Loading...
HomeMy WebLinkAboutATI TEST REPORTIt Jut EK*fj YOUR VISION OUR MISSION' December 20, 2012 Mr. Floyd Johnson Style Crest Inc. 600 Hagerty Drive Fremont, OH 43420 RESOURCES APPLICATIONS, DESIGNS & CONTROLS, INC. 3220 E.59TH STREET LONG BEACH, CA 90805 Tel (562) 272-7231 Fa (562) 529.7513 wwW.RA000IRC.cOm email: info@RAOCOinc.corn RE: Review ATI test report on fiberglass coated ptyw s all Dear Mr. Johnson: , Co p for compliance with the most recent code versto AS We have received the test report you submitted from Architectural Testing (ATI), York, PA. The details are as follows: Report number: 01-3791104, dated 11/7103 Title: Step Performance Test Report Products covered: 4-Tread, Dura-Grip It, Step Unit [A five riser, four tread step fabricated with pressure treated lumber and fiberglass]. At your request, we have evaluated the test report against the building codes outlined below. CODE 2006 International Building Code (IBC) Stairway Dimension Requirement Tested Value (2) Compliance Width (1) 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1l2" Pass Tread Leading Edge Radius 1/2" maximum Less than 1/2" Pass CODE 2006 International Residential Code (IRC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36"minimum 3W Pass Riser Height 7-3/4" maximum 7" Pass Tread Depth 10" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 112" Pass v'NYL SIDING INSTITUTE i 'Iv. SWISS INS RYO'L I,. 114nH 4E49EP Mr. Floyd Johnson Style Crest Inc. FIL�7) OPY December20, 1 Page 2 CODE 2007 Florida Building Code (FBC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1P2" Pass Tread Leading Edge Radius 1/2" maximum Less than 1/2" Pass CODE 2009International Building Code ([BC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11"minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass CODE 2009 International Residential Code (IRC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass Riser Height 7-3/4" maximum 7' Pass Tread Depth 10" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass CODE 2010 Florida Building Code(FBC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7' maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9116" maximum Less than 1/2" Pass CODE 2012 International Building Code (IBC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass