HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENT�INITY ER®
EVALUATION RER
Soprema, Inc.
1640 rue Haggerty
Drummondville, Quebec32C SP8 Canada
(819)478-2400
SCANNE(
BY
St Lucie County
NOV 21 2018
ST. Lucie Countyj Pi-tmivt1r1
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET. UNIT #13
OXFORD, CT 06478
(203) 262-9245
Lion Report S18010.06.09-R11
FL2569-R13
Date of Issuance: 06/15/2009
Revision 11.10/06/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6 h Edition (WJ F�-"dfA"Y ding Codgl-FACHMEW
sections noted herein. FILE COPY ARETHEREST Y THE
DESCRIPTION: Soprema Roof Underlayment5 0^^trrrRA(;"f 6t+ C;++;LGORD
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity[ ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity( ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8
Prepared by:
O ATTACHMENTS
THE RESPONSIBILITY OF THE
,C-
TOR OR RECORD
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida OCA ANE1983
THESE PLANS AUBECT O AY ALL PROPOSED
REQUIRED BY FIELD INSPECTORS THAT
PRAY BErNKgTHSAAL AAPN U ABLE CODES.
The rao:imile seal appearing vras authorized by Robert
Nieminen, V.E. on 10106/2017. This does not serve as an
eksononiraby signed document.
CERTIFICATION OF INOEPENOMa:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity[ ERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ST. LUCIE COUNTY 8t1fLDtNG l
REVIEWED FOR COMPLIANCE`
DATEMUSTEMTJOB
SITE OR NOINSPECTION( BE K PT MADE
ROOFING COMPONENT EVALUATION:
QOTRINITYIERD
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 6u' Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, T1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
Ealfty
Examination
Reference
Date
ERD (TST6049)
ASTM D1970 / TAS 110
2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 / TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-RI
04/18/2007
ERD (TST6049)
TAS 103 / TAS 110
57120.11.07-2
11/02/2007
ERD (TST6049)
ASTM D1970 / TAS 110
S13190.02.09-R1
04/01/2010
ERD (TST6049)
ASTM D1970/TAS 110
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.10-R3
09/09/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM 01970
537210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties/Tensile Adhesion
S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties/ Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.14
04/17/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-D (CER1592)
HVHZ Compliance
15-0508.04
09/24/2015
ICC-ES(EVL2396)
20151BC Compliance
ESR-1524
03/01/2017
PIN(TST5878)
Physical Properties
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch; meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970.
4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment; meets ASTM D1970.
Exterior Research and Design, U.C. Evaluation Report 518010.06.09-1111
001iraor ofAuthorikothm#9503 6" EDITION (2017)FBC NON-HVH2 EVALUATION F1.2569-1113
Soprema, Inc. Revision 11: 10/06/2017
Page 2 of 8
TRINITYERd
4.5 Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, S85 modified bitumen roof
underlayment available in two widths; 36 and 45 inch; meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self -adhering, woven polyethylene surfaced, high temperature, SOS modified
bitumen roof underlayment; meets ASTM D1970.
4.7 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof
underlayment; meets ASTM 01970.
4.8 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified
bitumen roof underlayment; meets ASTM D1970.
4.9 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof
nderlayment; meets ASTM D1970.
9-107
Smooth Seal HT isa self -adhering,.. glass -mat reinforced, film -surfaced, SOS modified bitumen„oof underlayment; meets ASTM D197D_
4.11 RESISTO L81236 is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof
underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.12 Primesource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SOS
modified bitumen roof underlayment, with a 364nch sheet width; meets ASTM D1970.
4.13 RESISTO L81244 is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof
underlayment, with a 44-inch sheet width; meets ASTM D1970.
4.14 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SOS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
.TABLE I' RotHFOVEB OPTIONS
Underlayment
Asphalt
Nail -On
Foam -On
Metal
Wood Shakes &
Slate
Shingles
Tile
Tile
Shingles
Lastobond TU HT
Yes
Yes
Yes
...Yes
Yes
Yes:_
See 5.5.1-:
Lastobond Shield / Pro HT-N / RESISTO SA
c
SMOOTH PLY 40
Yes
No
o`
Yes
Yes:
Lastobond Shield HT/Pro HT-5
Yes
Yes
Yes
Yes
Lastobond Eaves Protection Sheet
Yes
`,I Nki.
r
t' No
Yes
Yes
Lastobond 195
a
°�
Lastobond ECO / RESISTO LB1236, Grip-
Rite Eave & Valley Protector/ RESISTO
Yes
a;
v�m ''�
NO`wr�:
Yes
Yes<
Exterior Research and Design, I.I.C. Evaluation Report 518010.06.09-R31
Gartiftcate ofAudwrwfioa a99a3 en EDITION (2017)FBC NON-HVH2 6VALUATION FL2569-R13
Soprema, Inc. Revision 11: 10/06/2017
Page 3 of 8
("C'
TRINITY ERD
5.5.1 "Foam -On Tile" is limited to use of following Approved the adhesives / underlayment combinations.
`, TABLE 1A-ALLOWMAX MILE ADHIMOE/-LINDERU%yNlENT COMMNATIONS1
Adhesive
Florida Product Approval Underlayments
Dow TileBond'"
FL22525 Lastobond TU HT
ICP Adhesives Polyset° AH-160
FL6332 Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
L81236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to
installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR
GR applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or 1.11.1807.
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overtuming Moment Resistance Performance.
Exterior Research and Design, LLG Evaluation Report S18010.06.09-R71
Certificate ofAuWmo Von p95a3 6TeEDITION (20171 FBC NON-HVHZ EVALUATION FL2569-RI3
Soprema, Inc Revision 11: 10/06/2017
Page 4 of 8
5.6.3
5.6.4
TRINITY } ERD
Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-5, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12).
Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2022 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TR1 April 2012 (04-12) and are used in foam -on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind
pressures.
#1 Maximum Design Pressure = -45.0 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#2 Maximum Design Pressure = -67 5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600c
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#3 Maximum Design Pressure = -150 0 Dsf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or
weighted roller to ensure there are no voids, and ensure there are no voids/bridging at
side and end -laps.
#4 Maximum Design Pressure =-60 0 psi:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered
5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a
Maximum Design Pressure of -45 psf.
Exterior Research and Design, U.C. Evaluation Report S18010.06.09-R11
ceroicote ofAud rkadan#9503 6r"EDITION(2017)FBC NON-HVH2 EVALUATION FL2569-R13
Soprema, Inc. Revision 11: 10/06/2017
Page 5 of 8
TRINITY; ERD
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk' carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-
days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FIR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
_- - TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcf-DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 30-tile stack
5:12
Max. 30-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
Lastobond TU HT
,
Lugged
Max. ID -tile stack 5:12
Colphene FR GR
Flat
Lugged
Max. 10-tile stack
6:12
Exterior Research and Design, LLC. Evatuation Report 519010.06.09•Rll
Certificate OfAutlrodro0on p9503 e EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R13
Soprema, Inc. Revision 11: 10/06/2017
Page 6 of 8
4
TRINITY; ERD
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER (if applicable).
L6�� Las#okond.TU HT; Lasto6orid Sh)eid, l.asto6ond Pro HT-IY, RESISTFi �h SItA(#4TN PLY #0, "Lasttflwnd 5hieli%
lid, lastobdnd Pro H7=$, iastp§ond i aVe5 Protec�tarJ ;Sheet LastobF+ryd 1�$,;Ca'stropd Eco, 4astAiid:
Smao2lr 50aii NT,151'i>Li}J�Z36, Grip Rite EavQ & Ya(teir Pr�atec�ar,#5'fO �.B1z44 or Ctjt�henb Pit GIB-'
..1 Shall be installed in compliance with the requirements for ASTM D1970 underiavmpnr in FRr Tnhln
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 60Gc or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roil out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Lastobond TU HT or ColQhene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table i herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and Soprema published requirements for tile staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Exterior Research and Design, U.C. Evaluation Report S38010.06.09-R11
Ca'Wirare OfAurhonzatian 9950.3 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL2569-R13
Soprema, Inc. Revision 11: 10/06/2017
Page 7 of 8
/
TRINITYERD
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties sppcifications.
Plant
ifitati
Rincu-ci s
Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Drummondville,
Lastobond Pro HT-N, Lastobond Pro HT-S, Lastobond 195, Lastobond
QC (Canada)
ASTM D7970
Eaves Protection Sheet Lastobond Eco, Lastobond Smooth Seal HT,
RESISTO LB1236, PrimeSource Grip-RRe Eave & Valley Protector,
RESISTO L81244
ASTM D1970 & FRSA/TRI 04-12
Colphene FR GR
Wadsworth, OH
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO L81244
ASTM D1970 & FRSA/TRI D4-12
Lastobond TU HT; Colphene FR GR
Gulfport, MS
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave &Valley Protector, RESISTO L81244
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Deskn, U.C. Evaluatbn Report S18030.06.09-R11
Catyl�are ojauMoMmtlan a9503 6rxEDITION(2017)FBC NON-HVHZ EVALUATION FVS69-R13
Soprema, Inc Revision 11: 10/06/2017
Page 9 of 8