HomeMy WebLinkAboutNOADEPARTMEP
BOARD AND
NOTICE
Interwrap,
32923 Missi
Mission, B(
SCOPE:
This NOA
used in.
11FCF1VF0
e'er NOV 10
PRODUCTICONTROL�SEC COUNTY
T OF REGULATORY AND ECONOMIC RESOURCES (RER) t /U a Coun¢'n®nt" 118i Florida 3 6 Street, 3 75 2474
CODE ADMINISTRATION DIVISION y T (786)315-2590 F (786) 3152.5-99
OF ACCEPTANCE (NOA) www.miamidade.eov/economv
in Way FILE.C�PY BYCanada V2V-6E4St Lude County
�`16r
being issued under the applicable rules and regulations governing the use of construction materials. The
n submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
�i Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA hall not be valid after the expiration date stated below: The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right'to
have this pr duct or material tested'for quality assurance purposes. If. this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, mod fy, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fail to meet the requirements of the applicable building code.
This produc�is approved as described herein, and has been designed to comply with the Florida Building Code
including th High Velocity Hurricane Zone of the Florida.Building. Code.
DESCRIP ION: Titanium® UDL-30, Titanium® UD1-50, RhinoRoof U10, RhinoRoof_U20, Titanium UDL25
Synthetic Underlayments
LABELIN Each unit shall bear a permanent label with the manufacturer's nameor logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA"will occur after the expiration date or if there has been a revision or change in the
materials, uE e, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product;
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA� shall be cause for termination and removal of NOA.
ADVERTISIEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration d�te may be displayed in advertising, literature. If any portion of the NOA is displayed, then it shall be done
in its entire .
INSPECTI N: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-0603.18 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0814.09
Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category Roofing
Sub -Cate o : Underlayment .
Material: Polypropylene
SCOPE:
This acceptahce is for, Titanium® UDL-30, Titanium® UDL-50, , , , , , RhinoRoof U20, Titanium UDL25, and
Synthetic Underlayments as described in this Notice of Acceptance, for use with approved prepared roof assemblies . .
where AST11 D226 Type underlayment is specified and installed with prescribed approved fasteners and fastener
densities. Designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the.
Florida Building Code
PRODUCT
DESCRIPTION:
Test
Product
Pr
duct Dimensions"
Specification
Description
TitaniumO UDL-30
48" x 250'
rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & R
sides coated with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
Titanium® L
DL-50. 48"- x 250'
rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & II
sides coated with UV .protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
RhinoRoof
20 42" x 286'
rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I and II
sides coated with, UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
Titan�iu�m,UDL25'
48" x 250'
rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturi�ig
Type I and II
sides coated with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
RhinoRoof IJ10
42" x 286'
rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & II
sides coated with UV protected and. slip resistant
Location #1
polymer stabilized polypropylene on both sides.
MANUFACTURING
LOCATIONS:
1. ML2
NOA No.:,18-0814.09
MIAMI•DADE
COUNTY
Expiration Date: 08/09/23
Approval Date: 08/30/18
Page 2 of 4
EVIDENCE SUBMITTED:
Test
Agency Test Identifier Test Name/Report Date
Intertek Testing
Services #3031783 TAS 104 02/19/03
3119607COQ-003B ICC-ES AC48 02/20/08
3124826-01 ASTM E108 02/19/08
3124826MID-007 ASTM E108 02/25/08
311801000Q-003 ASTM D226 02/20/08
.3130639COQ-002A ASTM D226 02/20/08
3146738COQ-003A ASTM D226 06/20/11
3146738COQ-003B ASTM D 1876/ TAS 117 03/28/08
101465036COQ-001 ASTM D1970 06/27/14
100539395COQ-006 ASTM D226 06/02/14
101863861COQ-OOIA ASTM D226 10/28/14
101823107COQ-011 ASTM D226 12/09/14
Trinity I ERD
I15010.05.10 ASTM D4798 / D226 05/14/10
138010.08.11 ASTM D226 08/11/11
I35520.08.11 ASTM D2523 / D1781 08/17/11
INSTALLATION
SPECIFICATIONS:
Titanium®
i
UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments
1. Titanium®
UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments
shall be installed in strict compliance with applicable Building Code.
2. Titz
nium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments
shall be installed with a minimum 4-inch head lap in a shingle layer fashion.
3. Titanium®
UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments
shall be fastened with Miami -Dade approved corrosion resistant tin -caps and 12 gauge 1 '/4"
ann%lar
ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the
4. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments may be used with Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofing,
and quarry slate. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium
UD 25 Synthetic Underlayments shall not be used as roof tile underlayments.
5. For Roof Tile applications; may be used as an anchor sheet in roof tile applications when used in combination
wit a top membrane layer, consisting of a Miami -Dade approved TAS 103 self -adhering underlayment. (See
current NOA listing of approved TAS 103 self -adhering underlayment for installation guidelines and
limitations of use).
6. For fire classification of specific roof assemblies using Titanium® UDL-30, Titanium® UDL-50, RhinoRoof
Uly, RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments refer to a current Approved Roofing
Materials Directory for fire ratings of this product.
NOA No.: 18-0814.09
Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 3 of 4
PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. Th4 Notice of Acceptance.
2. Any, _other documents required by the Building Official or, applicable building code in order to properly
evaluate the installation of this material.
LIMITAT]
1. Fire
fire
2.
3.
4.
Un
the
5. Ti
6.
7.
8.
Uni
30,
a ci
Rhi
be:
for
upl
% All
NS:
classification is not'part of this acceptance; refer to a current Approved Roofing. Materials Directory. for
. atings of this product.
acceptance is for prepared roofing applications.. Minimum deck requirements shall be in compliance with
icable building code.
zium® UDL-30, Titanium(Z UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
erlayments shall be applied to a smooth, clean and dry surface with. deck free of irregularities. All nails.in
leck shall be carefully checked for protruding heads. Refasten any loose decking panels. Sweep the deck
)uglily toremoveany dust and debris prior to application.
zium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20,. and.Titanium UDL25 Synthetic
erlayments shall not be hot mopped, refer to- manufacturer's published literature for product compatibility.
iium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
erlayments shall not be applied over an existing.roof membrane. as a recover system.
iium®- UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20,. and Titanium UDL25, Synthetic
erlayments shall not be left exposed. as a temporary roof for longer,than 30 days of application.
1ium6 UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
erlayments are components used in roof system assemblies. Roof system assemblies are approved under a
ific Notice'of.Acceptance. Refer to Prepared Roofing system Product Control. Notice of Acceptance for
3 approval of this product with specific prepared roofing products.
iium® UDL-30,.Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
erlayments .may be used with any approved roof covering Notice of Acceptance listing Titanium® UDL-
Citanium® 1JDL-50, RhinoRoof U10- RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments. as
mponent part of an assembly in the Notice of Acceptance. If Titanium® UDL-30, Titanium® UDL-50,
ioRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments are not listed, a request may
lade to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department
Lpproval provided that appropriate documentation is provided to -detail compatibility of the products,.wind
I resistance, and fire testing results.
nembranes or packaging shall bear the imprint or identifiable marking of the manufacturer's,;name or logo
the following statement: "Miami -Dade County Product Control Approved" or the Miamiri de County I "
luct Control Seal as shown below..
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20=3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 18-0814.09
Expiration Date: 08/08/23
Approval Date:. 08/30/18
. Page 4 of 4