HomeMy WebLinkAboutFENCING SET UPx
R, a
I
—M—___-__
H
0
I-.-3%'�I d��a N '
x
r�
2 a
' a
a.
a�
CORE DRILL
grout
IN
GROUND
UI lv
75+>
d
SHOE MOUNT DETAIL
I I I
I 1
I I I 1
I I I I 1 I I I
I j I
I I I i t i �__, 3 SIDED POS7
iu I _ SNAP
3%" 5 1114 TEKS
IS E HEIGHT NEC SSARY All TO LpOTT SIDES OF fspST
ATTACH PLATE Tp OM OF CASTING
SLAB/FOOT ROV NECESSARY SARYMT ADJUST
MI
EXPANSION WITHFOURED MENT
CONCRETE
B°TOS ° li4'
BETE A MINIMUM OF T
1 1/2'
NOTE: Aluminum parts shall be welded with an
inert —gas —shielded arc or resistance welding
process. No welding .process that requires a
weldingflux shall be used. Filler alloys
compl}ing with the requirements of the standard CAST SHOE MOUNT
(FBC 2014) shall be used. All welding of
structural aluminum members shall be
performed by certified welders
ASSEMBLY
Top Cap and
Snap Plate
REM❑VEABLE FENCE SECTI❑N
J
'pickets screw
fastened to snap
plate and bottom
channel, snap
plate screw
fastened to
2'post and post
snap, all w/#lOXlY2 Snap plate snaps
hex —head into 3 sided post
sheet metal screw 2'Post and Snap
screw fastened
to Bottom Channel
w/#lOXli'2 hex —head
sheet metal screw
\.V4 SS
THRUBOLT
2.25'
2.25 SO X .095 SLEEVE
WALL MOUNT DETAIL
TYPICAL CAST
TOP WALL MOUNT
TOP CAP
Q
TOP CAP SLIDES LJ X
INTO WALL MOUNT U Q
2 ea. 2 ea. #10 SELF Y' TAPCONS iU
TAPPING MIN. IA'
SCREW PENETRATION
@ 1' MIN. /INTO CONCRETE
SPACING
0 0
CHANNEL SLIDES
INTO WALL MOUNT
TYPICAL CAST
BOTTOM CHANNEL BOTTOM WALL
MOUNT LEI
CONUAI ED PAS K ENERs 0IR AT. I
ARE THE RESPONSIBILITY OF.
THE
CONTRACTOR OF RECORD
.468'
1.21 °
2,468X1.219X,05
TOP CAP
I
050" ' 016'
2,016X.050
TOP CAP
SNAP PLATE
METAL
T10 6
6"
1 2X2X.066
3 SIDEDP❑ST
.065°
1.795-
1.795X.065
POST SNAP PLATE
STANDARD FENCE SECTI❑N
POOL. FENCE SECTI❑N
3Y4„
H-.
"
0.038 -
m 1045
.75X.75X,038 1.625X1X,045
PICKET - BOTTOM CHANNEL
1°
0.036
1X1X.036THESEPLANS AND ALL PROPOSED VJOr '
PICKET ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY MELD INSPECTORS THAT
KAY BE NECENA.RY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES,
STANDARD YARD GATE
POOL GATE
z ¢ W
F—
�� z_¢
ED d J
Q_ Ln CO
a_
(U d Wl_y
13Y
XU
ALL GATES INCLUDEUP TO 60' WIDE St Ludle Coul
:
2 EACH SELF -CLOSING HINGES
I GATE LATCH
ALL GATES FOR A POOL MUST HAVE LATCH MOUNTED 54, FROM THE
BOTTOM OF THE GATE.
ON 4FT HIGH POOL GATES, USE MAGNA LATCH OR APPROVED CHILD
SAFETYLOCK
ALL FASTENERS ARE #IOX 3/a' CERAMIC COATED (NON -CORROSIVE) SCREWS
1. EXTRUSIONS SHALL USEALLOY6061-T6OR 6005-T5
2. THE CONTRACTOR SHALL INSULATE DISSIMILAR METALS TO PREVENT
ELECTROLYSIS.
3. FENCE HEIGHT FOR POOL SHALL BE 48" MINIMUM.
4. FOOTING CONCRETE COMPRESSIVE STRENGTH SHALL BE MIN 2,500 PSI
IN 28 DAYS. '
5. THIS DESIGN MEETS OR EXCEEDS ALL APPLICABLE REQUIREMENTS .
Or, 2017 FLORIDA BUILDING CODE 6th EDITION l RESIDENTIAL 107.2.1
Mdah AI,UMINUMFENCING
PRINCE
)6al _060.
DEVELOPMENT GROUPLDATE
LUCIE COUN
3608 E. INDUSTRIAL WAY
RIVIERA BEACH, FL 33404DING
DIVIS
P: 561-840-3300
F: 561-855- 4821
REVIEW
COM IANC
A6Er Covlcrete P co1k# 18352
7832 SaAdie),rook,Drwe,
Y
ParrSt: Lu.c &, FL 34987 Lot91SatallCreek,
St Lua.&Caunly, FL
NSAND PERMIT
E KEPT ON J013 OR
CTION WILL'J� E MADE
FENCE 1/5/2018