Loading...
HomeMy WebLinkAboutTRUSS PAPERWORKMiTek RE: M11439 MANOR 71 Site Information: Customer: WYNNE DEVELOPMENT Lot/Block: Address: UNKNOWN City: ST LUCIE COUNTY Project Name: M11439 Model: MANOR 71 Subdivision: State: FL MiTek USA, Inc. 6904 Parke East Blvd. Tampa, FL 33610-4115 SCANNED BY St Lucie County General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 16 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T15168861 a 9/25/18 2 T15168862 a1 9/25/18 3 T15168863 a2 9/25/18 4 T15168864 a3 9/25/18 5 T15168865 a4 9/25/18 6 T15168866 a5 9/25/18 7 T15168867 a6 9/25/18 8 T15168868 a7 9/25/18 9 T15168869 b 9/25/18 10 T15168870 bha 9/25/18 11 T15168871 grb 9/25/18 12 T15168872 jt 9/25/18 13 T15168873 13 9/25/18 14 T15168874 15 9/25/18 15 T15168875 7 9/25/18 16 T15168876 VP 9/25/18 FILE COPY DEC 0-4 2018 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision 1 r r r t t t t ``� ttt based on the parameters provided by Chambers Truss. ,���0 QV�. V.. �� Truss Design Engineer's Name: Velez, Joaquin ��� •, N S ,•� ,�•� My license renewal date for the state of Florida is February 28, 2019. P Florida COA:6634 182 IMPORTANT NOTE: The seal on these truss component designs is a certification — 't that the engineer named is licensed in the judsdiction(s) identified and that the % designs comply with ANSI/rPI 1. These designs are based upon parameters % S ATE OF 41J Z shown (e.g., loads, supports, dimensions, shapes and design codes), which were . given to MiTek. Any project specific information included is for MiTek file reference only, and was not taken into account in the of 0 • A, ••• O ���� customers purpose preparation i� O R 1 •,•' SS these designs. MlTelk has not independently `� ara for particularuse, the parametersBeforeoperly tedfy r tapplicability designs ',fit N Apil� E d design d eta these designsdesigner into the overall building design per ANSI/TPI 1, Chapter 2. Jmq in Velez PE No,66182 We USA, Inc. F Can 6634 6904 arke East 6 d. Tampa FL 33610 September 25,2018 1 of 1 Velez, oaqui Job Trues Truss Type ay Ply MANOR 71 T1516BB61 M11439 A Common 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, R. 4.00 F12 4x4 = 8.130 s Mar 11 2018 MiTek Indumries. Inc. Tue Sep 25 08:36:56 2018 Scale = 1:59.3 tIm 6 3x4 = 3x6 = are = 2r3 II SM = 3x4 = 314 o I M = LOADING (pet) SPACING- 2-0-0 CSI. DEFL in (lac) I/deft Vd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.33 Vert LL) -0.13 14-15 >999. 380 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.36 Ven(CT) -0.25 14-16 >999 240 BCLL 010 ' Rep Stress Incr YES WB 0,52 Horz(CT) 0.02 14 n/a Na BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wlnd(LL) 0.10 17.20 >999 240 Weight. 166 lb Fr=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 541.5 oc punins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6.0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1Row at micipt 6-14 REACTIONS. All bearings 0.8.0. (lb) - Max Horz 2=-179(LC 10) Mail All uplift 100 Ib or less at joint(s) 12 except 2=-47C(LC 12), 14=-9D4(LC 12), 10=-186(LC 12) Max Grav All reactions 2501b or less at joints) except 2=731(LC 1), 14=1562(LC 1), 12=342(LC 22), 10=266(LC 22) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-14611958, 3-5= 1282/878, 5-6=-639/551, 6-7=-261/745, 7-9=-379/723, 9-101 BOT CHORD 2-17=-797/1413, 15-17=-410/878 WEBS 3-17=.316/317, 5-17=-333/545, 5-15=-572/515, 6-15=-508/854, 6-14=-1202F707, 7-14— 269/324, 9-14=-529/449 NOTES- 1) Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=151t; B=71ft; L=35ft; save=5ft; Cat. II; ENS C; Encl., GCpi=0.18; MWFRS (directional) and CC Exterior(2) -1-0.0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 1780 to 21-0-0 zone;C-C for members and farces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip D01_=1.60 3) This truss has been designed for a 10.0 psi bottom chord live load nonponcuream with any other live loads. 4) ' This truss has been designed for a live load of 20.01 on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, With BCDL = 1 O.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 12 except (jt=lb) 2=470, 14=904, 10=186. Joaquin Velez PE No.68182 MiTsk USA, Inc. FL Can 8634 6904 Parke East Blvd. Tampa FL 33010 Date: September 25,2018 ,,&WARNING-Verifyd"J9.PanmMneend READ NOTES ON MEANDWCLUDEDMITEKREFERANCEPAGEM/F74n nv. iWa 75BEFORE USE. Design valid for use only with MITekit connectors. This design Is based only upon parameters shown, and a far on Indlvltlual building component, not ad!a hens system. Before use, the building designer must verify the applicability of design parameters and prapa ly Incaporafe the design Into the overall ly. AddlNorwl tempoearyand permarsani ocIng MiTek buildingdesign. Bracing indicated is tc, preventbuckling of indtvidual tnnsweb and/or Chord mernlear Is always required for liability and to prevent collapse with possible personal Injury and property damage. or general guidance regarding the faladcatlonn, stwage, delivery, erection and beating oftrwoes and truss systems, seeANSVIPH OWIBr CmBM, DSB49 OM ICA luldeq Component 'JI A N, m churl e,,Ie Al 9 AlWr VA 99. 14 6904 Parke Esst Blvd.erer Tampa, FL 33610 Job Tines Tres Type Oty Ply MANOR 71 T75768862 M11439 Al Carcnon 7 1 Job Reference o tional Chambers Tnes, Inc., Fort Plebs, FL N_. tl.Tau s Mar 11 zUl o MI I ex InauslnBB, IBC. 1IIB JBp 25 Utl:36;5tl 2U1 tl Scale = 1:59.5 4.00 12 bxs _ 6 17 .- 15 14 12 316 = 2x3 II 4x6 = 3x8 = 2x3 II 3x8 = 3x8 = 416 = LOADING (psi) SPACING- 2.0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2017/rP12014 CSI. TC 0.72 BC 0.76 WB 0.68 Matrix -MS DEFL. Vert(LL) VeA(CT) HOr2(CT) Wind(LL) in (loc) Vdefl L/d -0.31 14-15 >999 360 -0.65 14-15 >646 240 0.13 10 Ne Ma 0.3514-15 >999 240 PLATES GRIP MT20 244/190 Weight: 166 So FT=20%. LUMBER- BRACING. TOP CHORD 2x4 BP M 30 TOP CHORD Structural wood sheathing directly applied or 3.1-4 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-9-5 Go bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1424/0-8-0, 10=1424/0-8-0 Max Hoa 2=-179(LC 10) Max Uplift 2=-868(LC 12), 10=-868(LC 12) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3481/2332, 3-5=-2886/2019, 5-6=-2886/2123, 6-7=-2886/2123, 7-9=-2888/20lg, 9-10=-3481/2332 BOT CHORD 2-17=-2073/3261, 15-17= 207=61, 14-15=-128W2118, 12-14=-2088/3261, 10-12=-2088/3261 WEBS 6-14-544/984,7-14=-252/310, 9-14=-677/504, 6-15=-644/984, 5-15=-252J310, 3.15=-677/504 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VUIt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=71ft; L=35111; eave=5ft; Cat. 11; Exp C; Encl.. 118; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-", Interior(1) 2h" to 17-6-0, Exterior(2) 17.6-0 to 21-0.0 zone;C.0 for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrem With any other live loads. 4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas Where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100111 uplift at joint(s) except Qt=lb) 2-868, lD=868. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 75 lb down and 70111 up at 15-0-0, and 75111 down and 70 Ib up at 20-0-0 on top chord. The desigrilselection of such cannection device(s)is the responsibility of others. LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-6=-54,6-11=-54, 18.21=-20 Concentrated Loads (Ib) Vert: 26=-75 27= 75 Joaquin Velez PE No.68182 MiTek USA, Ina FL Cart 66U 6904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 Q WARNING - Verffydee/gnperematins.d REAGNGTESMN ANDNCLUBEDMNEKREFERANCEPAGEW?4"-- lBOYA15BEFGREUSE Design valid for use only with Meek® connectors, This design Is based only upon parameters shown, and Is for on Intllvidual building component, not �,- a hUH system. Before use, me Wilding designer must verity the opplicablkly of design parameters and property incapable this design into the overall buckling individual truss only. AddBlorgl temporary and permanent bracing MiTek building deslgn. Bracing indicated is to prevent of web and/or chord members Is always recurred for stability Gntl to prevent collapse with possible personal INury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses art Ines systems seeArl Ml plreiy CMft D=49 ale Kill arraAq Celnpenrrnl Safety Infamlldlsonavolioble from Truss Plate Institute, 218 N� Lee Street. Suite. 31R Alexandria, VA 22314� sks" Fable East Blvd. Tamps, FL 3361a Job Truss Truss Type OtY Ply MANOR 71 T15188863 M11439 A2 Roof Spada] 8 1 - Job Reference 'oral Chambers Truss, Inc., Fort Pierce, FL iI en:N s marl Lida MI I arc Inausul no, 1 us Jep za ua:ao:ae zule Scale=1:60.3 4.00 12 4x5 = 0 is 14 uox � 1 315 - 2x3 11 ixe — 2.00 12 3x12 = LOADING (psi) TOLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 CSI. Plate Grip DOL 1.25 TC 0.72 Lumber DOL 1.25 BC 0.97 Rep Stress I= YES WR 0.93 Code FBC2017/rP12014 Matrix -MS DEFL. In (too) Vdefl L/d Vert(LL) -0.58 12 >725 360 Vert(CT)-1,0712-21 >393 240 HorA(CT) 0.39 10 WE Na Winl 0.80 12 >527 240 1 PLATES Mr20 Mi1BHS Weight. 1621b GRIP 244/190 244/790 FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 24-2 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-13 REACTIONS. (IWsize) 2=1349/0-8-0, 10=1349/0-8-0 Max Holz 2=-179(LC 10) Max Uplift 2=-825(LC 12), 10=-825(LC 12) FORCES. (to) -Max. Comp./Max. Ten. -All forces 250111 or less except when shown. TOP CHORD 2-3=3317/2151, 3-5=-2562/1755, 5-6= 2355/1675, 6-7=-2377/1650, 7-9=-5276/3414, 9-10=-5681/3671 BOT CHORD 2-15=-1911/3110, 14-15=-1911/3110, 13-14=-1428/2418, 12-13=3088/5%2, 10.12=-3410/5408 WEBS 3-15=0/302,3-14=-804J562,5.13=-357/270,6-13=-730/1177, 7-13=-3077/1999, 7-12=-1105/1963, 9-12=403r372 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=166mph (3-second gust) Vesd=128mph; TCDL=4.2pst; BCDL=3.OpsY h=15ft; B=71ft; L=35ft; save=5ft; Cat. II; Exp C; Encl., GCpi=0.10; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17.6-0, Exlerior(2) 17-6-0 to 21-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=7.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle M-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift at tortilla) except all 2=825,10=825. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6034 6904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 O WARNING-Verlrydeelgn"remereraend READNOTES ON THIS AND/ NCLUDEDMIrEKREFERANCEPAOEMIF7479rev. 1MM15 BEFORE USE. this design Is based upon shown, and a f@r an Individual building component, not ��- Design valid for use only with Meek® connectors. only parameters a truss system. Before use. the building designer must ve4ty me oppecabllity of design parameters and pm§prly Incorporate riles design Into me overall building design. Bracing Indicated is to prevent buckling of Indt iclual truss web and/or cl members only Addilional temporary and permanent bracing s always required for stabll ty and to prevent collapse with possible personal Injury and property damage. F, r general guidance regarding me M iTe k fabrication, storage, delivery, erection and bracing of trusses and truss system& seeANM/IPII QualMv OMHIe, D6eai and BOO BUWkp Compmmt kneakkfWvd pd9 from Truss Plate Institute. 218 N. Lee Street Suite 312, A wancum VA 2231A. 6904 Parke East Blvd,eaeetyrb Tampa, FL 33610 Job Truss Truss Type Oly Ply MANOR 71 T15168864 M11439 A3 Hip 1 1 • Job Reterewe (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Tue Sep 25 OB:37:00 2018 Scale = 1:62.3 4.00 12 4xt — Us 8 7 2If m d 17 16 3x4 = 3x6 3x12 = 3x5 = 2x3 5x8 = 2.00 12 LOADING lost) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) -0.58 13-14 >721 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.97 Ved(CT) -1.0613-14 >395 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress her YES We 0.86 Horz(CT) 0.30 11 are n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.8013-14 >526 240 Weight: 1691b FT=20% LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathingdirectly applied or 24-6 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt a-14 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 11=1349/0-8-0 Max Hom 2=175(LC 11) Max Uplift 2=-825(LC 12), 11= 825(LC 12) FORCES. (fall - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3318/2236, 3-5=-2558/1847, 5-6= 2401/1786,6-7=-2265/1737, 7-8=-2422/1761, 8-10=-5275/3598, 10-11=-5687/3847 BOT CHORD 2-17=-2010/3111, 16-17=-2010/3111, 15-16=-1531/2419, 14-15=-1319/2240, 13-14=-3269/5065,11-13=-3578/5413 WEBS 3-17=0/304, 3-16=-807/565, 5-15= 320/270, 6-15=-489/605, 7-14=-352/592, 8-14= 3047/2096,8-13=-1175/1985,10-13=-408/379 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasi 28ni TCDL=4.2psf; BCDL=3.OpsY h=1511; B=71ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-0-0, Exterior(2) 17-0-0 to 18-0-0, Interior(1) 22-11-6 to 36-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.80 plate grip D0L--1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.0ps1 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joints) 11 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 It, uplift at joint(s) except (jt=1b) 2=825, 11=825. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 8834 6904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 Q WARNING. Vedrydealgn Parameters and HEAD NOTES ON MMAND&CLUDEDMDEKREFERANCEPAGEM&M73mw. laG ISeEFOREUSE. Design valid for use only with MRek® connectors, This design is based only upon parameters shown, and Is for gn Individual building component, not a truss system. Before usethe building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall buildingdesign. Bracing indicated Is to prevent buckling ofIndividual truss web and/or ohordmembers only OtldBlonoltemporary and permanent bracing MiTek' s always required for stablllN and to prevent collapse with possible personal Injury and property damage. F6f general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, eeeANEirlil Quality CdbAd, 0314W and BCN Building Component III Imarmationa llable from Truss Plot. Institute, 218 N. Lee Sheet, Suite 312. A ssr.r drlc, VA 22314. 69N Perko East Blvd. Tampa, FL 33610 Truss Truss Type Oty Ply MANOR 71 T15168865 FJob A4 Hip 1 1 ,..d Job Reference o tional T., ce., oc no.a7.mm en Pa 1 Chambers Truss, Inc., Fort Pierce, FL cif 0 4.00 12 3.4 5 4x8 = 4x8 = °zA?N?xeHveil l-2zNFMILI b9PaIZV6NNXJln72dedSBjHCIAZMUbyaBW 0 Scale = 1:62.3 1715 3x4 = axlz = 3x5 = as 11 5xB = 2.00 F12 LOADING (psf) SPACING- 2-0-0 CS]. DEFL, in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) -0.53 13 >792 360 MIT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.97 Vert(CT)-0.9913-23 >423 240 MT18HS 244/190 BCLL 0.0 Rep Stress Inch YES W B 0,74 Matrix -MS Hoa(CT) 0.36 Wind(LL) 0.73 11 n/a n/a 13 >575 240 Weight; 1701b FT=20% BCDL 10.0 Code FBC2017/TP12014 LUMBER- BRACING - TOP CHORD Structural wood sheathing directly applied or 2-4-13 do pudins. TOP CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP M 30 WEBS 1 Row at midpt 8-14 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 11=134910-8-0 Mau Horz2=155(LC 11) Max Uplift 2=-825(LC 12), 11=-825(LC 12) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3316/2376, 4-5=-2563/1968, 5-6=-2462/1977, 6-7=-2800/2203, 7-8=-2948/2252, 8-9=-5229/3788, 9-11=-5692/4100 BOT CHORD 2-17= 2144/3109, 16-17=-2144/3109, 15-16=-1635/2413, 14-15=-1547/2362, 13-14= 3431/5004, 11-13=-3821/5419 WEBS 4-17=0/301, 4-16=-806/577, 5-15=-225/264, 6-15=-239/292, 6-14=-476/680, 7-14=-406/661.B-14=-2564/1843,8-13=-1246/1955, 9-13=-463/433 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VuIt=165mph (3-second gust) Vasdl28mph; TCDL=4.2psf; BCDL=3.Opsf; h-15tt: B=71ft; L=35ft; eave=5ft; Cat. II;. Exp C; Encl.. GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0. Interior(1) 2-6-0 to 15-0-0, Extenor(2) 15-0-0 to 20-0-0, Interior(1) 24-11-6 to 36-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live lead of 21 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will tit between the bottom chord and any other members. 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=825,11=825. Joaquin Velez PE No.68102 MIT& USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 WANNING-Vanity deefgn Pammefenane BEAD NOTES ON MMAND INCLUDED MREKBEFEBANCEPAGE Mk9473 rev. 14MV1erS BEFOBEUSE. sign valid for use only with MITek®conneciors, fits design Is based only upon parameters shown, and Is fdl An Individual building component, not MR vss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall WOW titling design. Bracing indicated is to prevent buckling of Individual hues web and/or chord members only. Additional temporary and permanent bracing Ilways required for stability and to prevent collapse with possible personal injury and property damage, W general guidance regarding the 6904 Parke East Blvd. xication. storage. delivery, erection and bracing of trusses and truss systems, seeANSIM11 Du Cm•dBr Pasa9 and BGI Wlelnp COmp•D•m Tampa, FL 33610 I•H InformeNDrnvallable from Truss Plpte Institute, 218 N. Lee Sheet, Suite 312, Alexandria, VA 22314, Job Truss Trues Type City Ply MANOR 71 T75168886 M11439 AS Hip 1 1 - Job Reference tonal Chambers Truss, Inc., Fort Pierce, FL 5.130 9 Mar 11 2018 MITek Industries, Inc. TUG 08:37:02 2018 Scale=1:61.3 3x6 II 3x6 = 4.00 R-2 4 5 24 3X4 — 45 = 4x6 c 625 28 27 7 8 15 14 3x5 = 2b 11 111 = 2,00 r2 3,112 7-7-15 137.8 22-60 29.1I2 28-9.8 354}0 TJ-15 5-01•g &48 t•11.12 2•g-13 8.2.7 Plate Offset$ (X Y)-- t2:0-1-6Edae] l4.0-3-0D-2.81 f 10:0.1-15 EduaI LOADING (psf) SPACING 2-M CSI. DEFL in Ill Well Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TO 0.71 Vsrt(LL) -0.53 12 >799 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.97 Ved(CT) -0.99 12-21 >426 240 MT18HS 2441190 BCLL 0.0 Rep Stress Incr YES WB 0.72 Hom(CT) 0.35 10 Na Na BCDL 10.0 Code FBC2017frP12014 Matrix -MS Wind(LL) 0.72 12 >680 240 Weight: 1601b FT=20% LUBBBEW TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural mod sheathing directly applied or 2-4-15 ac puffins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (Borsize) 2=1349/0-8-0, 10=1349/0-8-0 Max Hom 2=-136(LC 10) Max Uplift 2=-825(LC 12), 10=-825(LC 12) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3302/2424, 3-4-2589/1988, 4-5=-2410/1948, 5-6--2430/1959, 6-7=-3580/2713, 7-8=-3728/2795, 8-9— 5216/3822, 9-10=-5695/4205 BOT CHORD 2-15=-2188/3094, 14-15=-2188/3094, 13-14=-2124/3102, 12-13=-3448/4977, 10-12=-3922/5422 WEBS 3-15=0/288, 3-14=-756/612, 6-14=-95W55, 6-13=-373/685, 7-13=-697/994, 8-13=-2051/1540,8-12=-1293/1901, 9-12=-474/482,5-14-381/608 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psfp BCDL=3.Opsf, hai B=71ft; L=35R; eave=5fe Cat. II; Exp C; Encl., GCpl=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 13-0-0, Extedor(2) 13-0-0 to 27-0-9, Interpol) 27-0-9 to 36-0-0 zoni for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water prancing. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 pat bottom chord live load norosoncumers with any other live loads. 6) " This truss has been designed for a live load of 20.01 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joints) 10 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except 01=11b) 2=825, 10=825. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: September25,2018 Q WABNMO-Verity MMSn MIem4bld arM READ NOTES ON TNre ANOWCLUDEDN KRE ANDEPA0EYN74n9 feAYAete BEFODEUSE Design valid for use only with MITek® connectors, This design Is based only upon parameters shown, and Is for on mtlNldual building component, not a truss system Before use, the building designer must verity the applicability of design Parameters and properly Incorporate this design Into the overall Anal temporary and permanent bracing MiTek" Wilding tleslgn. Birdsong Indicated Is to prevent buckling of IndNldual from web and/or chord members only n always recurred for stobilily and to prewirmcollapse with possible personal injury one property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and buss systems seeANY/MI'A 22y CrMM, P�M asa IICN MSIrBrg Componws0 Bafaty InfaIDOtbrgvolable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandtla. VA 22 14, Sears venue Eon Blvd. Tempe, FL Marc Job Truss Truss Type Oty Ply �MMOR71 T15163867 M11439 A6 Hip 1 1 " Job Reference (olnionell e nasrno xa 1 rU65, ma., 1-0111 rlerals, 1-1- 5x8 = SIX5 = A= F12 4 5 24 25 ea JU a Nlar II zul a MI 1 eK Industries. Inc. 1 us 3x4 - 5x8 MT18HS= a 26 7 run Scale=1:61.3 15 14 13 3x4 SX6 = w II SO = Sza = 3x12 = 2.00[12 _ 7.7-2 11-60 13->s 7.8 10-a 23c.t-1142 24-0.028.8-1 35-0-0 a - I 8-1co-� Plate OBsets(X,Y)-- [2:D-D-2,Edoe1 [4:0.5-40.2-8] [7:0-4.00-2-31 [9:0-1-15Etl0e] [730.2-00.26] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Wall Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Veit(LL) -0.56 11.12 >748 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.97 Ven(CT) -1.0311.21 >408 240 WISHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.62 HOR(CT) 0.36 9 n/a n1a BCDL 10.0 Code FBC2017/rP12014 Matdx-MS Wind(LL) 0.78 11-12 >542 240 Weight. 1621b FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2.3-13 ad puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-6-0 Max Horz 2=-117(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 260 (Ib) or less except when shown. TOP CHORD 2-3=-3312/2471, 3-4=-2801/2173, 4-&=-2937/2307, 56=-4027/3051, 6-7=-4954/3675, 7-8= 5236/3830, 8.9=-5685/4263 BOTCHORD 2-15=-2231/3105, 14-15=-2231/3105, 13.14=-1815/2626, 12-13=-2030/2953, 11-12=-2817/4091, 9-11=-3974/5411 WEBS 3-15=-1/266, 3-14=613/527, 4-14=-2821373, 4-13=-455/612, 5-13=-833/718, 5-12=-896/1276, 6-12=-675/575, 6-11=-670/1D04, 8-11=-440/553, 7.11=-997/1469 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst BCDL=3.Ope1; h=15tt; B=71R; L=35tt; save=5f; Cat. 11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and CC Extedor(2) -1-0-0 to 26-0, Intedor(1) 2-6-0 to 11-0-0, Exterior(2) 11-0-0 to 28-11-6, Intedor(1) 28-11-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joints) 9 considers parallel to grain value using ANSV7PI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at loint(s) except Ot=lb) 2=825, 9=825. Joaquin Velez PE No.68182 MTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: September25,2018 A�WMN G-VeftydeslgnpnmrenwsmdREAONOTESONTM AND INCLUDED,m EKREFERANCEPAOEW7479roy. 1411=16BEFORE USE. Design valid for use only with Meek® connectors. This design b bossed only upon parameters shown, and Is far an Individual building component, not a truss system. Before use the bulalng destaner must verify the appllcablify, of design parameters and properly Incorporate rub design Into the overall budding design. Bracing Indicated Is to buckling of eWWlaud lnsa web and/or chord members only. Additional temporary and permanent brocitg MOW prevent Is always required for stability and to prevent collapse with poalWe personal Injury and property damage For general guidance regarding the falxaaXon, storage, tlellvery, erection and bracing of trusses and truss systems, seeAN991911 Guo2Itl1y CINda. D61149 and SCR Balding Component 6e04 Parke East BNd. feel dasmcffi 1 dlable from Truss Rate Institute. 218 N. Lea Street, Suite 312. Alexandra, VA 22314. Tampa, FL 33610 Job Truss Truss Type Oty Ply MANOR 71 T15168868 NI 1119 A7 Hip 4 1 - Job Reference (optional) amv oe,.e � unamDers I rural Ina., Pan race, rL 4.00 F12 ID;AJIomcaggFaOsPzA?N?xsHyei1l-SY30_mOVu4n991 Dh3V40w 4x8 = 2x3 11 3.6 = 3.4 = 4x8 = 2x3 .,..�.� 4 526 6 7 27 8 9 Scale = 1:60.5 D 3x4 — 3x4 = Spire 6xe = 3x4 = Biel = 3x4 — 3x4— 9.0.0 9-OA 13-6-0 4-8-0 IV-lu-u 6-2.0 0-2-0] [10�0-1-2 Edae] 8-2-0 9-0-0 Plate Offsets (X Y)-- [2:0-0-14 Edgel [4�0-5-4 0-2-01 [8,0-5-4 LOADING (psp SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl LJd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) -0.13 12-23 >999 360 MT20 244/190 TCDL 7.0 Lumber COL 1.25 BC 0.41 Vert(CT) -0.2912-23 >884 240 BCLL 0.0 ' Rep Stress Inor YES W B 0.53 HOr3(CT) 0.03 10 rda Na BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.1312-23 >999 240 Weight: 161 to FT=20% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=362/0-8-0, 15=1620/0-8-0, 10=716/0-8-0 Max Hoe 2=97(LC 11) Max Uplift 2=-256(LC 12), 15=-933(LC 12), 10=-460(LC 12) Max Grav 2=390(LC 21), 15=1620(LC 1), 10=731(LC 22) BRACING - TOP CHORD Structural wood sheathing directly applied or 5-8-3 oc puffins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1Row at midpt 7-15 FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-355/278,4-5=-521/823, 5-7=-521/823, 7-8=-646/514, 8-9=-1155/896, 9-10=-1409/1091 BOT CHORD 2-17=-160/325, 14-15=-280/646, 12-14=-638/1078, 10-12=-938/1311 WEBS 3-17=-396/473, 4-17=-310/444, 4-15=-942/713, 5-15=-326/367,7-15=-1554/1143, 7-14=-128/406, 8-14=-516/399, 8-12=-283/444,9-12=-355/436 NOTES- 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=71ff; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.1$ MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(i) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except Qt=lb) 2=256,15=933,10=460. Joaquin Velez PE No.li MiTek USA, Inc. FL Celt 6634 6004 Parka East Blvd. Tampa FL 33610 Data: September 25,2018 O WARNING -Val design Personal and READ NOTES ON THIS AND NCLUDED efil REFERANCE PAGE aI&l rev. 1aN32015 BEFORE USE. � Design valid for use only with MITek@ connhis contractors. Tdesign Is based only upon parameters shown, and is to[ on Individual building component, not s and prop6f y Incorporate this design Into the overall a truss system. Before use, the building designer must verify Me applicability of design parameter bulltlingdesign, Bracing Indicated is to prevent buckling of Individual hla uweb and/or chord members only Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. d r, general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seaANSVrPII Quality C"A P3149 and Ill Bull Component 6904 Parke East Blvd. Safety Intormatlanivailable from Truss Plate Institute, 218 N, Lee Street, Suite 312, Alexandra, VA 22314 Tampa, FL 33610 Job Truss Truss Type Off, Ply MANOR 71 T15168869 M11439 B Roof Spedal 7 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 4.00 12 5x10 = 3x5 = __._ — _'... $ Mar 11 2018 MI f ek Industries, Inc. Tue Sep 25 08:37:05 2018 Scale = 1:60.3 2 LOADING (part SPACING- 2-0-0 CSI. DEF4 in (too) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) -0.55 13 >764 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 SC 0,97 Vsd(CT) -1.02 13-24 >412 240 MT18HS 2441190 BCLL 0.0 ' Rep Stress Incr YES we 0.80 HOrz(CT) 0.38 11 1 rJa BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.76 13 >656 240 Weight: 173 Ib FT=20°h LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-9 oc pudins. BOT CHORD 2x4 SP M 30'Except' BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. 7-15:2x4 SP No.3 WEBS 1Row at midpt B-14 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-B-0, 11=1349/0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-825(LC 12), 11=-825(LC 12) FORCES. (lb) -Max. Gomp./Max. Ten. -All tortes 250 (lb) or less except when shown. TOP CHORD 2-3=-3345r2225, 3-5=-2959/1946, 56--2099/1519, 6-7=-274511985, 7-8=-2791/1918, 8-10=-5241/3361, 10-11=-5691/3687 BOT CHORD 2-18=-1995/3150, 16-18= 1479/2456, 7-14=-206/271, 13-14=-3019/5016, 11-13=-3425/5418 WEBS 3-18=-474/463, 5-18=-238/563, 5-16=-705/569, 6-16=-413/224, 10-1'.=-463/431, 8.13=-1109/1943,8-14=-2684/1670,14-16_ 1136/2094,6-14=-1261/1888 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vvlt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15h; 8=71f ; L=35ff; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and CC Extedor(2) -1-" to 2-6-0, Interior(1) 2-" to 17-6.0, Exterior(2) 17-64) to 21-" zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 pal bottom chord live load nonconcument with any other live loads. 5) ' This truss has been designed for a live load of 20.0ps1 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joints) 11 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 DO lb uplift at joint(s) except (jt=1b) 2=825, 11=825. Joaquin Velez PE No.68182 Isti USA, Inc. FL Cart 0634 6904 Parke East Blvd, Tampa FL 33619 Date: September 25,2018 Aj WARNWG-Vwffy OasfgnpxamHa REAONOTEBONI ANDINCLUDED1 KREFERANCEPAGEMMI4MM. lBea�ela BEFONE UBE. �� Design valid for use only with MBek® connectors This design Is based only upon parameters shown, and Is for an indMdual adding component, not a truss system, Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Additional temporary and permanernbrocing MiTek buNtlingdesign. Bracing Indicated istoprevent budding ofIndividual mussweb and/or chord members only Is always required for stability and to prevent collapse with possible personal Inlury and property damage. rprG neerral al� a regarding� ggpd Palle East Blvd. rr East B fabrication, storage, delivery, erection and bracing of tuares and tnus systems. seeANMMI Oualay CrbIB, Tampa, Sorely Inlomrnttunovallabie from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314,33610 Job Truss Truss Type City Ply MANOR 71 T1516BB70 M11439 BHA Hip Girder 7 1 - Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Tue Sep 25 08:37:07 2018 Page 1 IDIAJiomcsggFaOsPzA7N7xeHyeil l-17kW coOoB49kOUyGkdejX2N7n71RXRb5560hhEya8Vw 1330 22-9-0 r1-6pp -098-0 ],0 123�p 15-6.0 7" JJA;9 i21 25-60 26-0 31-b0 QUO-0I �11-6-0 I3-10. 230 31-2LEO 310.14 �d8-0 2-0-0 o-eo Scale = 1:64.8 TOP CHORD MUST BE BRACED BY END JACKS, 4.00 12 4x4 = ROOF DIAPHRAGM, OR PROPERLY CONNECTED PURLINS AS SPECIFIED. 12 46 14 47 16 NAILED NAILED NAILED 45 48 NAILED NAILED Sp�4XB axe 44 10 435 19 3x6 NAIL 49 21 NAILED =42 4 6 = 1B � ILE 2§0 4x8 9 NAIL 25 15 ILE 20 51 :1 41 52.. it2 r�Jlf 2 27?8' ,n1 Ir gl��f d 7 34 53 54 33 55 56 32 67 58 59 31 30 60 61 29 Special NAILED 7x8 = NAILED 3x5 = NAILED axe = NAILED 3x4 = _ 3x6 — 6xl0 =NAILED NAILED NAILED NAILED NAILED 20-0 0 3-00-09 70-0 ]-0.9 123-0 1]E-0 2230 2530 27-40 27-11,7 2 1 35-0.0 3-00-0q 3-0-2 0O H,Y 5-30 4-60 300 24-0 11­7 31319 0 0-9 Plate Offsets (X Y)-- [2:0-0-2 Edge] [3:0-2-4 0-2-0] [15:0-2-12 03-8] [26:0-7-4 0-2-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.98 Vert 0.29 33-34 >906 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT)-0.3233-34 >822 240 BCLL 0.0 Rep Stress lncr NO WB 0176 Horz(CT) 0.08 31 1 n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 215111 FT=20l. LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural woad sheathing directly applied or 3-6-10 oc Purim. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 "Except" 1 Row at midpt 3-9 20-31,26-29: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-7-1 oc bracing. WEBS 1 Row at midpt 9-32, 15-31, 26-31 JOINTS 1 Brace at Jt(s): 9, 15, 20,13 REACTIONS. All bearings 0-8-0. (lb) - Max Harz 2=-179(LC 6) Max Uplift All uplift 100111 or less atjoint(s) except 2=-1087(LC 8), 27=-279(LC 26), 31=-2164(LC 8), 29=-245(LC 8) Max Grav All reactions 250111 or less at joints) except 2=1443(LC 1), 27=323(LC 14), 31=311), 29=550(LC 30) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3649/2731, 3-4=-363/201, 4-8=-294/149, 8-10=-312/196, 10-12= 312/244, 12-14=-274/247, 3-5=-3015/2291, 5-7=-3016/2292, 7-9=-3016/2292, 9-11=-861/637, 11-13=-861/637,13-15=-861/637,15-17=-1507/2247, 17-18=-1507/2247, 18-20=-1507/2247,20-22=-1507/2247,22-24=-1507/2247, 24-26=-1513/2254, 14-16=-282/256, 16-19=-321/248, 19-21= 288/178,21-25=-296/145, 25-26=-322/143, 26-27=-4721701 BOT CHORD 2-34=-2481/3428, 33-34=-2435/3370, 32-33=-2184/3241, 31-32=-544/1121, 29-31=-593/476, 27-29=-599/492 WEBS 9-33=-142/449,9-32=-2348/1799,15-32=-756/1254,15-31=-3513/2423,20-31=-519/518, 3-34=470/647,26-29=-310/237,26-31=-1576/1233,3-33=114/270, 1 B-1 9=-323/320, 7-8=-352/336 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128ri TCDL=4.2psf; BCDL=3.Ops1; hie 15ft; B=71ft; L=35ft; eave=5h; Cat. It; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water Dancing. 5) All plates are 2x3 MT20 unless otherwise indicated. Joaquin Velez PE No.86182 6) Gable studs spaced at 2-0-0 Co. 7) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. MiTek USA, Inc. FL Cart 6634 8) "This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where A rectangle 3-6-0 tall by 2-0-0 wide 6904 Parke East Blvd. Tampa FL 33610 will fit between the bottom chord and any other members. Date: 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1087 Ib uplift at joint2, 279 Ib uplift at September 25,2018 joint 27, 2164 lb uplift at joint 31 and 245 Ib uplift at joint 29. Q WARNING -Vll Oeargn"remafareantl READ NOTES ON TNASAND/NCLUDED MITEKREFERANCE PAGE 14W7477 rev. lWOar2a15BEFORE USE. " Design valid for use only with Mliek® connectors. This design is based only upon parameters shown, and is for an indivitlual building component not a truss system, Before use, the building designer must verify the opplicablllly of design parameters and properly Incorporate this design Into the overall bulldingdesign Bracing indicated is to prevent buck) Ing of Individual truss web and/or chord members only, Addhonal temporary and permanent bracing LT Mllek Is always required for stability and to prevent collapse with possible personal Injury and property damage. FI 0enerol guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, sessANSVIPII Quail CIIN1Ior iN�e9 antl ICSI Sueaerp Component 6904 Perk, East Blvd. Salety Informational from Truss Plate Institute, 218 N. use Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss�Hp Qty Ply MANOR 71 M11439 BHA �Qdw� 1 1 T75168870 - Job Reference (oofon 11 - •-•••••-•- • •--••• ••• • -^ • •=••K• � 6. rda 9 P4an I Lald Ml l ea Industries, Inc. TUe Sep 25 08:37:07 2018 Page t NOTES- 0:AJiomosggFaOsPzA7N7xeHysi l l-t7kW wOoB7gkOUyGkdejX2N4nl l RXRb5560hhEya8Vw 11) "NAILED" indicates 3-10d (0.148°x3') or 3-12d (0.148"0.25") toe -nails per NDS guidlines. 12) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated IDRd(s) 242 Ito down and 328 lb up at 7-0-0 on top chord, and 402 lb down and 504 lb up at 7-0-0 on bottom chord. The design/selection of such connection device(s) i5 the responsibility of others. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or b@ck (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3= 54, 3-14=-54, 14-26= 54, 26-28=-54, 35-38=-20 Concentrated Loads (Ib) Vert :34=-402(F)41=-146(F)42=-111(F)43=-111(F)44=-111(F)45=-111(F)46=-111(F)47— 111(F) 48= 111(F) 49— 111(F)50=111(F)51=-111(F) 52=-111(F) 53=-68(F) 54=-68(F) 55=-68(F) 56=-68(F) 57=-68(F) 58=-68(F) 59=-68(F) 60=-68(F) 61=-68(F) O WARNING- Verlfydealgn perametanend READ NOTES ON THMANOWCLUDEDMR KREFERANCEPAGEMx7478-- 112113cs)ISDISFORE USE. Design valid for use only with Ni connectors, This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system, Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into me overall building tlesign. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stoollify and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrlcol storage, delivery, erection and bracing of trusses and truss systems, seeANN/Rli Quality CrIll III and BCBI III Component 6904 Parke East Blvd. Sal tnfonnationavallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314, Tampa, FL 33610 Job T11es Truss Type Qty Ply MANOR71 T15168871 M11439 GRB HIP GIRDER 1 i Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL - d.r3u a Mar ii zuld Will Industries, Ind. Tue Sep za 06.37.09 2018 Rdgd Ib;A�iomcsggFaOsPzA?N?xeHyeil l-pW sH1 US2icPSGo6fr2gBcTSLVrM171NOZQVn17ya8Vu 1-0- 3-00-14 7-0-0 10-4 0 13.8.0 18-5-15 23-2-1 48-3 28.0.0 4.9.15 314.2 35-0 3-1-2 3-10d4 1-0.0 1-0- 3d0-14 3-1-& 3.4-0 3.4-0 49-15 Scale = 1:60.3 NAILED Sz12 Ml EHS-_ NAILED NAILED NAILED NAILED NAILED Special 4.00 12 Spacial NAILED NAILED 2.3 11 axe = 3x8 = NAILED 30= NAILED US = 3 23 24 25426 27 5 28 296 30 31 32 7 33 34 8 IIII 9 101�+w 2 a 4� no Jill m1 '1 d d 18 35 36 15 37 14 38 39 4013 41 42 12. 43 44 3x4 = 2x3 1 NAILED 3z8 = Sz12 = NAILED 3x9 - 5z8 MTIBHS = NAILED Eel4x5 = Special NAILED NAILED NAILED NAILED N AILED NAILED NAILED Special LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TPI2014 CSI. TC 0.90 BC 0.98 W B 0.93 Matrix -MS DEFL. in (lac) 1/defl L/d Vert(LL)-0.3411-13 >751 360 Vert(CT) -0.7611-13 1339 240 Hors(CT) 0.08 9 n/a n/a Wind(LL) 0.3711-13 >696 240 PLATES MIT20 MT18HS Weight: 155 to GRIP 244/190 244/190 FT=20% LUMBER- BRACING - TOP CHORD Structural wood sheathing directly applied or 3-6-8 oc purlins. TOP CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-9-2 do bracing. BOT CHORD 2x4 SP M 30 WEBS 1 Row at micipt. 6-14, 3-14 WEBS 2x4 SP No.3'Except' 4-14: 2x6 SP No.2 REACTIONS. (lb/size) 2=504/0-8-0, 14=3752/0-8-0, 9=1326/0-8-0 Max Harz 2=78(LC 7) Max Uplift 2=-652(LC 8), 14=-2840(LC 8), 9=-1012(LC 8) Max Grav 2=513(LC 17), 14=3752(LC 1), 9=1327(LC 18) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3_ 778/990, 3-4=-1513/2146, 4-6=-1513/2146, 6-7- 1267/775, 7-8=-3171/2427, 8-9=.3362/2486 BOT CHORD 2-16=-836/704, 14-16=-876/744, 13-14=-612/1267, 11-13=-1937/2770, 9-11=2245/3137 WEBS 3-16=-646/742,4-14=-772/685, 6-14=-3794/2549, 6-13= 671/1191'7-13= 1685/1485, 7-11=-370/570, 8-11=-323/635, 3-14=-3037/2708 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opst; hl SIT; 3=71 ft; L=35ft; eave=5ft; Cat. II; Exlo C; Encl., GCpi=0.18; MI (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tal I by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 652 lb uplift at joint 2, 2840 Ib uplift at joint 14 and 1012 lb uplift at joint 9. 8) NAILED" indicates 3-1 bid (0.148"x3") or 3-12d (0. 1 48"x3.25") toe -nails per NDS guidlines. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 193 lb down and 316 Ip up at 7-0-0, and 193 Ib down and 316 lb up at 28-0-0 on top chord, and 402 lb down and 419111 up at 7-0-0, and 402 Ile down and 504 lb up at 27-114 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CAB E(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=54, 3-8=-54, 8-10=-54, 17-20= 20 Joaquin Velez PE N0.66162 MIT& USA, Inc. FL Cart 6634 8904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 ,&WARNING-V", esign pawmerersand READ NOTES ON TNIS AND MICLUDED MITEKREFEShownP and ISM BEFORE USE Design vend far use only with MITek®connectors. Tnis design Is based only upon parameters shown, and Is f6F an Individual binding component, not MR a truss System, Before use, the building designer mustvetlfy the applicability of design parameters and prosiI Incorporate this design Into the overall building tleslgn. Bracing indicated is to prevent buckling of Individual truss web and/or chord members all AddlHonaltempomry and permanent bracing MiTeK the Is always required for docility and to prevent collapse with possible personal injury an tl property damage. r®rD99.99 aeneral nd !CA M16, pence Cesg Component 6904 Parke East BNtl. fabrication, storage, delivery,.,action and bracing of trusses and truss systems, seeANSVIPII Gopl1MyCigar& Tampa, FL 33610 Solely minmwt ancvallabie from Truss Plate Institute. 218 N. Lee Sheet, Suite 312, Afexandrlo, VA 22314, I Truss Truss Type 1439 GRB HIP GIRDER 130a Mar 11 T15168871 LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 3=146(B) 8=146(B) 16=-402(B) 11=-402(B)23=-111(B)24=-111(B)25=-111(B)97 -111(B)28=-111(B)29=-111(B) 3111(B)32=-111(B) 33=-111(B) 34=-111(B) 35=-68(B) 36=-68(B) 37=-68(B) 38=-68(B) 39=-68(B) 40=-68(B) 41=-68(6) 42=-68(B)43=-68(B) 44=-68(B) ,&WARNING-VarifydaelgnRare.hn,.d READ NOTES ON THIS AND INCLUDEDMTTEKREFERANCEFAGEMIFN79 rev.10a 13 BEFORE USE. Design valid for use only with MReI� connectors, this tleslgn is based only upon parameters shown, and Is fbF an Intllvitlual building component, not a truss system. Before use, the bulltling designer must verify the appllcablllN of design parameters an' prop9Hy ncorpomte this tlesign Into the overall bulltling tlesign, eracing Intllcofed Is to prevent buckling of Individual truss web and/or chortl members only Additional temporary and permanent bracing Mirek' bulld srequlretl for"g"" and to prevent coliop. with possible personal lnfury ontl property tlamoge. F®F general gultlonce regartling}he g904 PaBa Eest BN1. fabrication storage, delivery, erection and oradng of pusses and huss systems, seeANSU1F11 CaallSryy CM�rIBr QE!-!g antl BIItlSlp ColnponrrM Tempe, FL 38610 Sabb Inbmrotbnavallable from Truss Plate Institute, 218 N, Lee Street, Suite 312, Alexandria. VA 22314. Job Truss Truss Type Qty Ply MANOR 71 T15168872 M11439 J1 JACK -OPEN 8 1 Job Reference ional Chambers Truss, Inc., Foil Pierce, FL 0.130 s mar 11 eu1 a Mr I an industries, Inc. rue Sep ea 06:37:09 2u16 rage 1 ID;AdiomcsggFaOsPzA?N?nHysil l-pWsH1 US2icPSGo6fr2gBcTSXnrbH?WtOZOVd7ya8Vu -1-D0 1-D-0 1.0.0 1-&o 3x4 = LOADING (I SPACING 2-0-0 CSI. DEFL. In floc) Udell Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Ven(LL) -0.00 5 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 240 BCLL 0.0 ' Rep Stress [nor YES WB 0.00 HOrz(CT) 0.00 4 file n/a BCDL 10.0 Coda FBC2017trP12014 Matdx-MP Wind(LL) -0.00 5 >999 240 LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP I REACTIONS. (Ib/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical Max Horz 2=48(LC 12) Max Uplift 3=4(LC 9), 2=-140(LC 12) Max Grav 3=10(LC 17), 2=118(1-C 1), 4=17(LC 12) FORCES. (Ib) - Max. Camp./Max. Ten. - All forces 250 (Ib) or less except when shown. Stale =1:6.1 PLATES GRIP MT20 2441190 Weight: 5lb FT=20% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.OpsC h=15ft; B=71ft; L=35ft; eave=5ft; Cat. II; Exp CI Encl., GCpi=0.18; MW FRS (directional) and C-C Extedor(2) zone; porch left and right exposed;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrem with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 1401b uplift at joint 2. Joaquin Velez PE No.66182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 32610 Date: September 25,2018 Q WARNNG-yM/yWslgnpvanrerenandIE40 MOM ONTN6 AND MCLUDED WEKREFERANCEPA0E 61174MMv. laUYlmagEFOREUSE. ��- Design vatil for We only with IVI Connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system, Before use, the buIlding designer must verity the appicablllTy of design parameters and proppedy Incorporate this design Into me overall bullding design. Bracing indicated Is to prevent buckling Of Individual trunweb and/or chord members aRIV Additional temporary and permanent bracing MiTek is always required for stability and M paved cdlopse with possible personal Ir1k1ry and propeM damage I'or �e'v regarding the6904 Parke East Blvd. fabricalim sforage, delNery, erection and bracing of fusses and truss Walema. seeANU Wl1 py�y CialIP, Tampa, FL W610 lately Informafi w 'liable from Truss Plata Institute. 218 N, Lee Street Sure 312, Alexandria, VA 22314, Job Truss Trues Type QIY Ply MANOR 71 T15168873 M11439 J3 JACK -OPEN 8 1 Job Reference o tonal e nne. i i oma nnlTaL Ind,mfee. Inc Tca San 96 ne:37:10 2018 Pace 1 Chambers I runs, Inc., Fort metes,I 3x4 — I®{AJiomosggFaOsPzA?N?xeHyei l l-HiOfFgSgTwXJtyhrPmB09h?goFt7kz7Xo3FLIZyaBVI Ib Scale = 1:9A LOADING (psf) SPACING- 2-0-0 CSI. TO 0.29 DEFL. in (loc) III III Vert(LL) 0.02 4-7 >999 240 PLATES GRIP MT20 244/190 TOLL 20.0 Plate Grip DOL 1.25 Lumber DOL 1.25 BC 0.30 Ved(CiT) .0.01 4-7 >999 240 TCDL 7.0 BCLL 0.0 ' Rep Stress Incr YES WE 0.00 Horz(CT) -0.00 3 n/a n/a Weight: 11 Ib FT =20% BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER- BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. TOP CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=63/Mechanical, 2=172/0-8-0, 4=36/Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-67(LC 12), 2=-207(LC 12), 4=-51(LC 12) Max Grav 3=63(LC 1), 2=172(LC 1), 4=50(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.21)sf; BCDL=3.Opsf; hF1511; B=7111; L=35ft; save=5ft; Cat. 11; Exp C; Encl., GCpi=0.181 MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-4 zone; porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0fai on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will tit between the bottom chord and any other members. 4) Refer to girders) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 67 lb uplift at joint 3, 2071b uplift at joint 2 and 51 lb uplift at joint 4. Joaquin Velez PE No.88182 MiTek USA, Inc. FL Cart 8834 6904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 WARNING. verHydeslgn parametms and READ NOTES ON THISAND INCLUDED MmEKREFERANCE PAGEheiii rev. iN5a2e15aEFOREUSE. elgn valid for use only wIM Miiekle connectors, Tnls design Is based only upon parameters shown, and starch Individual building component, not IllllME runs system, Before use, the building designer must verify fine applicability of design parameters and pror3®Ily Incorporate this design Into Me overall Ilding design. Bracing Intlicoted Is to prevent buckling of Individual truss web and/or chord members only Additional temporary and permanent bracing MiTek` )II requlretl for stabllify and to prevent collapse with possible personal Injury and property damage. Fgf general guidance regarding fine e904 Parke East Blvd. .e +i, a+,.,.. nelmemerection antl directed of trusses and truss systems, seeANSVIPII Cuallly CMaABr paea9 and 11031 WIdInO ComponentTampa, FL 33610 Job Truss Truss Type 71T15168874 M11439 JS 7Qt­y JACK -OPEN 7PIM.ANOR Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 30 = 8.130 s Mar 11 2018 MiTek Industries, Inc. Tue Sep 25 08:37:11 2018 Page t ID:AJlomcsggFaOsPzA?N?XeHyeill-Iv_1SATIEDfAVeGlzTitiuxgzeC_TQNgOj_ugOya8Vs Scale = 1:12.7 Ib - I LOADING lost) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defy Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.32 Vert(LL} 0.11 4-7 >522: 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.32 Vert(CT) -0.05 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES W B 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 17 lb FT=20% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=115/Mechanical, 2=242/0-8-0, 4=63/Mechanical Max Hoe 2=123(LC 12) Max Uplift 3=-122(LC 12), 2= 278(LC 12), 4=-92(LC 12) Max Gram 3=115(LC 1), 2=242(LC 1), 4=87(LC 3) FORCES. (Ib) - Max. Comp./Max. Ten. -All tomes 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15tt; B=71tt; L=35R; eave=51t; Cat. 11; Exp C; Encl., GCpi=0.1& MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-4 zone; porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint 3, 278 lb uplift at joint 2 and 92 lb uplift at joint 4. Joaquin Velez PE Ni II USA, Inc. FL Cad 6634 6904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 QWARNING- Verrrydesignpmemerercana READ NOTES ON MMANDWCLUDEDMm KREFERANCEPAGEMIFll7arev. 14MOISBEFORE USE. Design valid for use only with MIiconnectors. This design Is based only upon parameters shown, and Is fdf on individual building component, not �� a truss system. Before use, the building designer must verify the applicability of design parameters and propefly Incorporate this design Into the overall Adoi6onal temporary and permanent bracing WOW building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only Is always required for stability and to prevent collopse with possible personal injury and property damage. Fbf general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANM/IPII Qual Creedal, Pill and SCSI SolComponent Informallorrovailable from Truss Plate Institute, 218 N, Lee Street, Suite 312. Alexandria, VA 22314, 6904 Parke East Blvd.Safely Tempe, FL 33610 1439 IJ7 (JACK -OPEN 124 1 1 I T15168875 Scale: 314-.1' 3x4 - LOADING (part SPACING- 2-0.0 CSL DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Ved(LL) -0.09 4-7 >976 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 vert(CT) -0.18 4-7 >451 240 BCLL 0.0 Rep Stress Inor YES We 0.00 Hon(CT) -0.00 3 n/a We BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Wind(LL) 0.17 4-7 >497 240 Weight: 231b FT=20% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=165/Mwhanical, 2=315/0-8-0, 4=88tMmhanical Max Hom 2=161(112) Max Uplift 3=-152(LC 12), 2=-210(LC 12), 4=-12(LC 12) Max Gmv 3=165(LC 1), 2=315(LC 1), 4=124(LC 3) FORCES. (II -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural mod sheathing directly applied or 6-0-0 oc pur ins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vu11=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psY 11=1511; B=71ft; L=35ft; eave=5ft; Cat. II; Exio C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interlor(1) 2-6-0 to 6-11-4 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcumem with any other live loads. 3) ` This truss has been designed for a live load of 20.0ps1 on the bottom chord In all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 152 Ib uplift at joint 3, 210 Ib uplift at joint 2 and 12 lb uplift at joint 4. Joaquin Velez PE No.e8182 III USA, Inc. FL Can 6634 8604 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 WARNING -Vmfty dearer pammefen end READ NOTES MIS AND WLUDED NREN REFEIUINCE PAGE All nv. 100, 1015 BEFORE USE sign volltl for use only with v r ekS connectors. This design is based only upon parameters shown, and Is far an Indlvldud bullding component not ruse system. Before use, the "din designer must verify the applical of design parameters and proherly Incorpora}e this tleslgn Into the overall acting deign. Bracing astlkafedato prevent bucklap of trrtlMtlual hue web antl/or ctwrd member oP,Ik,. Addlfi l temporary and permanent roacln0 MiTek' sways required for atoblllly antl to prevent collapse vMh Iwss�le personal ...ury and prapeny tlamoge or generd guldonce regarding the ,ricoflpn, storage, dellvery, erection and bracing of t, psaes and trues seyi; ams, seoeAIIII II OuoXl� Creell8. DSH9 aM %N Mtlh7 ComplaReid Tampa, FLrks East Blvd. .. Tampa, FL 33610 =Job OR 71 T15168876 eference (options]) 8.130 s Mar 11 2018 Mil Industries, Inc. Tue Sep 25 08:37:12 2018 Page 1 ID:AII@IpcsggFaOsPzA?N?xeHyeil l-D5YPtWUw?Xnl7GrEXADuE64lv2YrCnRgFNkRMSyaBVr Job Truss Truss Type Ml 1439 KJ7 DIAGONAL HIP GIRDER Chambers Truss, Inc., Fort Pierce, FL Scale = 1:21.2 314 — NAILED NAILED NAILED 5.6.11 4-3-6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) 0.09 6-7 >999 240 MT20 244/190 TOOL 7.0 Lumber DOL 1.25 BC 0.28 Vert(CT) -0.06 7-10 >999 240 BCLL 0.0 * Rep Stress ]net NO W B 0.40 Hom(CT) -0.02 5 n/a Na BCDL 10.0 Code FBC2017/TPI2014 Matrill Weight: 39 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 Be No.3 REACTIONS. (Ib/size) 4=111/Mechanical, 2=501/0-10-15, 5=362/Mechanical Max Horz 2=161(LC21) Max Uplift 4=-117(LC 8), 2=-574(LC 8), 5=-443(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1031/1087 BOT CHORD 2-7=-1148/990, 6-7=-1148/990 WEBS 3.7= 2981284, 3-6=-1044/1211 Structural wood sheathing directly applied or 6-0-0 oc purllns. Rigid ceiling directly applied or 6-7-6 oc bracing. NOTES- 1) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; hint Sit; 13=71 ft; L=35ff; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonccncurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 117 lb uplift at joint 4, 574 Ile uplift at joint 2 and 443 Ito uplift at joint 5. 6) "NAILED" indicates 3-1 Od (0.148"x3") or 242d (0.14B'x3.25") toe -nails per NOS guidlines. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead +Root Live (balanced): Lumber Increase=1.25, Plate Increase=1,25 Uniform Loads (plf) Vert: 1-4=-54, 5-8=-20 Concentrated Loads (lb) Vert: 11=-3(F=-1, B= 1) 12=-76(F=-38, B=-38) 13=-7(F=-3, B=-3) 14=-20(F=-10, B=-10) 15=-69(F=-34, B=34) Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: September 25,2018 O WARNfill Verlrydnf9n,iv dmieraend READ NOTES ON MISANDWCLUDEDMRKREFERANCEPAGEM&MYOMe faM OISBEFORE USE. Design valltl for use only with MPeM connectors, Th; design is bond only upon parameters shown, and is for on individual colliding component, not a truss system, Before use, the building designer must verify the appllcabiI of design parameters and properly lincorrecraide this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing for to with Injury and Property damage For general guidance regarding the MiTek' Is always required stabilly and prevent collapse possible personal fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANW1911 CuaBS Criteria, 03149 and 6CS ladding Component 69N Parke Ent Blvd. Tampa, FL 33610 EaleN Inbnna6omvalloble from Truss Plate InstltWe, 218 N. Lee Street, Suite 312, Alexandria, VA 2231A. Symbols PLATE LOCATION AND ORIENTATION I'll13 74 Center plate on joint unless x y it offsets are indicated. Dimensions are In ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. For 4 x 2 orientation, locate plates 0-1/0 from outside edge of truss. This symbol Indicates the required direction of slots in connector plates. Plate location details available in MiTek20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text In the bracing section of the output. Use T or I bracing If indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown Is for crushing only. Industry Standards ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 648 I I dimensions shown in sixteenths (Drawings not to scale) 2 3 TOP CHORDS 0 c O U U a O JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSAETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. 2012 MITek® All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev, 10/03/2015 A General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1, Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI, 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered, 3. Never exceed the design loading shown and never stack materials on Inadequately braced trusses, 4, Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at Joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19%at time of fabrication. 9, Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10, Camber is a non-structural consideration and Is the responsibility of truss fabricator General practice Is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions Indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing Indicated on design. 14, Bottom chords require lateral bracing at 10 ft. spacing, or less, If no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless Indicated otherwise 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19, Review all portions of this design (front, back, words and pictures) before use, Reviewing pictures alone is not sufficient, 20, Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.