Loading...
HomeMy WebLinkAboutFIRE RESISTANCE RATINGSBXU4 V449 - Fire Resistance Ratin€,­ -ANSI/UL 263 ,3 Design No. V449 BXUV.V449 `CANNED Fire Resistance Ratings - ANSI/UL 263 BY SttuCie County-- Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been Investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratinos - ANSI/UL 263 Design No. V449 October 03, 2012 Non -Bearing Wall Rating - 2 hr. 1. Floor and Ceiling Runners — (Not Shown) — Channel shaped, fabricated from min 25 MSG corrosion -protected steel, min width to accommodate stud size, with min 1 in. long legs, attached to Floor and ceiling with fasteners 24 in. OC max. ,IA. Framing Members* - Floor and Ceiling Runner — Not shown - In lieu of Item 1 — For use with Item 2A, proprietary http://database.ul.comlegi-binIXY V/template/LISEXTI1 FRAMElshowpage.html?name=BXU V. V449&... 11/28/2012 BXUV.V449 - Fire Resistance Rating kNSI/UL 263 channel shaped runners, min 3-1/2 in. wide with 1-1/4 in. long legs fabricated from min 0.020 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. ICALIFORNIA EXPANDED METAL PRODUCTS CO — Vlper2WT Track MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper20TM Track I PHILLIPS MFG CO L L C — Viper20TM Track 113. Framing Members*— Floor and Ceiling Runners — (Not shown) — As an alternate to Item 1 - For use with Item 26, 'channel shaped, min 3-1/2 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners 124 in. OC. max. I �CLARXDIETRICH BUILDING SYSTEMS — CD ProTRAK DMFCWBS L L C — ProTRAK MBA BUILDING SUPPLIES — ProTRAK ISOUTHEASTERN STUD & COMPONENTS INC — ProTRAK STEEL STRUCTURAL SYSTEMS L L C — Tri-S ProTRAK 1C. Framing Members* - Floor and Ceiling Runner — Not shown - In lieu of Item 1 —. For use with Item 2C, proprietary channel shaped runners, min 3-1/2 in. wide with 1-1/4 in. long legs fabricated from min 0.020 in. thick galv steel, attached to 'floor and ceiling with fasteners spaced 24 in. OC max. - TELLING INDUSTRIES L L C — Viper20TM Track 1D. Framing Members*— Floor and Ceiling Runners — (Not shown) — As an alternate to Item 1 - For use with Item 2D, (channel shaped, min 3-1/2 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners 124 In. OC. max. ,TELLING INDUSTRIES L L C — TRUE-TRACKT" 2. Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion -protected steel, 3-1/2 in. min width, min 1-1/4 In. flanges and 1/4 in. return, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 In. less than assembly height. 12A, Framing Members* - Steel Studs — Not shown - In lieu of Item 2 — For use with Item 1A, proprietary channel shaped steel studs, 1-1/4 In. deep by min 3-1/2 in. min width fabricated from min 0.020 in. thick galv steel. Studs cut 3/8 to 3/4 in. less in length than assembly height. CALIFORNIA EXPANDED METAL PRODUCTS CO — Viper20TM �MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper20TM ,PHILLIPS MFG CO L L C — Vlper20TM 128. Framing Members*— Steel Studs — As an alternate to Item 2 - For use with Item IS, channel shaped studs, min 3-1/2 'in. wide fabricated from min 0.018 in. thick galv steel, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 In. less than 'assembly height. http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name--BXUV. V449&... 11 /28/2012 BXUV.V449 - Fire Resistance Ratinj ' ANSI/UL 263 iCLARKDIETRICH BUILDING SYSTEMS — CD ProSTUD I DMFCV1BS L L C — ProSTUD MBA BUILDING SUPPLIES — ProSTUD I SOUTHEASTERN STUD & COMPONENTS INC — ProSTUD !STEEL STRUCTURAL SYSTEMS L L C — Tri-S ProSTUD 12C. Framing Members* - Steel Studs — Not shown - In lieu of Item 2 — For use with Item 1C, proprietary channel shaped ;steel studs, 1-1/4 in. deep by min 3-1/2 in. min width fabricated from min 0.020 in. thick galy steel. Studs cut 3/8 to 3/4 in. less in length than assembly height. 'TELLING INDUSTRIES L L C — Vlper20T" '2D. Framing Members*— Steel Studs — As an alternate to Item 2 - For use with Item SD, channel shaped studs, min 3-1/2 tin. wide fabricated from min 0.018 in. thick galy steel, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than 'assembly height. TELLING INDUSTRIES L L C — TRUE -STUD" i3. Gypsum Board* — 5/8 In. thick, 4 ft. wide with beveled, square or tapered edges. Applied vertically with joints centered over studs and staggered between layers. NATIONAL GYPSUM CO — 5/8 in. thick Type FSW, SoundBreak XP Type X Gypsum Board 1 4. Fasteners — (Not shown)- For base layer, 1-1/8 in. Type S screws used to attach panels to studs, spaced 8 in. OC. around 'perimeter and 12 In. OC. In field. Second layer, 1-5/8 in. long Type S screws spaced 12 In. OC. around perimeter and 12 in. OC. in field. Second layer screws staggered 6 in. OC. from base layer. Face layer, 2-1/4 in. Type S screws spaced 8 in. OC. around 'perimeter and 12 in. OC. in field. Face layer perimeter screws staggered 1 in. OC. from second layer and staggered 6 in. OC. in 'field. S. Joint Tape and Compound — Vinyl or casein, dry or premixed joint compound applied in two coats to joints and screw heads of outer layers. Paper tape, nom 2 in. wide, embedded in first layer of compound over all joints of outer panels. *Bearing the UL Classification Mark i Last Updated on 2012-10-03 Ouestions? Print this page Terms of Use Page Too @ 2012 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional informatlon regarding this product's certification. The appearance of a company's name or product in this database does not in Itself assure that products so Identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must Include a copyright notice in the following format: "© 2012 UL LLC". http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=BXUV. V449&... 11 /28/2012