Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEu prl 03 - ON 1 % Florida Energy Efficiency Code For' Building Construction Florida Departmenf-of ComrnunityAffairs.• FLA/COM 2004 v2.5 —Form 400A-2004- Method A: Whole Building Performance Method for. Commercial'Buildings Short Desc: PATCHES Owner: Addressl: MIDWAY ROAD Address2: PROJECT SUMMARY BY at Lucie County Description: PATCHES PEDIATRIC City: PORT ST. LUCIE State: FLORIDA Zip: 0 Type: Healthcare -Clinic Class: New Finished building Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Cond Area: 4150 SF Cond & UnCond Area: 4150 SF No of Storeys: I Area entered from Plans 0 SF Permit No: 0 Max Tonnage 10 If different, write in: 3/22/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 1 Compliance Summary Component Design Criteria Result Gross Energy Use 1,341.2 1,769.1 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA RTANT NOTE: An input report of this design building must be submitted with this Compliance Report. 3/22/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 2 CERTIFICATIONS I hereby certify that the plans and a ifications covered by this calculation are in compliance with the Florida Energy Code PreparePa Building Official: rfh _'2Co Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Date_, c3.,,7 7: D'J If Required by Florida law, I hereby certify (') that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: (") Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. '3/22/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 Project: PATCHES Title: PATCHES PEDIATRIC NURSING CENTER Type: Healthcare -Clinic (WEA File: DAYTONABEACH.TMY) External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 2 Main entries 30.00 10.0 300 50 Design: 300 (W) PASSES 'Allowance: 300 (W) Project: PATCHES Title: PATCHES PEDIATRIC NURSING CENTER Type: Healthcare -Clinic (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance ProzoISp1 17 Office - Enclosed 4,150 1 2 2 PASSES PASSES 3/22/2007 EnergyGauge Summit v3.10 incorporating Florida,Energy Code Version - FLA/COM 2004 v2.5 i Project: PATCHES Title: PATCHES PEDIATRIC NURSING CENTER Type: Healthcare -Clinic (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description I Area No. of Design Min Compli- ID I (sq.ft) .Tasks CP CP ance PrOZoISp1 17 Office - Enclosed 4,150 1 2 2 PASSES PASSES Project: PATCHES Title: PATCHES PEDIATRIC NURSING CENTER Type: Healthcare -Clinic (WEA File: DAYTONABEACH.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled <65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity .4ir Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Constant Volume PrOSy2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000.Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Constant Volume PASSES 3/122/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLNCOM 2004 v2.5 Plant Compliance Description Installed Size No Design Min Design Min Eff Eff IPLV IPLV Category Comp liance Open centrifugal, chiller 1 10 5.4, 5.0 5.4 5.3 Water Chilling Packages PASSES (Elec)„ Water Cooled (centrifugal), 0 to 150 tons PASSES Project: PATCHES Title: PATCHES PEDIATRIC NURSING CENTER Type: Healthcare -Clinic (WEA File: DAYTONABEACH.TMY) Water Heater Compliance Description Type Design Category Eff Min Design Max Comp Eff Loss Loss liance Water Heater 1 Electric water heater <= 12 [kW] 0.97 0.86 PASSES PASSES Project: PATCHES Title: PATCHES PEDIATRIC NURSING CENTER Type: Healthcare -Clinic (WEA File: DAYTONABEACH.TMY) Piping System Compliance Category Pipe Din Is Operating Ins Cond Ins Req Ins [inches] Runout? Temp [Btu-in/hr 'Thick [in] Thick [in] [F] SF.F] Heating System (Steam, St Condensate, & Hot Water) 0.00 0.00 P 3/22/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 6 A: PATCHES PATCHES PEDIATRIC NURSING CENTER Healthcare -Clinic L File: DAYTONABEACH.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it El Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? El 3/22/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 7 SIN RNW21609 RIGHT-N ZONE SUMMARY Units: For: By: Job #: U.S. customary (I—P) PATCHES COOLING LOAD Zone: 1 & 2 1. DESIGN CONDITIONS at 3PM Peak load at 3PM Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 50 % Moisture: 61 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 4956 3.. TRANSMISSION GAINS Sensible 9867 Walls: 1559 Glass: 677 Doors: 454 - - Partitions: 196 Floors: 0 Roofs/Ceilings: 5692 Return Air Ceiling: 1290 4. INTERNAL HEAT GAIN Sensible Latent 23834 5940 Occupants: 22500 5940 - - Lights: 54 0 - - Motors: 0 0 - - Appliances &Other: 1280 0 - - 5. INFILTRATION: Outside air cfm: 24 396 1003 6. SUBTOTAL: Spaceload 39053 6943 7. SUPPLY DUCT 1953 - 8. SUBTOTAL: Bldg comp's and supply duct 41006 Actual cfm: 1866 at Supply TD: 20 - - 9. VENTILATION: Make—up air cfm: 201 3313 8397 10. RETURN AIR LOAD: Lighting & roof (net) 588 - 11. RETURN DUCT 1172 - J2. TOTAL LOADS ONEQUIPMENT 46078 15339 HEATING LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 12503 Walls: 3085 Glass: 1336 - Doors: 847 - Partitions: 365 -,' Floors: 3583 - Roofs/Ceilings: 2446 - Return Air Roof: 840 - 15. INFILTRATION; Outside air cfm: 231 7098 16. SUBTOTAL: Building components 19601 17. SUPPLY DUCT: 980 18. VENTILATION: Make—up air cfm: 201 6185 19. HUMIDIFICATION 5223 20. RETURN DUCT 588 21. TOTAL HEATING LOAD ON EQUIPMENT 32577 Manual N: 4th Edition Right-N: Ver.3.0.07 Certified by ACCA to meet all requirements of Manual Form N EnergyGauge Summit v3.10 INPUT DATA REPORT Proiect Information Project Name: PATCHES Orientation: North Project Title: PATCHES PEDIATRIC NURSING CENTER Building Type: Healthcare -Clinic Address: MIDWAY ROAD Building Classification: New Finished building State: FLORIDA Zip: 0 Owner: No.of Storeys: 1 GrossArea: 4150 SF Zones No Acronym Description Type Area [sfl Multiplier Total Area [sfl 1 PrOZol Zone 1 CONDITIONED 4150.3 1 4150.3 ❑ Spaces No Acronym Description Type Depth [ftl Width Height Multi [ftl [ftl plier Total Area [sfl Total Volume [cfl 3/22/2007 EnergyGauge Summit v3.10 I In Zone: PrOZol I PrOZ01Sp1 ZOOSpl Office - Enclosed 99.29 41.80 9.00 1 4150.3 — 3735791:1 Lighting No Type Category No. of Watts per Luminaires Luminaire Power [W] Control Type No.of Ctrl pis In Zone: Pr0Zo1 In Space: Pr0Zo1Sp1 I Recessed Fluorescent - General Lighting 19 50 950 Manual On/Off 1 ❑ 2 No vent Recessed Fluorescent - General Lighting 27 50 1350 Manual On/Off 1 ❑ No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity Dens. R-Value [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: PrOZol 1 PrOZo 1 Wal 5/8" stucco 41.80 99.29 1 4150.3 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [Sf] In Zone: PrOZol In Wall: PrOZolWal I PIOZolWalWil User Defined No 2 PrOZolWalWi2 User Defined No 3 PrOZolWalWi3 UserDefined No 1.2500 0.70 0.58 1.2500 0.70 0.58 1.2500 0.70 0.58 2.00 2.00 3.00 6.00 6 5.00 4 5.00 2 72.0 El 40.0 El 30.0 El 3/22/2007 EnergyGauge Summit v3.10 - Doors - - No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] Ift] plier [sf] [Btu/hr. sE F] [lb/cf] [Btu/sf. F1 [h.sEF/Btu] In Zane: PrOZol In Wall: PrOZolWal 1 PrOZolWalDrl Aluminum door, No 3.00 7.00 3 21.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene 2 PrOZolWalDr2 Aluminum door, No 6.00 7.00 3 42.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] IN plier [sf1 [deg] [Btu/hr. SE F] [Btu/sE F1 [lb/cf] [h.sf.F/Btu] In Zone: Pr 1 PrOZOlRfl Shnglll/2"WD 41.80 99.29 1 4150.3 45.00 0.0320 1.50 8.22 31.2 ❑ Deck/WD Truss/9" Batt/Gyp Brd Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] IN IN [Sf] [Sf] In Zone: In Roof: 3/22/2007 EnergyGauge Summit v3.10 7�__- Floors - No Description Type Width [ft] H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] plier [sf] [Btu/hr. sf. F] [Btu/sL F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 Pr0ZOlFl1 Concrete floor, 41.80 carpet and rubber pad 99.29 1 4150.3 0.5987 9.33 140.00 1.67 ❑ Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Bluth Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 61.50 13.00 8.00 1500.00 0.80 ❑ ❑ PrOSy2 System 2 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 61.50 13.00 8.00 1500.00 0.80 ❑ ❑ Plant Equipment Category Size Inst.No Eft. IPLV 1 Open centrifugal, chiller Cooling Equipment 10.0 [Tons] 1 5.40 [COP] 5.40 3/22/2007 EnergyGauge Summit v3.10 N Water Heaters W-Heater Description CapacitlCap.Unit UP Rt. Efficiency Loss 1 Electric water heater 50 [Gal] [M] 0.9700 [Ef] [Btu/h] ❑ Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sf/ft/No] Control Type Wattage [W] Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sEF] Nomonal pipe Diameter [in] Insulation Thickness [in] Is Runout? I Heating System (Steam, Steam Condensate, & Hot Water) 105.00 0.28 0.25 0.00 Yes ❑ Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ASHULTntAl1Fr User Defined 1 1.2500 0.7000 0.5800 ❑ In 3/22/2007 EnergyGauge Summit v3.10 5 - - - Materials Used - Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtul [ft] [Btu/h.ft.F] [lb/cf] [Btu/Ib.F] 264 Mat1264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 El 1-1/41N, 187 MatI187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 151 Matl151 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 4IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.20o0 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 - 38.00 0.2000 ❑ block 269 Matl269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 12 Matll2 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1002 Aluminum door, 1.25 in. polystyrene No No 0.19 0.53 43.67 5.2 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 264 ALUMINUM, 1/16IN 0.0050 0.000 ❑ 2 214 POLYSTYRENE, EXP., 1-1/41N, 0.1042 0.000 ❑ 3 264 ALUMINUM, 1116 IN 0.0050 0.000 ❑ 3/22/2007 EnergyGauge Summit v3.10 - --Simple- - Massless-- - Conductance - - Heat Capacity —Density�Value__ No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sCFBtu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.000 ❑ 2 178 CARPET W/RUBBER PAD 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sEF] [lb/cf] [h.sf.F/Btu] loll 5/8" stucco /8"CMU/3/4"IS0 No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [it] Factor 1 268 0.625" stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/k.sf.F] [Btu/sf.F1 [lb/cf] [h.sf.FBtu] 1038 Shngf/l/2"WD Deck/WD Truss/9" Batt/Gyp No No 0.03 1.50 8.22 31.2 ❑ Brd Layer Material Material Thickness Framing No. [ft] Factor I 81 ASPHALT -ROOFING, ROLL 0.000 ❑ 2 244 PLYWOOD, 1/21N 0.0417 0.000 ❑ 3 12 3 in. Insulation 0.2500 0.000 ❑ 4 23 6 in. Insulation 0.5000 0.000 ❑ 5 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 ❑ 3/22/2007 EnergyGauge Summit v3.10