIDELAP
SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENING PATTERN 1
MAX. 16"
PANEL FASTENER
SPACING PER ALLOWABLE
PRESSURE TABLE.
IL
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURER'S INSTALLATION
PLYWOOD
SD .U. - I" 1 RING SHA- o NAIL 19/32" THICK (MIN.)
\—MIN. 2X_ WOOD RAFTER/JOIST/ VV V�uLJ SPACED O 6" O.C. IN THE FIELD &
TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES
FASTENING PATTERN 2
TYPICAL PANEL INSTALLATION X-SECTION
MIN 26 GA. PANEL
#10-12 X 1" LONG
PANCAKE SCREWS
q
DETAIL 1 AT MAX. 6" O.C.
UNDERLAYMENT PLYWOOD
19/32" THICK (MIN.)
SIDELAP
NOM. 3
MIN 26 GA. PANEL
#10-12
PANCAK
D ETA I L 2 AT MAX.
UNDERLAYMENT
E
ADHESIVE
/8" BEAD
X 1" LONG
SCREWS SIDELAP ADHESIVE
6" O.C. LOCATION
PLYWOOD
19/32" THICK (MIN.)
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0167"). MAX. EFFECTIVE COVERING
WIDTH OF PANEL - 16".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING. _
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
d
00
V N
Z Ho
d m)cV O
NoO
{{Q V7Y I
Q wJoo
to = o
No
-J 'n
g
1 OF 1
PLYWOOD
19/32" THICK (MIN.)
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0167"). MAX. EFFECTIVE COVERING
WIDTH OF PANEL - 16".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING. _
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
d
00
V N
Z Ho
d m)cV O
NoO
{{Q V7Y I
Q wJoo
to = o
No
-J 'n
g
1 OF 1
i
METAL SALES MANUFACTURING CORPORATION
Image II Uplift Loads
(Min. 26 ga.)
Description
Fastener Spacing
along Panel Length
(in)
Allowable Uplift
Load
(pso
Coverage width: 16"
Panel Fastener:
#;10-12 pancake head screws
6
102.7
8
---- 100.7 -
98.6
96.6
94.5
_
10
12
14
16
92.5
_
18
90.4
20
88.4
86.3
84.3 - - -
22
- - 24
With Sidelap Sealant
6
139.1
Notes:
I
1. 1 The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 11560.5 and Metal Sales current installation procedure.
3. , Three or more spans condition.
1216 N Lansing Ave., Suite C
Tulsa, Ok 74106
918 492 5992
I
a�ecsaaae�Q�
1eo10 SOCKg4-e.,
�•.®�P,.•.�CE/jrs•�G� °ram
v. F • 9 m
NO 62240 •°'�
O •, STArE • cr
w
.J
C=1.1-1
Bala Sockalingam, Ph.D., P.E.
FL 62240