Loading...
HomeMy WebLinkAboutBUILDING SITE PLANSa'-4" 9-0" 5'-2" S'-2" .ri'_i" s,'-in" 'J'_d" i'J'_r - DOOR SCHEDULE Mark Size Door Frame Fire Rating Notes Profile Face Core Finish Material Threshold Finish A 36" x 80" x 1 3/8" Six Panel Masbnite Hollow Painted Wood N.A. Painted N.A. Swing Door B 30" x 80" x 1 3/8" Six Panel Masonite Hollow Painted Wood N.A. Painted N.A. Bifold Door GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor Is responsible for all labor, materials, utilities, testing, waste removal, store a, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project, unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be Included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any the of the respective division of work If such errors and ommissions are not reported n writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction General contractor is to keep the site In a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the Installation of specified hardware shall conform to the manufacturers instructions and standard practice. All drawinnggs are not considered complete until the plans have been reviewed by the building department and the building permit has been Issued. All wood In contact with masonry shall be pressure treated or approved separating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. All toilet room doors to have privacy sets, Male / Female Graphic & Braile Lables All doors to be Medium Duty Thresholds not to exceed 1/2" max. heigth All handsets to be lever type, brushed chrome finish Plumbing Code Data 34 Occupants -- 17 Males 17 Females Fixtures: Ratio Required Provided Male Female Male Female Male Female Unisex Water Closets: 1/25 1/25 1 1 1 1 1 Lavatories: 1/40 1/40 1 1 1 1 1 Urinals: 0 0 Service Sink: 0 0 Drinking Fountain: 1/100 1 "Hi Lo" 1 "Hi Lo" INTERIOR WALL FRAMING Non Load Bearing walls to be 2 x 4 studs 24"o.c. Spruce, Pine, Fir (SPF) #2 Grade Lumber or Better. or Metal Studs (25 Gauge). Crimper may be used in lieu of screws. GENERAL CONCRETE NOTES: Mond Suuctur. Mill Symbol W FS.S33.027, F.A.C. MAd012, and RA,C, oY-00,0081 ❑ ❑ 54" min. In the event that the existing concrete slab needs to be cut ST.ILUCIE000NTY ensure the following: Concrete shall have a minimum compressive PLAN REVIEW compressive strength of not less than 3000 p.s.i. over compacted, and termite treated soil. DAT6l REVIEWED FOR COMPLIANCE ELEC: SiJBJECTTO FIELD INSPECTIONS DAT1 SEE ATTACHED RE.VISIOIJ SHEET PLUMB: R� REVIEWED: DATE: MECH DATE: - Cl? DATE: 12" co Zo o d �' o M Y r Do not locate tissue holder behind the grab bar Water Closet Clearances bar at Wall CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOROFRECORD Insulate he water pipe under sink UWui Lavatory Clearances r�—!`71 New Interior Frame Walls (Non Load Bearing) FINISH CLASSIFICATION 5" 15" f� Unspr¢nkk erect OCCUpancy , Group: B Exit assagb: A Corridors: A Rooms: C d ca c °O E c_ N c E MIt- N 1 Spout Hght & Knee Clearance Equipment permitted in shaded area HiLo fountain required as shown Project Data Building Datacc vc Project Name: Chamber of Commerce Occupancy Type: Group B Street Address: 2935 West Midway Rd. Construction Type: IIIB CE City: Ft. Pierce Number of Stories: One : County: St. Lucie Number of Seats: N.A. C Z Stet®: Florida d to Project Area: 3,398 s.f. (Gross) �` 05 0 Existing Building Code .� o 2010 Florida Building Code: Building Utilities ,� C 2010 Florida Building Code: Existing Building City Water " 2010 Florida Building Code: Plumbing Public Sewer System Z CO co 2010 Florida Building Code: Mechanical •y _ LL 2010 Florida Building Code: Accessibility = I— c 2010 Fire Prevention Code: NFPA 101 Co LL -Z= as 2008 National Electrical Code U Q cc 0 Florida Building Code Data J m Use Group: Business Group B (Office) i> iz Type of Construction: IIIB Unprotected � a - Occupant Load: 3,398 (Gross) s.f. / 100 = 34 Occupants Egress Width: .2" per person x 34 6.8" 288" Length of Dead End Corridor: 20.0' 9.0' Maximum Distance to Exit: 75.0' 51.3' Minimum Number of Exits: 1 9 Fire Protection Reauirement Required Provided Party & Fire Walls N.A. Structural Frame including columns: 0 0 Girders & Trusses: 0 0 Exterior Bearing Walls: 2 2 Interior Bearing Walls: 0 N.A. Floor Construction: 0 0 Roof Construction: 0 0 Life Safetv Svstem Emergency Lighting: Yes Exit Signs: Yes Panic Hardware: No Fire Suppression: No Fire Alarm: No Fire Extinguisers: Min. 2A10BC Interior renovation of three individual tenant rental spaces to be one individual business. Existing HVAC to remain but modified. Existing electrical panels to remain. Total interior space 3,398 sq. ft. 7-2" Existing 1'-4" 5'-0" min. 31 New location of19"Wx17"D Lavatory � 3068 Ico %r mi i 60" dia. Turn Radius I 1. " I �`—�\ 30 —4— i max. Grab Bars E io E N ' P- tO T Existing 36" Grab Bar co u- LL aD Qi U W P-� !Q to t= to N d Ix ® Z _U®N � q w Li. r J co LU 0 o V Lu I= Cr M o A W 3 Z Q w N date revision X w Plan Review g? 2/7/13 Corn BY Toilet Room Doors to have Lever Doors shall have signs indicating Handle and Privacy Lock ADA Accessable Restroom Lavatory or Sink Controls to be Grab Bars to be 1 1/4" to 1 1/2" Lever Types dia. and 1 1/2" from walls THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO ► drawn al checked eJ. IA date 1/20/13 scale as noted lob nmfber 13004 Shoot A-1 IV FEB 1 2 2013 s x AC. AC. AC. Cond. Cond. Cond � 4 *L �.ril- �= Life scale: Existing Floor Plan scale: 3/16" ® 1'-0" I&I NORTH Typ. Existing A.C. Equipment Air Handlers: 2TTB3042A TRANE (3 1/2 Ton) Condenser Unit: 2TEC31742B1000A, Heat Strip: 10 Kw CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONT MIROFRECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT MANY CORREC11ONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO WW Wff#464+6 044841011j, U C9 C"9 U- to p� W 00 r v � X Z aco .00 _ ~ co Co LL B_ O J o � /�) CDW m co ca LL LU O z a co co T Y ' DC 0 O f+ LL J � 0 W C o o U 0 z W O W 005 J Lu z 0 date I revision 2/7/13 Plan Review Comments drawn 81 checked aJ. date 1/20M scale as noted lob number 13004 shoot A-2 IE0F.0VF FEB 1 2 2013 /3D/-0963 e EXISTING ELECTRICAL PANEL "1" EXISTING ELECTRICAL PANEL "2" (E) (E)A *L(E) (E) EX 1Li 1� (R) Electrical 3W (E) gf g ElectricalPan(E EXI 3w \ #2 (N) el O� �O '>. / . (E) (E) c / . (R) {1}� T T F---I-� -ice relocate light I (R) ��---i (R \ relocate light i/ �} �/ (R) fixture and � fixture and ? _ / Closet x (N) eosptioelas 1 , `j" ehowncalas IN) tJi Closet 1 shown IN / (N (N (R (N) - 3W - I \ ( ) (R) \ (E) (E) (R) T / t (R}� - - i (R) (N (N) --�) --� (E) o o (E) i (R) ITS?� \ / t?✓ (N) I N) -41, Library (E) (N) / / (E) t t j(E) Confrence j(E) I t\ 1 t �;---i h---4;-7-� F-- (E) (E) E 3w EXI (E) 1 � WIMSIM Ig Pl PLUMBING NOTES: Plumber to consult with contractor and equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. All sanitary lines 2" or less shall have a slope of 1/4" per 'foot minimum. All sanitary lines above 2" shall have a slope of 1/8" per foot minimum. (R) F---Ri---i=0 IN) F---R�--- (R) (N (t Office IN) 1 l _ _ IJi (R) \ -(R) Recept. i I (R) Waiting _(R) (N (E ' 3w EX (E) ` l (E) EXISTING ELECTRICAL PANEL 113" ot _ EX ' gf (E) Electrical 10 0. Panel (E) \ 1 #3 I ,. relocate light fixture and y}- ical as show N � shown ( ) (N I(R) IN) t?, I a.h. E I / (E) , (E) P` I (R) \ 3W (R) (R; / tJi / I I I h---:�/-3 (N IN) \ (E) Copy Room I (N)I (N) I 1 i t�(R) T T I I I I / 1 (R)II (R) t IN) y Office (N .� 3W�' / (R) (E) (E) EXI (E) I 'lE) FILE COPY CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBUTY OF THE CONTRACTOR OF RECORD Lav Existing (N) 1/2" Sanitary Existing Water Mai Closet to remain (N) t Plumbing contractor to (E) 2 - - - - - - (E) provide a - - mer and shut water valve at each �E) 1 fixture --- - ------411 r------ ---- , New location (E) of Lavatory 11 pp II (E) 3" VTR � 2" supply Existing Lav WC 3/4" (E) to meter (E) Remove Existing I I Existing water line (E) Sink I Cap off drain at lay. to be removed lines at existing and capped off lavatory Typical at each Toilet Room Typical at each Toilet Room Plumbing Plan Water Supply Scale: 1/4" = F-0" n.t.s. New Lav Location Lav - -� (R) Office IN) (N) (R) Office \---RR)---9 Office (R) Office THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO W'!� A11►APtlL.I�IM�I� �EItlEBa New 2" vent at ceiling ceiling 3'� VTR E) i Cap off drain lines at existing lavatory (E) Typical \ Typical at each Toilet Room Sanitary Riser n.t.s. Existing Sanitary Main ELECTRICAL LEDGEND RECESSED LIGHT WITH LENS @ EXTERIOR & WET LOCATIONS SURFACE MOUNTED LIGHT FIXTURE TT 00 f--- �� ---� SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE M UNDER CABINET FLUORESCENT FIXTURE ( INCH LIGHTS) ^, ^ N-ed RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN - • SENSOR CJ� CEILING FAN O, CEILING MOTION O r� O EXHAUST FAN OUTLET DOOR CHIMES V a bTHERMOSTAT, � 00 SMOKE DETECTOR � W � DUPLEX OUTLET -SWITCHED • 1� Q �+ TELEVISION (�:" DUPLEX OUTLET 220 V OUTLET TELEPHONE W b u .` SWITCHEI PUSH BUTTON _W THREE W AY � EMERG FLO D LIGHT YytSWITCHw rl �'+ S" -.. 3w W/ BATTERY BACKUP yr DIMMER SWITCH p ILLUM. EXIT LIGHT W/ EXl Cl ; BATTERY BACKUP (E) = EXISTING (R) = RELOCATED (N) = NEW NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BEAFCI. O TAMPER PROOF. RECEPTAALES MUST BE INSTALLED IN 120 VOLT, SINGLE ^^�ll (U - ~ PHASE 15 & 20 AMP BRANCH CIRCUITS Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician w 2. All work to meet the 2608 National Electrical Code. Z 3. Calculations and panels below are for sizing conduit and overall a building load requirements only U V) C' N 4. All conductors to be copper; all insulation to be THHN. Conduit as ~ w° follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. n/ o 00p 5. Ensure min, 36" clear between equipent and disconnects, Typical. t� U O 6. Protective ratings shall comply with NEC 110-9 & NEC 110-10 Ct Wi 7. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1 8. Clearance between boxes and cutouts in wall shall not exceed 1/8". Existing Electrical Panel #1 Description: LT.E. Load Center Electrical Schedule 100 MLC 1 PH 3W 120/240V Circuit Description Volts Load KW Breaker Wire Cond. Trip JPole T.B.D. Lights & Recept. 120 3.6 KW 20 A 1 P 2#12 1/2" T.B.D. Lights & Recept. 120 3.6 KW 20 A I 1 P 1 2 #12 1/2" New Additional Load 7.2 KW First 10 KW at 100% 10.00 KW Total Calculated New Load 7.2 KW 7,200 W = 30 Additional Amps 240 Existing Panel Load: 42.80 Amps Total Calculated Panel Load: 72.80 Amps (100 Amp Panel Existing) Existing Electrical Panel #2 Description: I.T.E. Load Center Electrical Schedule 100 MLC 1 PH 3W 120/240V Circuit Description Volts i Load KW Breaker Wire Cond. Trip Ipole T.B.D. Lights & Recept. 120 3.6 KW 20 A 1 P 2 #12 1/2" T.B.D. Lights & Recept. 120 1 3.6 KW 120A I 1 P 1 2 #12 112" New Additional Load 7.2 KW First 10 KW at 100% 10.00 KW Total Calculated New Load 7.2 KW 7,206 W = 30 Additional Amps 240 Existing Panel Load: 42.80 Amps Total Calculated Panel Load: 72.80 Amps (100 AmpnPanel Existing) Existing Electrical Panel #3 Description: 100 MLC T.T.E. Load Center Electrical Schedule I PH 3W 120/240V Circuit Description Volts Load KW Breaker Wire Cond. Trip 1pole T.B.D. Lights & Recept. 120 6.4KWI20AI 1 P 1 2 #12 1/2" T.B.D. Lights;,& Recept. 120 6.4 KW 120A I 1 P 1 2 #12 1/2" New Additional Load 12.8 KW First 10 KW at 100% 10.00 KW Remaining 2.8 KW 40% 1.12 KW Total Calculated New Load 11.12 KW 11,120 W = 46.33 Additional Amps 240 Existing Panel Load: 42.80 Amps Total Calculated Panel Load: 89.13 Amps (100 Amp Panel Existing) Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified M !b U O C/] O O L>a U z w C) O � rx '� LTa a date revvsooj . t drawn s.l. checked S.l. date 1/14/13 scale as noted job nunber 13004 sheet A-3 4 HVAC SCHEDULES AND NOTES: HVAC Units are Trane split system DX Units, 13.0 SEER, each with 1Ci�W Heat Strip. Units are split system 3.5 ton ua �s, Trane 2TTB3042A AHU's with 2TEC3F42B1000A, with 1C KW Heat Strip, 208/230/1/60. Clean all existing ur• is and ductwork. Refer to Architectural Sections for ceiling height restrictions — all equipment and materials shall fit in the space provided. Make modifications as required to accomplish same. Registers/grills/Diffusers shall be Metalaire or equal unless otherwise scheduled — all aluminum. construction. Reuse existing where possible — new grilles shall match existing. SAD's (supply air diffusers) shall be series 5000, M-2, S-4, D-5, of the sizes shown. S-1: one way; S-2: two way, etc. Unless otherwise noted, SAD's shall be 9" x 9" (up to 125 cfm); 12" x12" (130 to 290 cfm); 20" x 20" for 300 cfm and larger. Use M-2 diffusers for drywall ceilings. RAG's shall be type RH of the sizes shown on the plans. TG's (transfer grilles) shall be 16/16 or of the sizes shown on the plans. Provide 1" T/A filters at unit. Return Grille Mark R-1 shall. be 16"x 16'; R-2: 18"x 18"; R-3: 20"x 20'; R-4: 24"x 24 Exhaust fans are existing. Paint all HVAC grilles/registers/diffusers white - verify. Provide outside make up air for each unit — Set cfm at Manual "N" requirement and O/A Calculations. Maintain minimum 10' separation from exhaust openings. Verify with existing. Provide thermostat for each unit — Honeywell, Trane or equal "on — Auto" fan and "Heat/Cnol" settings. Verify with existing. Ductwork shall have joints and seams sealed with approved tape applied with adhesive to make joints air tight. Ducts shall be,, reinforced foil faced 1-1/2" fiberglass insulation board (R-6 minimum). Reuse existing ductwork where possible. Flex duct shaA be L!L 181 Thermaflex cr equal with foil back insulation. Provide spin -in connection with diverter and volume damper for each flex take -off from the main trunk ductwork. The Contractor shall furnish a complete matched component HVAC system in accordance with these drawings, local codes, and the latest editions of,NFPA 90A & 90B, ANSI 8-9.1 Mechanical Refrigeration, SMACNA, ASHRAE, and State of Florida Energy Efficiency Code for Building Ccns-'ruction — FlaCom-10 The Contractor shall obtain all required permits and inspections from governing agencies and furnish a written guarantee that all work shall be free from. defects in materials and workmanship for a period of, one..,year from the date of equipment start up and final acceptance. Manufacturer's instructions and guarantees shall be given to the owner. The contractor shall be responsible for balancing the HVAC system to meet the criteria on the plans and shall return to the site to re -balance the HVAC system after occupancy to satisfy specific individual requirements. Provide duct smoke detectors for all units per Mechanical and Building Code requirements. r Project Area: 3,398 s.f. (Gross) Typ. Existing A.C. Equipment MANUAL "N" Air Handlers: 2TTB3042A TRANS (3 1/2 Ton) HVAC WORKSHEET Condenser Unit: 2TEC3F42B1000A Heat Strip: 10 Kw ROOM: SPACE AREA: 3600 SF JOB: DRAWD3 ' EIR0$ REMODEL ZONEA HVAC PLAN 1/4"=1'-0" N. WALL ........................................ 900 S.F. X 13.68 = 3312 S. WALL ........................................ 900 S.F. X 7.36 = 6624 E. WALL ........................................ 400 S.F. X 4.96 = 1984 W. WALL ....................................... 400 S.F. X 6.56 . _ 2624 N. GLASS ....................................... 0 S.F. X 44 ,= 1+ ,. 0 S. GLASS ....................................... 90 S.F. X 49., 4410 E. GLASS ....................................... 0 S.F. X 33 _ 0 W. GLASS ...................................... 0 S.F. X 91 _ 0 ROOF ............................................ 3600 S.F. X 2.2 = 7920 LIGHTS .......................................... 7200 W X 3.41 = 24552 PEOPLE ......................................... 25.2 X $00 = 12600 INFILL ( 62- 89) ............................... 504 CFM X 54 = 27216 SUB TOTAL = 91242 5 % DUCT LOSSES = 4562.1 TOTAL = 95804.1 USE: EXISTING (3) - 3.6 TON A/C UNITS OK 3193.47 CFM a.e,A4.. O/A CALC`S (PER FMC & ASHRAE 62) 2600 SF x 7/ 1000 = 25.2 PERSONS 25.2 X 20 CFM/PERSON = 504 CFM O/A REQ'D 504 CFM O/A PROVIDED — 168 CFM EACH OF 3 AHU'S THEREFORE O/A OK —� toupy THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO 004- 1lMMAiAANOWOARRBBBES: 4111, VIA 2 1 2013 V � 00 � w z 5 ¢ate aCZ00 VJJ •rJ7 � a � 'd Z U CG a� � w O Q � o � o 6 M Z xp i <a W N o W _ a Z r > ° Z I U I W J W U a U Q .� 7 F o M H W Z a 5 W Q _. U * N N m W J t m 3 n co o m 0 al q W ® 10 it P O rx U O w W Q O U O W Chi Q O � W z^ Cd H drawn s,l. checked 3.1. date 1/14/13 scale as noted job nwnber 13004 sheet M-1 7'-4" 9'-0" 51-? 11 DOOR SCHEDULE Mark Size Door Frame Fire RatingNotes Profile Face Core Finish Material Threshold Finish A 36" x 80" x 1 3/8" Six Panel Masonite Hollow Painted Wood N.A. L Painted N.A. Swing Door B 30" x 80" x 1 3/8" Six Panel Masonite Hollow Painted Wood N.A. Painted N.A. Bifold Door GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transpor/lieight, and all other cost related to the completion of this project, unless expltenly identified here. Owner is responsible for all municipal related charges such as imppgb) fees, and water connection, except building permit tees, which are IdUr included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and ,standard practice. All drawings are not considered complete until the plans have been reviewed by the building department and the building permit has been issued. All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. All toilet room doors to have privacy sets, Male / Female Graphic & Braile Lables All doors to be Medium Duty Thresholds not to exceed 1/2" max. heigth All handsets to be lever type,brushed chrome finish Plumbing Code Data 34 Occupants = 17 Males 17 Females Fixtures: Ratio Required Provided Mate Female Male Female Male Female Unisex Water Closets: 1/25 1/25 1 1 1 1 1 Lavatories: 1 /40 1 /40 1 1 1 1 Urinals: 0 0 Service Sink: 0 0 Drinking Fountain: 1/100 1 "Hi Lo" 1 "Hi Lo" INTERIOR WALL FRAMING Non Load Bearing walls to be 2 x 4 studs 2 4" o.c. Spruce, Pine, Fir (SPF) #2 Grade Lumber or Better. or Metal Studs (25 Gauge). Crimper may be used in lieu of screws. GENERAL CONCRETE NOTES: In the event that the existing concrete slab needs to be cut ensure the following: Concrete shall have a minimum compressive compressive strength of not less than 3000 p.s.i. over compacted, and termite treated soil. 90'-0" 54" min 3'-6" 12" inax. Grab bar at Tkssue /Rear Walt Holder / M o M pp v 0 _ 7 Do not locate tissue holder behind the .�,�-9„ grab bar Water Closet Clearances insulate he water pipe under sink Lavatory Clearances 0 New Interior Frame Walls (Non Load Bearing) FTNTTCT4 C1 A CCTIPTC ATTnXT Unsprinklered Occupancy Group: B Exit Passage: A' Corridors: A Rooms: C 5" 1515" "1 min. c C iu a c en � t Spout I -tight. & Knee Clearance Equipment permitted in shaded area HiLo fountain required as shown w Project Data Building Data Project Name: Chamber of Commerce Occupancy Type: Group B I� t� 00 Street Address: 2935 West Midway Rd. Construction Type: IIIB City: Ft. Pierce Number of Stories: One County: St. Lucie Number of Seats: N.A. State: Florida Project Area: 3,398 s.f. (Gross) Z •� t� Existing r � Building Code r Utilities 0C N2010 Florida Building Code: Building C) 2010 Florida Building Code: Existing Building City Water & Septic -J 2010 Florida Building Code: Plumbing Q 2010 Florida Building Code: Mechanical 2010 Florida Building Code: Accessibility 2010 Fire Prevention Code: NFPA 101 2008 National Electrical Code T� Q �'—•� a Florida Building Code Data Use Group: Business Group B (Office) a� 0 Type of Construction: IIIB Unprotected Occupant Load: 3,398 (Gross) s.f. / 100 = 34 Occupants Dn Required Provided Egress Width: .2" per person x 34 6.8" 288" Length of Dead End Corridor: 20.0' 9.0' Maximum Distance to Exit: 75.0' 43.5' Minimum Number of Exits: 1 9 Fire Protection Reauirement Required Provided Party & Fire Walls: N.A. Structural Frame including columns: 0 0 Girders & Trusses: 0 0 Exterior Bearing Walls: 2 2 Interior Bearing Walls: 0 N.A. Floor Construction: _ 0 0 Roof Construction: 0 0 Life Safetv Svstem Emergency Lighting: Yes Exit Signs: Yes Panic Hardware: No Fire Suppression: No Fire Alarm: No Fire Extinguisers: Min. 2A10BC Scope of Work Interior renovation of three individual tenant rental spaces to be one individual business. Existing HVAC to remain but modified. Existing electrical panels to remain. Total interior space 3,398 sq. ft. T-2" Existing 1'-4" 5'-0" min. New location of19"Wxl7"D Lavatory —\ I —I i D i 60" dia. t1 Turn I I I I I I I Radius I I I I I I 30" 306$ vix---------;60--- cK. Floor Clearances max. Grab Bars E N � cn W - c Existing 36" Grab Bar Toilet Room Doors to have Lever Doors shall have signs indicating Handle and Privacy Lock ADA Accessable Restroom Lavatory or Sink Controls to be Grab Bars to be 1 1/4" to 1 1/2" Lever Types dia. and 1 1/2" from walls A.D.A.. Toilet Room drawn s.l. checked ,.I. date 1/20/13 scale as noted job number 13004 abeet A-1 C I AA, A.G. Cond. Cond. N.C. Cond. Electrical a Panel I E fe10B EXI yr Electrical a frlOBC Panel O Q ® s Electrical II Panel A ext I fire 1 Toile Toilet 1 Toilet \ \ Room Room Room - � x 3068 ® st ® gn 306R - � Cm 3068 - I 68 2666 1 2666 I I 1 h z ® i L 7x3 L -J ® ® L J ®22.56" 1 1 attic s Return Grille Return 22.5" x 36" Grille attic access \ 1 - Retw i (i 2' S" x 36" Gnlle - etnc access 1, 1 I 1 ® \1 \ ® \1 Drinking Fountain Drinking Fountain \ ® \i \ \i Drinking Fountain Fountain \i \1 F- L--4 .. J 7 F_ L-� with Cup Holder with Cup Holder F_ ` �' F_ `_i % with Cup Holder - f= 3...� F_ L_i / Tenant Space 1 Tenant Space 2 / Tenant Space 3 �J III 91-01, Ceiling I � I 9'-0" Ceiling 1 ,,;, � - � i 9'-0"Ceiling 1 VCT Flooring I ] I VCT Flooring I ] , `� I VCT Flooring \ 1,185 Square Feet 1 `' 1 1,203 Square Feet 1 z1 ..1,185 Square Feet 1 -1 Q F--TL_-i 1 — F7-i z 3 z ® ® Typ. A.C. rx 1/ ,I Typ. A.C. 'v r` a ,lJ ,/ Typ. A.C. Supply I I Supply I I Supply \ 0 0 \ 1 1 � aw EX aw EXI 3w e;s Life scale: 3 W Existing Floor Plan <= scale: 3/16" =1'-0" NORTH Tvn. Existfm A.C. Eauinment Air Handlers; 2TTB3042A TRANE (3 l/2 Ton) Condenser Unit: 2TEC3F42B 1000A Heat Strip: 10 Kw U � 00 M 0 Cn - 55 Oo v � � Un W O � O r��> V1 C� O U � Q W Q U O �✓ � � O W 4-4U O U O � W E- C� z drawn s.l. checked s.l. date 1/20/13 scale as noted job number 13004 sheet A-2