HomeMy WebLinkAboutBUILDING SITE PLANSExisting 8" CBS Wail " Electrical A �— - �j C Panel 2AIOBIZ fire ext. I - \ Toilet . Room 3068 r--761 i 22.5" x 36 ----j 'attic access l l Tenant Space j9'-0" Ceiling j z ' VCT Flooring 1.262 Square Feet Ca _ ro x � I p 1 F---"---i F--:---i 1 1 ®Typ. A.C. Supply F----A --- i I---FA---i 31,_9:: Return Grille Drinking Fountain with Cup Holder 3 So x O Two Hour Rated (V449) Wall Assembl Baselayer'5/8" Type X Gypsum Board applied vertically to each side of 3 1/2 steel studs 24"o.c. with 1 1/8" Type S drywall screws 8"o.c. at vertical joints and wall perimeter and 12"o.c. at intermediate studs. °Second Layer 5/8" Type X Gypsum Board applied vertically to one side with 1 5/8" Type S drywall screws 12 o.c., Finish Layer 5/8" Type X Gypsum Board applied vertically to one side with 2 1/4" Type S drywall screws 8' o.c. at vertical joints and wall perimeter and 12"o.c. at intermediate studs. Joints Staggered 24"o.c: on each layer and,side. Ving1 or Casein, dry or premixed joint compound applied in two coats to Joints and screw heads of outer layers. Paper tape, nom. 2" wide, embedded in the first layer of compound over all joints of outer panels. x W Existing 25ga Flc - z and Ceiling Rum with 3 5/8' 25ga. studs 24"o.c. 3W `) EXI - I Existing D.WJ Ceiling Remove a section of the existing d.w. cing. as needed to install the new drywall to the roof deck Add Two Layers of 5/8" Type X Gypsum to the existing wall / assembly. By adding J the new layers of d.w. The total assembly will be Two Hour Rated as per Design No. V449 Penetrations through new Type X Gypsum to be caulked with 3M Firestopping Caulk. Application to folllow manufacturers direction. Existing Conc. Foundation -\ Existing Plywood Roof Deck Bottom of Roof Deck Existing Wood Roof Trusses 24"o.c. 91-01, Existing One Hour Tenant Seperation Wall (Design No. U465) One layer of 5/8" Type X gypsum on each side of 3 5/8" metal studs --- 0.00' Existing 8" CBS Wall m I o0 Retrofit Tenant Seperation Wall Two Hour Rated (Design No. V449) Level & Covered Conrete Sidewalk — Wall Key Mop Sink Service Basin Existing Tenant Space HVAC NOTES Mfg: Elfin Existing Building Scale: 1/4" = F-O" HVAC system already exists Model: EB-54 and is to be unchanged. Size: 24" x 24 x:6" New Interior Frame Walls Install 16" S.S. Splash Guards (Non Load Bearing) FINISH CLASSIFICATION and Map sink Faucet Unsprinklem GENERAL REQUIREMENTS mm, 8 i BACK REQ. Occupancy Group: 40 All work,to be as per the current edition of the Florida Building Code _. Exit Passage: A and meet or exceed all applicable local requirements. Fl"M r Corridors: A General contractor is responsible for all labor, materials, utilities, testing, SIDES __ ROOmS' C waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly CNR 510 identified here.. REAR �_ INTERIOR WALL FRAMING Owner is responsible for all municipal related charges such as impact ZNG. Non Load Bearing walls to be 2 x 4 studs 24' o.c. fees, and water connection, except building permit fees, which are to be TECH, Spruce, Pine, Fir (SPF) #2 Grade Lumber or Better. included in the construction bid. or Metal Studs (25 Gauge). Crimper may be used General contractor to check 0 drawings for errors and ommissions and in lieu of screws. bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and omrmssions are not reported in writingto the architect, any resulting GENERAL CONCRETE NOTES: damages or costs shall be born entirely by the general contractor. In the event that the existing concrete slab needs to be cut Architect is not responsible for the contractors method or means of ensure the following: Concrete shall have a minimum compressive construction. compressive strength of not less than 3000 p.s,i. over compacted, and termite treated soil. General contractor is to keep the site in a clean and safe state through out the course of construction On buildin turnover eneral contractor to DOOR SCHEDULE Size Door Frame Fire Rating Notes profile Face Core Finish Material Threshold Finish 36" x 80" x 1 3/8" Six Panel Masonite Hollow Painted Wood N.A. Painted N.A. Swing Door 24" x 80" x 1 3/8" Six Panel Masonite Hollow Painted Wood N.A. Painted N.A. Bifold Door All toilet room doors to have privacy sets, Male / Female Graphic & Braile Lables All doors to be Medium Duty Thresholds not to exceed 1/2" max. heigth All handsets to be lever type,brushed chrome finish clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All drawings are not considered complete until the plans have been reviewed by the building department and the building permit has been issued. All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. Existing One Hour Rated Wall (UL: U465) New Two Layers of 5/8" Type X Gypsum Board (New Two Hour Rating UL: V449) '17�" _ New Floor Plan Scale: 1/4 I' 0" Existing Electric Panel N r, Existing Tenant Space 9'-0" Ceiling , 31'-6" 0n G i w Existing Toilet Rm. Relocate Plumbing Fixtures as Shown00 V l� H H � Z M F.E 1_ E-a w Cut In New li I I -2068 Service I I I I `l Door for A.H. Z, +� 06800 ng LJ_ _1J______t____ New Location Q `�, .� �� of the Existing —(17, Return Air Grille a) Z New I Raise Existing A.H. /1 Mop Plateform so to H I Sink Raise Return Air r-�l w Grill Above New Mop Sink Frame in Existing New I Return Air Grille I Toilet Room Z 168 `. ; > V* o Exist. Drink Fountain with Q Cup Holder Verify Location of Drinking Fountain with Required Floor Clearence 1 1 /2" Existing One Hour CZ U n n Rated Wall C7, N (UL: U465) FLI x o 00 New Two Layers r„ t U of 5/8" Type X o Gypsum Board �+ z (New Two Hour Q W Rating UL: V449) Cn Cn -- 1 ti Scope of Work Add an addition accessable toilet room, remodel existing toilet room to meet the current accessability requirements, and update the existing tenant Seperation walls from one hour rating to two hour rating Project Data Building Data Project Name: Martial Arts Studio Occupancy Type: Group A-3 Street Address: Drawdy Professional Center Construction Type: IIIB City: Ft. Pierce County: St. Lucie Number of Stories: One State: Florida Number of Seats: N.A. Project Area: 1262 s.f. (Existing) Building Code Alterations - Level 2 2010 Florida Building Code: Building ' Fire Protection Requirement 2010 Florida Building Code: Existing Building 2010 Florida Building Code•: Plumbing ! 2010 Florida Building Code: Mechanical Required Provided ! 2010 Florida Building Code: Accessibility Party & Fire Walls: 2 2 2010 Fire Prevention Code: NFPA 101 Structural Frame' including columns: 0 0 Girders & Trusses: 0 0 Florida Building Code Data Exterior Bearing Walls: 2 2 r Interior Bearing Walls: 0 N.A. Use Group: Assembly Group A-3 Floor Construction: 0 0 Type of Construction: IRB Unprotected Roof Construction: 0 0 Occupant Load: Exercise Rooms without Equipment: ` 1262 s.f. / 15 = 84 Occupants Life Safety System Required Provided Emergency Lighting: Yes Egress Width: .2" per person x 84 16.8" 9611 Exit Signs: Yes Panic Hardware: No Length of Dead End Corridor: 20.0' 4.5' Fire Suppression: No Maximum Distance to Exit: 200.0' 42.5' Fire Alarm: No Minimum Number of Exits: 2 2 Fire Extinguisers: Min. 2A10BC �M o Z w 0 o U Q � � Q Z w U O W � U O Q N W � � z .^5,6ANNED BY St Lucie County date revision drawn s.l. checked s.l. date 10/26/12 scale as noted job number 12042 sheet A-1 T-1" Rxistinir Floor Clearances Toilet Room Doors to have Lever Handle and Privacy Lock Lavatory or Sink Controls to be Lever Types Doors shall have signs indicating ADA Accessable Restroom Grab Bars to be 1 1/4" to 1 1/27, dia. and 1 1/2" from walls A.D.A. Toilet Doom r sulate all T under UcpL„ Lavatory Clearances (E) 3/4'! Existing Sanitary Main -- L)-- Offset existing Water Closet drain to new Water Closet Location /7—--- (E) -- ------------ \_Existing 1 3" VTR p� Cap off drain lines at existing lavatory 473' t� 3" VT i i Exist. Drink Fountain with ®i Cup Holder 011 ii it Plumbing Plan Scale: 1/4" = 1'-0" 3/4" (E) WC 3/4, (E) 2" supply to meter Cap off drain lines at existing lavatory -\ Plumbing contractor to provide a water hammer and shut off valve at each fixture Existing Sanitary PLUMBING NOTES: Plumber to consult with contractor and equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior, to construction All sanitary lines 2" or less shall have a slope of 1/4" per foot minimum. All sanitary lines above 2" shall have a slope of 1 /8" per foot minimum. 1/2" Lav 3/4" WC 1 1/2" 3/4" 100 Lav 3/4 3/4" Mop Sink Water Supply n.t.s. (E) 3" VTR ew 1 1/2" ent Lav WC New Lay. 3" Location 1� " 33 (E) WC Sanitary Riser n.t.s. Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the Florida Electrical Code & requirements of F.P.L. 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. See exterior elevations for illuminated tenant sign locations. Ensure to provide power, weather proof junction box, and switch box for each 5. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 6. Ensure min. 36" clear between equipent and disconnects, Typical. 7. Protective ratings shall comply with NEC 110-9 & NEC 110-10 y S. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1 9. Clearance between boxes and cutouts in wall shall not exceed 1/8". Description: Electrical Schedule 100 MLC ectrcacedule I.T.E. Load Center 1 PH 3W 120/240V Circuit Description Volts Load KW Breaker Wire Cond. Trip Pole T.B.D. New Toilet Room 120 1.2 KW I 20 A I I P 1 2 412 1 1/2" New Additional Load 1.2 KW First 10 KW at 100% 10.00 KW Total Calculated New Load 1.2 KW 1,200 W = 5 Additional Amps 240 Existing Panel Load: 42.80 Amps Total Calculated Panel Load: 47.80 Amps (100 Amp Panel Existing) Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate elvetrical schedule if loads are to be modified ELECTRICAL LEDGEND \ll� RECESSED LIGHT WITH LENS @ EXTERIOR & WET LOCATIONS T SURFACE MOUNTED LIGHT FIXTURE SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE ( INCH LIGHTS ) RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN O CEILING MOTION SENSOR EXHAUST FAN OUTLET PX9 DOOR CHIMES THERMOSTAT SMOKE DETECTOR =cr DUPLEX OUTLET - SWITCHED -}a TELEVISION DUPLEX OUTLET 220 V OUTLET TELEPHONE -VY SWITCH O PUSH BUTTON -W .. THREE WAY SWITCH EMERG. FLOOD LIGHT sw W/ BATTERY BACKUP D DIMMER SWITCH EXI ILLUM. EXIT LIGHT W/ BATTERY BACKUP NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS 0C H � � Z cn � H w z tA C) Q� Z 'b r • r—t C/) w C/2 GU � oa Q � v � z > w o Q t^1 ai U U In W C' N o H a 00 v o 00 > x CD � Z Cn 0 drawn checked s.l. date 1026/12 scale as noted job number 12042 Sheer A-2 Water Closet Clearances L Existing 8" CBS Wall 11 Z - Electrical 3t ' Panel 2A 1 OB ( fire ext. 9 )l i I22.5"x36" i attic access Tenant Space I 9'-0" Ceiling I VCT Flooring I 1.262 Square Feet t m / / t l 1 1 I / � O Toilet\ Room Z Typ. A.C. 1 ' Supply F--- 4-'---i t-- �:---1 31'-9„ 3W EXI Existing 8" CBS Wall CD m cn Level & Covered i onrete Sidewalk Existing Tenant Spice Scale: 1/4" = F-0" FILE COPY �ECEOWEL DEC 1 0 2012 Return Grille ® z Drinking Fountain e with Cup Holder a x O Two Hour Rated (V449) Wall Assembl Base layer 5/8" Type X Gypsum Board applied vertically to each side of 3 1/2" steel studs 24"o.c. with 1 1/8" Type S drywall screws 8"o.c. at vertical joints and wall perimeter and 12"o.c. at intermediate studs. Second Layer 5/8" Type X Gyppsum Board applied vertically to one side with 1 Type S drywall screws 12"o.c., Finish Layer 5/8" Type X Gypsum Board applied vertically to one side with 2 1/4" Type S drywall screws 8' o.c. at vertical joints and wall perimeter and 12"o.c. at intermediate studs. Joints Staggered 24"o.c. on each layer and side. Vinyl or Casein,.dry or premixed joint compound applied in two coats to joints and screw heads of outer layers. Paper tape, nom. 2" wide, embedded in the first layer of compound over all joints of outer panels. w Existing 25ga Floor z and Ceiling Runners with 3 5/8" 25ga. studs 24"o.c. 1xisting Plywood f Deck — _ — Bottom of Roof Deck Existing Wood Roof Trusses 24"o.c. — - — --$- 9'-0" Provide Panic &Fire Exit � Hardware as per 1008.1.10 .� � F.B.C. W� Existing JF.EElectric Panel I Existing u-N,__l�_. `4 New FILL COPY m iSio Sink�� Hill�� Existing D.W� Ceiling r Remove a section of the existing d.w. cing. as needed to install Existing One Hour the new drywall to the Tenant Seperation roof deck Wall (Design No. U465) One layer of 5/8" Type X gypsum on each side of 3 5/8" metal studs Existing One Hour Rated Wall (UL: U465) Add Two Layers of 5/8" Type X Gypsum to the existing wall New Two Layers assembly. By adding of 5/8" Type X the new layers of d.w. Gypsum Board The total assembly will (New Two Hour be Two Hour Rated as Rating UL: V449) per Design No. V449 lo Penetrations through new Type X Gypsum to be caulked with 3M Firestopping Caulk. Application to follllow manufacturers direction. Existing Conc. Foundation --- 0.00' Retrofit Tenant Seperation Wall Two Hour Rated (Design No. V449) Wall Key HVAC NOTES Mop Sink Service Basin HVAC system already exists Existing Building and is to be unchanged. Mfg: Elfin Model: EB-54 Size: 24" x 24" x 6" I New Interior Frame Walls FINISH CLASSIFICATION Install 16" S.S. Splash Guards (Non Load Bearing) and Mop Sink Faucet Unsprinklered Occupancy Group: A-3 GENERAL REQUIREMENTS Exit Passage: A All work to be as per the current edition of the Florida Building Code Corridors: A and meet or exceed all applicable local requirements. ROomS: C General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here. INTERIOR WALL FRAMING - Owner is responsible for all municipal related charges such as impact Non Load Bearing walls to be 2 x 4 studs 24"o.c. g fees, and water connection, except building permit fees, which are to be included in the construction bid. Spruce, Pine, Fir (SPF) #2 Grade Lumber or Better. or Metal Studs (25 Gauge). Crimper may be used General contractor to check all drawings for errors and omrnissions and in lieu of screws. bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting GENERAL CONCRETE NOTES: damages or costs shall be born entirely by the general contractor. In the event that the existing concrete slab needs to be cut Architect is not responsible for the contractors method or means of ensure the following: Concrete shall have a'mihimum compressive construction. compressive strength of not less than 3000 p.s.i. over compacted, and termite treated soil. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust grease stains scuffs etc. DOOR SCHEDULE Size Door Frame Fire Rating g Notes. Profile Face Core Finish Material Threshold Finish 36" x 80" x 1 3/8" Six Panel Masonite Hollow Painted Wood N.A. Painted N.A. '' Swing Door 24" x 80" x 1 3/8" Six Panel Masonite Hollow Painted Wood N.A. Painted N,A, Bifold Door All toilet room doors to have privacy sets, Male / Female Graphic & Braile Lables All doors to be Medium Duty Thresholds not to exceed 1/2" max. heigth All handsets to be lever type,brushed chrome finish Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All drawings are not considered complete until the plans have been reviewed by the building department and the building permit has been issued. All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. Existing Tenant Space' 9'-0" Ceiling 1 1/2" 3 F-6" tHa idePanic &Fire Exit ware asper 1008.1.10C17777,77 New Toilet Room Existing Toilet Rm. Relocate Plumbing Fixtures as Shown (� Exist. Drink L nk T-4 1/2 1 1/2" Existing One Hour Rated Wall (UL: U465)r New Two Layers of 5/8" Type X Gypsum Board (New Two Hour Rating UL: V449) 1 1/2' 00 00 ~ E� C) ,p o Cut In New �� '4 /-2068 Service for A.H. �./ j Door 00 New Location O -. of the Existing Return Air Grille to a Q� Z Raise Existing A.H. Plateform so to Raise Return Air Grill Above New W Mop Sink Q N Frame in Existing `,, o Return Air Grill rll ZVerify Location of ~ Drinking Fountain F with Required Floor LT~ Clearence . Q C� wr--t ., r-t E , MIN, SETBACK REO, U V-) Cn" a FRONT SIDES n/ 0 00 d CNR SIDE rr--4 U REAR py z ZNG. TECH. � a � �� Floor Plan W��CONCEALEDFASTENERS ORATTACHENTS oZNew _ ARE THE RESPONSIBILrry OF THE O Scale: 1/4" = 1'-0" CNiRACTOROFAECOAD. z TNUIPLANS AND ALL PROPOSED WORK Scope of Work Q AAI 106TTOANYCORRECTIONS Add an addition accessable toilet room O AIQUTAIDBYFIELDINSPECTORSTHAT > � NNiti II NECESSARY IN OADEA TO remodel existing toilet,room to meet the p w current accessability requirements, and Z (2NiYriTHA+MWQAA6ICODA update the existing tenant seperation walls W�4 Z from one hour rating to two hour rating O 4 Project Data Building Data REVIEWED FOR COMPLIANCE U SUBJECT TO FIELD INSPECTION] Project Name: Martial Arts Studio Occupancy Type: Group A-3 SEE ATTACHED V SION SHE Street Address: Drawdy Professional Center U City: Ft. Pierce 'Construction Type: IIIB tY REVIEWED- -Number umber of Stories: One County: 5t. Lucie -)ATE: State: Florida Number of Seats: N.A. Project Area: 1262 s.f. (Existing) E- Bullding Code Alterations - Level 2010 Florida Building Code: Building Fire Protection Requirement 2010 Florida Building Code: Existing Building 2010 Florida Building Code: Plumbing Required Provided 2010 Florida Building Code: Accessibility Party &Fire Walls: 2 2 dam eV151D" 2010 Fire Prevention Code Strut turaf Frame including columns: 0 0 12/2/12 Plan mReview 2009 Life Safety Code: NFPA 101 Girders & Trusses: 0 0 Exterior Bearing Walls-. 2 2 Florida Buil ing Co e Data Interior Bearing Walls:: 0 N.A. Use Group: Assembly Group A-3 Floor Construction: 0 0 drawn Type of Construction: IIIB Unprotected Roof Construction: 0 0 S.I. checked s.i. Occupant Load: date Life Safety System 0cale Exercise Rooms without Equipment: 1262 s.f. / 15 = $4 Occupants y y ��� - $� sate Required Provided Emergency Lighting: :Yes ST. LUCIE COUNTY as noted 2042 Exit signs: Yes PLAN REVIEW jab aumber Egress Width: .2" per person x 84 16.8" 96" Panic Hardware: No " Length of Dead End Corridor: 20.0' 4.5' Fire Suppression: No sheet Maximum Distance to Exit: 200.0' 42.5' Fire Alarm: No A_ 1 Minimum Number of Exits: r DATE 2 2 Fire Extinguisers: Min. 2Al0BC -�— ELEC: EDATME- ATE: MB: : H: ' �� 7'-1" FX1Ri'.inff Ir 1VV1 \J1NU1 µ11V VO Toilet Room Doors to have Lever Handle and Privacy Lock Lavatory or Sink Controls to be Lever Types Doors shall have signs indicating ADA Accessable Restroom Grab Bars to be 1 1/411 to 1 1/2" dia. and 1 1/2" from walls A.D.A. Toilet Room r bar at wall M isulate all Ipcs under ni: Water Closet Clearances Lavatory Clearances (E) 3/4': Existing Sanitary Main M MENVE rAl Offset existing Water Closet drain to new Water Closet Location (E) Existing 3" VTR I I \ Cap off drain ' I i lines at existing 11 lavatory Exist. Drink Fountai❑ I 11 New Drin Fountain , it Plumbing Plan Scale: 1/4" = 1'-0" 3/4" (E) WC 1/2" 3/4': PLUMBING NOTES: Plumber to consult with contractor and_equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. All sanitary lines 2" or less shall have a slope of 1/4" per foot minimum. All sanitary linesab(ve 2" shall have a slope of 1/8" per foot minimum. 3� �� illr ;two 1/2" Lav 3/4" WC l 3/4" 3/4" Mop Sink w (E) Water Supply 2" supply n.t.s. to meter New 3" VTR Cap off drain lines at existing lavatory 1 Plumbing contractor to provide a water hammer and shut off valve at each fixture 5" 15" Existing Sanitary TT ----- O a E _ ti p O 8' E a nln. .V Spout Hght. & Knee Clearance Equipment permitted in shaded area HiLo fountain required as shown (E) 3" VTR ew 1 1/2" ent Lav I I I WC I New Lay. 3" Location I 3" 3" �(E) WC Mop1 3" 2" Sink Sanitary Riser n.t.s. Existing F.E Electric Panel g11 E 1� O/Relocate Elect. Ftxtures As Shown Ell, gll I tE \ Existing Tenant Space \ \ All existing electrical fixtures \ to remain, only fixtures that E V ' need to be relocated, removed, \ or added are shown on this \ drawing Extend Existing \ Receptical Boxes Flush with New \ Drywall (Typ.) \ \ \ \ E \ \ \ \ \ New Electrical Plan New 1 1/2" Scale: 1/4" = F-0" `Vent - �IElectrical Notes = UE.- I 1. All loads to be checked by a Florida Licensed Electrician I I I 2. All work to meet the 2008 National Electrical Code. I I I 3. Calculations and panels below are for sizing conduit and overall I Lav building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box 2" for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipent and disconnects, Typical. 6. Protective ratings shall comply with NEC 110-9 & NEC 110-10 7. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1 8. Clearance between boxes and cutouts in wall shall not exceed 1/8". Description: Electrical Schedule 100 MLC ecrcacedule I.T.E. Load Center I PH 3W 120/240V Circuit Description I Volts Load KW Breaker Wire Cond. Trip Pole T.B.D. Nevv Toilet Room 120 1.2 KW 20 A I 1 P 2 #12 1 1/2" New Additional Load 1.2 KW First 10 KW at 100% 10.00 KW Total Calculated New Load 1.2 KW 1,200 W = 5 Additional Amps 240 Existing Panel Load: 42.80 Amps Total Calculated Panel Load: 47.80 Amps (100 Amp Panel Existing) Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY U NECESSARY IN ORDER TO pI11iINM'IdtN11m r�A�, Cap Off Existing Receptical ELECTRICAL LEDGEND RECESSED LIGHT WITH LENS @ EXTERIOR & WET LOCATIONS �.} SURFACE MOUNTED LIGHT FIXTURE --- `TT,---i SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE ( INCH LIGHTS) N—ej RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN O CEILING MOTION SENSOR O EXHAUST FAN OUTLET ® DOOR CHIMES bTHERMOSTAT S® SMOKE DETECTOR $ DUPLEX OUTLET - SWITCHED —1" TELEVISION � DUPLEX OUTLET 220 V OUTLET TELEPHONE -6T SWITCH PUSH BUTTON Kfr THREE WAY SWITCH EMERG. FLOOD LIGHT 3W W/ BATTERY BACKUP -b7 DIMMER SWITCH ILLUM. EXIT LIGHT W/ EXl BATTERY BACKUP NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F. ALL 120V SINGLE PI4ASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARF NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP 13RANCII CIRCUITS 0C 00 D 11C DO V `It z 0C 0" Con a� z Un W _ z v 1 Q � w U c 0 00 r-1 U. z ¢ n/ tWis �.Gi oc dam revision' 12/2/12 Plan Review Comments drawn s.l. checked s.l. dam IO/26/12 seal, as noted jab .umber 12042 sheet A-2