HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFINGFILE COPY 2160 5W Poma Drive
Palm City, FL 34990
Compliant with Florida Building Code 2017 (61 ed.) — - RECEIVED
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications NQV 21 2018
ST. Lucie County, Permitting
OCANNEO
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 By
Yield strength: 50 ksi min.; Attached to min. i5/32" plywood or wood�t Lucie COUnty
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #20 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/9" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications ahnvra
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHODEEHODDESIGN
PRESSURE*
-96 PSF
-93.5 PSF
-201 PSFROW
SPACING
16" O.C.
16" o.c.
8" oc.FASTENER
SPACING (ALONG Panel width)
12" o.c.
12" o.e.
12" o.c.FASTENER
SIZE
#9
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#.1527
UL S80-06 & 1897-043 Test Report LI5893.01-450-18 os/02/m
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY--UL 1897-04 is equivalent to test standard UL 2897-1� *Design
pressure margin of safety 2:1
�s nm
Locke Bowden, P,E, does not have, not will acquire a financial iniqLraceuring or distributing products
under this evaluation. �,» L •;`,
Locke Bowden, M is not awned, operated, or controlled by a U aota�pad1PMI JfiAturer� or distributing products under this
report. x � ' n