Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
Florida Energy Efficiency Code For Building Construction EnergyGauge Summit® Fla/Com-201 % Effective Date: March 1'5.2012 — Form 506-201 T Total Building Performance Method "for Commercial Buildings BY PROJECT SUMMARY Short Desc: OFFICE Description: DRAWDY BROS Owner: DRAWDY BROS Addressl: ST. LUCIE CO City: FT. PIERCE Address2: FLORIDA State: FLORIDA Zip: 0 Type: Office Class: New Finished building Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Conditioned Area: 3600 SF Conditioned & UnConditioned Area: 3600 SF No of Stories: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 3.5 If different, write in: REVIEWED FOR COMP E SUBJECT TO'FIEL PECTIONS E ATTAC REVISION SHEET REVI FILE Copy EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 2/5/2013 Page 1 of 7 Component Design Criteria Result Gross Energy Cost (in $) 2,465.0 2,504.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 2/5/2013 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: PAUL WELCH INC. Building Official: r Date: FIB 0 O 2013 Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: DRAWDYBROS Date: If Required by Florida law, I hereby certify (") that the system design is in compliance with the Florida Energy Efficiency Code Electrical Designer: - Reg No: Lighting Designer: Reg No: Mechanical Designer: PAUL WELCH INC. Reg No:, 29945 Plumbing Designer: Reg No: . (') Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit© RaXom-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 5/2013 Page 3 of 7 Project: OFFICE Title: DRAWDY BROS Type: Office (WEAFile: FL ST LUCIE CO INTL.tm3) Building End Uses 1) Proposed 2) Baseline Total 158.20 200.40 $2,465 $3,130 ELECTRICITY(MBtulkWhf$) 158.20 200.40 46334 58724 $2,465 $3,130 AREA LIGHTS 26.80 41.40 7839 12128 $417 $646 MISC EQUIPMT 54.00 54.00 15823 15823 $842 $843 PUMPS & MISC 0.10 0.10 21 23 $1 $1 SPACE COOL 41.20 46.90 12061 13753 $642 $733 SPACE HEAT 2.20 6.30 649 1846 $35 $98 VENT FANS 33.90 51.70 9941 15151 $529 $808 Credits Applied: None PASSES Passing Criteria = 2504 Design (including any credits) = 2465 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 78.8% EnergyGauge Summi* FlalCom-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 /5/2013 Page 4 of 7 I External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: OFFICE Title: DRAWDY BROS Type: Office (WEAFile: FL ST LUCIE CO INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ED (sq.ft) CP CP once OFFICE 17 Office -Enclosed 3,600 20 2 PASSES PASSES Project: OFFICE Title: DRAWDY BROS Type: Office (WEAFile: FL ST LUCIE CO INTL.tm3) System Report Compliance OFFICE System I Constant Volume Air Cooled No. of Units Single Package System < 3 65000 Btu/hr i Component Category Capacity Design EfI Design IPLV Comp- i Eff Criteria IYLV Criteria liance j Cooling System Air Conditioners Air Cooled 13.00 12.23 1.00 PASSES Single Pkg < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling System Air Handler (Supply) - 0.80 0.82 PASSES -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System (Sup) Air Distribution ADS System (Ret) 6.00 4.20 PASSES System (Ret) PASSES EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 i2/5/2013 Page 5 of 7 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV Hance None Water Heater Compliance DDesign Min Design Max Comp Description Type Category Eff Eff Loss Loss Hance None Piping System Compliance Category Pipe Din Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] NoneTj 1 12/5/2013 I EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 Page 6 of 7 :t: OFFICE DRAW DY BROS Office k File: FL_ST_LUC1E_CO_INTL.tm3) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 506.4.2 Input Report Print -Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows & Doors 502.3.2 Glazed swinging entrance & revolving doors: max. 1.0 cfin/ft2; all other products: 0.3 cfm/ft' Joints/Cracks 502.3.3 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling Cavity 502.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls HVAC Efficiency 503.2.3 Minimum efficiencies: Tables 503.2.3(1)-(8) El HVAC Controls 503.2.4 Zone controls prevent reheat (exceptions); separate thermostatic El control per zone; Ventilation 503.2.5 Outdoor air supply & exhaust ducts shall have dampers that El automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed ❑ HVAC Ducts 503.2.7 Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Table 503.2.7.2. Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s) tested & balanced. Report in ❑ construction documents. Piping Insulation 503.2.8 HAC and service hot water. In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2. Heat trap required. Swimming Pools 504.7 Vapor -retardant or liquid cover or other means proven to reduce El heat loss on heated pools; Time switch (exceptions); readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met ❑ Lighting Controls 505.2, 502.3 Automatic control required for interior lighting in buildings >5,000 s.f; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summi* Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 I2/5/2013 Page 7 of 7 Project Name: OFFICE Project Title: DRAWDY BROS Address: ST. LUCIE CO FLORIDA State: FLORIDA Zip: 0 Owner: DRAWDY BROS EnergyGauge Summit® A.10 INPUT DATA R.EPOR Proiect Information Orientation: North Building 1'ype: Office Building Classification: New Finished building No.of Stories: 1 GrossArea: 3600 SF Zones No Acronym Description Type Area [so Multiplier Total Area [sf] 1 OFFICE Zone 1 CONDITIONED 3600.0 1 3600.0 ❑ Spaces No Acronym Description Type Depth IN Width Height Multi [ft] [ft] plier Total Area [st] Total Volume lei] 2/5/2013 EuergyGauge Summit® v4.10 1 In Zone: OFFICE 1 OFFICE DRAWDYBROS Office - Enclosed 40.00 90.00 10.00 1 3600.0 36000.0 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: OFFICE In Space: OFFICE 1 Recessed Fluorescent - General Lighting 40 64 2560 Manual On/Off 20 No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [Ib/ci] [h.sf.F/Btu] [Btu/sf.F] In Zone: OFFICE 1 DRAWDYBROS 8"CMU/3/4"ISO 90.00 10.00 1 900.0 North 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 2 DRAWDYBROS 8 CMU/3/4"ISO 90.00 10.00 1 900.0 North 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 GYP 3 DRAWDYBROS 8"CMU/3/4"ISO 40.00 10.00 1 400.0 North 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 GYP 4 DRAWDYBROS 8"CMU/3/4"ISO 40.00 10.00 1 400.0 North 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 GYP Windows No Description Type Shaded U SHGC Vis.11a W H(Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] 2/5/2013 EnergyGauge Summit® v4.10 I—InZone: OFFICE In Wall: S WALL 1 DRAWDYBROS User Defined No 1.2500 0.82 0.76 66.00 4.00 1 264.0 Doors No Description Type Shaded? Width H (Effec) Multi IN [ft] plier Area [sf] Cond. Dens. Heat Cap. R-Value [Btu/hr. sL F] Ub/cf] [Btu/sL F] [h.sEFBtal In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area IN [ft] plier [sf] Tilt [deg] Cond. Heat Cap [Btu/hr. SE F] [Btu/sf.F] Dens. R-Value [lb/cf] [h.sEFBtu] In Zone: OFFICE 1 DRAWDY BROS Mtl Bldg Roof/R-19 Batt 90.00 40.00 1 3600.0 0.00 0.0492 1.34 9.49 20.3 ❑ Skylights No Description Type U SHGC Vis.TYans [Btu/hr sf F] W [ft] H(Effec)Multivlier [ft] Area Total Area [St] [Sf] In Zone: EIn Roof: Floors No Description Type Width H (Effec) Multi Area [ft] [ft] plier [sf] Cond. Heat Cap. Dens. [Btu/hr. sE F] [Btu/sE F] Rb/cf] R-Value [h.sEFBtu] 2/5/2013 EnergyGauge Summit® v4.10 3 InZone• OFFICE I DRAWDY BROS 1 ft. soil, concrete floor, carpet and rubber pad 90.00 40.00 1 3600.0 0.2681 34.00 113.33 3.73 ❑ Systems OFFICE System 1 Constant Volume Air Cooled Single No. Of Units 3 Package System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 4 Air Distribution System (Sup) 5 Air Distribution System (Ret) 42000.00 44000.00 1400.00 13.00 1.00 1.00 0.80 6.00 6.00 ❑ ❑ ❑ ❑ ❑ Plant Equipment Category Size Inst.No Elf. fPLV Lj Water Heaters W-Heater Description Capacit7Cap.Unit 1/PRt. Efficiency Loss Fact -Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] 2/5/2013 EnergyGauge Summit® A.10 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? 11 Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sCF] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.s£F] ASHULSg1C1rA11 User Defined 1 1.2500 0.8200 0.7600 ❑ Frm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sGF/Btu] [it] [Btu/h.ft.F] [Ib/ct] [Bt"b.F] o .2000 BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 8 No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 105 Mat1I05 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Mat123 6 in. Insulation No - 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, 3/8IN No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 2/5/2013 EnergyGauge Summit® v4.10 5 Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sEF] Vb/cf] [h.sEFBtu] 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 9.70 62.72 3.8 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 105 CONC BLK HW, 8IN, HOLLOW 0.6667 0.000 ❑ 2 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sf.F] Vb/cf] [h.sEF/Btu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 ❑ 2 23 6 in. Insulation 0,5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sEF] [Ib/cf] [h.sEF/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 2/5/2013 EnergyGauge Summit® v4.10