RE: Review ATI test report on fiberglass coated ptyw s all
Dear Mr. Johnson: , Co
p
for compliance with the most recent code versto
AS
We have received the test report you submitted from Architectural Testing (ATI), York, PA. The
details are as follows:
Report number: 01-3791104, dated 11/7103
Title: Step Performance Test Report
Products covered: 4-Tread, Dura-Grip It, Step Unit [A five riser, four tread step fabricated
with pressure treated lumber and fiberglass].
At your request, we have evaluated the test report against the building codes outlined below.
CODE
2006 International Building Code (IBC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width (1)
36" minimum
38"
Pass (1)
Riser Height
7" maximum, 4" minimum
7"
Pass
Tread Depth
11" minimum
11-1l2"
Pass
Tread Leading Edge Radius
1/2" maximum
Less than 1/2"
Pass
CODE
2006 International Residential Code (IRC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
36"minimum
3W
Pass
Riser Height
7-3/4" maximum
7"
Pass
Tread Depth
10" minimum
11-1/2"
Pass
Tread Leading Edge Radius
9/16" maximum
Less than 112"
Pass
v'NYL SIDING INSTITUTE
i 'Iv. SWISS
INS RYO'L
I,. 114nH 4E49EP
Mr. Floyd Johnson
Style Crest Inc.
FIL�7) OPY
December20, 1
Page 2
CODE
2007 Florida Building Code (FBC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
36" minimum
38"
Pass (1)
Riser Height
7" maximum, 4" minimum
7"
Pass
Tread Depth
11" minimum
11-1P2"
Pass
Tread Leading Edge Radius
1/2" maximum
Less than 1/2"
Pass
CODE
2009International Building Code ([BC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
36" minimum
38"
Pass (1)
Riser Height
7" maximum, 4" minimum
7"
Pass
Tread Depth
11"minimum
11-1/2"
Pass
Tread Leading Edge Radius
9/16" maximum
Less than 1/2"
Pass
CODE
2009 International Residential Code (IRC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
36" minimum
38"
Pass
Riser Height
7-3/4" maximum
7'
Pass
Tread Depth
10" minimum
11-1/2"
Pass
Tread Leading Edge Radius
9/16" maximum
Less than 1/2"
Pass
CODE
2010 Florida Building Code(FBC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
36" minimum
38"
Pass (1)
Riser Height
7' maximum, 4" minimum
7"
Pass
Tread Depth
11" minimum
11-1/2"
Pass
Tread Leading Edge Radius
9116" maximum
Less than 1/2"
Pass
CODE
2012 International Building Code (IBC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
36" minimum
38"
Pass (1)
Riser Height
7" maximum, 4" minimum
7"
Pass
Tread Depth
11" minimum
11-1/2"
Pass
Tread Leading Edge Radius
9/16" maximum
Less than 1/2"
Pass