Loading...
HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENT�INITY ER® EVALUATION RER Soprema, Inc. 1640 rue Haggerty Drummondville, Quebec32C SP8 Canada (819)478-2400 SCANNE( BY St Lucie County NOV 21 2018 ST. Lucie Countyj Pi-tmivt1r1 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET. UNIT #13 OXFORD, CT 06478 (203) 262-9245 Lion Report S18010.06.09-R11 FL2569-R13 Date of Issuance: 06/15/2009 Revision 11.10/06/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6 h Edition (WJ F�-"dfA"Y ding Codgl-FACHMEW sections noted herein. FILE COPY ARETHEREST Y THE DESCRIPTION: Soprema Roof Underlayment5 0^^trrrRA(;"f 6t+ C;++;LGORD LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity[ ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity( ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8 Prepared by: O ATTACHMENTS THE RESPONSIBILITY OF THE ,C- TOR OR RECORD Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida OCA ANE1983 THESE PLANS AUBECT O AY ALL PROPOSED REQUIRED BY FIELD INSPECTORS THAT PRAY BErNKgTHSAAL AAPN U ABLE CODES. The rao:imile seal appearing vras authorized by Robert Nieminen, V.E. on 10106/2017. This does not serve as an eksononiraby signed document. CERTIFICATION OF INOEPENOMa: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity[ ERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ST. LUCIE COUNTY 8t1fLDtNG l REVIEWED FOR COMPLIANCE` DATEMUSTEMTJOB SITE OR NOINSPECTION( BE K PT MADE ROOFING COMPONENT EVALUATION: QOTRINITYIERD 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6u' Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012 (04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Ealfty Examination Reference Date ERD (TST6049) ASTM D1970 / TAS 110 2968.05.04-2 05/14/2004 ERD (TST6049) Physical Properties 2757.02.05 02/03/2005 ERD (TST6049) ASTM D1970 / TAS 110 2974.03.05-2 05/17/2005 ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) Wind Resistance 2779.11.05-RI 04/18/2007 ERD (TST6049) TAS 103 / TAS 110 57120.11.07-2 11/02/2007 ERD (TST6049) ASTM D1970 / TAS 110 S13190.02.09-R1 04/01/2010 ERD (TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 04/07/2010 ERD (TST6049) Physical Properties / Tensile Adhesion S11150.05.10-R3 09/09/2010 ERD (TST6049) Physical Properties / Tensile Adhesion S11150.05.09-R2 10/05/2010 ERD (TST6049) ASTM 01970 537210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014 ERD (TST6049) Physical Properties/ Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017 M-D (CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 20151BC Compliance ESR-1524 03/01/2017 PIN(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970. 4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. Exterior Research and Design, U.C. Evaluation Report 518010.06.09-1111 001iraor ofAuthorikothm#9503 6" EDITION (2017)FBC NON-HVH2 EVALUATION F1.2569-1113 Soprema, Inc. Revision 11: 10/06/2017 Page 2 of 8 TRINITYERd 4.5 Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, S85 modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.6 Lastobond Pro HT-S is a self -adhering, woven polyethylene surfaced, high temperature, SOS modified bitumen roof underlayment; meets ASTM D1970. 4.7 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof underlayment; meets ASTM 01970. 4.8 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof underlayment; meets ASTM D1970. 4.9 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof nderlayment; meets ASTM D1970. 9-107 Smooth Seal HT isa self -adhering,.. glass -mat reinforced, film -surfaced, SOS modified bitumen„oof underlayment; meets ASTM D197D_ 4.11 RESISTO L81236 is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.12 Primesource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof underlayment, with a 364nch sheet width; meets ASTM D1970. 4.13 RESISTO L81244 is a self -adhering, glass -mat reinforced, sand -surfaced, SOS modified bitumen roof underlayment, with a 44-inch sheet width; meets ASTM D1970. 4.14 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SOS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: .TABLE I' RotHFOVEB OPTIONS Underlayment Asphalt Nail -On Foam -On Metal Wood Shakes & Slate Shingles Tile Tile Shingles Lastobond TU HT Yes Yes Yes ...Yes Yes Yes:_ See 5.5.1-: Lastobond Shield / Pro HT-N / RESISTO SA c SMOOTH PLY 40 Yes No o` Yes Yes: Lastobond Shield HT/Pro HT-5 Yes Yes Yes Yes Lastobond Eaves Protection Sheet Yes `,I Nki. r t' No Yes Yes Lastobond 195 a °� Lastobond ECO / RESISTO LB1236, Grip- Rite Eave & Valley Protector/ RESISTO Yes a; v�m ''� NO`wr�: Yes Yes< Exterior Research and Design, I.I.C. Evaluation Report 518010.06.09-R31 Gartiftcate ofAudwrwfioa a99a3 en EDITION (2017)FBC NON-HVH2 6VALUATION FL2569-R13 Soprema, Inc. Revision 11: 10/06/2017 Page 3 of 8 ("C' TRINITY ERD 5.5.1 "Foam -On Tile" is limited to use of following Approved the adhesives / underlayment combinations. `, TABLE 1A-ALLOWMAX MILE ADHIMOE/-LINDERU%yNlENT COMMNATIONS1 Adhesive Florida Product Approval Underlayments Dow TileBond'" FL22525 Lastobond TU HT ICP Adhesives Polyset° AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO L81236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or 1.11.1807. ' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overtuming Moment Resistance Performance. Exterior Research and Design, LLG Evaluation Report S18010.06.09-R71 Certificate ofAuWmo Von p95a3 6TeEDITION (20171 FBC NON-HVHZ EVALUATION FL2569-RI3 Soprema, Inc Revision 11: 10/06/2017 Page 4 of 8 5.6.3 5.6.4 TRINITY } ERD Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-5, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12). Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2022 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TR1 April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered. #2 Maximum Design Pressure = -67 5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol600c Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered. #3 Maximum Design Pressure = -150 0 Dsf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. #4 Maximum Design Pressure =-60 0 psi: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered 5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. Exterior Research and Design, U.C. Evaluation Report S18010.06.09-R11 ceroicote ofAud rkadan#9503 6r"EDITION(2017)FBC NON-HVH2 EVALUATION FL2569-R13 Soprema, Inc. Revision 11: 10/06/2017 Page 5 of 8 TRINITY; ERD 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30- days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FIR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. _- - TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcf-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 30-tile stack 5:12 Max. 30-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Lastobond TU HT , Lugged Max. ID -tile stack 5:12 Colphene FR GR Flat Lugged Max. 10-tile stack 6:12 Exterior Research and Design, LLC. Evatuation Report 519010.06.09•Rll Certificate OfAutlrodro0on p9503 e EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R13 Soprema, Inc. Revision 11: 10/06/2017 Page 6 of 8 4 TRINITY; ERD 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable). L6�� Las#okond.TU HT; Lasto6orid Sh)eid, l.asto6ond Pro HT-IY, RESISTFi �h SItA(#4TN PLY #0, "Lasttflwnd 5hieli% lid, lastobdnd Pro H7=$, iastp§ond i aVe5 Protec�tarJ ;Sheet LastobF+ryd 1�$,;Ca'stropd Eco, 4astAiid: Smao2lr 50aii NT,151'i>Li}J�Z36, Grip Rite EavQ & Ya(teir Pr�atec�ar,#5'fO �.B1z44 or Ctjt�henb Pit GIB-' ..1 Shall be installed in compliance with the requirements for ASTM D1970 underiavmpnr in FRr Tnhln 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications: While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 60Gc or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roil out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Lastobond TU HT or ColQhene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table i herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and Soprema published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Exterior Research and Design, U.C. Evaluation Report S38010.06.09-R11 Ca'Wirare OfAurhonzatian 9950.3 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema, Inc. Revision 11: 10/06/2017 Page 7 of 8 / TRINITYERD 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties sppcifications. Plant ifitati Rincu-ci s Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Drummondville, Lastobond Pro HT-N, Lastobond Pro HT-S, Lastobond 195, Lastobond QC (Canada) ASTM D7970 Eaves Protection Sheet Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip-RRe Eave & Valley Protector, RESISTO L81244 ASTM D1970 & FRSA/TRI 04-12 Colphene FR GR Wadsworth, OH Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO L81244 ASTM D1970 & FRSA/TRI D4-12 Lastobond TU HT; Colphene FR GR Gulfport, MS Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave &Valley Protector, RESISTO L81244 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Deskn, U.C. Evaluatbn Report S18030.06.09-R11 Catyl�are ojauMoMmtlan a9503 6rxEDITION(2017)FBC NON-HVHZ EVALUATION FVS69-R13 Soprema, Inc Revision 11: 10/06/2017 Page 9 of 8